This solicitation is for the renovation of administration and maintenance buildings at the Black Hills National Cemetery. The Department of Veterans Affairs, National Cemetery Administration is seeking a 100% Service-Disabled Veteran-Owned Small Business contractor to provide all labor, materials, tools and equipment necessary to renovate and expand the Administration Building and Maintenance Building, complete repairs and modifications to the Committal Shelter, complete lighting upgrades and security upgrades, and associated work. The period of performance is 365 calendar days from notice to proceed. The estimated value is between $1,000,000 and $5,000,000. The NAICS code is 237990 and the business size standard is $39.5 million. Firms must be registered in SAM and have completed online representations and certifications to be eligible for award. The point of contact is Shane Hilts at shane.hilts@va.gov and amendments will be posted on the website rather than mailed.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF VETERANS AFFAIRS
BLACK HILLS NATIONAL CEMETERY
ADMINISTRATION BUILDING 1001 AND MAINTENANCE
BUILDING 3001 RENOVATIONS
VA PROJECT NO. 884CM3015
CONSULTANTS
ANDERSON ENGINEERING OF MN, LLC
PROJECT MANAGEMENT, CIVIL ENGINEERING,
LANDSCAPE ARCHITECTURE, ARCHITECTURE
IMEG, INC
STRUCTURAL ENGINEERING,ELECTRICAL ENGINEERING,
MECHANICAL ENGINEERING, & TECHNOLOGY/SECURITY
CPMI
COST ESTIMATOR
AET
GEOTECHNICAL ENGINEER
SITE DATA
BLACK HILLS NATIONAL CEMETERY
STREET ADDRESS:
20901 PLEASANT VALLEY DR.
STURGIS, SD 57785
COUNTY:
MEADE COUNTY
STURGIS, SOUTH DAKOTA
13605 1ST AVENUE NORTH, SUITE 100
PLYMOUTH, MN 55441
CONTACT: ERIC SAUTBINE, PE
PROJECT MANAGER
PHONE: (763) 412-4000
2882 106TH STREET
DES MOINES, IA 50322
STRUCTURAL
CONTACT: TODD BARRETT
PHONE: (515) 334-4308
ELECTRICAL
CONTACT: SCOTT KOCIAN
PHONE: (214) 485-6424
1001 GRAND AVE. SUITE 201
WEST DES MOINES, IA 50265
CONTACT: BRYAN BERTRAND
PHONE: (515) 697-1048
1745 SAMCO ROAD
RAPID CITY, SD 57702
CONTACT: JAMES REED
PHONE: (605) 388-0029
1 SITE LOCATION MAP
NTS 2 SITE VICINITY MAP
NTS
N N
SHEET INDEX
PRIME CONSULTANT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 v a nc a re no va te a dm in b ld gs b la ck h ill s nc c iv il\
_0 ca d fil es s he et s\
9_ g_ co ve r s he et .d w g ed it:
jd ob ia s sa ve d:
/3 1/
:4
P
M p lo t:1
0/
/2
1:
P
M
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15785
BLACK HILLS NATIONAL CEMETERY 884-CM-3015
10-31-22
STURGIS, SOUTH DAKOTA
BID DOCUMENTS
SUBMITTAL
Date:
RENOVATE AND EXPAND
ADMINISTRATION AND
MAINTENANCE BUILDINGS
GEOTECHNICAL
AET
1745 SAMCO RD
RAPID CITY, SD 57702
(605) 223-4397
COST ESTIMATING
CPMI
3265 NORTHWOOD CIR STE 170
EAGAN, MN 55121
(952) 854-3663
MECHANICAL, ELECTRICAL,
TECHNOLOGY & STRUCTURAL
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
(309) 786-5075
OF 84
Office of Design and Construction
(TYP)
CEMETERY
EXTENTS
PROJECT
LOCATION
HIGHW
AY 14 OLD STONE RD
BLUCKSBERG M
OUNTAIN RD
BLUCKSBERG RD
BULLDOGCANYON RD
PLEASAN
T VALLEY D
R
CIMMARON DR
HIGHW
AY 14
HIGHW
AY 14
VANOCKER CANYON RD
O
LD
STO
N
E R D
206TH STLAZELLE ST
JU
N
C
TI
O N
A V
EHIG
HW
AY 14
CATTAIL PI
FO
R
T M
E A
D E
W A
Y
207TH ST
MECHANICAL
CONTACT: WADE ROSS
PHONE: (309) 781-2103
TECHNOLOGY/SECURITY
CONTACT: JAYSON STRICKROD
PHONE: (309) 786-5092
PROJECT
LOCATION
COVER SHEET
GI-001
JDES 1
SHEET TITLE PAGE
GENERAL
GI-001 COVER SHEET 1
GI-002 TEMPORARY TRAILER LOCATIONS 2
GI002-1001 ABBREVIATIONS 3
GI111-1001 FIRST & BASEMENT LEVEL LIFE SAFETY PLANS 4
GI111-3001 LIFE SAFETY PLAN 5
EXISTING CONDITIONS SURVEY
VF-100 EXISTING CONDITIONS SURVEY 6
DEMOLITION PLAN
D-101 DEMOLITION & SEDIMENT EROSION CONTROL PLAN 7
SITE PLAN
CS-100 SITE & PHASING PLAN 8
CS-101 GRADING PLAN 9
CS-102 UTILITY PLAN 10
CS-501 SITE DETAILS 11
LANDSCAPING
L-101 PERIMETER FENCE PIERS TUCKPOINTING 12
L-102 SERVICE SEALS 13
STRUCTURAL
S-001 GENERAL NOTES 14
S-002 TESTING AND INSPECTION TABLES 15
SB100-1001 ADMINISTRATION FOUNDATION PLAN 16
SB100-3001 MAINTENANCE FOUNDATION PLAN 17
SF100-1001 ADMINISTRATION FIRST FLOOR FRAMING PLAN 18
SF100-3001 MAINTENANCE ROOF FRAMING PLAN 19
SF101-1001 ADMINISTRATION ROOF FRAMING PLAN 20
S-300 FOUNDATION DETAILS 21
S-500 FRAMING DETAILS 22
S-501 FRAMING DETAILS 23
ARCHITECTURE: ADMINISTRATION BUILDING: ARCHITECTURE
AD111-1001 BASEMENT & FIRST FLOOR LEVEL DEMOLITION PLAN 24
AC111-1001 BASEMENT & FIRST LEVEL REFLECTED CEILING PLAN 25
AE111-1001 FIRST & BASEMENT LEVEL FLOOR PLANS 26
AE112-1001 ROOF PLAN 27
AE201-1001 EXTERIOR ELEVATIONS 28
AE211-1001 INTERIOR ELEVATIONS 29
AE301-1001 WALL & BUILDING SECTIONS 30
AE320-1001 STAIR SECTIONS AND ENLARGED PLANS 31
AE501-1001 DETAILS 32
ARCHITECTURE: ADMINISTRATION BUILDING: INTERIORS
AE550-1001 INTERIOR DETAILS AND TYPICAL MOUNTING HEIGHTS 33
AE602-1001 DOOR SCHEDULE AND ELEVATIONS 34
AF101-1001 FIRST LEVEL FINISH PLAN 35
AF600-1001 MATERIAL AND ROOM FINISH SCHEDULE AND INTERIOR DETAILS 36
AW601-1001 WAYFINDING MESSAGE SCHEDULES AND SIGNAGE DETAILS 37
IF110-1001 FIRST LEVEL FURNITURE PLAN 38
ARCHITECTURE: MAINTENANCE BUILDING: ARCHITECTURE
AD111-3001 DEMOLITION PLANS AND ELEVATIONS 39
AE111-3001 FLOOR PLAN 40
AE112-3001 ROOF PLAN AND REFLECTED CEILING PLANS 41
AE201-3001 EXTERIOR ELEVATIONS 42
AE211-3001 INTERIOR ELEVATIONS 43
AE301-3001 BUILDING SECTIONS 44
AE311-3001 WALL SECTIONS 45
AE501-3001 DETAILS 46
AE550-3001 INTERIOR DETAILS AND TYPICAL MOUNTING HEIGHTS 47
AE601-3001 PARTITION TYPES AND OPENING SCHEDULE AND DETAILS 48
ARCHITECTURE: MAINTENANCE BUILDING: INTERIORS
AF101-3001 FIRST LEVEL FINISH PLAN 49
AF600-3001 MATERIAL AND ROOM FINISH SCHEDULE 50
AW601-3001 WAYFINDING MESSAGE SCHEDULES & SIGNAGE DETAILS 51
IF110-3001 FIRST LEVEL FURNITURE PLAN 52
TEMPORARY
ATT.01 ADMINISTRATION TEMPORARY TRAILER 53
ATT.02 MAINTENANCE TEMPORARY TRAILER 54
MECHANICAL
M000 MECHANICAL COVERSHEET 55
M101 FIRST FLOOR DEMOLITION -MECHANICAL- ADMINISTRATION &
MAINTENANCE 56
M201 FIRST FLOOR - MECHANICAL - ADMINISTRATION & MAINTENANCE 57
M400 MECHANICAL DETAILS 58
M600 MECHANICAL SCHEDULES 59
PLUMBING
P000 PLUMBING COVERSHEET 60
P101 FIRST FLOOR DEMOLITION -PLUMBING- ADMINISTRATION &
MAINTENANCE 61
P201 FIRST FLOOR - PLUMBING - ADMINISTRATION & MAINTENANCE 62
P400 PLUMBING DETAILS 63
ELECTRICAL
E000 ELECTRICAL COVERSHEET 64
E100 SITE PLAN - ELECTRICAL - DEMOLITION 65
E101 SITE PLAN - ELECTRICAL 66
E200 FIRST FLOOR - DEMOLITION - ADMINISTRATION & MAINTENANCE 67
E300 FIRST FLOOR - LIGHTING - ADMINISTRATION & MAINTENANCE 68
E400 FIRST FLOOR - POWER - ADMINISTRATION & MAINTENANCE 69
E401 BLACK HILLS AUXILLARY BUILDINGS - POWER 70
E500 ELECTRICAL DETAILS 71
E600 ELECTRICAL SCHEDULES 72
TECHNOLOGY
T000 TECHNOLOGY COVERSHEET 73
T100 TECHNOLOGY SITE PLAN 74
T101 BASEMENT FLOOR ADMIN. – DEMO AND NEW 75
T102 FIRST FLOOR ADMIN. – DEMO AND NEW 76
T103 FIRST FLOOR MAINTENANCE – DEMO AND NEW 77
T104 PUMP HOUSE VEHICLE STORAGE & SECONDARY MAINTENANCE
BUILDINGS NEW 78
T400 TECHNOLGY DETAILS 79
T500 TECHNOLOGY DIAGRAMS 80
T501 TECHNOLOGY DIAGRAMS 81
T502 TECHNOLOGY SCHEDULES 82
T600 TECHNOLOGY SCHEDULES 83
T601 TECHNOLOGY SCHEDULES 84
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text Utilities Underground Location Center
AutoCAD SHX Text
CALL 48 HOURS BEFORE DIGGING
AutoCAD SHX Text
DIAL 811
AutoCAD SHX Text Know what's
AutoCAD SHX Text below
AutoCAD SHX Text
AutoCAD SHX Text Call
AutoCAD SHX Text before you dig.
