Amendment 1 Attachment 2 A1.02 22.09.12 UPDATE.pdf
PDF 595 KB Posted
- Attached to
- Building 62 Renovation Federal contract opportunity
- Solicitation number
- 75F40122R00086
About this file
This document provides plans for the Building 62 Renovation project for the Department of Health and Human Services Food and Drug Administration. The project includes renovations to the ground floor including removing and replacing doors, patching and finishing walls, installing stainless steel wall protection, infilling walls, adding concrete stoops and landings, relocating roof drains, and tying storm drains and downspouts into the existing underground system. Mechanical, electrical, and plumbing plans will be updated according to Specification Section 14 2201. Bidders should visit the site as outlined in Section L-11 of the solicitation to familiarize themselves with the existing conditions and scope of work.
View the file
Other files for this federal contract opportunity
Show all 30
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F.E .C
F.E .C
A B C D EX
A4.02
G14
LARGE HOLDING
BEHAVIOR
LAB/HOLDING
LRG BREEDING
LRG FARROW
LRG HOLD
PROCESSING
STAIR
RECORDS
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
TLT
D GOWN
173A
CIRC
196B
HOLDING
HOLDING
HOLDING
CIRC
170B
CLEAN CORR
170A
CLEAN WASH
ISOLATION
DOSING
LAB SUPT
JAN
FOOD STOR
GOWN
SURGERY
SURGERY PREP
RECOVERY
NECROPSY
AIR LOCK
BEHAVIOR
WET LAB
PET LAB
MRI PREP
DIRTY CORR
CLEAN CORR
UTILITY
TLT
JAN
TLT
STOR
PROCESSING
STOR
TREATMENT
MRI
LAB GAS
MECHANICAL
EQUIP
WAITING
CONTROL
CORRIDOR
100A
TLT
DIRTY CORR
196A
DIRTY WASH
ELEV
E
NHP HOLDING
02 02
149A
149B
152A 152B
151B
150B150A
151A
15'-3 3/4" 1'-4" 54'-10" 7'-6"
A1.004A1.00 5
A1.11
C3C
C3D
/4
AFX-1
11'-1"
6'-4 5/8" 11'-5 1/2"
43'-5 1/4"
13FFE 274.19'
FFE 274.74'
EXISTING AREA/YARD
DRAIN - REPAIRED. SEE
MEP
S L O
P E
SLOPE
CORRIDOR
C3
MH
C3A
C3B
3A
3A
C4
8'-0"
6B
6B
S L O
P E
2A
C1
141A 141B
143A 143B
6B 6B
6B 6B
/4
S L O
P E
D O
W N
T O
B U
IL
D
IN
G
SLOPE
1. ALL MASONRY DIMENSIONS ARE NOMINAL, NOT ACTUAL.
2. ALL OTHER DIMENIONS ARE TO FACE OF STUD (F.O.C.) OR GRIDLINE UNLESS NOTED
OTHERWISE. CONTRACTOR IS TO VERIFY ALL DIMENIONS PRIOR TO CONSTRUCTION. COORDINATE ALL TRADES TO AVOID ANY DIMENSIONAL DISCREPANCIES. CONTACT ARCHITECT FOR DIMENSIONS NOT SHOWN.
3. AT EXPOSED SEALED OR POLISHED CONCRETE FLOORS, VERIFY CONTROL JOINT LOCATIONS/PATTERN
WITH ARCHITECT.
4. REFER TO ENLARGED PLANS FOR ADDITIONAL DIMENSION INFORMATION.
5. REFER TO FLOOR PATTERN PLANS AND FINISH SCHEDULE FOR FINISHES AND FLOOR FINISH PATTERNS
FLOOR PLAN - GENERAL NOTES:
/1 A101
ROOM NAME
DOOR NUMBER
ROOM NUMBER
VIEW NUMBER / SHEET
LOCATION
A101
SIM
SECTION NUMBER
SHEET
LOCATION
A.F.F.
1i
1'-0"
A101
SIM
COLUMN
GRID
CEILING
MATERIAL
CEILING
HEIGHT
DETAIL
NUMBER
SHEET
LOCATION
REFERENCE
ELEVATION
FLOOR PLAN LEGEND
AL-XX FRAME
TYPE
Level Name
Elevation
1 REVISION
TAG
A100 A1 ELEVATION
TAG
1A PARTITION
TYPE
B.B.
FIRE EXTINGUISHER
CABINET
BULLETIN
BOARD
C.G. CORNER
GUARD
FIRE
EXTINGUISHER
F.E.
