Corridor lockers – Penco Specifications Section 10 51 13 - METAL
LOCKERS
Standard Duty Knocked Down Lockers. Factory Assembled
ADAAG - Americans with Disabilities Act, Accessibility Guidelines.
MATERIALS
Bolts and Nuts: Zinc plated truss fin head bolts and hex nuts. Using rivet construction
Provide only metal lockers fabricated in the United States by a single domestic manufacturer.
STANDARD DUTY LOCKERS
Standard Duty Lockers:
- Tops, Bottoms, Backs, Sides, and Shelves: 24 gauge sheet steel.
- Doors over 12 inches (305 mm) wide or 20 inches (760 mm) high: 16 gauge sheet steel.
- Form door frame members to a channel shape, not less than 16 gauge steel.
- Center partitions: 24 gauge steel vertical partitions, full depth between bottom and shelf.
Locker Doors: One piece sheet steel.
- Multi-Point Latch Doors: Full channel formation of adequate depth to fully conceal lock bar on lock side, channel formation on hinge side, right angle formations across top and bottom, with holes for attaching number plates.
- Provide holes for attaching number plates.
- Doors over 15 inches (380 mm) wide by 60 inches (1.524 m) or 72 inches (1.828 m) high: 3 inch (75 mm) wide
20 gauge full height reinforcing pan welded to inside face of door at 6 inch (150 mm) centers.
- Ventilation: Flush door front with no exposed louvers and air flow slots located in top and bottom flanges of door.
Hinges:
DOOR HANDLES AND LATCHING
- Classic III Multi-point latching with recessed handles:
- Recess finger-lift control handle in door.
- Pocket: brushed stainless steel securely fastened to door with two tabs and a positive tamper-resistant decorative fastener; of depth sufficient to prevent a combination padlock, built-in combination lock, or key lock from protruding beyond door face.
- Provide lock hole cover plate for use with padlocks.
- Attach 14 gauge formed steel lifting piece to latching channel with one concealed retaining lug and one rivet, assuring a positive two-point connection.
- Handle finger lift: Molded, sound-deadening, attached with rivet; padlock eye for use with 9/32 inch (7.1
mm) diameter padlock shackle.
- Latch Clip: Glass-filled nylon engaging the door frame and holding the door shut.
- Doors 60 inches (1.524 m) and 72 inches (1.828 m) high: Three points.
- Doors 20 inches (0.508 m) to 48 inches (1.22 m) high: Two points.
- Locking Device: Positive, automatic type, whereby locker may be locked when open, then closed without unlocking.
INTERIOR EQUIPMENT
- ADA-Compliant Lockers (Recessed Handles with Multi-Point Latch):
- Single Tier Lockers: Hat shelf 48 inches (1.219 m) maximum off the floor.
- Locker Compartment Bottom: Minimum of 15 inches (230 mm) off the floor, or an extra shelf placed 15 inches (381 mm) off the floor for unobstructed forward and side reach.
- Handicapped symbol attached to door.
- Hooks and rods as specified for other lockers.
ACCESSORIES
- Number Plates: Provide each locker with a polished aluminum number plate, 2-1/4 inches (57 mm) wide by 1 inch
(25 mm) high, with black numerals not less than 3/8 inch (9.5 mm) high; attach to face of door with two aluminum rivets.
- Locks: Built-in grooved key locks (pin tumbler); control-key to same series. Option
- Continuous Sloped Hoods: 18 gauge steel, slope rise equal to 1/3 of the locker depth (18.5 degrees), plus a 1 inch
(25 mm) vertical rise at front.
- Supplied in 72 inch (1829 mm) lengths only.
- Slip joints without visible fasteners at splice locations.
- Provide necessary end closures.
- Finish to match lockers.
- Finished End Panels: Minimum 16 gauge steel formed to match locker depth and height, 1 inch (25 mm) edge dimension; finish to match lockers; install with concealed fasteners.
- Front Fillers: 20 gauge steel formed in an angle shape, with 20 gauge slip joint angles formed in an angle shape with double bend on one leg forming a pocket to provide adjustable mating with angle filler.
- Attachment by means of concealed fasteners.
- Finish to match lockers.
EXECUTION
EXAMINATION
- Do not begin installation until substrates and bases have been properly prepared.
- If substrate and bases are the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
INSTALLATION
- Install metal lockers and accessories at locations shown in accordance with manufacturer's instructions.
- Install lockers plumb, level, and square.
- Anchor lockers to floor and wall at 48 inches (1.219 m) or less, as recommended by the manufacturer.
- Bolt adjoining locker units together to provide rigid installation.
- Install sloping tops and metal fillers using concealed fasteners. Provide flush hairline joints against adjacent surfaces.
ADJUSTING AND CLEANING
- Adjust doors and latches to operate without binding. Verify that latches are operating satisfactorily.
- Adjust built-in locks to prevent binding of dial or key and ensure smooth operation prior to substantial completion.
Option
- Touch-up with factory-supplied paint and repair or replace damaged products before substantial completion.
PROTECTION
- Protect installed products until completion of project.