AutoCAD SHX Text
9172 ROGER A. ANDERSON
sbetker Text Box sbetker Text Box
DIAGRAMS
EX. G
ARAGE
FFE = 3624.7
EX. G
ARAGE
FFE = 3626.2
EX. G
ARAGE
FFE = 3626.0
EX. A
DMIN BUILDING
FFE = 3634.0
BLDG ADDITION
FFE = 3626.0
RAPID CITY, PIERRE &
EASTERN RAILROAD
PROPERTY LINE
BLDG ADDITION
FFE = 3634.0
CO
CO
BLDG 1001
BLDG 3001
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 v a nc a re no va te a dm in b ld gs b la ck h ill s nc c iv il\
_0 ca d fil es s he et s\
9_ te m pt ra ile rlo ca tio ns
.d w jd ob ia d:
/3
1/
1:
A lo t:1 0/
/2
1:
P M
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15785
BLACK HILLS NATIONAL CEMETERY 884-CM-3015
10-31-22
STURGIS, SOUTH DAKOTA
BID DOCUMENTS
SUBMITTAL
Date:
RENOVATE AND EXPAND
ADMINISTRATION AND
MAINTENANCE BUILDINGS
GEOTECHNICAL
AET
1745 SAMCO RD
RAPID CITY, SD 57702
(605) 223-4397
COST ESTIMATING
CPMI
3265 NORTHWOOD CIR STE 170
EAGAN, MN 55121
(952) 854-3663
MECHANICAL, ELECTRICAL,
TECHNOLOGY & STRUCTURAL
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
(309) 786-5075
OF 84
Office of Design and Construction
(TYP)
N
0 20' 40'
TEMPORARY TRAILER LOCATIONS
GI-002
---- 2
MAINTENANCE
TEMPORARY
TRAILER
LOCATION
ADMIN
TEMPORARY
TRAILER
LOCATION
GENERAL NOTES
1. SEE ARCHITECTURE FOR TEMPORARY TRAILER
DETAILS/INFORMATION.
2. CONTRACTOR CAN PERFORM WORK ON BOTH BUILDINGS
SIMULTANEOUSLY.
3. CONTRACTOR TO HAVE TEMPORARY TRAILERS INSTALLED &
APPROVED FOR USE PRIOR TO MOVING STAFF.
4. CONTRACTOR TO NOTIFY P.M. 14 DAYS PRIOR TO STAFF
RELOCATION.
5. TIME LINE FOR TEMPORARY TRAILERS ESTIMATED AT 14 MONTHS
FOR ADMIN AND 10 MONTHS FOR MAINTENANCE BUILDING
WORK.
6. TRAILER LOCATION TO BE VERIFIED IN FIELD W/ P.M.
7. CONTRACTOR MAY POTENTIALLY USE EXISTING WATER SERVICE
AT BUILDINGS FOR TEMPORARY TRAILERS IN LIEU OF
CONNECTION TO UNDERGROUND WATER SERVICE. VERIFY
CONNECTION LOCATIONS DURING WALK THROUGH. PROTECT
ANY CONNECTIONS FROM DAMAGE & WEATHER.
8. AREA PROVIDED IN THE NORTHWEST PORTION OF THE
CEMETERY FOR CONTRACTOR STAGING AND JOB TRAILER.
VERIFY JOB TRAILER LOCATION W/ P.M.
9. REPAIR IN-KIND ANY DISTURBED AREAS DUE TO TEMPORARY
FEED LINES OR TEMPORARY UTILITY SERVICES.
KEYNOTES
TEMPORARY WATER LINES FOR TRAILERS.
AVOID UTILITY CONFLICT.
TEMPORARY COMMUNICATION LINES FOR TRAILERS.
AutoCAD SHX Text 83.2
AutoCAD SHX Text 25.3
AutoCAD SHX Text 83.2
AutoCAD SHX Text 25.3
AutoCAD SHX Text 44.4
AutoCAD SHX Text 32.2
AutoCAD SHX Text 6.2
AutoCAD SHX Text 59.9
AutoCAD SHX Text 26.1
AutoCAD SHX Text 104.2
AutoCAD SHX Text 105.5
AutoCAD SHX Text 105.7
AutoCAD SHX Text 26.4
AutoCAD SHX Text 26.5
AutoCAD SHX Text 21.2
AutoCAD SHX Text 20.2
AutoCAD SHX Text 4.4
AutoCAD SHX Text 46.2
AutoCAD SHX Text 30.1
AutoCAD SHX Text 13.7
AutoCAD SHX Text 8.0
AutoCAD SHX Text 18.9
AutoCAD SHX Text 8.0
AutoCAD SHX Text 13.6
AutoCAD SHX Text 4.5
AutoCAD SHX Text 7.5
AutoCAD SHX Text 5.3
AutoCAD SHX Text 6.3
AutoCAD SHX Text 6.4
AutoCAD SHX Text 5.3
AutoCAD SHX Text 9.2
AutoCAD SHX Text 7.3
AutoCAD SHX Text D R A I N F I E L D S
AutoCAD SHX Text
ABANDONED DRAIN FIELD
AutoCAD SHX Text S E C T I O N A
AutoCAD SHX Text S E C T I O N B
AutoCAD SHX Text S E C T I O N E
AutoCAD SHX Text
SECTION MB
AutoCAD SHX Text Utilities Underground Location Center
AutoCAD SHX Text
CALL 48 HOURS BEFORE DIGGING
AutoCAD SHX Text
DIAL 811
AutoCAD SHX Text Know what's
AutoCAD SHX Text below
AutoCAD SHX Text
AutoCAD SHX Text Call
AutoCAD SHX Text before you dig.
AutoCAD SHX Text
9172 ROGER A. ANDERSON
sbetker
ARCHITECTURAL ABBREVIATIONS
A/C
A/C UNIT
A/E
AAMA
AAP
AB
ABC
ACC
ACI
ACT
ACS DR
ACS FLR
ACS PNL
ACST
AD
ADA
ADC
ADDL
ADDN
ADH
ADJ
ADMIN
AFF
AFG
AFS
AGC
AGGR
AHJ
AHR
AHU
AIA
AISC
ALT
ALT NO
ALUM
AMT
ANOD
ANSI
ANT
AP
APA
APC
APPD
APPROX
AR
ARCH
ASB
ASI
ASKLR
ASPH
ASSN
ASTM
ATCH
ATM
AUTO
AUX
AV
AVG
AW
AWI
AWPA
AWS
B PL
BAT
BD
BD FT
BEV
BHMA
BI FLD DR
BITUM
BKG
BLD
BLDG
BM
BOT
BRCG
BRDG
BRDG JST
BRG
BRG PL
BRKT
BRZ
BSMT
BTWN
BUR
C CONC
C TO C
CAB
CAC
CB
CBB
CCD
CCTV
CCW
CD
CEM
CEM PLAS
CER
CF
CF/CI
CF/OI
CFLG
CFMF
CG
CGSFU
CH
CHEM
CHFR
CHK
CI
CIP
CIR
CIRC
CJ
CL
CLDG
CLG
CLR
CM
CMU
AIR CONDITION
AIR CONDITIONING UNIT
ARCHITECT/ENGINEER
AMERICAN ARCHITECTURAL MANUFACTURERS ASSN
ALARM ANNUNCIATOR PANEL
ANCHOR BOLT
AGGREGATE BASE COURSE
ACCESSIBLE
AMERICAN CONCRETE INSTITUTE
ACOUSTICAL CEILING TILE
ACCESS DOOR
ACCESS FLOOR
ACCESS PANEL
ACOUSTIC
AREA DRAIN
AMERICANS WITH DISABILITIES ACT
AUTOMATIC DOOR CLOSER
ADDITIONAL
ADDITION
ADHESIVE
ADJACENT, ADJOINING, OR ADJUSTABLE
ADMINISTRATION
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ABOVE FINISHED SLAB
ASSOCIATED GENERAL CONTRACTORS
AGGREGATE
AUTHORITY HAVING JURISDICTION
ANCHOR
AIR HANDLING UNIT
AMERICAN INSTITUTE OF ARCHITECTS
AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALTERNATE
ALTERNATE NUMBER
ALUMINUM
AMOUNT
ANODIZE
AMERICAN NATIONAL STANDARDS INSTITUTE
ANTENNA
ACCESS PANEL
AMERICAN PLYWOOD ASSOCIATION
ARCHITECTURAL PRECAST CONCRETE
APPROVED
APPROXIMATE
AS REQUIRED
ARCHITECT
ASBESTOS
ARCHITECT'S SUPPLEMENTAL INSTRUCTION
AUTOMATIC SPRINKLER
ASPHALT
ASSOCIATION
AMERICAN SOCIETY FOR TESTING AND MATERIALS
ATTACHMENT
AUTOMATIC TELLER MACHINE
AUTOMATIC
AUXILIARY
AUDIO VISUAL
AVERAGE
ACID WASTE
ARCHITECTURAL WOODWORKING INSTITUTE
AMERICAN WOOD PRESERVERS' ASSOCIATION
AMERICAN WELDING SOCIETY
BASE PLATE
BATTEN
BOARD
BOARD FEET (FOOT)
BEVEL
BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION
BIFOLDING DOORS
BITUMINOUS
BACKING
BUILD
BUILDING
BEAM OR BENCHMARK
BOTTOM
BRACING
BRIDGING
BRIDGING JOIST
BEARING
BEARING PLATE
BRACKET
BRONZE
BASEMENT
BETWEEN
BUILT-UP ROOFING
CAST CONCRETE
CENTER TO CENTER
CABINET
