Attachment 2 - Drawings Work Area and Door Install Comb.pdf

PDF 2 MB Posted

Attached to
Repair SCIF BLDG 150 Federal contract opportunity
Solicitation number
W50S8Q-23-B-0004
Issued by
Department of the Army National Guard

About this file

This document includes drawings and specifications for a security installation project at Building 150. The project involves demolishing an existing vault door and frame and installing a new hollow metal door and frame. Additional work includes installing a new maglock, request to exit button, card reader, emergency power off button, white noise speakers, and PIR sensor to secure an area within the building. All security control panels, junction boxes and devices must communicate with the base defense operations center and security room. The contractor will be required to use Advantor for the security aspects of the work. The contractor will provide labor, materials and equipment to complete the job according to the drawings and statement of work, running no less than 3/4" conduit and installing 4x4 junction boxes. The contractor must also supply power circuits and perform testing with the government to ensure proper system operation before providing training.

View the file

Other files for this federal contract opportunity

Other files attached to Repair SCIF BLDG 150, newest first.
File Type Posted
Abstract of Offers1419_W50S8Q23B0004.pdf PDF
RFI_W50S8Q23B0004_SCIFDoor.pdf PDF
W50S8Q-23-B-0004 Repair SCIF Door.pdf PDF
Attachment 4 - RFI Format.docx DOCX document
Attachment 1 - SOW Bldg.150 ISRG door WAAR232004.docx DOCX document
Attachment 3 - Material Submittals ISRG Complete.xlsx XLSX spreadsheet
Attachment 5 - DBIDs -Base Entry Request.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ML

O

TRAVEL

95'-0"

BLDG EXIT

1/100 B

0.2" 68"340

EXIT

1/100 B

0.2" 34"170

FE

FE

TRAVEL

126'-0"

BLDG EXIT

1/100 B

0.2" 34"170

UP

EXISTING

COMBAT

OPERATIONS

EXISTING

OPEN

OFFICE

EXISTING

ENTRY

SECURITY

OFFICE

VEST

OFFICE

OFFICE

129 OFFICE

OPEN

OFFICE

EXISTING

MAIN

WAREHOUSE

SERVER/

COMM ROOM

EXISTING

FLAMMABLES

LIFE SAFETY PLAN

SCALE: 1/8"=1'-0"

NORTH

LEGEND

DENOTES EXIT

ROUTE

TRAVEL

DISTANCE

START

POINT

EGRESS ELEMENT

USE AND OCCUPANCY

CLASSIFICATION

OCCUPANT LOAD

SERVED

REQUIRED ELEMENT

WIDTH

ACTUAL EGRESS WIDTH

PROVIDED

DENOTES

FLOOR OR

BUILDING EXIT

S.F. PER OCCUPANT

SURFACE MOUNTED

FIRE EXTINGUISHER

FE

CEILING MOUNTED EXIT

SIGN

EXIT

1/100 B

0.2" 46"230

SHEET

REFERENCE

NUMBER

D

ES

IG

N

E D

B Y

: A

JD

D W

N B

Y:

A

JD

R

EV

IE

W

E D

B Y

: C

LK

D

AT

E:

D

ES

IG

N

F

IL

E N

O

D R

AW

IN

G C

O D

E:

FI

LE

N

AM

E:

P

LO

T

D A

TE

P

LO

T

SC

AL

E:

R

EV

P ar kw ay

L an e, S ui te

N or cr os s, G

A

Ph on e

8.

6.

Fa x

8.

6.

W eb : w w w

.p on dc o.

co m

R

EV

D

ES

C

R

IP

TI

O

N P

R

EP

B Y

D

AT

E A

PR

VD

D R

A W

IN

G

R

EV

IS

IO

N S

FI

N

AL

S

U

BM

IT

TA

L

A

LT

ER

B

U

IL

D

IN

G

O

H

IO

N

AT

IO

N

AL

G

U

AR

D S

PR

IN

G

FI

E

LD

M

AP

, S P

R

IN

G

FI

EL

D

, O H

IO

/1

7/

C

D

B

A

Id ea

C en te r B ou le va rd

D ay to n, O H

Ph on e

7.

