Attachment 2 E Drawings Bldg 62 Renovation.pdf

PDF 8 MB Posted

Attached to
Building 62 Renovation Federal contract opportunity
Solicitation number
75F40122R00086
Issued by
Department of Health and Human Services Food and Drug Administration Office of Acquisition and Grant Services

About this file

This document package includes construction drawings and specifications for the Building 62 Renovation project for the Department of Health and Human Services Food and Drug Administration. The drawings show details for roof repairs including replacement of roof drains, installation of new roofing membrane, flashing details, and parapet wall details. Reference drawings are also provided. The related federal contract opportunity is solicitation number 75F40122R00086 for the Building 62 Renovation project. A site visit is scheduled as outlined in Section L-11 of the solicitation documents. Responses to the solicitation are due on the date specified. The contract will be awarded by the FDA Office of Acquisition and Grant Services.

View the file

Other files for this federal contract opportunity

Other files attached to Building 62 Renovation, newest first.
File Type Posted
Amendment 5 Attachment 1 revised Sol Doc bldg 62 renovation.docx DOCX document
Amendment 5 Attachment 3 as-builts 1962 Pilot Line Facilities - 03-01-62.pdf PDF
Amendment 5.pdf PDF
Amendment 5 Attachment 2 Substitution Request form.pdf PDF
amendment 4.pdf PDF
amendment 3.pdf PDF
Amendment 3 Attachment 3 Section 280746-CAT 6.pdf PDF
Amendment 3 Attachment 1 Campus 1991-1992 - Street Lighting System - 11-24-92.pdf PDF
Amendment 3 Attachment 2 Table of Contents_10.03.2022.pdf PDF
Amendment 2 Attachment 2 updated Attachment J-3 Wage Decision.pdf PDF
Amendment 2 Attachment 3 09 6700-RESINOUS AGGREGATE FLOORING 09.30.2022.pdf PDF
Amendment 2 Attachment 1 revised Sol Doc bldg 62 renovation.pdf PDF
amendment 2.pdf PDF
Amendment 1 Attachment 3 Site Light cutsheet.pdf PDF
Amendment 1 Attachment 4 Adaptor cutsheet.pdf PDF
Amendment 1.pdf PDF
Amendment 1 Attachment 1 updated Specifications.pdf PDF
Amendment 1 Attachment 2 A1.02 22.09.12 UPDATE.pdf PDF
Attachment 2 D Drawings Bldg 62 Renovation.pdf PDF
Attachment 2 G Drawings Bldg 62 Renovation.pdf PDF
Attachment 4 - Form FDA 3398.pdf PDF
Sol Doc 75F40122R00086 bldg 62 renovation.pdf PDF
Attachment 2 A Drawings Bldg 62 Renovation.pdf PDF
Attachment 2 B Drawings Bldg 62 Renovation.pdf PDF
Attachment 5 Sample Client Authorization Letter.docx DOCX document
Attachment 6 Past Performance Evaluation Questionnaire.docx DOCX document
Attachment 1 Project Manual Bldg 62 Renovation.pdf PDF
Attachment 2 C Drawings Bldg 62 Renovation.pdf PDF
Attachment 2 F Drawings Bldg 62 Renovation.pdf PDF
Attachment 3 Wage Determination.pdf PDF
Show all 30

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MEMBRANE BASE SHEET (fully adhere)

FLASHING SYSTEM (extend a minimum 8" beyond outermost edge of drain)

MEMBRANE BASE SHEET (fully adhere, lap a minimum of 4" beyond Flashing)

MEMBRANE CAP SHEET

STRAINER & CLAMPING RING

EXISTING ROOF DECK

MASTIC (set all roof layers above Flashing in mastic 6" around drain perimeter)

APPROVED COVERBOARD

MEMBRANE BASE SHEET

(fully adhere to roof surfaces)

FLASHING SYSTEM

(fully adhere - wipe w/ approved solvent before lapping subsequent sheets)

MEMBRANE BASE SHEET(fully adhere)

MASTIC (shaded area)

MEMBRANE CAP SHEET (fully adhere)

CLAMPING RING

OVERHEAD VIEW

4"

CAUTION: FOLLOW ALL PRACTICES PERTAINING TO NRCA CERTA GUIDELINES WHEN TORCHING METHODS ARE EMPLOYED. THIS INCLUDES PERFORMING A FIRE WATCH FOLLOWING ANY TORCH APPLICATIONS.

ALWAYS HAVE APPROVED FIRE-EXTINGUISHING EQUIPMENT NEARBY.

NOTE: BASIS OF DESIGN = SIPLAST. SEE SPECIFICATION FOR OTHER ACCEPTABLE MANUFACTURERS.

NEW STRAINER

CAUTION: SIPLAST RECOMMENDS THAT ALL PRACTICES PERTAINING TO NRCA CERTA GUIDELINES BE FOLLOWED WHEN TORCHING METHODS ARE EMPLOYED. THIS INCLUDES PERFORMING A FIRE WATCH FOLLOWING

ANY TORCH APPLICATIONS. ALWAYS HAVE APPROVED FIRE-EXTINGUISHING EQUIPMENT NEARBY.

EXISTING ROOF DECK

PARADIENE 20

(dry on cant, fully adhere to roof surfaces)

PARADIENE 20 SA

(fully adhere to primed substrate and underlying Paradiene 20)

PARADIENE 30 FR (fully adhere, prepare granule surfaces)

VERAL, PARAFOR 50 TG, PARAFOR 30 TG, OR PARADIENE 40 FR TG

(torch to prepared surfaces and fasten 9" o.c.)

WALL (prime masonry surfaces)

CONTINUOUS SEALANT

NON - COMBUSTIBLE CANT

APPROVED COVERBOARD

PARADIENE 20 SA

(fully adhere to vertical and horizontal surfaces as shown)

NOTES:

1. PREPARE GRANULE SURFACES UNDER FLASHING BY TORCH PREPARATION.

2. WHERE PRIMER IS INDICATED TO MAINTAIN PROPER ADHESION, TA-119 PRIMER IS REQUIRED FOR ALL PARADIENE 20 SA FLASHING REINFORCING AND STRIPPING PLY APPLICATIONS. USE PA-1125 OR PA-917 LS PRIMER FOR ALL OTHER PARADIENE 20 SERIES PRODUCTS THAT ARE NOT SELF-ADHESIVE SHEETS. CONTACT SIPLAST FOR SPECIFIC REQUIREMENTS.

3. THE METAL WORK SHOWN DEPICTS SHOP FABRICATION AND JOB-SITE ASSEMBLY. THESE COMPONENTS SHOULD BE DESIGNED/FABRICATED/INSTALLED ACCORDING TO GENERALLY ACCEPTED INDUSTRY PRACTICES, STANDARDS, AND APPROVALS.

4. A NAILER AND TREATED WOOD CANT MAY BE REQUIRED FOR COMPLIANCE WITH SPECIFIC BUILDING CODES OR APPROVALS.

5. DISSIMILAR METAL TYPES SUBJECT TO ELECTROLYTIC REACTION SHOULD BE PHYSICALLY SEPARATED.

6. REQUIREMENTS AND RECOMMENDATIONS DETAILED IN CURRENT SIPLAST SPECIFICATIONS SHALL APPLY IN ADDITION TO THE ABOVE DRAWING.

M

IN

IM

U

M

3" 1"

PARAPET - WALL SUPPORTED DECK with TORCH-APPLIED FLASHING

PARADIENE 20/30 FR - NVS SUBSTRATE

CONTINUOUS TERMINATION BAR PARALLEL TO ROOF

SURFACE. PROVIDE WATERTIGHT ANCHORS AT 12" O.C.

RIGID INSULATION

EXIST. ROOF DECK

WOOD CURB

VERIFY EXISTING CONDITIONS

COUNTER FLASHING

NON - COMBUSTIBLE CANT

MEMBRANE BASE SHEET (fully adhere to vertical and horizontal surfaces as shown)

MEMBRANE BASE SHEET (dry on cant, fully adhere to roof surfaces)

MEMBRANE BASE SHEET

(mechanically attach to wood curb with approved fasteners, fully adhere to underlying base sheet)

MEMBRANE CAP SHEET

(fully adhere)

ALUM. FLASHING SHEET EQUAL TO

VERAL (torch to prepared surfaces and fasten 9" o.c.)

BASE SHEET FLASHING STRIP

NOTES:

1.PREPARE GRANULE SURFACES UNDER FLASHING BY TORCH PREPARATION.

2.WHERE PRIMER IS INDICATED TO MAINTAIN PROPER ADHESION, TA-119 PRIMER IS REQUIRED FOR ALL PARADIENE 20 SA FLASHING REINFORCING AND STRIPPING PLY

APPLICATIONS. USE PA-1125 OR PA-917 LS.

3.THE CARPENTRY AND METAL WORK SHOWN DEPICTS SHOP FABRICATION AND JOB-SITE ASSEMBLY.

4.DISSIMILAR METAL TYPES SUBJECT TO ELECTROLYTIC REACTION SHOULD BE PHYSICALLY SEPARATED.

5.REQUIREMENTS AND RECOMMENDATIONS DETAILED IN CURRENT SIPLAST SPECIFICATIONS SHALL APPLY IN ADDITION TO THE ABOVE DRAWING.

3" 3"

1"

NOTE: BASIS OF DESIGN = SIPLAST. SEE SPECIFICATION FOR OTHER ACCEPTABLE MANUFACTURERS.

CAUTION: FOLLOW ALL PRACTICES PERTAINING TO NRCA CERTA GUIDELINES WHEN TORCHING METHODS ARE EMPLOYED. THIS INCLUDES PERFORMING A FIRE WATCH FOLLOWING ANY TORCH APPLICATIONS. ALWAYS HAVE APPROVED FIRE-EXTINGUISHING EQUIPMENT NEARBY.

NOTE: TURN ROOF LAYERS UP

AND OVER CURB - TYPICAL

APPROVED

COVERBOARD

THESE COMPONENTS SHOULD BE DESIGNED/FABRICATED/INSTALLED ACCORDING TO GENERALLY ACCEPTED INDUSTRY PRACTICES, STANDARDS, AND APPROVALS.