CEILING ATTENUATION CLASS
CATCH BASIN OR CORNER BEAD
CEMENTITIOUS (BACKER) BOARD
CONSTRUCTION CHANGE DIRECTIVE
CLOSED CIRCUIT TELEVISION
COUNTERCLOCKWISE
CONSTRUCTION DOCUMENTS OR CONTRACT DOCUMENTS
CEMENT
CEMENT PLASTER
CERAMIC
CONTRACTOR FURNISHED
CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CONTRACTOR FURNISHED/OWNER INSTALLED
COUNTERFLASHING
COLD-FORMED METAL FRAMING
CORNER GUARD
CERAMIC GLAZED STRUCTURAL FACING UNITS
COAT HOOK
CHEMICAL
CHAMFER
CHECK
CAST IRON
CAST-IN-PLACE
CIRCLE
CIRCULAR
CONSTRUCTION JOINT OR CONTROL JOINT
CENTER LINE
CLADDING
CEILING
CLEAR
CONSTRUCTION MANAGEMENT
CONCRETE MASONRY UNIT
CNR
CNTR
CRTP
CO
CO2
COL
COM
COMB
COMM
COMP
CONC
CONC FLR
COND
CONF
CONN
CONSTR
CONT
CONTR
COORD
CORR
CPM
CPRS
CR
CRS
CRSI
CSB
CSG
CSI
CSK
CSMT
CSWK
CTG
CTR
CTRL
CTV
CU FT
CU IN
CU YD
CURT
CYL
CYL L
D
DAT
DBL
DBL GLZ
DCS
DP
DEG
DEL
DEMO
DEPT
DET
DF
DIA
DIAG
DIFF
DIM
DIR
DISP
DIST
DIV
DL
DOC
DR
DR CL
DR FR
DR OPNG
DS
DSGN
DW
DWG
E
EA
EFF
EFS
EIFS
EJ
EL
ELAST
ELEC
ELEC DR OP
ELEV
EMER
EMER SHR
ENCL
ENGR
ENVIR
EO
EPA
EPDM
EPO
EPS
EQ
EQL SP
EQUIP
EQUIV
ERD
ESC
ESMT
ESP
EST
ETC
EW
EWC
EWS
EXH
EXIST
EXP
EXP BT
EXST GR
EXT
EXT GR
CORNER
COUNTER
COUNTERTOP
CARBON MONOXIDE
CARBON DIOXIDE
COLUMN
COMMON
COMBINATION, COMBINED
COMMUNICATION
COMPONENT
CONCRETE
CONCRETE FLOOR
CONDENSER OR CONDITION
CONFERENCE
CONNECT
CONSTRUCTION
CONTINUE
CONTRACTOR
COORDINATE
CORRIDOR
CRITICAL PATH METHOD
COMPRESSIBLE
CARD READER
COLD ROLLED STEEL
CONCRETE REINFORCING STEEL INSTITUTE
CONCRETE SPLASH BLOCK
CASING
CONSTRUCTION SPECIFICATIONS INSTITUTE
COUNTER SUNK
CASEMENT
CASEWORK
COATING
CENTER
CONTROL
CABLE TELEVISION
CUBIC FEET
CUBIC INCH
CUBIC YARD
CURTAIN
CYLINDER
CYLINDER LOCK
DEPTH OR PENNY (NAIL)
DATUM
DOUBLE
DOUBLE GLAZE
DIAPER CHANGING STATION
DECORATIVE PANEL
DEGREE
DELETE
DEMOLITION
DEPARTMENT
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIAGONAL
DIFFERENCE OR DIFFUSER
DIMENSION
DIRECTION
DISPENSER
DISTANCE
DIVIDE OR DIVISION
DEAD LOAD
DOCUMENT
DOOR, DRAIN, DRESSING ROOM, OR DRIVE
DOOR CLOSER
DOOR FRAME
DOOR OPENING
DOWNSPOUT
DESIGN
DISHWASHER
DRAWING
EAST
EACH
EFFICIENCY
EXTERIOR FINISH SYSTEM
EXTERIOR INSULATION AND FINISH SYSTEM
EXPANSION JOINT
ELEVATION
ELASTOMERIC
ELECTRIC
ELECTRIC DOOR OPENER
ELEVATOR
EMERGENCY
EMERGENCY SHOWER
ENCLOSURE
ENGINEER
ENVIRONMENT
ELECTRICAL OUTLET
ENVIRONMENTAL PROTECTION AGENCY
ETHYLENE PROPYLENE DIENE MONOMER
EMERGENCY POWER OFF
EXPANDED POLYSTYRENE BOARD (INSULATION)
EQUAL
EQUALLY SPACED
EQUIPMENT
EQUIVALENT
EXISTING ROOF DRAIN
ESCAPE OR ESCUTCHEON
EASEMENT
ESPECIALLY
ESTIMATE
AND SO FORTH OR ET CETERA
EACH WAY
ELECTRIC WATER COOLER
EYE WASH STATION
EXHAUST
EXISTING
EXPANSION OR EXPOSED
EXPANSION BOLT
EXISTING GRADE
EXTERIOR, EXTERNAL, OR EXTINGUISHER
EXTERIOR GRADE
F
FA
FAB
FAC
FACIL
FAS
FAS BD
FCU
FCO
FCTY
FD
FDC
FDTN
FE
FEC
FF
FF EL
FF&E
FHC
FHP
FIG
FIL
FIN
FIN FLR
FIN GR
FIN WD
FIXT
FL
FLASH
FLDG
FLEX
FLG
FLR
FLR FIN
FLR SK
FLUOR
FLUOR FIX
FM
FM-G
FO
FOC
FOF
FOM
FOS
FOUNT
FOW
FP
FR
FR SNK
FREQ
FRMG
FRP
FRZ
FS
FSB
FSTNR
FT
FTG
FURG
FURN
FUT
FVC
GA
GAL
GALV
GALV STL
GB
GC
GD
GDR
GEN
GFRC
GFRG
GFRP
GI
GL
GL BLK
GLU LAM
GP
GR FL
GRAN
GRTG
GSB
GSM
GSU
GT
GUAR
GUT
GYP
GYP BD
GYP PLAS
H
HAZ MAT
HB
HC
HCWD
HDBD
HDO
HDR
HDW
HDWD
HEPA
HEX
HGR
HM
HMD
HMDF
HMF
HNDRL
HO
HORIZ
HOSP
HP
HPD
HPDL
HQ
HS
HSE
HSKPG
FAHRENHEIT OR FEMALE
FIRE ALARM
FABRIC
FACTOR
FACILITY
FASCIA
FASCIA BOARD
FAN COIL UNIT
FLOOR CLEANOUT
FACTORY
FLOOR DRAIN
FIRE DEPARTMENT CONNECTION
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISH FACE
FINISH FLOOR ELEVATION
FURNITURE, FIXTURE, AND EQUIPMENT
FIRE HOSE CABINET
FULL HEIGHT PARTITION
FIGURE
FILLET
FINISH
FINISH FLOOR
FINISH GRADE
FINISH WOOD
FIXTURE
FLOORLINE
FLASHING
FOLDING
FLEXIBLE
FLOORING
FLOOR
FLOOR FINISH
FLOOR SINK
FLUORESCENT
FLUORESCENT FIXTURE
FACTORY MUTUAL
FACTORY MUTUAL GLOBAL
FINISHED OPENING
FACE OF CONCRETE OR FACE OF CURB
FACE OF FINISH
FACE OF MASONRY
FACE OF SLAB OR FACE OF STUD
FOUNTAIN
FACE OF WALL
FIRE PROTECTION OR FIREPROOF
FIRE RATING, FIRE RESISTANT, OR FRAME
FLUSHING RIM SINK
FREQUENCY
FRAMING
FIBERGLASS REINFORCED PLASTIC
FREEZER
FEDERAL SPECIFICATION
FOLDING SHOWER BENCH
FASTENER
FEET OR FOOT
FOOTING
FURRING
FURNISH OR FURNITURE
FUTURE
FIRE VALVE CABINET
GAGE OR GYPSUM ASSOCIATION
GALLON
GALVANIC OR GALVANIZED
GALVANIZED STEEL
GRAB BAR
GENERAL CONTRACTOR
GUARD
GUARD RAIL
GENERAL OR GENERATOR
GLASS-FIBER-REINFORCED CONCRETE
GLASS-FIBER-REINFORCED GYPSUM
GLASS-FIBER-REINFORCED PLASTIC
GALVANIZED IRON
GLASS
GLASS BLOCK
GLUED LAMINATED WOOD
GRAB BAR
GROUND FLOOR
GRANITE
GRATING
GYPSUM SHEATHING BOARD
GALVANIZED SHEET METAL
GLAZED STRUCTURAL UNIT
GROUT
GUARANTEE
GUTTER
GYPSUM
GYPSUM BOARD
GYPSUM PLASTER
HIGH OR HUMIDISTAT
HAZARDOUS MATERIALS
HOSE BIBB
HOLLOW CORE
HOLLOW CORE WOOD DOOR
HARDBOARD
HIGH DENSITY OVERLAY
HEADER
HARDWARE
HARDWOOD
HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HEXAGON
HANGER
HOLLOW METAL
HOLLOW METAL DOOR
HOLLOW METAL DOOR AND FRAME
HOLLOW METAL FRAME
HANDRAIL
HOLD OPEN
HORIZONTAL
HOSPITAL
HIGH PRESSURE
HYGIENE PRODUCT DISPOSAL
HIGH PRESSURE DECORATIVE LAMINATE
HEADQUARTERS
HEAT-STRENGTHENED (GLASS) OR HIGH STRENGTH
HOUSE
HOUSEKEEPING
HST
HSS
HT
HVAC
HVY
HW
HYD
HYDR
IAQ
IBC
IC
ICW
ID
ID NO
ILLUM
INCL
IND
INFO
INSUL
INT
INTL
IWH
JAN
KD
KIT
KO
KPL
LAB
LAD
LAM
LAM GL
LAU
LAV
LBR
LBS
LCS
LD BRG
LDR
LED
LF
LIB
LIN
LIQ
LKR
LKR RM
LL
LMST
LRG
LRV
LS
LT
LT GA
LT WT
LTG
LTNG
LVD
LVR
LWC
LWIC
LYR
MACH
MACH RM
MAINT
MAN
MATL
MATV
MAX
MBD
MCB
MD
ME
MEAS
MECH
MECH RM
MED
MEK
MEMB
MEMO
MEZZ
MF
MFD
MFG
MFR
MFR REC
MGT
MIC
MID
MIL STD
MIN
MIR
MISC
