This is a materials list (Bill of Materials) for the B1143 Transformer Replacement project at Peterson Space Force Base, Colorado, supporting solicitation FA251726QA005. The document specifies approximately 50 line items across multiple categories of electrical and mechanical equipment required for transformer replacement operations.

The materials encompass cable pulling and rigging equipment (various sizes of cable pulling grips, round slings, and wire rope slings with breaking strengths ranging from 6,500 to 26,400 lbs), cable management tools (sheaves, mandrels, corner guides, and pulling harnesses), grounding equipment (grounding clamps, grounding sets rated for 15kV and higher, temporary ground rods, and ground mats compliant with OSHA 1910.269), dewatering pumps with discharge hoses, electrical connectors and lugs, safety switches, fuses, PVC conduit and fittings, and extensive quantities of electrical wire in various gauges and colors. Specific quantities are provided for each item, with notably large orders for copper conductor wire (3,000 feet of 2 AWG 15kV URD cable and 4,000 feet of 2 AWG THHN/THWN-2 building wire in multiple colors). The list identifies brand-name products with "Brand Name or Equal" language allowing for substitutions of equivalent products, and includes detailed technical specifications such as load capacities, voltage ratings, insulation types, and dimensions for most items to ensure procurement of appropriate replacements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Attachment 2 -List of Materials for B1143 Transformer Replacement Project
ItemFurther SpecificationsUnitQty
Heavy Duty Wheel Chock
EACH4
1.5inch - 1.99inch Double Weave Mesh Cable Pulling GripBrand Name or Equal*

Approximate Breaking Strength: 13,800 lbs

Mesh Length: 24''EACH3
2.5inch - 2.99inch Double Weave Mesh Cable Pulling GripBrand Name or Equal*

Approximate Breaking Strength: 17,500 lbs

Mesh Length: 28''EACH3
3inch - 3.75inch Double Weave Mesh Cable Pulling GripBrand Name or Equal*

Approximate Breaking Strength: 18,000 lbs

Mesh Length: 30''EACH3
6 ft Liftex Eye & Eye RoundSling--13,200 lbs RedBrand Name or Equal*

Color Red Body Width: 3.50" Rated Capacity Vertical: minimum 13,200 lbs Rated Capacity Choker: minimum 10,600 lbs

Rated Capacity Basket: minimum 26,400 lbsEACH1
Condux Corner Cable Guide - 8inch Metal RollerBrand Name or Equal*
8 inches, minimum of 5,000Lbs cable tension load capacityEACH1
Condux Cable Feeding Sheave- 4 inch Metal RollerBrand Name or Equal*
4 inches, minimum of 6,500 Lbs load capacityEACH1
Condux Rubber Slug Mandrel 2inch conduitBrand Name or Equal*
2 inch duct size minimum of 4,500 Lbs load capacityEACH1
Condux Rubber Slug Mandrel 4inch conduitBrand Name or Equal*
4 inch duct size minimum of 4,500 Lbs load capacityEACH1
Condux Rubber Slug Mandrel 6inch conduitBrand Name or Equal*
6 inch duct size minimum of 4,500 Lbs load capacityEACH1
Condux Heavy Duty Sheave 6"x11"Brand Name or Equal*

6 inches wide

Minimum 12,000Lbs cable tension load capacityEACH2
Ashley Eye to Eye Wire Rope Sling - 1/2" x 6'Brand Name or Equal*

Diameter of Rope (inches): 1/2

Minimum* Length of Sling (SL) (ft. in.)2-6EACH3
Conduit Pull Tape, 1800 lbs, 5/8x3000ftBrand Name or Equal*

Minimum Break strenght 1800 lbs.

