This solicitation seeks proposals for the renovation of Building 62. The Department of Health and Human Services Food and Drug Administration Office of Acquisition and Grant Services is soliciting proposals under number 75F40122R00086 to renovate Building 62, as detailed in the attached drawings and solicitation documents. Interested parties should review the solicitation documents and Section L-11 for information on an optional site visit. Proposals are due by the date specified in the solicitation documents. The award will be granted to the responsible offeror whose offer conforms to the solicitation and is most advantageous to the government considering only price and other factors specified elsewhere in the solicitation.
View the file
Other files for this federal contract opportunity
Show all 30
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEE SCHEDULE FOR OVERALL
DIMENSIONS & DOOR MATERIAL
AA CC
SCWD - SOLID CORE WOOD
HM - HOLLOW METAL
ALUM - ALUMINUM
SS- STAINLESS STEEL
PAIR, FLUSH PAIR, HALF GLASS
DOOR TYPES
1/4" = 1'-0"
C
VISION GLASS
12" x 12" VIEW PANEL. RED FILM
BETWEEN DOUBLE TEMPERED
GLAZING
A
FLUSH
HM-2
FRAME TYPES
1/4" = 1'-0"
HOLLOW METAL
FRAMES
ALUMINUM FRAMES
S E
E S
C H
E D
SEE SCHED
AL-1
S E
E S
C H
E D
SEE SCHED.
HM - HOLLOW METAL
AL - ALUMINUM
NOTE: AT MASONRY
OPENINGS PROVIDE 4"
HEAD
STAINLESS STEEL
SS
S E
E S
C H
E D
SEE SCHED.
NOTE: AT MASONRY
OPENINGS PROVIDE 4"
HEAD
CMU BOND BEAM
DOOR, SEE SCHED.
FRAME BEYOND
BACKER ROD AND
SEALANT
EQ.
STAINLESS STEEL DOOR
HEAD
5 5/8"
FRAME IS ALWAYS FLUSH
WITH INSIDE OF HOLDING
ROOM
CMU
DOOR, SEE
SCHED.
JAMB ANCHORS, MIN. 3
PER\JAMB
STAINLESS STEEL
DOOR JAMB
5 5/8"
BACKER ROD AND
SEALANT
STANDING SURFACE
SAFETY GLASS
LOCATIONS
GLASS SCHEDULE FOR WALLS AND DOORS
NP - NOT PERMITTED
A - ACCEPTABLE
NR - NOT RECOMMENDED
FIRE-RATED
NON- FIRE-RATED
A N
N E A
LE
D
W
IR
E D
T E
M P
E R
E D
LA
M
IN
A T E D
F
IR
E -R
A T E
D
SAFETY NOT REQUIRED
SAFETY REQUIRED
SAFETY NOT REQUIRED
SAFETY REQUIRED
A
NOT ALL CONDITIONS SHOWN BELOW ARE
APPLICABLE TO THE SCOPE OF WORK.
A A A A
AA
A
ANP
NPNP
NPNP
NP
NP NP
NP
NR
NR
S.G. S.G.
WET AREAS CLOSE PROXIMITY
TO DOORS
GLAZED OPENINGS IN
DOORS
GLAZED OPENINGS IN PARTITIONS
3'-0"
(S
E E
N O
T E
WALKING
SURFACE
EXTERIORINTERIOR
FLOOR
SAFETY
BARS
" EXTERIORINTERIOR
FLOOR
SAFETY
BARS
GRADE
' M
A X
SAFETY GLAZING IS REQUIRED FOR:
SAFETY GLASS IS REQUIRED WHEN THE FOLLOWING CONDITIONS
ARE PRESENT:
- TOP OF GLAZING IS GREATER THAN OR EQUAL TO 36" AFF
-AREA OF SINGLE PANE IS GREATER THAN 9 SF
-BOTTOM OF GLAZING IS LESS THAN OR EQUAL TO 18" AFF
-WALKING SURFACE IS LOCATED WITHIN 36" OF ONE OR BOTH
SIDES
EXCEPTION:
GLASS DOES NOT NEED TO BE SAFETY GLASS WHEN 1 1/2" SAFETY
BAR IS INSTALLED WHERE WALKING SURFACE IS WITHIN 36" OF
GLASS.