MIT
MKR
ML
MLDG
MLWK
mm
MO
MOD
MOD BIT
MON
MOPR
MR
MS
MTD
MTG
MTL
MULL
MW
MWP
HOIST
HOLLOW STRUCTURAL STEEL
HEIGHT
HEATING, VENTILATING, AND AIR CONDITIONING
HEAVY
HOT WATER
HYDRANT
HYDRAULIC
INDOOR AIR QUALITY
INTERNATIONAL BUILDING CODE
INFECTION CONTROL
INFECTION CONTROL WALL
INSIDE DIAMETER
IDENTIFICATION NUMBER
ILLUMINATION
INCLUDED
INDEPENDENT OR INDUSTRIAL
INFORMATION
INSULATION
INTERIOR
INTERNATIONAL
INSTANTANEOUS WATER HEATER
JANITOR
KILN DRIED OR KNOCKED DOWN
KITCHEN
KNOCKOUT
KICKPLATE
ANGLE
LABORATORY
LADDER
LAMINATE
LAMINATED GLASS
LAUNDRY
LAVATORY
LUMBER
POUND
LOCKABLE CHARTING STATION/MED CABINET
LOAD-BEARING
LEADER
LIGHT EMITTING DIODE
LINEAR FEET (FOOT)
LIBRARY
LINEAR
LIQUID
LOCKER
LOCKER ROOM
LEAD LINED
LIMESTONE
LARGE
LOUVERED ROOF VENT
LIGHT SWITCH
LIGHT
LIGHT GAGE
LIGHTWEIGHT
LIGHTING
LIGHTNING
LOUVERED
LOUVER
LIGHTWEIGHT CONCRETE
LIGHTWEIGHT INSULATING CONCRETE
LAYER
MACHINE
MACHINE ROOM
MAINTENANCE
MANUAL
MATERIAL
MASTER ANTENNA TELEVISION SYSTEM
MAXIMUM
MARKER BOARD
METAL CORNER BEAD
DECK
MECHANICAL ENGINEER
MEASURE
MECHANICAL
MECHANICAL ROOM
MEDICAL, MEDIUM
METHYL ETHYL KETONE
MEMBRANE
MEMORANDUM
MEZZANINE
MILL FINISH
MANUFACTURED
MANUFACTURING
MANUFACTURER
MANUFACTURER'S RECOMMENDATION
MANAGEMENT
MICROPHONE
MIDDLE
MILITARY STANDARD
MINIMUM
MIRROR
MISCELLANEOUS
MITER
MARKER
METAL LATH
MOLDING (MOULDING)
MILLWORK
MILLIMETER
MASONRY OPENING
MODEL, MODIFY OR MODULE
MODIFIED BITUMEN
MONITOR
MOP RACK
MOISTURE RESISTANT
MOP SINK
MOUNTED
MOUNTING
METAL
MULLION
MICROWAVE
MEMBRANE WATERPROOFING
N
NA
NAT
NATL
NC
NCOMBL
NEC
NEG
NEMA
NEUT
NFC
NFPA
NIC
NO
NOM
NR
NRC
NRCA
NRP
NS
NUM
O/O O
OA
OC
OCC
OCT
OD
OD
OF/CI
OFD
OFF
OF/OI
OH
OH DR
OPH
OPNG
OPP
OPR
OPT
OR
ORD
ORG
ORIG
ORN
OSHA
OUT
OZ
P
PAR
PARA
PART
PAT
PB
PBD
PC
PCA
PCC
PCCP
PCD
PCF
PCP
PCT
PED
PEN
PEND
PERF
PERIM
PERP
PHAR
PHOTO
PKG
PL
PL GL
PLAM
PLAS
PLBG
PLYWD
PMTL
PNEU
PNL
PO
POLY
PP
PR
PRCST
PREFAB
PREFIN
PRELIM
PREP
PRESS
PREV
PRKG
PRMLD
PROJ
PROP
PSF
PSI
PT
PTD
PTN
PTS
PVC
PVG
PWR
QA
QC
QRY
QTR
QTY
QUAD
QUAL
R
RA
RAD
RBM
RBR
NORTH
NOT APPLICABLE
NATURAL
NATIONAL
NOISE CRITERIA OR NURSE CALL
NONCOMBUSTIBLE
NATIONAL ELECTRICAL CODE
NEGATIVE
NATIONAL ELECTRICAL MANUFACTURERS ASSN
NEUTRAL
NATIONAL FIRE CODE
NATIONAL FIRE PROTECTION ASSOCIATION
NOT IN CONTRACT
NUMBER
NOMINAL
NOISE REDUCTION
NOISE REDUCTION COEFFICIENT
NATIONAL ROOFING CONTRACTORS ASSOCIATION
NONREMOVABLE
NARROW STILE
NUMERAL
OUT TO OUT
OXYGEN
OUTSIDE AIR OR OVERALL
ON CENTER
OCCUPY
OCTAGON
OUTSIDE DIAMETER, OUTSIDE DIMENSION
OUTSIDE DIAMETER/OUTSIDE DIMENSION
OWNER FURNISHED/CONTRACTOR INSTALLED
OVERFLOW DRAIN
OFFICE
OWNER FURNISHED/OWNER INSTALLED
OVERHANG
OVERHEAD (COILING) DOOR
OPPOSITE HAND
OPENING
OPPOSITE
OPERABLE
OPTIONAL
OPERATING ROOM OR OUTSIDE RADIUS
ORDNANCE OR OVERFLOW ROOF DRAIN
ORGANIC
ORIGINAL
ORNAMENTAL
OCCUPATIONAL SAFETY AND HEALTH ADMINSTRATION
OUTLET
OUNCE
PAINT
PARALLEL OR PARAPET
PARAGRAPH
PARTIAL
PATTERN
PUSHBUTTON
PARTICLEBOARD
PIECE, POLYCARBONATE OR PORTLAND CEMENT
PORTLAND CEMENT ASSOCIATION
PRECAST CONCRETE
CONCRETE PAVEMENT
PAPER CUP DISPENSER
POUNDS PER CUBIC FOOT
PORTLAND CEMENT PLASTER
PRIVACY CURTAIN TRACK
PEDESTAL
PENETRATE
PENDANT
PERFORATED
PERIMETER
PERPENDICULAR
PHARMACY
PHOTOGRAPH
PACKAGE
PROPERTY LINE
PLATE GLASS
PLASTIC LAMINATE
PLASTER OR PLASTIC
PLUMBING
PLYWOOD
PAINTED METAL
PNEUMATIC
PANEL
POST OFFICE, PURCHASE ORDER
POLYETHYLENE (PLASTIC)
PUSH PLATE
PAIR
PRECAST
PREFABRICATE
PREFINISH
PRELIMINARY
PREPARATION
PRESSURE
PREVIOUS
PARKING
PREMOLDED
PROJECT
PROPERTY
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PORCELAIN TILE OR PRESSURE TREATED
PAPER TOWEL DISPENSER
PARTITION
PNEUMATIC TUBE STATION
POLYVINYL CHLORIDE (PLASTIC)
PAVING
POWER
QUALITY ASSURANCE
QUALITY CONTROL
QUARRY
QUARTER
QUANTITY
QUADRANT
QUALITY
RADIUS OR RISER
RETURN AIR
RADIATOR
REINFORCED BRICK MASONRY
RUBBER
RC
RCP
RCVR
RD
REC
RECD
RECPT
RECT
REF
REFR
REG
REINF
REP
REPL
REQ
REQD
RET
REV
RFG
RFI
RFP
RFS
RL
RLG
RM
RM LT
RND
RO
ROW
RS
RSV
RT
RV
RVS
RWL
S
SA
SALV
SAMP
SAN
SB
SBS
SBSTR
SC
SCH
SCHED
SCHEM
SCP
SCRN
SCT
SCWD
SD
SDG
SECT
SEG
SEL
SEP
SF
SFTWD
SGD
SGL
SHR
SHR HD
SHRD
SHT
SHTHG
SHV
SIM
SJ
SJI
SK
SKLT
SLDG
SLNT
SM
SMK
SND INS
SPEC
SPKLR
SPKR
SPLY
SPR
SQ
SQ IN
SQ YD
SST
ST
STC
STD
STIF
STL JST
STL LNTL
STL PL
STL RF DK
STL TB
STL TR
STNLS
STOR
STR
STRUCT
STRUCT STL
SUB
SURF
SUSP
SUSP CLG
SW
SWDR
SYM
SYNTH
SYS
REMOTE CONTROL
REFLECTED CEILING PLAN
RECEIVER
ROAD OR ROOF DRAIN
RECESSED
RECEIVED
RECEPTACLE
RECTANGLE
REFERENCE OR REFRIGERATOR
REFRACTORY, REFRIGERATION
REGISTER
REINFORCE
REPAIR
REPLACE
REQUIRE
REQUIRED
RETURN
REVISION
ROOFING
REQUEST FOR INFORMATION
REQUEST FOR PROPOSAL
ROOM FINISH SCHEDULE
ROOF LEADER
RAILING
ROOM
NURSE CALL LIGHT/ROOM LIGHT
ROUND
ROUGH OPENING
RIGHT OF WAY
ROUGH SAWN
RESILIENT SHEET VINYL
RIGHT
ROOF VENT
REVERSE
RAIN WATER LEADER
SOLID SURFACE
SUPPLY AIR
SALVAGE
SAMPLE
SANITARY
SPLASH BLOCK
STYRENE BUTADIEN STYRENE
SUBSTRATE
SHARPS CONTAINER
SCHOOL
SCHEDULE
SCHEMATIC
SCUPPER
SCREEN
SHOWER CURTAIN TRACK
SOLID CORE WOOD DOOR
SMOKE DETECTOR/SOAP DISPENSER
SIDING
SECTION
SEGMENT
SELECT
SEPARATE
SQUARE FOOT (FEET)
SOFTWOOD
SLIDING GLASS DOOR
SINGLE
SHOWER
SHOWER HEAD
SHOWER DRAIN
SHEET
SHEATHING
SHELVING
SIMILAR
SCORED JOINT
STEEL JOIST INSTITUTE
SKETCH
SKYLIGHT
SLIDING
SEALANT
SHEET METAL
SMOKE
SOUND INSULATION
SPECIFICATION
SPRINKLER
SPEAKER
SUPPLY
SINGLE PLY ROOF SYSTEM
SQUARE
SQUARE INCH
SQUARE YARD
STAINLESS STEEL
STAIRS OR STREET
SOUND TRANSMISSION CLASS
STANDARD
STIFFENER
STEEL JOIST
STEEL LINTEL
STEEL PLATE
STEEL ROOF DECK
STEEL TUBE
STEEL TRUSS
STAINLESS
STORAGE