Width 5/8"EACH2
Reel-Thing Cable Reel Lifting Device - 12,000 lbsBrand Name or Equal*

Arbor Size: Minimum 4-1/2"(114mm) - Maximum 6"(152mm)

Weight Capacity: minimum 12,000 lbs (5,443 kg)EACH1
Jameson EASY BUDDY 1/4" x 500' Fiberglass Duct RodderBrand Name or Equal*

Minimum 400-lb Pull/Tensile Strength

Accessory Kit Including: Splice Ferrule, Pulling Eye, End Ferrule, and AdhesiveEACH1
Condux Multiple Pulling Harness - 3 Way 1/2" (13 mm) CableBrand Name or Equal*

Working Load Per Leg: minimum 7,000 lbs Working Load Combined: 15,000 lbs Max Width (A): 3.75" (95 mm) Separation Between Legs (B): 12" (305 mm)

Lead Ring Diameter (C): .87" (22 mm)EACH1
Ashley Reel Lifting Sling, 3/4" x 6Ft, 6,500 lbsBrand Name or Equal*

Minimum Rating: 6,500 lbs @ 60 Degrees Rope: 3/4" x 6 Feet

Lifting Ring: 6" x 3-1/2" IDEACH1
Adjustable 4 Leg Transformer SlingBrand Name or Equal*

5/8" rope with chaffing sleeve on eyes Adjusts from 60” to 84” minimum

Safe working load minimum 12,820 lbsEACH1
Greenlee 18" Cable SheaveBrand Name or Equal*

OUTSIDE DIAMETER 18" (457.2 mm) INSIDE RADIUS 7" (177.8 mm) WEIGHT 6" (152.4 mm) 44 lbs

MINUMUM CAPACITY 8,000 lbs.EACH1
Chance Equi-Mat Slip-Resistant Ground Mat Kit With Ground Set & Bag , Minimum 58" x 120"Brand Name or Equal*

Portable with Tool Bag For standing on during various energized and deenergized work practices

Accomplishes compliance with OSHA 1910.269: “Equipotential Zone."

Consists of a high-ampacity tinned-copper-braid cable sewn in a grid pattern onto a vinyl/polyester fabric Cable terminals permit connecting mat's grid in series with an electrical ground and subject system component or vehicle

Mat may be folded and stored in a tool bag to help keep it clean and protectedEACH2
Salisbury Concentric Neutral Grounding Clamps With 4' CableBrand Name or Equal*
Made with two ground clamps and 4 ft (1.22 m) of 1/0 clear jacketed extra flexible copper cable, the concentric neutral ground clamp is spring pressured.EACH1
Hastings Grounding Set 1/0 x 6' Cable With 1.5" Aluminum Serrated Jaw ClampsBrand Name or Equal*
Ground Set with 1/0 x 6' cable and aluminum serrated jaw clamps.EACH4
Hastings 15KV URD 3-Phase Grounding Set 1/0 x 6'Brand Name or Equal*

3 - 1/0 x 6 feet cables Flat jaw clamp Rated at 10KA for 10 cycles

EACH1
Chance 15kV URD Grounded Parking Bushing Set With 4' Yellow 1/0 Grounding CableBrand Name or Equal*

15kV parking stand bushing ground set for single phase URD switches & transformers

Fault current rating of 10kA for 10 cyclesEACH3
Hastings 15KV URD Grounding Set 1/0 x 6'Brand Name or Equal*
15KV URD Grounding Set, 1/0 x 6 feetEACH3
Hastings Ground Set Storage BagBrand Name or Equal*
heavy vinyl storage bag fits 15KV, 25KV, and 35KV ground setsEACH4
Hastings Temporary Ground RodBrand Name or Equal*
5/8" diameter copper weld rod with a 12" bronze handle. Auger screw for easy penetration. Overall length is 74"EACH2
Allegro Sludge Dewatering Pump
Brand Name or Equal*

Fully submersible up to 39 ft. (minimum) 16 ft. power cord (minimum) Impeller with agitator to suspend solids Fire hose-style quick-connect fittings Performance Range: 15~50 GPM

each1
Allegro 50 ft. Discharge Hose for Dewatering Sludge PumpsBrand Name or Equal*