SAFETY GLASS IS REQUIRED AT INTERIOR LITE WHEN BOTTOM
OF GLAZING IS LESS THAN OR EQUAL TO 18" AFF.
EXCEPTION:
INTERIOR LITE DOES NOT NEED TO BE SAFETY GLASS
WHEN 1 1/2" SAFETY BAR IS INSTALLED
SAFETY GLASS IS REQUIRED FOR EXTERIOR LITES EXCEPT
WHEN
THE BOTTOM OF THE GLAZING IS GREATER THAN OR EQUAL TO
FEET ABOVE GRADE.
ANY GLASS AROUND THESE AREAS AT
60" OR LESS ABOVE THE STANDING
SURFACE IS TO BE SAFETY GLASS.
SAFETY GLASS IS TO BE USED FOR ALL
DOORS AT HOT TUBS, WHIRLPOOLS,
SAUNAS, STEAM ROOMS, BATH TUBS OR
SHOWERS.
S.G. S.G.
S.G. S.G.
60"
60"
24"
GROUND FLOOR
277'-2"
6'-6"
3'-3" 3'-3"
AFX-1
FINISH SCHEDULE LEGEND
ACF ACOUSTICAL FABRIC
ACT ACOUSTIC CEILING TILE
BRD MARKER BOARD/ CHALKBOARD
CGD CORNER GUARD
CPT CARPET
CRT CERAMIC TILE
CTB CERAMIC TILE BASE
EPC EPOXY RESIN COUNTER SURFACE
EPX QUARTZ EPOXY RESINOUS FLOORING
EXS EXISTING FINISH
FMH FUME HOODS
FXS FIXED SEATING
GDC GROUND CONCRETE
GRT GROUT
HPL PLASTIC LAMINATE
IPT INTERIOR PAINT
IPX INTERIOR EPOXY PAINT
LVT LUXURY VINYL TILE
MBL MARBLE
PCT PORCELAIN TILE
PRP PLASTIC RESIN PANEL
PTB PORCELAIN TILE BASE
RBB RUBBER BASE
RBT RUBBER TILE
SDC STATIC DISSIPATIVE CONCRETE
SDT STATIC DISSIPATIVE TILE
SLC SEALED CONCRETE
SPF SPORTS FLOOR
SSC SOLID SURFACE
SWC SPECIALTY WALL COVERING
TLP TOILET PARTITION
VCT VINYL COMPOSITION TILE
VWC VINYL WALL COVERING
WDF WOOD FLOORING
WDM WOOD MILLWORK
WKM WALK-OFF MAT
WNB WINDOW BLINDS
3 1/2"
WALL - EXISTING OR NEW
CONSTRUCTION
WALL FINISH - SEE FINISH SCHEDULE
UNDERLAYMENT FLOORYING
SYSTEM
R 1 1/2"
FLOORING FINISH ON
UNDERLAYMENT WHERE REQUIRED
/2
CEMENTITIOUS FLOOR TOPPING - INSTALL
NEAT TO SLOPE TO 1" AND ADD AGGREGATE
PER MANUF FOR 4" THICK SECTIONS.
/4
EXISTING CONCRETE SLAB (SEE PLAN FOR
EXTENTS)
CONTROL JOINT AS REQUIRED
RESINOUS EPOXY FLOORING FINISH
BONDING PRODUCT AS REQUIRED BY
TOPPING SLAB MANUF.
BASE BID
GENERAL FINISH NOTES:
A. SEE INTERIOR ELEVATIONS & REFLECTED CEILING PLANS FOR FULL EXTENT & LOCATION OF
MATERIALS.
B. SPECIFIC COLORS & PATTERNS TO BE PROVIDED IN SPREADSHEET FORMAT PENDING
CLIENT APPROVAL.
C. HATCH PATTERNS INDICATING FLOORING MATERIALS AND FINISHES ARE FOR
INFORMATIONAL PURPOSES ONLY AND ARE NOT INTENDED TO INDICATE THE FULL EXTENT
OF MATERIALS. HATCH PATTERNS DO NOT REPRESENT PRECISE PLACEMENT OF PATTERNS
AND MAY BE SUBJECT TO CHANGE. REFER TO FINISH SCHEDULE FOR FULL EXTENT AND
LOCATION OF MATERIALS.
