Athletic Lockers – Penco Specification Section 10 51 13
Heavy Duty Knocked Down Lockers. Factory assembled ADAAG - Americans with Disabilities Act, Accessibility Guidelines.
A. Bolts and Nuts: Zinc plated truss fin head bolts and hex nuts. With rivet construction
B. Provide only metal lockers fabricated in the United States by a single domestic manufacturer.
HEAVY DUTY LOCKERS
A. Heavy Duty Lockers: All locker body components made of cold rolled steel specially formed for added strength and rigidity and to ensure tight joints at fastening points.
1. Lockers with Doors: Penco Invincible II, knock-down lockers, with no legs (no legs are optional).
B. Locker Body Construction: Steel specially formed for added strength and rigidity and to ensure tight joints at fastening points.
1. Sides, Bottoms, Tops, and Shelves:
a. 16 gauge steel.
b. Ventilation: 3/4 inch (19 mm) wide by 1-1/2 inch (38 mm) high diamond-shaped perforations.
c. Solid sides.
2. Backs: Solid 18 gauge steel.
3. Doors:
a. 14 gauge steel.
b. Ventilation: 3/4 inch (19 mm) wide by 1-1/2 inch (38 mm) high diamond-shaped perforations.
c. Solid doors.
4. Tops and bottoms with three sides formed 90 degrees, the front offset formed to be flush with horizontal frame member.
5. Shelves with four sides formed to 90 degrees, front edge having a second bend.
6. Hole spacing in locker body construction: Not exceeding 9 inches (225 mm).
7. Two- and three-tier lockers: Intermediate channel-shaped horizontal frame members attached to side frames with mortise and tenon construction, securely welded.
8. Optional factory assembly of locker bodies using rivets.
C. Locker Doors: One piece sheet steel.
1. Multi-Point Latch Doors: Full channel formation of adequate depth to fully conceal lock bar on lock side, channel formation on hinge side, right angle formations across top and bottom, with holes for attaching number plates.
DOOR HANDLES AND LATCHING
1. Multi-point latching with recessed handles:
a. Recess finger-lift control handle in door.
b. Pocket: 22 gauge brushed stainless steel securely fastened to door with two tabs and a positive tamper-resistant decorative fastener; of depth sufficient to prevent a combination padlock, built-in combination lock, or key lock from protruding beyond door face.
c. Provide lock hole cover plate for use with padlocks.
d. Attach 14 gauge formed steel lifting piece to latching channel with one concealed retaining lug and one rivet, assuring a positive two-point connection.
e. Handle Finger Lift: Molded, sound-deadening, attached with rivet;
padlock eye for use with 9/32 inch (7.1 mm) diameter padlock shackle.
f. Latch Clip: Glass-filled nylon engaging the door frame and holding the door shut.
1) Doors 60 inches (1.524 m) and 72 inches (1.828 m) high: Three points.
2) Doors 20 inches (0.508 m) to 48 inches (1.22 m) high: Two points.
g. Locking Device: Positive, automatic type, whereby locker may be locked when open, then closed without unlocking.
h. Firmly secure one rubber silencer in frame at each latch hook.
INTERIOR EQUIPMENT
A. ADA-Compliant Lockers (Recessed Handles with Multi-Point Latch):
1. Single Tier Lockers: Hat shelf at maximum 48 inches (1.219 m) off the floor for unobstructed forward and side reach.
2. Locker Compartment Bottom: Minimum of 15 inches (230 mm) off the floor, or an extra shelf placed 15 inches (381 mm) off the floor for unobstructed forward and side reach.
3. Handicapped symbol attached to door.
4. Hooks and rods as specified for other lockers.
B. Athletic Lockers with Doors (Invincible II):
1. Single-Tier, 48 inches (1.219 m) or Higher: Shelf located approximately 9 inches (228 mm) below top of locker.
2. Openings up to 18 inches (457 mm) deep: Three single-prong wall hooks and one double-prong ceiling hook.
3. Openings 18 inches (475 mm) or over deep: Three single-prong wall hooks and one coat rod.
4. Openings 30 inch (760 mm) and 36 inch (914 mm) high: Three single-prong wall hooks and one double prong ceiling hook.
5. Openings 20 inch (508 mm) and 24 inch (610 mm) high: Three single prong wall hooks.
ACCESSORIES
A. Number Plates: Provide each locker with a polished aluminum number plate, 2-1/4 inches (57 mm) wide by 1 inch (25 mm) high, with black numerals not less than 3/8 inch (9.5 mm) high; attach to face of door with two aluminum rivets
B Locks: Built-in grooved key locks (pin tumbler); control-key to same series. Option
C. Continuous Sloped Hoods: 18 gauge steel, slope rise equal to 1/3 of the locker depth (18.5 degrees), plus a 1 inch (25 mm) vertical rise at front.
1. Supplied in 72 inch (1829 mm) lengths only.
2. Slip joints without visible fasteners at splice locations.
3. Provide necessary end closures.
4. Finish to match lockers.
D. Front Fillers: 20 gauge steel formed in an angle shape, with 20 gauge slip joint angles formed in an angle shape with double bend on one leg forming a pocket to provide adjustable mating with angle filler.
1. Attachment by means of concealed fasteners.
2. Finish to match lockers.
EXECUTION
EXAMINATION
A. Do not begin installation until substrates and bases have been properly prepared.
B. If substrate and bases are the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
INSTALLATION
A. Install metal lockers and accessories at locations shown in accordance with manufacturer's instructions.
B. Install lockers plumb, level, and square.
C. Anchor lockers to floor and wall at 48 inches (1.219 m) or less, as recommended by the manufacturer.
D. Bolt adjoining locker units together to provide rigid installation.
E. Install sloping tops and metal fillers using concealed fasteners. Provide flush hairline joints against adjacent surfaces.
F. Install front bases between legs without overlap or exposed fasteners. Provide end bases on exposed ends.
G. Install benches by fastening bench tops to pedestals and securely anchoring to the floor using appropriate anchors for the floor material.
ADJUSTING AND CLEANING
A. Adjust doors and latches to operate without binding. Verify that latches are operating satisfactorily.
B. Adjust built-in locks to prevent binding of dial or key and ensure smooth operation prior to substantial completion.
C. Touch-up with factory-supplied paint and repair or replace damaged products before substantial completion.
PROTECTION
A. Protect installed products until completion of project.