STRINGERS
STRUCTURAL
STRUCTURAL STEEL
SUBSTITUTE
SURFACE
SUSPEND
SUSPENDED CEILING
SWITCH
SWING DOOR
SYMBOL
SYNTHETIC
SYSTEM
T T&M
TB
TBD
TECH
TEL
TEMP
THERM
THK
THRES
THRU
THRUOUT
TMPD
TMPD GL
TN
TO
TO FDN
TOB
TOM
TOP
TOS
TOW
TPD
TRANS
TRTD
TS
TSTAT
TV
TYP
U
UC
UGND
UL
ULT
UNFIN
UNO
UPS
UR
UTIL
UV
VAC
VAR
VEH
VENT
VERT
VEST
VFD
VIC
VID
VIF
VNR
VOC
VOL
VR
VTR
W/ W/O
WBL
WC
WD
WDW
WF
WFR
WFS
WH
WHSE
WP
WPM
WR
WS
WSCT
WT
X BRACE
XPS
YD
TREAD OR THERMOSTAT
TIME AND MATERIALS
TOWEL BAR
TACK BOARD
TECHNICAL
TELEPHONE
TEMPERATURE OR TEMPORARY
THERMAL
THICKNESS
THRESHOLD
THROUGH
THROUGHOUT
TEMPERED
TEMPERED GLASS
TRUE NORTH
TOP OF ___
TOP OF FOUNDATION
TOP OF BEAM
TOP OF MASONRY
TOP OF PARAPET
TOP OF STEEL
TOP OF WALL
TOILET PAPER DISPENSER
TRANSOM
TREATED
TUBE STEEL
THERMOSTAT
TELEVISION
TYPICAL
HEAT TRANSFER COEFFICIENT
UNDERCUT
UNDERGROUND
UNDERWRITERS LABORATORIES
ULTIMATE
UNFINISH
UNLESS NOTED OTHERWISE
UNINTERRUPTIBLE POWER SUPPLY
URINAL
UTILITY
ULTRAVIOLET
VACUUM
VARIES
VEHICLE
VENTILATION
VERTICAL
VESTIBULE
VARIABLE FREQUENCY DRIVE
VICINITY
VIDEO
VERIFY IN FIELD
VENEER
VOLATILE ORGANIC COMPOUND
VOLUME
VAPOR RETARDER
VENT THROUGH ROOF
WITH
WITHOUT
WOOD BLOCKING
WATER CLOSET
WOOD
WINDOW
WIDE FLANGE
WOOD FRAME
WOOD FURRING STRIPS
WATER HEATER
WAREHOUSE
WATERPROOFING
WATERPROOF MEMBRANE
WEATHER RESISTANT
WEATHERSTRIP OR WALL SCONCE
WAINSCOT
WEIGHT OR WINDOW TREATMENT
CROSS BRACE
EXTRUDED POLYSTYRENE BOARD
YARD
DATE:
License #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
SUBMITTAL
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
GEOTECHNICAL:
AET
1745 SAMCO RD
RAPID CITY, SD 57702
(605) 223-4397
COST ESTIMATING:
CPMI
3265 NORTHWOOD CIR STE 170
EAGAN, MN 55121
(952) 854-3663
MECHANICAL, ELECTRICAL,
TECHNOLOGY &
STRUCTURAL:
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
(309) 786-5075
BLACK HILLS NATIONAL CEMETERY
RENOVATE AND EXPAND
ADMINISTRATION AND
MAINTENANCE BUILDINGS
884-CM-3015
STURGIS, SOUTH DAKOTA
10/31/2022
C U s e rs \m m a rs h a le k \D o c u m e n ts \1
B
L A
C K
H
IL
L S
N C
A
A R
C H
R m m a rs h a le k .r v t
/1 /2
:4
:0
A
M
GI002-1001
ABBREVIATIONS
10/31/2022 MP MP16409Revisions: Date:
sbetker
NOYES
APPLICABLE REGULATIONS
GENERAL TYPE OF PROJECT
NFPA NATIONAL FIRE CODES (EXCEPTION: NFPA 5000 & 900)
2018 FGI GUIDELINES
2018 NFPA 101 (LIFE SAFETY CODE)
ABA STANDARDS (2015) (ABAAS)
2018 IBC
REMODEL
ADDITION
NEW BUILDING
PROJECT DESCRIPTION
CODE SUMMARY
CONSTRUCT APPROXIMATELY 678 GSF ADDITION TO EXISTING
2,882 GSF ADMINISTRATION BUILDING. TYPE V (000)
CONSTRUCTION. REMODEL 2,882 GSF IN EXISTING SPACE.
TOTAL BUILDING IS 3,560 GSF. UPGRADE FACILITY TO
ACCESSIBILITY STANDARDS.
VA BARRIER FREE DESIGN STANDARD (PG-18-13)
NOYESAUTHORITIES HAVING JURISDICTION (AHJ's)
THE JOINT COMMISSION (TJC)
CENTER FOR MEDICARE/MEDICAID SERVICES (CMS)
TESTRATING (HRS)
TOTAL
EXTERIOR DOORS AND WINDOWS
SHAFTS AND EXIT PASSAGEWAYS
OTHER
ROOF CONSTRUCTION
PRIME & SEC. FLOOR BEAMS, JOISTS
FLOOR/CEILING ASSEMBLY
FLOOR CONSTRUCTION
INTERIOR
NON-BEARING WALLS AND PARTITIONS
BEARING WALLS
COLUMNS
GIRDERS
TRUSSES
ROOF/CEILING ASSEMBLY
PRIME & SEC. ROOF BEAMS, JOISTS
EXTERIOR
INTERIOR BEARING WALLS
EXTERIOR BEARING WALLS
STRUCTURAL FRAME
AREA SEPARATIONS / FIRE WALLS
FIRE-RESISTIVE REQUIREMENTS
TYPE(S) OF CONSTRUCTION
ACTUAL AREA PER FLOOR
CONSTRUCTION TYPE(S)
BASEMENT FLOOR
FIRST FLOOR
NONE
PLUMBING FIXTURES
TOILETS
LAVATORIES
DRINKING FOUNTAINS
SERVICE SINKS
PROVIDED RQD FACTOR
3F, 2M 1 M, 1 F 1/25 for first 50 occupants, then 1/50
3F, 3M 1M, 1F 1/40 for first 80 occupants, then 1/80 1/100 occupants. 50% may be vending
URINALS 1M -- --
OCCUPANT LOAD OF BUILDING
SF/OCCUPANT OCCUPANTS
TOTAL BUILDING OCCUPANT LOAD:
ACTUAL AREAAREA LOCATION
FIRST LEVEL
BASEMENT LEVEL
678 GSF
1,160 GSF
3,560 GSF
2,400 GSF
1,160 GSF
150 24
ZERO NA
(IBC CH 29)
(NAPA 220 TABLE 4.1.1)
OSHA STANDARDS
VA SEISMIC DESIGN REQUIREMENTS H-18-8
NATIONAL ELECTRIC CODE (NEC)
ASME BOILER AND PRESSURE VESSEL CODE
ASME CODE FOR PRESSURE PIPING
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE,
AMERICAN CONCRETE INSTITUTE AND COMETARY (ACI 318)
MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE
FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL STEEL
BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
ENERGY POLICY ACT OF 2005 (EPAct)
DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS
FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE
RESIDENTIAL BUILDINGS AND NEW LOW-RISE RESIDENTIAL
BUILDINGS, 10 CFR PARTS 433,434 AND 435
FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE
BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
EXECUTIVE ORDER 13834
THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED
IN THE GENERAL REQUIREMENTS SECTION 01010 OF THE VA
MASTER CONSTRUCTION SPECIFICATION
VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE
STANDARD 62.1-2004
SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE
STANDARD 15 -2007
VA FIRE PROTECTION DESIGN MANUAL
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA
NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER
GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL)
AREAS OF REFUGE REQUIRED
MEANS OF EGRESS CAPACITY (width in inches)
EGRESS
32"
NOYES
ACCESSIBLE MEANS OF EGRESS ("MOE") REQUIRED
ELEVATOR REQUIRED AS MEANS OF EGRESS
(Input)
(Input)
ALLOWABLE HEIGHTACTUAL HEIGHT
(Table 503)
(Table 503) (Input)
STORIES
FEET
BUILDING HEIGHT
(Input)
(IBC Section 503)
( from table 503)
ALLOWABLE AREA PER FLOOR
BASIC ALLOWABLE AREA
NOYES
(Section 8.3)
CHANGE OF OCCUPANCY?
SEPARATED OCCUPANCIES?