D. WHERE LIKE MATERIALS TRANSITION AT DOORWAYS AND CASED OPENINGS, CONTINUE THE
PRODUCT INSTALLATION SEAMLESSLY THROUGH THE OPENING, CENTERED AT THRESHOLD.
DO NOT USE RUBBER OR MARBLE TRANSITION STRIPS UNLESS OTHERWISE NOTED. WHERE
VCT OR EPX ABUT DIFFERENT FLOORING MATERIALS, USE REDUCER (OR FEATHERSTONE
NO LESS THAN 12" FROM EDGE OF MATERIAL) TO RAISE FINISHED HEIGHT OF ADJACENT
FLOORING. WHERE EPX SELF COVE BASE IS LOCATED, USE SCHULTER SCHIENE AT TOP
CAP, INSTALLER TO DETERMINE APPROPRIATE SIZE/SHAPE.
E. PAINT FINISHES SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED:
WALLS: IPX (INTERIOR EPOXY PAINT) OR IPT (INTERIOR PAINT)
TRIM: SEMI-GLOSS
CEILINGS: IPX (INTERIOR EPOXY PAINT)
F. WHERE EXISTING FINISHES ARE NOTED, CARE AND CAUTION SHALL BE TAKEN TO PROTECT
AND PRESERVE SAID FINISHES DURING THE CONSTRUCTION PROCESS. EXISTING CARPET
TILES ARE TO BE REMOVED WITH CARE SO AS TO ENABLE THEIR RE-USE IN OTHER
LOCATIONS AS NOTED.
G. WHERE DEMOLITION OCCURS AT ANY WALL, THE AREA IS TO BE REFINISHED, PRIMED AND
REPAINTED TO MATCH EXISTING OR ADJACENT SURFACES, OR AS OTHERWISE DIRECTED BY
ARCHITECT.
H. PROVIDE 1/2" SOLID SURFACE SILLS AT WINDOWS. BASIS OF DESIGN: CORIAN, COLOR TBD.
Copyright
Date
Title
Sheet No.
901 West Third Street Little Rock, Arkansas 72201 501.374.5300
Seal
Job No.
www.WERarch.com
SRQPNMLKJHGFEDCBA
A B C D E F G H J K L M N P Q R S
ARCHITECT
WER Architects/Planners
/1
/2
:0
:1
A
M
C U s e rs
\a s a n d e rs o n
\D o c u m e n ts \F
D A
ID
I2
.0
-F
D A
B u ild in g
C o n s t D o c s v a s a n d e rs o n
W E
.r v t
FDA Jefferson
Laboratories
BLDG. 62
RENOVATIONS
3900 NCTR Road, HFT_324
Jefferson, AR 72079
MEPFP ENGINEERS
Energy Engineering Consultants, Inc 10 Corporate Hill Dr Little Rock, AR 72205 501-244-0511
A7.02
SCHEDULES
03/24/22
FDAIDI21.01
OWNER
FDA
Jefferson Laboratories
OAGS - Field Operations Branch 3900 NCTR Road Jefferson, AR 72079
P ro je c t
N a m e
ISSUE FOR CONSTRUCTION
Door Schedule
Door Number
DOOR FRAME
U.L. Label Hardware
Set CommentsType Door
Material
Size Frame TypeWidth Height
141A C SS 4'-0" 7'-0" SS 30 MIN RED FILM GLAZING
141B C SS 4'-0" 7'-0" SS 30 MIN RED FILM GLAZING
143A C SS 4'-0" 7'-0" SS 30 MIN RED FILM GLAZING
143B C SS 4'-0" 7'-0" SS 30 MIN RED FILM GLAZING
149A C SS 4'-0" 7'-0" SS 30 MIN RED FILM GLAZING
149B C SS 4'-0" 7'-0" SS 30 MIN RED FILM GLAZING
150A C SS 4'-0" 7'-0" SS 30 MIN RED FILM GLAZING
150B C SS 4'-0" 7'-0" SS 30 MIN RED FILM GLAZING
151A C SS 4'-0" 7'-0" SS 30 MIN RED FILM GLAZING
151B C SS 4'-0" 7'-0" SS 30 MIN RED FILM GLAZING
