This is an Equipment List attachment for a Request for Quotation (RFQ) issued by the Department of the Treasury Bureau of Engraving and Printing for Switchgear Maintenance and Emergency Repair services at the Bureau's DC Facility. The equipment list identifies 14 distinct transformer and switchgear systems requiring maintenance coverage, spanning locations across the Main and Annex buildings. Equipment includes dry and oil-cooled transformers with voltage ratings of 120/208V, 277/480V, 4160V, and 13,800V, with quantities ranging from one to three units per location. The list specifies coverage periods including a Base year and four Option Years, with most equipment marked for Base and Option Year 1 coverage, and select items extended through Option Year 4.
The government reserves the right to add or delete equipment from the list via modification, and contractors must promptly notify the government of any pricing impacts resulting from such changes. Two locations within the Annex (9th East and West Penthouses and Sub Basement) contain identical equipment configurations. Notably, equipment listed under Item 14 in the Main Basement RM 19M is identified as relatively new and was not previously covered under a maintenance program. This attachment serves as the definitive scope of equipment for which contractors must provide maintenance and emergency repair services under the solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 1 - PWS.docx | DOCX document | |
| Attachment 5 - Site Visit Information.rtf | RTF text file | |
| Attachment 6 - Q_A Template.xlsx | XLSX spreadsheet | |
| Attachment 4 - Pricing Sheet.xlsx | XLSX spreadsheet | |
| RFQ 2031ZA26Q00101.pdf | ||
| Attachment 3 - Wage Determination.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Equipment List
| Number | Location | Transformer Cooling Oil / Dry | Voltage | # of Subs and X-formers | Base | Option Year 1 | Option Year 2 | Option Year 3 | Option Year 4 | |
| 1 | MAIN 2ND RM 201M | Dry | Med | 120/208V | 1 | X | X | X | ||
| 1 | MAIN 2ND RM 201M | Low | X | X | ||||||
| 2 | MAIN 3RD RM 331M | Dry | Med | 120/208V | 1 | X | X | X | ||
| 2 | MAIN 3RD RM 331M | Low | X | X | ||||||
| 3 | ANNEX 9TH EAST PENTHOUSE** | Oil | Med | 120/208V | 3 | X | X | |||
| 3 | ANNEX 9TH EAST PENTHOUSE** | Low | X | |||||||
| 4 | ANNEX 9TH WEST PENTHOUSE** | Oil | Med | 120/208V | 3 | X | X | |||
| 4 | ANNEX 9TH WEST PENTHOUSE** | Low | X | |||||||
| 5 | ANNEX SUB BASEMENT** RM S-6 / S-4 | Oil | Med | 120/208V | 3 | X | X | |||
| 5 | (includes room Nos. S-4-1, S-4-2 and S-4-3) | |||||||||
| ANNEX SUB BASEMENT** RM S-6 / S-4 | Low | X | ||||||||
| 6 | MAIN 2ND RM 201M | Dry | Med | 277/480V | 2 | X | X | X | ||
| 6 | MAIN 2ND RM 201M | Low | X | X | ||||||
| 7 | MAIN 2ND RM 216M | Dry | Med | 277/480V | 2 | X | X | X | ||
| 7 | MAIN 2ND RM 216M | Low | X | X | ||||||
| 8 | MAIN 3RD RM 331M | Dry | Med | 277/480V | 2 | X | X | X | ||
| 8 | MAIN 3RD RM 331M | Low | X | X | ||||||
| 9 | ANNEX BASEMENT RM 24A | Dry | Med | 277/480V | 2 | X | X | |||
| 9 | ANNEX BASEMENT RM 24A | Low | X | |||||||
| 10 | MAIN BASEMENT RM 34M | Dry | Med | 277/480V | 2 | X | X | X | ||
| 10 | MAIN BASEMENT RM 34M | Low | X | X | ||||||
| 11 | MAIN BASEMENT RM 24M | Oil | Med | 277/480V | 2 | X | X | X | ||
| (main secondary transformers are located outside. total of 2) | ||||||||||
| 11 | MAIN BASEMENT RM 24M | Low | X | X | ||||||
| 12 | MAIN BASEMENT RM 34M | Oil | Med | 4160V | 3 | X | X | X | ||
| 13 | MAIN 15 KV RINGBUSS LINEUP (located in a separate room in 34M) | N/A | Med | 13,800V | X | X | ||||
| 14 | MAIN BASEMENT RM 19M | Dry | Med | 277/480V | 2 | X | ||||
| *This equipment is relatively new and as a result was not covered under a previous maintenance program. | ||||||||||
| **Identical equipment set-up |
Changes to the Equipment list: The Government reserves the right to add or delete equipment from the above list via modification. The Contractor shall promptly notify the Government of any impact to the pricing (i.e. increase or decrease) as a result of such changes.
Attachment C - Equipment List dated 08/18/10