FIRE BARRIER RATING(S) SEE LIFE SAFETY PLANS
OCCUPANCY CLASSIFICATION(S)
OCCUPANCIES
(If Remodeling)
2018 LSC (TABLE 6.1.14.1)
(LSC CH 12-42)
EXISTING BUSINESS OCCUPANCY
TYPE V (000)
9000 GSF
NEW ADDITION
EXISTING 1,722 GSF
ZERO
ZERO
ZERO
ZERO
ZERO
ZERO
ZERO
ZERO
ZERO
ZERO
ZERO
ZERO
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
LIFE SAFETY SYMBOLS
SMOKE TIGHT
ASSEMBLY
1 HOUR FIRE
BARRIER
1 HOUR FIRE &
SMOKE BARRIER
2 HOUR FIRE &
SMOKE BARRIER
HE
TRAVEL DISTANCE
100'-10"
TRAVEL DISTANCE
EA
ED
EXIT EXIT
HORIZONTAL EXIT EXIT DISCHARGE
EXIT ACCESSFIRE
EXTINGUISHER
FE
FIRE
EXTINGUISHER
CABINET
FECLIMITS OF
CONSTRUCTION
NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN
183 SF
MULTIPURPOSE/
BREAKROOM 271 SF
CONFERENCE
/ TRAINING
161 SF
CORRIDOR
464 SF
OPEN
OFFICE
19 SF
UNIFORM
STORAGE
16 SF
HAC
59 SF
UNISEX
TOILET
146 SF
ADMIN
OFFICE
182 SF
LOBBY
119 SF
VESTIBULE/
INFO
CENTER
147 SF
DIRECTORS
OFFICE
70 SF
ADMIN
74 SF
OPERATIONS
CENTER
154 SF
WOMEN'S
117 SF
MEN'S
FEC
FEC
E D
ED
EXIT
EXIT
E X
IT
UP
TRAVEL DISTANCE
81'-0"
344 SF
B08
STORAGE
45 SF
B04
STORAGE
73 SF
B05
HALL
32 SF
B06
ALCOVE
14 SF
B07
CLOSET
UNEXCUVATED
UNEXCUVATED
UP
370 SF
B01
OPEN AREA
CRAWLSPACE
101 SF
B02
DATA
128 SF
B03
ELEC
EXIT
TRAVEL DISTANCE
56'-0"
FEC
DATE:
License #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
SUBMITTAL
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
GEOTECHNICAL:
AET
1745 SAMCO RD
RAPID CITY, SD 57702
(605) 223-4397
COST ESTIMATING:
CPMI
3265 NORTHWOOD CIR STE 170
EAGAN, MN 55121
(952) 854-3663
MECHANICAL, ELECTRICAL,
TECHNOLOGY &
STRUCTURAL:
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
(309) 786-5075
BLACK HILLS NATIONAL CEMETERY
RENOVATE AND EXPAND
ADMINISTRATION AND
MAINTENANCE BUILDINGS
884-CM-3015
STURGIS, SOUTH DAKOTA
10/31/2022
C U s e rs \m m a rs h a le k \D o c u m e n ts \1
B
L A
C K
H
IL
L S
N C
A
A R
C H
R m m a rs h a le k .r v t
/1 /2
:4
:0
A
M
GI111-1001
FIRST & BASEMENT LEVEL LIFE
SAFETY PLANS 1001
10/31/2022 LA MMM16409
1/8" = 1'-0"
FIRST LEVEL LIFE SAFETY PLAN
1/8" = 1'-0"
BASEMENT LEVEL LIFE SAFETY PLAN
0 8' 16'4'0 8' 16'4'
PLAN
NORTH
TRUE
NORTH
PLAN
NORTH
TRUE
NORTH
Revisions: Date:
sbetker
FD
FD
FD
FD
NOYES
APPLICABLE REGULATIONS
GENERAL TYPE OF PROJECT
NFPA NATIONAL FIRE CODES (EXCEPTION: NFPA 5000 & 900)
2018 NFPA 101 (LIFE SAFETY CODE)
ABA STANDARDS (2015) (ABAAS)
2018 IBC
REMODEL
ADDITION
NEW BUILDING
PROJECT DESCRIPTION
CODE SUMMARY
CONSTRUCT APPROXIMATELY 1,000 GSF ADDITION TO EXISTING
2,780 GSF MAINTENANCE BUILDING. TYPE V (000)
CONSTRUCTION. REMODEL APPROXIMATELY 1,100 GSF IN
EXISTING SPACE. UPGRADE FACILITIES TO ACCESSIBILITY
CODE.
VA BARRIER FREE DESIGN STANDARD (PG-18-13)
NOYESAUTHORITIES HAVING JURISDICTION (AHJ's)
THE JOINT COMMISSION (TJC)
CENTER FOR MEDICARE/MEDICAID SERVICES (CMS)
TESTRATING (HRS)
TOTAL
EXTERIOR DOORS AND WINDOWS
EXIT PASSAGEWAYS
OTHER
ROOF CONSTRUCTION
PRIME & SEC. FLOOR BEAMS, JOISTS
FLOOR/CEILING ASSEMBLY
FLOOR CONSTRUCTION
INTERIOR
NON-BEARING WALLS AND PARTITIONS
BEARING WALLS
COLUMNS
GIRDERS
TRUSSES
ROOF/CEILING ASSEMBLY
PRIME & SEC. ROOF BEAMS, JOISTS
EXTERIOR
INTERIOR BEARING WALLS
EXTERIOR BEARING WALLS
STRUCTURAL FRAME
AREA SEPARATIONS / FIRE WALLS
FIRE-RESISTIVE REQUIREMENTS
TYPE(S) OF CONSTRUCTION
ACTUAL AREA PER FLOOR
CONSTRUCTION TYPE(S)
ADDITION
EXISTING
NONE
PLUMBING FIXTURES
TOILETS
LAVATORIES
DRINKING FOUNTAINS
SERVICE SINKS
PROVIDED RQD FACTOR
1 M, 1 F 1/25 for first 50 occupants, then 1/50 1/40 for first 80 occupants, then 1/80 1/100 occupants. 50% may be vending1
OCCUPANT LOAD OF BUILDING
SF/OCCUPANT OCCUPANTSAREA
TOTAL OCCUPANTS:
2,780 GSF
1,000 GSF
3,780 GSF
50 SF / OCC. 7 OCC.
ZERO NA
NA
(IBC CH 29)
TYPE V [000] (NFPA 220 TABLE 4.1.1)
OSHA STANDARDS
VA SEISMIC DESIGN REQUIREMENTS H-18-8
NATIONAL ELECTRIC CODE (NEC)
ASME BOILER AND PRESSURE VESSEL CODE
ASME CODE FOR PRESSURE PIPING
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE,
AMERICAN CONCRETE INSTITUTE AND COMETARY (ACI 318)
MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE
FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL STEEL
BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
ENERGY POLICY ACT OF 2005 (EPAct)
DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS
FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE
RESIDENTIAL BUILDINGS AND NEW LOW-RISE RESIDENTIAL
BUILDINGS, 10 CFR PARTS 433,434 AND 435
FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE
BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
EXECUTIVE ORDER 13834
THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED
IN THE GENERAL REQUIREMENTS SECTION 01010 OF THE VA
MASTER CONSTRUCTION SPECIFICATION
VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE
STANDARD 62.1-2004
SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE
STANDARD 15 -2007
VA FIRE PROTECTION DESIGN MANUAL
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA
NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER
GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL)
MEANS OF EGRESS CAPACITY (width in inches)
EGRESS
36 INCHES
ACCESSIBLE MEANS OF EGRESS ("MOE") REQUIRED
NO CHANGE
BUILDING HEIGHT
(IBC Section 503)ALLOWABLE AREA PER FLOOR
BASIC ALLOWABLE AREA
NOYES
(Section 8.3)
CHANGE OF OCCUPANCY?
SEPARATED OCCUPANCIES?
FIRE BARRIER RATING(S) SEE LIFE SAFETY PLANS
OCCUPANCY CLASSIFICATION(S)
OCCUPANCIES
(If Remodeling)
2018 LSC (TABLE 6.1.14.1)
SPECIAL PURPOSE INDUSTRIAL
NOYES
FIRE RESISTIVE CORRIDORS?
SMOKE TIGHT CORRIDORS (SMOKE PARTITIONS)
MISCELLANEOUS
INTERIOR FINISHES CLASSIFICATION B
9,000 GSF
1 M, 1 F2 M, 1 F
4 M, 1 F
NA
NA
NA
NA
ZERO
ZERO
ZERO
ZERO
ZERO
ZERO / 1-HR UL U419
ZERO NA
ZERO NA
ZERO / 1-HR UL K506
ZERO NA
ZERO NA
ZERO NA
FULLY SPRINKLERED BUILDING
BUSINESS
COLLABORATION:
BUSINESS
CONCENTRATED:
330 GSF
352 GSF
30 SF / OCC. 11 OCC.
41 OCC.
INDUSTRIAL, SPECIAL:
STORAGE: 357 GSF 5 OCC.
1,798 GSF 18 OCC.
MAX PROBABLE
MAX PROBABLE
EXITEXIT
100'-0"
TRAVEL DISTANCE
125 SF
FOREMANS
OFFICE
86 SF
OPEN
OFFICE
73 SF
MECHANICAL
83 SF
EYEWASH/
BOOT WASH
470 SF
GARAGE
BAY 2
229 SF
MEN'S
LOCKERS
126 SF
WOMEN'S
LOCKERS
154 SF
HALLWAY
141 SF
MECHANICS
OFFICE
95 SF
DATA/
SECURITY
55 SF
HAC
330 SF
BREAKROOM/
LOUNGE 164 SF
MEN'S
TOILET
50 SF
HALLWAY
73 SF
HALLWAY
E X
IS
T
IN
G
'-4
A
D D
IT
IO
N
'-8
61'-4" 44'-4"
ATTIC ACCESS LADDER.
F.E.
EXIST
F.E.
EXIST
FLAMMABLE
STORAGE
EQUIPMENT
STORAGE10
BAY 1
44'-0"
EYE/FACE WASH
ATTIC ACCESS LADDER.
62'-0"
TRAVEL DISTANCE
LIFE SAFETY SYMBOLS
SMOKE TIGHT
ASSEMBLY
1 HOUR FIRE
BARRIER
1 HOUR FIRE &
SMOKE BARRIER
TRAVEL DISTANCE
100'-10"
TRAVEL DISTANCE
EXIT EXIT
FIRE
EXTINGUISHER
FE
FIRE
EXTINGUISHER
CABINET
FEC
LIMITS OF
CONSTRUCTION
NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN
COMMON PATH
MECH ATTIC
EXIST MECH ATTIC
EXIST
ATTIC
ACCESS
PROPOSED
ATTIC
ACCESS
E X
IS
T
IN
G
'-4
A
D D
IT
IO
N
'-8
/4
61'-4" 44'-4"
44'-0"
DATE:
License #
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
SUBMITTAL
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GEOTECHNICAL:
AET
1745 SAMCO RD
RAPID CITY, SD 57702
(605) 223-4397
COST ESTIMATING:
CPMI
3265 NORTHWOOD CIR STE 170
EAGAN, MN 55121
(952) 854-3663
MECHANICAL, ELECTRICAL,
TECHNOLOGY & STRUCTURAL:
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
(309) 786-5075
BLACK HILLS NATIONAL CEMETERY
RENOVATE AND EXPAND
ADMINISTRATION AND
MAINTENANCE BUILDINGS
884-CM-3015
STURGIS, SOUTH DAKOTA
10/31/2022
C U s e rs \P u b lic
\D o c u m e n ts
\R e v it P ro je c ts
\1
B
L A
C K
H
IL
L S
N C
A M
A
IN
T A
IN
A
N C
E A
R C
H E
M a rk fo rt .r v t
/3 /2
:0
:4
P M
GI111-3001
LIFE SAFETY PLAN
10-31-22 LA EM16409
1/8" = 1'-0"
FIRST LEVEL LIFE SAFETY PLAN - MAINTENANCE 3001
0 8' 16'4'
PLAN
NORTH
TRUE
NORTH
1/8" = 1'-0"
ATTIC LIFE SAFETY PLAN - MAINTENANCE 3001
0 8' 16'4'
PLAN
NORTH
TRUE
NORTH
ROOM USE AREAS
RM NO. NAME AREA
3 WOMEN'S LOCKERS 126 SF
7 EYEWASH/ BOOT WASH 83 SF
8 MEN'S LOCKERS 229 SF
9 GARAGE 470 SF
10 BAY 1 541 SF
11 BAY 2 349 SF
0-INDUSTRIAL 1798 SF
6 MECHANICAL 73 SF
12 EQUIPMENT STORAGE 86 SF
13 FLAMMABLE STORAGE 48 SF
18 DATA/ SECURITY 95 SF
19 HAC 55 SF
1-STORAGE 357 SF
1 OPEN OFFICE 86 SF
2 FOREMANS OFFICE 125 SF
17 MECHANICS OFFICE 141 SF
2-BUSINESS CONCENTRATED 352 SF
14 BREAKROOM/ LOUNGE 330 SF
3-BUSINESS COLLABORATION 330 SF
Revisions: Date:
sbetker
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 v a nc a re no va te a dm in b ld gs b la ck h ill s nc s ur ve y\ _0 ca d fil es \1
_s _b as e.