Must be compatible with quoted Sludge Dewatering Pump 50 Ft each 1

Cooper Power Systems (Eaton) Load Break Elbow, #2 AWG Str, #1 AWG Sol, 7.6 L x 9 H x 2.9 in. W, 200ABrand Name or Equal*
Loadbreak Elbow w/ Integral Jacket Seal & Test Point, 200A,mp, 15 kV, Insulation Range: 0.610" - 0.970".each15
Burndy 2 AWG Two Hole Long Barrel, 3/8 Inch Stud, Copper Compression LugBrand Name or Equal*

Copper Compression Lug, 2 Hole w/ Inspection Window, 2 AWG Flex, 3/8" Stud, 1" Stud Hole Spacing, Long Barrel, Tin Plated.

Voltage Rating:

600-35kV Volts

Lug Material: Copper

each30
Type ADR-ALCUL Dual Rated Mechanical Connector, 2 AWG-600 kcmil Conductor, 1/2 IN Stud, 4 Bolt Holes2 AWG-600 kcmil Conductor, 1/2 IN Stud, 4 Bolt Holeseach8
Pointed End Ground Rod: 5/8 in Dia, 8 ft Overall Lg, Copper Bonded SteelOverall Length: 8 ft
Overall Width: 5/8''each8
Grounding Connector: Copper, 10 AWG SOL/12 to 1 AWG STR Grounding Wire Size, 1 Grounding WiresGrounding Wire Size: 10 AWG SOL/12 to 1 AWG STReach10
Safety Switch, 60A, 3P, 600VAC/250VDC, Type DH, Fusible, NEMA 3R60 AMP, 3-Pole, Heavy Duty Safety Switch, Fusible without Neutral, 600 VAC, 250 VDC, NEMA 3R.each1
35A, 600VAC/600VDC, Class RK5 Fuses35 Amp, 600V, Industrial & Electrical Fuses UL Class RK5 Duel Element Time-Delay fuse With Indicationeach6
Submersible Connector, Volts AC: 600, Allowable Gauge Range: 14- 2/0, Wire/Cable Openings: 4Submersible Connector, 4 Port, 2/0 AWG - 14 AWGeach16
Heavy Duty Box with Lid, 17" x 30" x 24" Polymer Concrete, Includes Penta Boltseach4
2" PVC Conduit, 10' Length, Schedule 40, Gray, Bell Endbundle (10)60
Coupling, 2" Diameter, PVC, Grayeach60
2" PVC 90° Elbow, Schedule 40, Grayeach12
Deep Strut - Elongated Holes, Steel, Pre-Galvanized, 1-5/8" x 1-5/8" x 10'each20
1" Pulling Rope (2400 ft)
Breaking Strength: 42,000 lbseach1
Pro-Pull Measuring Pull Tape, 1250 lb. Tensile Strength, 1000' ReelBrand Name or Equal*
1250 lb. Tensile Strength, 1000' Reeleach2
Bushing Well Protective Cap, 200 Amps, Posi-Break, Protective Cap, 25kV Volts ACeach24
Elbow Surge Arrestor, 10KV-15KVeach12
4 port Loadbreak Junction Stainless Steel, Brkt 200A, 15kVeach6
Cold Shrink, Shield Adapter Kit, O.D. Range: 0.83" - 1.64"each24
THREE REELS, (SEPARATE REELS 1000' EACH) OF # 2 AWG Stranded Copper Conductor 15KV URD, EPR Insulation, Full Neutral 133%Per Foot3000
2 AWG THHN/THWN-2 Building Wire – Cut to Length----BLACKPer Foot1000
2 AWG THHN/THWN-2 Building Wire – Cut to Length----REDPer Foot1000
2 AWG THHN/THWN-2 Building Wire – Cut to Length----BLUEPer Foot1000
2 AWG THHN/THWN-2 Building Wire – Cut to Length----WHITEPer Foot1000
4 AWG THHN/THWN-2 Wire (By-the-foot)----GREENPer Foot1000