TOILET ACCESSORY
TYPE
TA-1
FEC
ROOM
Copyright
Date
Title
Sheet No.
901 West Third Street Little Rock, Arkansas 72201 501.374.5300
Seal
Job No.
www.WERarch.com
SRQPNMLKJHGFEDCBA
A B C D E F G H J K L M N P Q R S
ARCHITECT
WER Architects/Planners
/1
/2
:0
:0
A
M
C U s e rs
\a s a n d e rs o n
\D o c u m e n ts \F
D A
ID
I2
.0
-F
D A
B u ild in g
C o n s t D o c s v a s a n d e rs o n
W E
.r v t
FDA Jefferson
Laboratories
BLDG. 62
RENOVATIONS
3900 NCTR Road, HFT_324
Jefferson, AR 72079
MEPFP ENGINEERS
Energy Engineering Consultants, Inc 10 Corporate Hill Dr Little Rock, AR 72205 501-244-0511
A1.02
NEW
CONSTRUCTION
PLANS
03/24/22
FDAIDI21.01
OWNER
FDA
Jefferson Laboratories
OAGS - Field Operations Branch 3900 NCTR Road Jefferson, AR 72079
P ro je c t
N a m e
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"
GROUND FLOOR NEW
KEYNOTE - PLAN
# User Keynote Text
01 TEMPORARY CONSTRUCTION BARRIER - SEE DETAILS
02 STAINLESS STEEL WALL PROTECTION - CONTINUOUS ON ALL CORRIDOR WALLS
WITH RADIUS CORNERS. PROVIDE FASTENING AS REQUIRED BY MANUF FOR
VARIED WALL TYPES.-MOUNT AT 36" AFF TO CENTER.
03 4" CONCRETE STOOP ON GRADE - SLOPE AWAY FROM BUILDING
04 PATCH WALL AT DOOR DEMO LOCATION. FINISH FLUSH WITH ADJACENT
SURFACES
05 INFILL WITH CMU WALL AND ALIGN W/ ADJACENT WALLS.RECONFIGURE STEEL
LINTEL FOR NEW OPENING. REFER TO A9.01 AND 9.02 FOR EXISTING
CONDITIONS.
06 GENERATOR AND GENERATOR ACCESS- COORDINATE WITH MCC PROJECT
SCOPE
07 THIS AREA GRAVELED AS PART OF ANOTHER PROJECT - PROTECT
08 EXPANSION JOINT -SIM. OR EQUAL TO JOINTMASTER 615 2"
09 6"x6" PREFINISHED ALUMINUM DOWNSPOUT AND CONCRETE SPLASH BLOCK -
COORDINATE W/ SEPARATE PROJECT IN THIS AREA FOR GRADING. SLOPE SO
WATER MOVES AWAY FROM BUILDING
10 CONCRETE LANDING - PROTECT
11 INLET DRAIN - PROTECT
12 SWITCHGEAR AND ENCLOSURE- COORDINATE WITH MCC PROJECT SCOPE
13 #4 x 2'-0" DOWELS @ 12" O.C. INTO EXISTING SLAB WITH HILTI HIT-HY200
ADHESIVE. IMBED 8" MIN., GREASE/OIL OPPOSITE END
14 DUCTILE IRON YARD DRAIN BASIN 2' x 2' GRATE ASSEMBLY. - TIE INTO EXISTING
STORM DRAIN VIF INLET AND OUTLET OF EXISTING STORM MANHOLES AND
INLETS TO ASSURE PROPER DRAINAGE
15 DOWNSPOUT CONNECTOR ONTO EXISTING DOWNSPOUT LEADER - TIE INTO
UNDERGROUND INLET
18 GRAVEL TO MATCH SITE GRAVEL FINISH ON EAST SIDE OF CORRIDOR
19 ROOF DRAIN CONNECTION - RELOCATE ROOF DRAIN CONNECTION TO EAST
SIDE OF CORRIDOR AND TIE INTO UNDERGROUND INLET
20 6"x6" PREFINISHED ALUMINUM DOWNSPOUT - TIE INTO UNDERGROUND STORM
DRAIN DOWNSPOUT ADAPTER AND 8" ADS N-12 ST PIPE
100 NO WORK THIS AREA
No. Issue Date asanderson Callout
REFER TO SPECIFICATION SECTION 14 2201 FOR UPDATED ELEVATOR RENOVATION.
REMOVE AND OR RETAIN EXISTING ELEVATOR SYSTEM COMPONENETS AS LISTED IN SPECIFICATION.
File details come from the government source that posted it. Updated .