dw ka hl av ed :9
/2 0/
:4 lo t:1
0/
/2
1:
P
M
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15785
BLACK HILLS NATIONAL CEMETERY 884-CM-3015
10-31-22
STURGIS, SOUTH DAKOTA
BID DOCUMENTS
SUBMITTAL
Date:
RENOVATE AND EXPAND
ADMINISTRATION AND
MAINTENANCE BUILDINGS
GEOTECHNICAL
AET
1745 SAMCO RD
RAPID CITY, SD 57702
(605) 223-4397
COST ESTIMATING
CPMI
3265 NORTHWOOD CIR STE 170
EAGAN, MN 55121
(952) 854-3663
MECHANICAL, ELECTRICAL,
TECHNOLOGY & STRUCTURAL
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
(309) 786-5075
OF 84
Office of Design and Construction
(TYP)
EXISTING CONDITIONS SURVEY
VF-100
DGES 6
AutoCAD SHX Text 83.2
AutoCAD SHX Text 25.3
AutoCAD SHX Text 83.2
AutoCAD SHX Text 25.3
AutoCAD SHX Text 44.4
AutoCAD SHX Text 32.2
AutoCAD SHX Text 6.2
AutoCAD SHX Text 59.9
AutoCAD SHX Text 26.1
AutoCAD SHX Text 104.2
AutoCAD SHX Text 105.5
AutoCAD SHX Text 105.7
AutoCAD SHX Text 26.4
AutoCAD SHX Text 26.5
AutoCAD SHX Text 21.2
AutoCAD SHX Text 20.2
AutoCAD SHX Text 4.4
AutoCAD SHX Text 46.2
AutoCAD SHX Text 30.1
AutoCAD SHX Text 13.7
AutoCAD SHX Text 8.0
AutoCAD SHX Text 18.9
AutoCAD SHX Text 8.0
AutoCAD SHX Text 13.6
AutoCAD SHX Text 4.5
AutoCAD SHX Text 7.5
AutoCAD SHX Text 5.3
AutoCAD SHX Text 6.3
AutoCAD SHX Text 6.4
AutoCAD SHX Text 5.3
AutoCAD SHX Text 9.2
AutoCAD SHX Text 7.3
AutoCAD SHX Text
CONCRETE CURB
AutoCAD SHX Text
CONCRETE CURB
AutoCAD SHX Text
CONCRETE CURB
AutoCAD SHX Text
CONCRETE CURB
AutoCAD SHX Text
CONCRETE CURB
AutoCAD SHX Text
CONCRETE CURB
AutoCAD SHX Text
CONCRETE CURB
AutoCAD SHX Text D R A I N F I E L D S
AutoCAD SHX Text
ABANDONED DRAIN FIELD
AutoCAD SHX Text
6" WATER
AutoCAD SHX Text
RIM=3630.6 INV=3624.3
AutoCAD SHX Text
24" RCP
AutoCAD SHX Text
INV=3621.3
AutoCAD SHX Text
12"RCP
AutoCAD SHX Text
RIM=3626.6 INV=3624.4
AutoCAD SHX Text
RIM=3626.8 INV=3624.5
AutoCAD SHX Text
RIM=3625.7 INV=3624.5 12" RCP
AutoCAD SHX Text
FES=3624.1
AutoCAD SHX Text
RIM=3623.9 INV=3621.4 NO OUTLET
AutoCAD SHX Text
GARAGE FLOOR = 3624.7
AutoCAD SHX Text
GARAGES
AutoCAD SHX Text
GARAGE FLOOR = 3626.2
AutoCAD SHX Text
GARAGE FLOOR = 3626.0
AutoCAD SHX Text
GARAGES
AutoCAD SHX Text
MAINTENANCE BUILDING
AutoCAD SHX Text
ADMINISTRATION BUILDING
AutoCAD SHX Text
FLOOR ELEVATION= 3634.0
AutoCAD SHX Text
FLOOR ELEVATION= 3632.8
AutoCAD SHX Text
CELLAR DOOR
AutoCAD SHX Text
GATE
AutoCAD SHX Text
ELECTRICAL CONDUIT BOX
AutoCAD SHX Text
12" CAPPED PIPES
AutoCAD SHX Text
RAPID CITY, PIERRE & EASTERN RAILROAD (DEPICTED FOR REFERENCE ONLY)
AutoCAD SHX Text
ELECTRICAL SWITCH
AutoCAD SHX Text
ROOFED STORAGE BAYS
AutoCAD SHX Text
ELECTRICAL SWITCH
AutoCAD SHX Text
WINDOW WELLS (TYP)
AutoCAD SHX Text
POSSIBLE FUEL STORAGE
AutoCAD SHX Text
CONDUIT INTO BUILDING
AutoCAD SHX Text
WALL MOUNTED COMPRESSOR
AutoCAD SHX Text
TANK
AutoCAD SHX Text
ELECTRICAL INTO BUILDING
AutoCAD SHX Text
1" PVC FOR TELEPHONE
AutoCAD SHX Text
2" PVC FOR TELEPHONE
AutoCAD SHX Text
PUMP HOUSE
AutoCAD SHX Text
FUEL
AutoCAD SHX Text
FENCE WITH BRICK POST
AutoCAD SHX Text
DRAINAGE DIRECTION
AutoCAD SHX Text
CONCRETE CURB
AutoCAD SHX Text S E C T I O N A
AutoCAD SHX Text S E C T I O N B
AutoCAD SHX Text S E C T I O N E
AutoCAD SHX Text
SECTION MB
AutoCAD SHX Text
SANITARY LINE SCALED IN PER AVAILABLE MAPPING
AutoCAD SHX Text
BLDG 1001
AutoCAD SHX Text
BLDG 3001
AutoCAD SHX Text Dated: December 14, 2021
AutoCAD SHX Text I hereby certify that this survey was prepared by me or under my direct supervision and that I am a duly Licensed Surveyor under the laws of the State of South Dakota.
AutoCAD SHX Text 20901 Pleasant Valley Drive, Sturgis, South Dakota.
AutoCAD SHX Text
CERTIFICATION:
AutoCAD SHX Text
PROPERTY ADDRESS:
AutoCAD SHX Text by:
AutoCAD SHX Text David Anderson South Dakota License No. 8385
AutoCAD SHX Text Anderson Engineering of Minnesota, LLC
AutoCAD SHX Text
SURVEY NOTES:
AutoCAD SHX Text The horizontal datum and bearings are based on the South Dakota State Plane Coordinate System, South Zone NAD83(2011), U.S. Survey feet. The scaleable information depicted hereon are in grid distances. The grid distance to ground distance scale factor is 1.00151764. The coordinates depicted hereon were established using the National Geodetic Survey's Online Positioning User Service (OPUS).
AutoCAD SHX Text The vertical datum is NAVD88. The site benchmark is a 5/8 Inch by 18 Inch rebar with a pink plastic cap stamped "CONTROL POINT", located at the tee of the entrance road at Section MA (depicted hereon). Elevation = 3,639.86 feet.
AutoCAD SHX Text 2.
AutoCAD SHX Text 1.
AutoCAD SHX Text 3.
AutoCAD SHX Text The tree information shown hereon was collected during the field survey by non-forestry trained Anderson Engineering of Minnesota survey personnel. Tree sizes are estimates and locations are accurate to plus or minus three feet.
AutoCAD SHX Text 4.
AutoCAD SHX Text No title work was provided for the preparation of this survey to verify the legal description or the existence of any easements or encumbrances.
AutoCAD SHX Text 5.
AutoCAD SHX Text The location and extent of underground utilities, if shown, are based upon existing drawings provided by the National Cemetery, above ground evidence and South Dakota 811 Locate markings per ticket number 2130621634. However, lacking excavation, the exact location of underground features cannot be accurately, completely, and reliably depicted. In addition, in some jurisdictions, 811 or other similar utility locate requests from surveyors may be ignored or result in an incomplete response. The size and location of utilities shown should be considered approximate. Additional underground utilities may be present. Verification of the existence and location of all utilities should be obtained from the utility owners prior to any planning or design. In accordance with State Statute, the location of utilities shall be confirmed prior to any demolition or construction.
AutoCAD SHX Text
SITE BENCHMARK:
AutoCAD SHX Text NORTHING = 215,137.42 = 215,137.42 EASTING = 1,060,012.21 = 1,060,012.21 ELEVATION = 3,639.86= 3,639.86
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text
HHE
AutoCAD SHX Text R
AutoCAD SHX Text
EM
AutoCAD SHX Text S
AutoCAD SHX Text J
AutoCAD SHX Text
CO
AutoCAD SHX Text H
AutoCAD SHX Text X
AutoCAD SHX Text
UE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GAS
AutoCAD SHX Text X
AutoCAD SHX Text I
AutoCAD SHX Text W
AutoCAD SHX Text
SP
AutoCAD SHX Text
EB
AutoCAD SHX Text C
AutoCAD SHX Text
AIR CONDITIONER
AutoCAD SHX Text
CATCH BASIN
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
COMM. JUNCTION BOX
AutoCAD SHX Text
CONTROL POINT
AutoCAD SHX Text
CULVERT
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
ELECTRIC MANHOLE
AutoCAD SHX Text
ELECTRIC METER
AutoCAD SHX Text
GUARD POST
AutoCAD SHX Text
HANDICAP PARKING
AutoCAD SHX Text
HANDHOLE
AutoCAD SHX Text
HANDHOLE ELECTRIC
AutoCAD SHX Text
IRRIGATION CONTROL BOX
AutoCAD SHX Text
IRRIGATION CONTROL VALVE
AutoCAD SHX Text
LIGHT POLE
AutoCAD SHX Text
MANHOLE
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
SANITARY MANHOLE
AutoCAD SHX Text
SIGN
AutoCAD SHX Text
SPRINKLER HEAD
AutoCAD SHX Text
STOP BOX
AutoCAD SHX Text
WATER MANHOLE
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
CONIFEROUS TREE
AutoCAD SHX Text
DECIDUOUS TREE
AutoCAD SHX Text
COMMUNICATION
AutoCAD SHX Text
FENCE
AutoCAD SHX Text
GAS MAIN
AutoCAD SHX Text
HANDRAIL
AutoCAD SHX Text
SANITARY SEWER
AutoCAD SHX Text
STORM SEWER
AutoCAD SHX Text
UNDERGROUND ELECTRIC
AutoCAD SHX Text
WATER MAIN
AutoCAD SHX Text
BITUMINOUS SURFACE
AutoCAD SHX Text
CONCRETE SURFACE
AutoCAD SHX Text
GRAVEL SURFACE
AutoCAD SHX Text
LANDSCAPE ROCK
AutoCAD SHX Text
PAVER SURFACE
AutoCAD SHX Text
RIP-RAP
AutoCAD SHX Text
WALL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text
SCALE IN FEET
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text National Cemetery Administration.