152A C SS 4'-0" 7'-0" SS 30 MIN RED FILM GLAZING
152B C SS 4'-0" 7'-0" SS 30 MIN RED FILM GLAZING
C1 A SS 4'-0" 7'-0" SS 30 MIN
C3A AA HM 6'-0" 7'-0" HM-2
C3B AA HM 6'-0" 7'-0" HM-2
C3C CC HM 8'-0" 8'-0" HM-2
C3D CC HM 8'-0" 8'-0" HM-2
C4 A SS 4'-0" 7'-0" SS 30 MIN
3" = 1'-0" A12
HOLLOW METAL HEAD @ HOLDING ROOMS
3" = 1'-0"
B12
HOLLOW METAL JAMB @ HOLDING ROOMS
Finish Schedule
Room Number Room Name
Floor Finish Base Finish Wall Finish Comments
141 LARGE HOLDING EPX EPX SELF COVE IPX WALL GUARDS AT GRATES, INTEGRAL COVED WALL BASE
143 NHP HOLDING EPX EPX SELF COVE IPX WALL GUARDS AT GRATES, INTEGRAL COVED WALL BASE
145 CLEAN CORR EPX EPX SELF COVE IPX PERIMETER WALL GUARDS, INTEGRAL COVED WALL BASE
146 DIRTY CORR EPX EPX SELF COVE IPX PERIMETER WALL GUARDS, INTEGRAL COVED WALL BASE
149 BEHAVIOR LAB/HOLDING EPX EPX SELF COVE IPX WALL GUARDS AT GRATES, INTEGRAL COVED WALL BASE
150 LRG BREEDING EPX EPX SELF COVE IPX WALL GUARDS AT GRATES, INTEGRAL COVED WALL BASE
151 LRG FARROW EPX EPX SELF COVE IPX WALL GUARDS AT GRATES, INTEGRAL COVED WALL BASE
152 LRG HOLD EPX EPX SELF COVE IPX WALL GUARDS AT GRATES, INTEGRAL COVED WALL BASE
156 BEHAVIOR -- PATCH MATCH EXISTING
FINISH
REPAINT
C3 CORRIDOR VCT RBB IPT
Grand total: 10
1" = 1'-0"
WALL BASE DETAIL
NOTE: ROOMS NOT ON SCHEDULE HAVE NO MAJOR WORK. WHERE MINOR FINISH PATCHING IS REQUIRED, MATCH
EXISTING ADJACENT FINISHES.
1 1/2" = 1'-0"
FLOOR SLOPE CONDITIONS
No. Issue Date
AREA L
AREA B
AREA A
1 8 3 4 5
AREA E
AREA L
REVISE ROOF DRAIN TO EAST
SIDE - SEE FLOOR PLAN
REMOVE EXISTING ROOF DRAIN
PIPING - SEE FLOOR PLAN
AREA B
AREA D
AREA C
AREA M
AREA E
AREA FAREA G
AREA H
1 REMOVE EXISTING COUNTER FLASHING. TURN NEW MEMBRANE AND FLASHING PLIES UP WALL PER DETAIL AND INSTALL NEW CONTINUOUS TERMINATION BAR WITH ANCHORS @ 12" O.C. MIN. AND CONTINUOUS SEALANT.
2 EXISTING SIDING TO REMAIN. REFLASH AT WALL-TO- ROOF CONATIONS AS DESCRIBED IN KEYED NOTE #12.
3 EXISTING ROOF DRAINS TO REMAIN - TYPICAL. REPLACE EXISTING STRAINER WITH NEW. REFLASH DRAIN PER DETAILS AND
IN ACCORDANCE WITH ROOF MFR'S RECOMMENDATIONS.
4 EXISTING VTR (VENT THRU ROOF) TO REMAIN. PROVIDE NEW FLASHING KIT PER MFR'S RECOMMENDATIONS. EXTEND
HEIGHT AS REQUIRED FOR ROOF WARRANTY.
5 EXISTING EXHAUST AND/OR FRESH AIR INTAKE HOOD. RAISE EXISTING CURB AS REQUIRED TO ACCOMMODATE NEW
INCREASED ROOF SYSTEM THICKNESS.
6 REMOVE EXISTING FASCIA AND REPLACE WITH NEW FASCIA PER DETAILS. COLOR TO BE SELECTED FROM MANUFACTURER'S
STANDARD COLOR LINE - TYPICAL AT ROOFS BEING REPLACED.
7 EXISTING METAL STANDING SEAM ROOF TO REMAIN - NOT IN SCOPE OF WORK. PROTECT FROM DAMAGE.
8 EXISTING ROOF TO BE REPLACED. REFER TO ROOF PLAN FOR ROOFTOP EQUIPMENT.
9 HATCHED AREA NOT IN SCOPE.
10 FREESTANDING CANOPY, COLUMNS, RAILINGS AND SLAB TO BE REMOVED. SEE ADD ALTERNATES
11 THIS ROOF NOT IN SCOPE.
12 REMOVE EXISTING TERMINATION BAR AND FLASHING. REPLACE WITH NEW MEMBRANE FLASHING AND TERMINATION BAR.
PROVIDE CONTINUOUS SEALANT AT TOP OF TERMINATION BAR - CONTINUOUS AT ENTIRE LENGTH OF WALLS.
13 EXISTING METAL SIDING TO REMAIN - NOT IN SCOPE OF WORK. PROTECT FROM DAMAGE.
14 CONTRACTOR IS RESPONSIBLE FOR TEMPORARILY RAISING PIPING AS MAY BE NECESSARY TO PERFORM TEAR-OFF AND
REROOF.
15 REFER TO MCC PROJECT FOR NEW GENERATOR LOCATION. PROTECT DURING CONSTRUCTION.
16 REPLACE EXISTING GUTTER AND DOWNSPOUTS WITH NEW PREFINISHED ALUMINUM GUTTER AND DOWNSPOUTS. COLOR TO
BE SELECTED BY OWNER FROM MANUFACTURER'S STANDARD COLOR LINE.
17 NOT USED.
18 EXISTING ROOFTOP UNIT TO REMAIN. REFLASH SUPPORTS WITH LIQUID-APPLIED FLASHING.
19 REMOVE EXISTING METAL COPING. REPLACE WITH NEW PREFINISHED METAL COPING TO MATCH COLOR AND PROFILE.
EXTEND FLASHING UP AND OVER PARAPET BENEATH COPING PER DETAILS. PROVIDE NEW JOINT COVERS.
20 EXISTING FLUE , EXHAUST, AND/OR AIR-INTAKE TO REMAIN. REFLASH WITH LIQUID-APPLIED FLASHING.
21 REFLASH EXISTING DUCT PENETRATION CURB PER DETAIL.
22 REFER TO NOTES ON PHOTO 13 FOR ROOF AREAS B, C & D.
23 REFER TO NOTES ON PHOTO 1 FOR ROOF AREA E.
24 REFER TO NOTES ON PHOTO 17 FOR ROOF AREA F.
25 EXISTING LADDER TO REMAIN.
26 REMOVE EXISTING GUTTER AND REPLACE WITH NEW GUTTER WITH COLOR AND PROFILE TO MATCH EXISTING.
27 REMOVE EXISTING PIPE PITCH POCKET. INSTALL NEW PIPE PENETRATION ENCLOSURE SIMILAR TO DETAIL P9/A8.05. REFLASH
WITH LIQUID-APPLIED FLASHING.
28 REMOVE EXISTING DOWNSPOUT AND REPLACE WITH NEW PRE-FINISHED METAL DOWNSPOUT.
29 REMOVE CONCRETE SPLASHBLOCK. REPLACE WITH ALUMINUM SPLASHBLOCK. PROVIDE EXTRA MEMBRANE PAD BENEATH
SPLASHBLOCK. ADHERE PER MFR'S RECOMMENDATIONS..
30 EXISTING DRAIN LINE TO REMAIN. TEMPORARILY RAISE LINE AS REQUIRED DURING REROOF.
31 TEMPORARILY REMOVE CONDUIT FOR FLASHING AND COPING REMOVAL AND REINSTALLATION. REINSTALL CONDUIT AFTER
COPING IS COMPETE.
32 EXISTING EXHAUST FLUE OR FRESH AIR INTAKE TO REMAIN. REFLASH PER DETAIL.
33 REMOVE EXISTING MOISTURE RELIEF VENT (MRV) AND REPLACE WITH NW MOISTURE RELIEF VENT.
34 EXISTING EXHAUST FAN TO REMAIN. RAISE EXISTING CURB AS REQUIRED TO ACCOMMODATE NEW INCREASED ROOF
SYSTEM THICKNESS.
35 EXISTING ROOFTOP CONDENSER TO REMAIN. RAISE EXISTING CURB AS REQUIRED TO ACCOMMODATE NEW INCREASED
ROOF SYSTEM THICKNESS.
36 REMOVE EXISTING EXPANSION JOINT AND REPLACE WITH NEW PER DETAIL.
37 REFLASH EXISTING PITCH POCKETS WITH LIQUID-APPLIED FLASHING AT EXISTING DUCTWORK AND PIPING SUPPORTS.
PROVIDE NEW UMBRELLA AT EACH SUPPORT.
38 EXISTING DUCTWORK AND PIPING TO REMAIN. PROTECT FROM DAMAGE. CONTRACTOR IS RESPONSIBLE FOR TEMPORARILY
RAISING PIPING AS MAY BE NECESSARY TO PERFORM TEAR-OFF AND REROOF.
39 REFER TO NOTES ON PHOTO 30 FOR ROOF AREA A.
40 EXISTING ROOFTOP UNIT TO REMAIN. RAISE EXISTING STEEL BEAM SUPPORTS AS REQUIRED FOR NEW ROOF THICKNESS.
REFLASH SUPPORTS WITH LIQUID-APPLIED FLASHING.
41 CIRCLED AREAS AT BRICK WALLS INDICATE MORTAR JOINT AND SEALANT ISSUES REQUIRING ATTENTION. INSPECT WALL, REMOVE SEALANT AND TUCKPOINT WITH NP-1 URETHANE SEALANT OR SIM.
42 CIRCLED AREAS AT BRICK WALLS INDICATED AREAS REQUIRING HELICAL MASONRY STITCHING TIES AND MASONRY PINNING.
KEYED NOTES FOR ROOF PHOTOS
CLEAN ALL EXISTING MASONRY WALLS WITH LOW WATER PRESSURE (100 TO 400 PSI) AND AS REQUIRED FOR FINISH. COAT ALL MASONRY WALLS WITH ELASTOMERIC COATING. SIM. OR EQUAL TO EL 750 ELASTOMERIC COATING. (APPROXIMATELY 20,000 SF OF
WALL SURFACE)
PROVIDE UNIT COSTS FOR OPEN JOINTS IN GROUT LARGER THAN 1/4" AND NOT SPECIFICALLY IDENTIFIED IN DRAWINGS.
PROVIDE UNIT COSTS FOR AREAS NOT IDENTIFIED ON DRAWINGS THAT MAY REQUIRING HELICAL TIES.
NOTES:
Copyright
Date
Title
Sheet No.
901 West Third Street Little Rock, Arkansas 72201 501.374.5300
Seal
Job No.
www.WERarch.com
SRQPNMLKJHGFEDCBA
A B C D E F G H J K L M N P Q R S
ARCHITECT
WER Architects/Planners
/1
/2
:0
:1
A
M
C U s e rs
\a s a n d e rs o n
\D o c u m e n ts \F
D A
ID
I2
.0
-F
D A
B u ild in g
C o n s t D o c s v a s a n d e rs o n
W E
.r v t
FDA Jefferson
Laboratories
BLDG. 62
RENOVATIONS
3900 NCTR Road, HFT_324
Jefferson, AR 72079
MEPFP ENGINEERS
Energy Engineering Consultants, Inc 10 Corporate Hill Dr Little Rock, AR 72205 501-244-0511
A8.01
REFERENCE
PHOTOS
03/24/22
FDAIDI21.01
OWNER
FDA
Jefferson Laboratories
OAGS - Field Operations Branch 3900 NCTR Road Jefferson, AR 72079
P ro je c t
N a m e
ISSUE FOR CONSTRUCTION
PHOTO 1 PHOTO 2 PHOTO 3
PHOTO 4 PHOTO 5 PHOTO 6
PHOTO 7 PHOTO 8 PHOTO 9
PHOTO 10 PHOTO 11 PHOTO 12
REMOVE EXISTING ROOF DRAIN
PIPING - SEE FLOOR PLAN
AREA DRAINS - SEE FLOOR PLAN