PRIMER FOR ALL OTHER PARADIENE 20 SERIES PRODUCTS THAT ARE NOT SELF-ADHESIVE SHEETS. CONTACT SIPLAST FOR SPECIFIC REQUIREMENTS.

EXISTING

OPENING

AND CURB

NEW WOOD FRAMING AS REQ'D

PREFINISHED METAL CAP OVER

3/4" PLYWOOD TOP

REPLACE CURBS IF DETERIORATED -

TYPICAL ALL CURBS AND PERIMETER

BLOCKING AT EDGE OF ROOF.

ROOF SYSTEM SEALANT

TREATED 2x_ WOOD CONTINUOUS

PREFINISHED METAL ROOF

EDGE FLASHING (DRIP EDGE)

NEW ROOFING SYSTEM

ROOF EDGE FASTENERS

REINSTALL GUTTER

Copyright

Date

Title

Sheet No.

901 West Third Street Little Rock, Arkansas 72201 501.374.5300

Seal

Job No.

www.WERarch.com

SRQPNMLKJHGFEDCBA

A B C D E F G H J K L M N P Q R S

ARCHITECT

WER Architects/Planners

/1

/2

:0

:1

A

M

C U s e rs

\a s a n d e rs o n

\D o c u m e n ts \F

D A

ID

I2

.0

-F

D A

B u ild in g

C o n s t D o c s v a s a n d e rs o n

W E

.r v t

FDA Jefferson

Laboratories

BLDG. 62

RENOVATIONS

3900 NCTR Road, HFT_324

Jefferson, AR 72079

MEPFP ENGINEERS

Energy Engineering Consultants, Inc 10 Corporate Hill Dr Little Rock, AR 72205 501-244-0511

A8.06

ROOF DETAILS

03/24/22

FDAIDI21.01

OWNER

FDA

Jefferson Laboratories

OAGS - Field Operations Branch 3900 NCTR Road Jefferson, AR 72079

P ro je c t

N a m e

ISSUE FOR CONSTRUCTION

3" = 1'-0" M14

EXISTING ROOF DRAIN TO BE REFLASHED

1 : 5 M10

Roof-To-Wall Flashing - 2030

1 1/2" = 1'-0" M4

EQUIPMENT CURB AT ABANDONED EQUIPMENT

1 1/2" = 1'-0" F14

GUTTER DETAIL

No. Issue Date

Copyright

Date

Title

Sheet No.

901 West Third Street Little Rock, Arkansas 72201 501.374.5300

Seal

Job No.

www.WERarch.com

SRQPNMLKJHGFEDCBA

A B C D E F G H J K L M N P Q R S

ARCHITECT

WER Architects/Planners

/1

/2

:0

:2

A

M

C U s e rs

\a s a n d e rs o n

\D o c u m e n ts \F

D A

ID

I2

.0

-F

D A

B u ild in g

C o n s t D o c s v a s a n d e rs o n

W E

.r v t

FDA Jefferson

Laboratories

BLDG. 62

RENOVATIONS

3900 NCTR Road, HFT_324

Jefferson, AR 72079

MEPFP ENGINEERS

Energy Engineering Consultants, Inc 10 Corporate Hill Dr Little Rock, AR 72205 501-244-0511

A9.00

REFERENCE

DRAWINGS

03/24/22

FDAIDI21.01

OWNER

FDA

Jefferson Laboratories

OAGS - Field Operations Branch 3900 NCTR Road Jefferson, AR 72079

P ro je c t

N a m e

ISSUE FOR CONSTRUCTION

1" = 1'-0"

REFERENCE DRAWING1

THIS DRAWING IS FOR REFERENCE ONLY, NOT PART OF WORK SCOPE

Copyright

Date

Title

Sheet No.

901 West Third Street Little Rock, Arkansas 72201 501.374.5300

Seal

Job No.

www.WERarch.com

SRQPNMLKJHGFEDCBA

A B C D E F G H J K L M N P Q R S

ARCHITECT

WER Architects/Planners

/1

/2

:0

:2

A

M

C U s e rs

\a s a n d e rs o n

\D o c u m e n ts \F

D A

ID

I2

.0

-F

D A

B u ild in g

C o n s t D o c s v a s a n d e rs o n

W E

.r v t

FDA Jefferson

Laboratories

BLDG. 62

RENOVATIONS

3900 NCTR Road, HFT_324

Jefferson, AR 72079

MEPFP ENGINEERS

Energy Engineering Consultants, Inc 10 Corporate Hill Dr Little Rock, AR 72205 501-244-0511

A9.01

REFERENCE

DRAWINGS

03/24/22

FDAIDI21.01

OWNER

FDA

Jefferson Laboratories

OAGS - Field Operations Branch 3900 NCTR Road Jefferson, AR 72079

P ro je c t

N a m e

ISSUE FOR CONSTRUCTION

1" = 1'-0"

REFERENCE DRAWING2

THIS DRAWING IS FOR REFERENCE ONLY, NOT PART OF WORK SCOPE

File details come from the government source that posted it. Updated .