AutoCAD SHX Text
SURVEY FOR:
AutoCAD SHX Text
STUMP
AutoCAD SHX Text
RCP
AutoCAD SHX Text
REINFORCED CONCRETE PIPE
AutoCAD SHX Text Utilities Underground Location Center
AutoCAD SHX Text
CALL 48 HOURS BEFORE DIGGING
AutoCAD SHX Text
DIAL 811
AutoCAD SHX Text Know what's
AutoCAD SHX Text below
AutoCAD SHX Text
AutoCAD SHX Text Call
AutoCAD SHX Text before you dig.
sbetker
FFE = 3624.7
EX. G
ARAGE
FFE = 3626.2
EX. G
ARAGE
FFE = 3626.0
EX. A
DMIN BUILDING
FFE = 3634.0
RAPID CITY, PIERRE &
EASTERN RAILROAD
PROPERTY LINE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 v a nc a re no va te a dm in b ld gs b la ck h ill s nc c iv il\
_0 ca d fil es s he et s\
9_ c_ de m o.
dw jd ob ia d:
/3
1/
1:
lo t:1 0/
/2
1:
P M
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15785
BLACK HILLS NATIONAL CEMETERY 884-CM-3015
10-31-22
STURGIS, SOUTH DAKOTA
BID DOCUMENTS
SUBMITTAL
Date:
RENOVATE AND EXPAND
ADMINISTRATION AND
MAINTENANCE BUILDINGS
GEOTECHNICAL
AET
1745 SAMCO RD
RAPID CITY, SD 57702
(605) 223-4397
COST ESTIMATING
CPMI
3265 NORTHWOOD CIR STE 170
EAGAN, MN 55121
(952) 854-3663
MECHANICAL, ELECTRICAL,
TECHNOLOGY & STRUCTURAL
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
(309) 786-5075
OF 84
Office of Design and Construction
(TYP)
CONSTRUCTION LIMITS
EXISTING SANITARY PIPE
EXISTING STORM SEWER PIPE
EXISTING WATERMAIN PIPE
REMOVE CONCRETE CURB &
GUTTER
REMOVE CONCRETE PAVEMENT
REMOVE ASPHALT PAVEMENT
REMOVE EXISTING UTILITY
SAWCUT
SILT FENCE
INLET PROTECTION
ROCK CONSTRUCTION ENTRANCE
REMOVE LANDSCAPE
CONSTRUCTION FENCE
N
0 20' 40'
LEGEND
KEYNOTES
GENERAL NOTES:
1. UTILITY REMOVALS ARE BASED ON SURVEY INFORMATION,
ASBUILT PLANS, AND GROUND PENETRATING RADAR SURVEY.
UTILITY INFORMATION MAY BE INACCURATE AND INCOMPLETE.
SHOULD CONTRACTOR ENCOUNTER UTILITIES NOT SHOWN,
CONTRACTOR SHALL IMMEDIATELY CONTACT COR AND ENGINEER.
2. ALL UTILITIES NOT MARKED FOR REMOVAL SHALL BE PROTECTED
FROM DAMAGE.
3. REMOVE AND RELOCATE ALL IRRIGATION LINES, HEADS, VALVES,
BOXES, ETC. AS NECESSARY. REPLACE AS NECESSARY.
CONTRACTOR TO SECURE WORK AREA AS
NECESSARY TO PROTECT THE GENERAL PUBLIC
FROM HARM. CONTRACTOR MAY USE TRAFFIC
SIGNS/BARRIERS AS NECESSARY. ANY ROAD
CLOSURES SHALL BE APPROVED BY THE NCA
PRIOR TO SHUT DOWN. ADDITIONAL TRAFFIC
SIGNAGE WILL BE NECESSARY.
CONSTRUCTION LIMITS
(TYP.)
CONSTRUCTION LIMITS
(TYP.)
4 2
DEMOLITION & SEDIMENT EROSION
CONTROL PLAN
D-101
JDES 7
CONSTRUCTION LIMITS
(TYP.)
24 25
REPLACE ALL
DEMOLISHED
SURFACES IN-KIND
REMOVE SANITARY SEWER PIPE
REMOVE EXISTING STORM SEWER
CASTING
REMOVE & REROUTE COMMUNICATION
LINE
REMOVE ASPHALT PAVEMENT
REMOVE CONCRETE PAVEMENT
SAWCUT LINE AT NEAREST JOINT
PROTECT TREES (TYP)
REMOVE EXISTING SURMOUNTABLE CURB
& GUTTER
TEMPORARY FENCE GATE
INSTALL & MAINTAIN SILT FENCE
PERIMETER SEDIMENT PROTECTION IN
TURF AREAS. USE BIO-ROLLS AS NEEDED
IN PAVED AREAS FOR PHASING
PURPOSES.
INSTALL & MAINTAIN INLET SEDIMENT
PROTECTION.
INSTALL TEMPORARY ROCK ENTRANCE AT
CONSTRUCTION INGRESS & EGRESS
LOCATION(S) PRIOR TO EXCAVATION & TO
BE MAINTAINED THROUGHOUT THE ENTIRE
CONSTRUCTION PROCESS. VERIFY
LOCATION IN FIELD W/ P.M.
PROTECT EXISTING A/C UNIT
PROTECT EXISTING SEPTIC DRAIN FIELD.
VERIFY EXTENTS OF DRAIN FIELD &
ADJUST PROJECT LIMIT LINE AS
NECESSARY.
REMOVE STAIRS
REMOVE & RELOCATE ELECTRICAL BOX
PER ELECTRICAL PLANS.
REMOVE WATER VALVE.
18 REMOVE WATER MAIN & VALVES TO TEE.
CAP LINE AT TEE.
REMOVE SIDEWALK
REMOVE AND REPLACE ROOFDRAIN
REPLACE DAMAGED CURB AND GUTTER
AND SIDEWALK ONCE BLDG ADDITIONS
ARE COMPLETE
PROTECT EXISTING SANITARY LINE.
CAMERA BEFORE & AFTER TO VERIFY NO
DAMAGE HAS OCCURED. CAMERA
LENGTH TO STOP UNDER STREET.
REMOVE TREE & REPLACE. TYPE &
LOCATION DETERMINED BY P.M.
APPROXIMATE GRAVE SITES. VERIFY
CONSTRUCTION LIMITS W/ P.M. PRIOR TO
WORK.
REMOVE GAS LINE TO OUTSIDE OF NEW
BUILDING FOOTPRINT. INSTALL NEW LINE
AS NECESSARY. FOLLOW MECHANICAL
PLANS.
AutoCAD SHX Text 83.2
AutoCAD SHX Text 25.3
AutoCAD SHX Text 83.2
AutoCAD SHX Text 25.3
AutoCAD SHX Text 44.4
AutoCAD SHX Text 32.2
AutoCAD SHX Text 6.2
AutoCAD SHX Text 59.9
AutoCAD SHX Text 26.1
AutoCAD SHX Text 104.2
AutoCAD SHX Text 105.5
AutoCAD SHX Text 105.7
AutoCAD SHX Text 26.4
AutoCAD SHX Text 26.5
AutoCAD SHX Text 21.2
AutoCAD SHX Text 20.2
AutoCAD SHX Text 4.4
AutoCAD SHX Text 46.2
AutoCAD SHX Text 30.1
AutoCAD SHX Text 13.7
AutoCAD SHX Text 8.0
AutoCAD SHX Text 18.9
AutoCAD SHX Text 8.0
AutoCAD SHX Text 13.6
AutoCAD SHX Text 4.5
AutoCAD SHX Text 7.5
AutoCAD SHX Text 5.3
AutoCAD SHX Text 6.3
AutoCAD SHX Text 6.4
AutoCAD SHX Text 5.3
AutoCAD SHX Text 9.2
AutoCAD SHX Text 7.3
AutoCAD SHX Text D R A I N F I E L D S
AutoCAD SHX Text
ABANDONED DRAIN FIELD
AutoCAD SHX Text
6" WATER
AutoCAD SHX Text
RIM=3630.6 INV=3624.3
AutoCAD SHX Text
24" RCP
AutoCAD SHX Text
12"RCP
AutoCAD SHX Text
RIM=3626.6 INV=3624.4
AutoCAD SHX Text
RIM=3626.8 INV=3624.5
AutoCAD SHX Text
RIM=3625.7 INV=3624.5 12" RCP
AutoCAD SHX Text
FES=3624.1
AutoCAD SHX Text
RIM=3623.9 INV=3621.4 NO OUTLET
AutoCAD SHX Text S E C T I O N A
AutoCAD SHX Text S E C T I O N B
AutoCAD SHX Text S E C T I O N E
AutoCAD SHX Text
SECTION MB
AutoCAD SHX Text Utilities Underground Location Center
AutoCAD SHX Text
CALL 48 HOURS BEFORE DIGGING
AutoCAD SHX Text
DIAL 811
AutoCAD SHX Text Know what's
AutoCAD SHX Text below
AutoCAD SHX Text
AutoCAD SHX Text Call
AutoCAD SHX Text before you dig.
AutoCAD SHX Text
9172 ROGER A. ANDERSON
sbetker
FFE = 3624.7
EX. G
ARAGE
FFE = 3626.2
EX. G
ARAGE
FFE = 3626.0
EX. A
DMIN BUILDING
FFE = 3634.0
BLDG ADDITION
FFE = 3626.0
RAPID CITY, PIERRE &
EASTERN RAILROAD
PROPERTY LINE
BLDG ADDITION
FFE = 3634.0
CO
CO
BLDG 1001
BLDG 3001
Project Number
Building Number
Drawing Number
Project Title
Location
Issu…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .