Attachment 2 - Kleine Brogel Building Layouts_012825.pdf
PDF 7 MB Posted
- Attached to
- Pre-Solicitation Site Visit - Kleine Brogel AB, Belgium Installation Warning System (IWS)
- Solicitation number
- FA560625Q2012
About this file
The document is a detailed floor plan and layout set for multiple buildings (Buildings 93, 94, 99, 116, 118, 128, 250, 258, 282, 283, 289, 292, and 293) at Kleine Brogel Air Base in Belgium, showing proposed Installation Warning System (IWS) speaker and communication infrastructure configurations. The plans comprehensively map out new ceiling and wall speakers, indoor speaker units (ISU), wall horns of varying wattages (15W and 30W), and their precise placement within different rooms and spaces across the facility. Some buildings require comprehensive speaker coverage, while others, like Building 128, are noted as requiring "No outside speakers."
The technical drawings include specific details such as LAN rack locations, communication terminals, server rooms, and other technical infrastructure elements. The layouts demonstrate a systematic approach to ensuring 100% personnel coverage for emergency communication, with speakers strategically positioned in areas like help desks, communication centers, storage rooms, offices, and common areas. The documentation appears to be part of a pre-solicitation site visit preparation for engineering, designing, furnishing, installing, and testing a turn-key Installation Warning System solution, with a site visit scheduled for 14 May at the Kleine Brogel Main Gate, requiring advance registration and access coordination.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 1 - Kleine Brogel IWS Draft SOO_ 012825.pdf | ||
| Attachment 3 - Entry Access Requirements.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
New ceiling speaker New wall Horn, 15W New wall Horn, 30W Indoor speaker Unit (ISU)
New ceiling speaker
New ceiling or wall speaker
CP desk
No outside speakers required
New ceiling or wall speaker
Bldg 128
Bldg 258 Bldg 250
New wall Horn, 15W
Bldg 289 Existing ceiling speaker, leave as-is Existing wall horn, leave as-is New wall Horn, 15W
Indoor speaker Unit (ISU)Bldg 292, LMF
Bldg 293
Bldg 293Indoor speaker Unit (ISU)
ISU
ELMR shelter
Bldg 293
Sound Coverage
| 93� |
| 94 & 116� |
| 99� |
| 118� |
| 128� |
| 250� |
| 258� |
| 282� |
| 283� |
| 289� |
| 292, LMF� |
| 293, Flr 1� |
| 293, Flr 2� |
| ELMR Tower� |
| all Bldgs-30W horns� |