Attachment 2 - Capability Characteristics (9-30-2025).docx

DOCX document 35 KB Posted

Attached to
Advanced Ultrasound Capability
Solicitation number
HT9425-25-RFI-AUC
Issued by

About this file

This document is an Attachment to a Request for Information (RFI) for Advanced Ultrasound Capability, issued by the Defense Health Agency's Operational Medical Systems (OPMED) Warfighter Expeditionary Medicine and Treatment Project Management Office. The detailed capability characteristics document outlines comprehensive technical requirements for an advanced ultrasound system, focusing on three primary assessment areas: general characteristics, software-related characteristics, and hardware-related characteristics.

The RFI seeks a commercial solution that can address medical data management, patient tracking, and triage enhancement, particularly for less skilled medical professionals in expeditionary settings. Key technical requirements include FDA clearance, network integration capabilities, AI-powered features like guided-needle placement and automated anatomical labeling, hardware specifications (size, weight, battery power), and advanced diagnostic capabilities beyond current Focused Assessment with Sonography for Trauma (FAST) standards. The document provides a structured template for potential vendors to detail their system's current capabilities and future development plans across technological, software, and hardware dimensions.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 2 – Capability Characteristics

ADVANCED ULTRASOUND CAPABILITY CHARACTERISTICS

CHARACTERISTICS: The below are essential characteristics for an advanced ultrasound capability.

Instructions: Indicate if current system meets the characteristics for general, software-, and hardware-related components. If proposed system does NOT currently meet the characteristic, please include a brief statement/proposed plan if the characteristic will be met. Please note, if the capability is software-only, and hardware agnostic, information in the “Hardware-related Characteristics” table does not need to be filled out.

General Characteristics No.

Characteristic

Characteristic Description

Describe the characteristic as related to the system. If indicated N/A, please elaborate if the product plans to integrate or achieve this characteristic in the future.

Additional information, as necessary

1
FDA
The solution should explicitly state its current FDA status, indicating whether it is planning to obtain, or has already obtained, FDA clearance/approval (FDA clearance/ approval should be attached).
2
Technology Readiness Level (TRL)
The solution should explicitly state its current TRL (See provided definitions).
3
Network Integration
Demonstrates the ability to integrate into existing commercial or military network infrastructures.
4
Network Connectivity
Describe if the system can turn on/off Wi-Fi and Bluetooth capabilities.
5
Authority-to-Operate (ATO)
The solution should explicitly state its current ATO status.

Software-related Characteristics No.

Characteristic

Characteristic Description

Describe the characteristic as related to the system. If indicated N/A, please elaborate if the product plans to integrate or achieve this characteristic in the future.
Additional information, as necessary
1
Artificial Intelligence (AI)
Indicate the type of AI software, including but not limited to:

a. Guided-needle placement assistance.

b. Automated anatomical labeling.

c. Segmentation, measurement, and calculation tools.

d. Automated image-quality determination.

e. Diagnostic support features.

f. Telehealth connectivity.

g. Other.

2
Application/software storage size
Describe the storage size for the software (preferably in gigabytes).
3
Hardware-agnostic
Indicate if the software is hardware-agnostic and works with existing ultrasound hardware.
4
Operating System
Indicate the primary operating system(s) which the application functions (i.e. iOS, Android, etc.).
5
Software Update Requirements
Describe the cadence of software updates for the software.

Hardware-related Characteristics No.

Characteristic

Characteristic Description

Describe the characteristic as related to the system. If indicated N/A, please elaborate if the product plans to integrate or achieve this characteristic in the future.

Additional information, as necessary

1
Size
Indicate the length, width, and height of the full system. If component sizes are available, please denote them.
2
Weight
Indicate the weight of the full system. If component sizes are available, please denote them.
3
Battery Power
Describe the battery type and operational time of battery power when not plugged into a direct power source.
4
Power Source
Indicate the system’s VAC/Hz power considerations and the type of charging port (e.g., USB-C, USB, etc.).
5
Advanced diagnostic capability
Indicate if the system performs beyond current assessments for Focused Assessment with Sonography for Trauma (FAST), extended-FAST (eFAST), and musculoskeletal injury assessment.

(end of Advanced Ultrasound Capability Characteristics)