1.

Fa x

7.

1.

W eb

: w w w .w oo lp er t.c om

FI

N

AL

S U

BM

IT

TA

L

-2

0-

S U

B M

IT

TE

D B

Y:

G

H C

SHEET OF 46

FOR OFFICIAL USE ONLY

TRAVEL

294'-0"

EXIT SCHEDULE

AREA

OCCUPANTS

(1/100)

NUMBER OF

EXITS

PROVIDED

EGRESS WIDTH REQUIRED EGRESS WIDTH PROVIDED

STAIRS

(0.3)

OCCUPANTS

SERVED

OTHER

(0.2)

OCCUPANTS

SERVED

TOTAL EGRESS

WIDTH

REQUIRED

TOTAL

OCCUPANTS

SERVED

STAIRS

(0.3)

OCCUPANTS

SERVED

OTHER

(0.2)

OCCUPANTS

SERVED

TOTAL EGRESS

WIDTH

PROVIDED

TOTAL

OCCUPANTS

SERVED

5,400 SF 54 2 N/A N/A 10.8" 54 10.8" 181 N/A N/A 102" 510 102" 510

DIRECTIONAL CEILING

MOUNTED EXIT SIGN

WALL MOUNTED EXIT

SIGN

APPLICABLE CODES & STANDARDS:

EXISTING BUILDING USE AND OCCUPANCY CLASSIFICATION (IBC 302.1):

MIXED USE B, S-1, H-2

EXISTING BUILDING CONSTRUCTION CLASSIFICATION (IBC 602.2):

TYPE II-B CONSTRUCTION

BUILDING ELEMENTS ARE REQUIRED TO BE FIRE RESISTANT RATED AS FOLLOWS:

FIRE SUPPRESSION SYSTEM (UFC 3-600-01 CH. 4 & 6):

PORTABLE FIRE EXTINGUISHERS (NFPA 10):

FIRE CLASSIFICATION AND TRAVEL DISTANCE:

75' TRAVEL DISTANCE - TYPE ABC

LIGHT HAZARD (LOW): 1-2A TYPE ABC PER 3000 SF, 75' MAXIMUM TRAVEL DISTANCE

ORDINARY HAZARD (MODERATE):

EXTRA (HIGH) HAZARD: 1-4A TYPE ABC PER 1000 SF, 75' MAXIMUM TRAVEL DISTANCE

FIRE & SMOKE DAMPERS (NFPA 90A):

FIRE AND SMOKE DAMPERS ARE NOT REQUIRED

DETECTION ALARM & COMMUNICATION (UFC 3-600-01 CH. 5 & NFPA 100 3.4 (CH 12-42):

AUTOMATIC FIRE ALARM SYSTEM COMPLETE WITH SOUNDERS, STROBES, PULL STATIONS

AND RADIO TRANSMITTER

INTERIOR FINISHES CLASSIFICATION (NFPA 101 CH 10.2):

EXITS: CLASS A PER ASTM E84

EXIT ACCESS CORRIDORS: CLASS A PER ASTM E84

OTHER SPACES: CLASS A OR B PER ASTM E84

MEANS OF EGRESS:

OCCUPANT LOAD (NFPA 101 TABLE 7.3.1): B - BUSINESS AREAS - 100 GROSS

EGRESS CAPACITY (NFPA 101 7.3.3.1): DOORS = 0.2" PER OCCUPANT SERVED

NUMBER OF MEANS OF EGRESS (NFPA101 7.4.1): 2 PER NFPA 101 7.4.1

DEAD END LIMITS: 50' PER NFPA 101 39.2.5.2

COMMON PATH OF TRAVEL: 100' PER NFPA 101 39.2.5.3.1

TRAVEL DISTANCE TO EXITS: 300' PER NFPA 101 39.2.6.3

DISCHARGE FROM EXITS (NFPA 101 7.7.2): PLAN COMPLIES

ILLUMINATION OF MEANS OF EGRESS (NFPA 101 7.8): 1FC MINIMUM REQUIRED

EMERGENCY LIGHTING (NFPA 101 7.9 - 7.10): BATTERY BACKUP LIGHTS ARE PROVIDED

ACCESSIBILITY REQUIREMENTS:

BUILDING IS ACCESSIBLE PER UFC 3-600-01 CH. 1

BUILDING IS ACCESSIBLE PER UFAS

BUILDING IS ACCESSIBLE PER ADAAG

A COMPLETE AUTOMATIC SPRINKLER SYSTEM WILL BE PROVIDED -

DESIGN PER NFPA 13 AND UFC 3-600-01.

- UNITED FACILITIES CRITERIA (UFC): 1-200-01 - GENERAL BUILDING REQUIREMENTS,

NOVEMBER 27, 2007

- IC TECH SPEC FOR ICD / ICS 705 - OCTOBER 31, 2011

- UNITED FACILITIES CRITERIA (UFC): 3-600-01 - FIRE PROTECTION ENGINEERING FOR

FACILITIES, SEPTEMBER 26, 2006 INCLUDING CHANGE 1 JULY 14, 2009

- UNITED FACILITIES CRITERIA (UFC): 4-010-01 - DoD MINIMUM ANTITERRORISM

STANDARDS FOR BUILDINGS, OCTOBER 8, 2003

- ANG ETL 01-1-1 - AIR NATIONAL GUARD DESIGN POLICY, MARCH 2004

- INTERNATIONAL BUILDING CODE 2006 - FOR FIRE RESISTANCE REQUIREMENTS,

ALLOWABLE FLOOR AREA, BUILDING HEIGHTS AND BUILDING SEPARATION

DISTANCE REQUIREMENTS, EXCEPT AS MODIFIED BY UFC 3-600-01

- NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101-LIFE SAFETY CODE 2009

EDITION, FOR BUILDING EGRESS AND LIFE SAFETY - FOR CONFLICTS BETWEEN

IBC AND NFPA 101, CONFORM TO NFPA 101 AND APPLICABLE CRITERIA UFC

3-600-01

- UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS), AUGUST 1984 AND THE

AMERICANS WITH DISABILITIES ACT (ADAAG) AS AMENDED THROUGH JANUARY

1998.

1-2A TYPE ABC PER 1500 SF, 75' MAXIMUM TRAVEL DISTANCE

CODE SUMMARY

A-003

LI

FE

S

AF

ET

Y

PL

AN

16'0 8'4'

SCALE: 1/8" = 1'-0"

CONTRACTOR Main Work Area

1410612050M Polygon

1410612050M Line

1410612050M Rectangle

1410612050M Text Box Notes 1.) CONTRACTOR shall provide all labor, material, and equipment to complete job as indicated in this Statement of work and Drawings.

2.)The CONTRACTOR shall demo out existing steel vault door and properly dispose off base.

3.)The CONTRACTOR shall demo out existing threshold and properly dispose off base.

4.) The CONTRACTOR shall install new single hollow metal door and frame and install in current door opening in room #130

5.) IF CONTRACTOR shall use CMU to fill the rough opening to fit no less than a 36” hollow metal door and frame, if needed.

6.) The CONTRACTOR shall be required to paint any CMU the gets damaged or added on too. The contractor shall match existing CMU paint as close as possible.

7.)The CONTRACTOR shall paint the door and door frame Base Facility Standard. The contractor shall properly prep door and door frame for paint to make sure it gets proper adhesion.

8.)The CONTRACTOR shall install rubber gaskets around door frame to ensure that no noise can leak out through edges of door.

9.)The CONTRACTOR shall install heavy duty door closure and hardware.

10.)The CONTRACTOR shall install a combination lock that meets Federal Specifications FF-L-2740. (For Example Kaba-Mas X-09) The CONTRACTOR shall install panic hardware on secure side of door and a L shaped handle combination that includes a mortise lock cylinder on non-secured side that can be keyed to building

11.)The CONTRACTOR shall be required to install new metal threshold under door.

1410612050M Line

1410612050M Text Box Existing vault door and frame to be demolished and replaced with new hollow metal door and frame.

ML

O

TRAVEL

95'-0"

BLDG EXIT

1/100 B

0.2" 68"340

EXIT

1/100 B

0.2" 34"170

FE

FE

TRAVEL

126'-0"

BLDG EXIT

1/100 B

0.2" 34"170

UP

EXISTING

COMBAT

OPERATIONS

EXISTING

OPEN

OFFICE

EXISTING

ENTRY

SECURITY

OFFICE

VEST

OFFICE

OFFICE

129 OFFICE

OPEN

OFFICE

EXISTING

MAIN

WAREHOUSE

SERVER/

COMM ROOM

EXISTING

FLAMMABLES

LIFE SAFETY PLAN

SCALE: 1/8"=1'-0"

NORTH

LEGEND

DENOTES EXIT

ROUTE

TRAVEL

DISTANCE

START

POINT

EGRESS ELEMENT

USE AND OCCUPANCY

CLASSIFICATION

OCCUPANT LOAD

SERVED

REQUIRED ELEMENT

WIDTH

ACTUAL EGRESS WIDTH

PROVIDED

DENOTES

FLOOR OR

BUILDING EXIT

S.F. PER OCCUPANT

SURFACE MOUNTED

FIRE EXTINGUISHER

FE

CEILING MOUNTED EXIT

SIGN

EXIT

1/100 B

0.2" 46"230

SHEET

REFERENCE

NUMBER

D

ES

IG

N

E D

B Y

: A

JD

D W

N B

Y:

A

JD

R

EV

IE

W

E D

B Y

: C

LK

D

AT

E:

D

ES

IG

N

F

IL

E N

O

D R

AW

IN

G C

O D

E:

FI

LE

N

AM

E:

P

LO

T

D A

TE

P

LO

T

SC

AL

E:

R

EV

P ar kw ay

L an e, S ui te

N or cr os s, G

A

Ph on e

8.

6.

Fa x

8.

6.

W eb : w w w

.p on dc o.

co m

R

EV

D

ES

C

R

IP

TI

O

N P

R

EP

B Y

D

AT

E A

PR

VD

D R

A W

IN

G

R

EV

IS

IO

N S

FI

N

AL

S

U

BM

IT

TA

L

A

LT

ER

B

U

IL

D

IN

G

O

H

IO

N

AT

IO

N

AL

G

U

AR

D S

PR

IN

G

FI

E

LD

M

AP

, S P

R

IN

G

FI

EL

D

, O H

IO

/1

7/

C

D

B

A

54321

Id ea

C en te r B ou le va rd

D ay to n, O H

Ph on e

7.

1.

Fa x

7.

1.

W eb

: w w w .w oo lp er t.c om

FI

N

AL

S U

BM

IT

TA

L

-2

0-

S U

B M

IT

TE

D B

Y:

G

H C

SHEET OF 46

FOR OFFICIAL USE ONLY

TRAVEL

294'-0"

EXIT SCHEDULE

AREA

OCCUPANTS

(1/100)

NUMBER OF

EXITS

PROVIDED

EGRESS WIDTH REQUIRED EGRESS WIDTH PROVIDED

STAIRS

(0.3)

OCCUPANTS

SERVED

OTHER

(0.2)

OCCUPANTS

SERVED

TOTAL EGRESS

WIDTH

REQUIRED

TOTAL

OCCUPANTS

SERVED

STAIRS

(0.3)

OCCUPANTS

SERVED

OTHER

(0.2)

OCCUPANTS

SERVED

TOTAL EGRESS

WIDTH

PROVIDED

TOTAL

OCCUPANTS

SERVED

5,400 SF 54 2 N/A N/A 10.8" 54 10.8" 181 N/A N/A 102" 510 102" 510

DIRECTIONAL CEILING

MOUNTED EXIT SIGN

WALL MOUNTED EXIT

SIGN

APPLICABLE CODES & STANDARDS:

EXISTING BUILDING USE AND OCCUPANCY CLASSIFICATION (IBC 302.1):

MIXED USE B, S-1, H-2

EXISTING BUILDING CONSTRUCTION CLASSIFICATION (IBC 602.2):

TYPE II-B CONSTRUCTION

BUILDING ELEMENTS ARE REQUIRED TO BE FIRE RESISTANT RATED AS FOLLOWS:

FIRE SUPPRESSION SYSTEM (UFC 3-600-01 CH. 4 & 6):

PORTABLE FIRE EXTINGUISHERS (NFPA 10):

FIRE CLASSIFICATION AND TRAVEL DISTANCE:

75' TRAVEL DISTANCE - TYPE ABC

LIGHT HAZARD (LOW): 1-2A TYPE ABC PER 3000 SF, 75' MAXIMUM TRAVEL DISTANCE

ORDINARY HAZARD (MODERATE):

EXTRA (HIGH) HAZARD: 1-4A TYPE ABC PER 1000 SF, 75' MAXIMUM TRAVEL DISTANCE

FIRE & SMOKE DAMPERS (NFPA 90A):

FIRE AND SMOKE DAMPERS ARE NOT REQUIRED

DETECTION ALARM & COMMUNICATION (UFC 3-600-01 CH. 5 & NFPA 100 3.4 (CH 12-42):

AUTOMATIC FIRE ALARM SYSTEM COMPLETE WITH SOUNDERS, STROBES, PULL STATIONS

AND RADIO TRANSMITTER

INTERIOR FINISHES CLASSIFICATION (NFPA 101 CH 10.2):

EXITS: CLASS A PER ASTM E84

EXIT ACCESS CORRIDORS: CLASS A PER ASTM E84

OTHER SPACES: CLASS A OR B PER ASTM E84

MEANS OF EGRESS:

OCCUPANT LOAD (NFPA 101 TABLE 7.3.1): B - BUSINESS AREAS - 100 GROSS

EGRESS CAPACITY (NFPA 101 7.3.3.1): DOORS = 0.2" PER OCCUPANT SERVED

NUMBER OF MEANS OF EGRESS (NFPA101 7.4.1): 2 PER NFPA 101 7.4.1

DEAD END LIMITS: 50' PER NFPA 101 39.2.5.2

COMMON PATH OF TRAVEL: 100' PER NFPA 101 39.2.5.3.1

TRAVEL DISTANCE TO EXITS: 300' PER NFPA 101 39.2.6.3

DISCHARGE FROM EXITS (NFPA 101 7.7.2): PLAN COMPLIES

ILLUMINATION OF MEANS OF EGRESS (NFPA 101 7.8): 1FC MINIMUM REQUIRED

EMERGENCY LIGHTING (NFPA 101 7.9 - 7.10): BATTERY BACKUP LIGHTS ARE PROVIDED

ACCESSIBILITY REQUIREMENTS:

BUILDING IS ACCESSIBLE PER UFC 3-600-01 CH. 1

BUILDING IS ACCESSIBLE PER UFAS

BUILDING IS ACCESSIBLE PER ADAAG

A COMPLETE AUTOMATIC SPRINKLER SYSTEM WILL BE PROVIDED -

DESIGN PER NFPA 13 AND UFC 3-600-01.

- UNITED FACILITIES CRITERIA (UFC): 1-200-01 - GENERAL BUILDING REQUIREMENTS,

NOVEMBER 27, 2007

- IC TECH SPEC FOR ICD / ICS 705 - OCTOBER 31, 2011

- UNITED FACILITIES CRITERIA (UFC): 3-600-01 - FIRE PROTECTION ENGINEERING FOR

FACILITIES, SEPTEMBER 26, 2006 INCLUDING CHANGE 1 JULY 14, 2009

- UNITED FACILITIES CRITERIA (UFC): 4-010-01 - DoD MINIMUM ANTITERRORISM

STANDARDS FOR BUILDINGS, OCTOBER 8, 2003

- ANG ETL 01-1-1 - AIR NATIONAL GUARD DESIGN POLICY, MARCH 2004

- INTERNATIONAL BUILDING CODE 2006 - FOR FIRE RESISTANCE REQUIREMENTS,

ALLOWABLE FLOOR AREA, BUILDING HEIGHTS AND BUILDING SEPARATION

DISTANCE REQUIREMENTS, EXCEPT AS MODIFIED BY UFC 3-600-01

- NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101-LIFE SAFETY CODE 2009

EDITION, FOR BUILDING EGRESS AND LIFE SAFETY - FOR CONFLICTS BETWEEN

IBC AND NFPA 101, CONFORM TO NFPA 101 AND APPLICABLE CRITERIA UFC

3-600-01

- UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS), AUGUST 1984 AND THE

AMERICANS WITH DISABILITIES ACT (ADAAG) AS AMENDED THROUGH JANUARY

1998.

1-2A TYPE ABC PER 1500 SF, 75' MAXIMUM TRAVEL DISTANCE

CODE SUMMARY

A-003

LI

FE

S

AF

ET

Y

PL

AN

16'0 8'4'

SCALE: 1/8" = 1'-0"

Secured Area

1410612050M Rectangle

1410612050M Rectangle

1410612050M Rectangle

1410612050M Oval

1410612050M Oval

1410612050M Rectangle

1410612050M Rectangle

1410612050M Rectangle

1410612050M Oval

1410612050M Oval

1410612050M Oval

1410612050M Text Box Legend

CR /CARD READER WITH PIN PAD

RTEB / REQUEST TO EXIT BUTTON

PIR / CEILING MOUNT PIR SENSOR 360 DEGREE

HSS / HIGH SECURITY SWITCH

SCP / SECURITY CONTROL PANEL

ML / MAGNETIC LOCK / MAG-LOCK

WNS / WHITE NOISE SPEAKERS

EPO / EMERGENCY POWER OFF BUTTON

1410612050M Rectangle

1410612050M Oval

1410612050M Oval

1410612050M Rectangle

1410612050M Rectangle

1410612050M Rectangle

1410612050M Rectangle

1410612050M Line

1410612050M Line

1410612050M Rectangle

1410612050M Line

1410612050M Line

1410612050M Oval

1410612050M Text Box Notes

ALL Contractors bidding this job shall be required to use Advantor for the security side of this work.

1.) The CONTRACTOR shall field verify all measurements prior to execution.

2.)The CONTRACTOR shall provide all labor, material, and equipment to complete job as indicated in this Statement of work and Drawings.

3.) The CONTRACTOR shall install new mag-lock, HSS,RTEB,CR,EPO, WNS and PIR. All shall be submitted and approved by COR .

3.) The CONTRACTOR shall install control panel in protected area. Verify exact location with in secured area with Government.

4.) The CONTRACTOR shall be required to install no less than 3/4" conduit or flex for this job.

5.) The CONTRACTOR shall be required to install nothing less than a 4x4 junction box with cover.

6.) The CONTRACTOR shall supply a 120V circuit for security controls.

7.) All Security Control Panels and junction boxes that contain splices or terminations shall have a tamper switch installed.

8.) All junction Boxes for security wiring and communication shall have tamper resistant security screws.

9.) The CONTRACTOR shall install white noise speakers above ceiling in locations shown.

10) The CONTRACTOR shall supply dedicate circuit to white noise speakers.

11.) The CONTRACTOR shall insure all communications and security devices communicate with BDOC at Bldg 131 as well as security room with in Bldg 150.

12.) The CONTRACTOR shall perform final test on system with Government present to insure it is working properly.

13.) The CONTRACTOR shall provide training on new security system with Security Forces and Customer.

1410612050M Line

1410612050M Text Box Existing security Control panels

10 - 150 Drawing#1 Work Area and Door Install.pdf
10 - 150 Security Install Drawing#1.pdf

File details come from the government source that posted it. Updated .