About this file

This document is a bid specification from the California Department of Forestry and Fire Protection (CAL FIRE) for the procurement of personal protective equipment (PPE) extractors and dryers. The specification defines the technical requirements for these devices, which must meet the current edition of NFPA 1851 and NFPA 1877 standards. The extractors must be front-loading, have programmable features, and a maximum cylinder speed of 100G. The tumble dryers and portable dryers must have a maximum drying temperature of 105°F and be electric or gas-powered, with NFPA 1851-compliant drying cycles.

The bid specification does not provide information on quantities, response dates, award dates, or contract term. It also does not mention any pricing terms, set-asides, incumbents, funding requirements, or other salient commercial details.

View the file

Other files

File Type Posted
Addendum_Cover_Sheet_Addendum_3.docx DOCX document
Attachment_2A_-_Technical_Questionnaire_3510-TQ-0189764.xlsx XLSX spreadsheet
Attachment_3_-_Narrative_Response.docx DOCX document
APP_Cover_Page.docx DOCX document
IFB_Event_ID_0000030279_Addendum_2.docx DOCX document
Question___Answer_Set_1.docx DOCX document
Addendum_Cover_Sheet_Addendum_4.docx DOCX document
Question___Answer_Set_2.docx DOCX document
Addendum_Cover_Sheet_Addendum_2.docx DOCX document
IFB_Event_ID_0000030279_Addendum_4.docx DOCX document
Attachment_1_-_Pricing_Workbook.xlsx XLSX spreadsheet
IFB_Event_ID_0000030279.docx DOCX document
Addendum_Cover_Sheet_Addendum_1.docx DOCX document
Attachment_1_addendum_1-_Pricing_Workbook.xlsx XLSX spreadsheet
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

State of California Extractors and Dryers

California Department of Forestry and Fire Protection

Bid Spec 3510-BS-0189764 Event ID 0000030279

Attachment 2

Velazquez, I. Page 1 of 3 July 2, 2024

Document Summary Detail Type Detail Event ID 0000030279 Commodity Extractors and dryers for personal protective equipment Group-Class 3510 Bid Specification 3510-BS-0189764 Release Date July 2, 2024 Agency Name California Department of Forestry and Fire Protection

Revision History Spec Rev Rev Date Author Summary of Changes 3510-0189764 N/A N/A Velazquez, I Initial release

DGS PD Extractors and Dryers 3510-BS-0189764

Velazquez, I. Page 2 of 3 July 2, 2024

1. SCOPE

This specification defines the technical requirements for personal protective equipment (PPE) extractors and dryers to be used by California Department of Forestry and Fire Protection (CAL FIRE) personnel. The extractors and dryers shall be suitable for use with wildland and structural firefighting PPE ensemble elements including but not limited to structural turnout coats & pants, particulate blocking hoods, wildland jackets, dual compliant single layer pants, and wildland shrouds.

2. APPLICABLE LAWS and INDUSTRY STANDARDS The following standards, laws, regulations, and codes of the issue in effect on the date of the Invitation for Bid form (IFB) are part of this specification to the extent specified herein. Any applicable laws, regulations, codes, industry standards, or manufacturing standards, though not specifically cited, shall apply.

2.1 Laws, Regulations, and Codes

2.1.1 California Code of Regulations (CCR), Title 8, Article 10.1, Section

3402.3, Selection, Inspection, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting

2.1.2 CCR, Title 8, Article 10.1, Section 3410, Selection, Inspection, and Maintenance of Protective Ensembles for Wildland Fire Fighting

2.2 Industry Standards

2.2.1 National Fire Protection Association (NFPA) 1851, Standard on

Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting, current edition

2.2.2 NFPA 1877, Standard on Selection, Care, and Maintenance of Wildland Firefighting Protective Clothing and Equipment, current edition

3. TECHNICAL REQUIREMENTS

3.1 Extractors

3.1.1 Extractors must meet the requirements of the current edition of NFPA 1851, Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting.

3.1.2 Extractors must be front loading.

3.1.3 Extractors must meet the requirements of the NFPA 1851 wash cycles, including the following programmable features, at time of delivery:

a. Detergent application

b. Water temperature

c. Water level

d. Cycle type

e. Cycle function

f. Cycle time

3.1.4 Extractors must be equipped with a chemical dosing, two solution pump, that is pre-configured to the extractor and detergent.

3.1.5 The maximum cylinder speed must be 100G.

DGS PD Extractors and Dryers 3510-BS-0189764

Velazquez, I. Page 3 of 3 July 2, 2024

3.2 Tumble Dryers

3.2.1 Tumble dryers must meet the requirements of the current edition of the

NFPA 1851, Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting.

3.2.2 Tumble dryers must have a maximum drying temperature of 105 °F.

3.2.3 Tumble dryers must be of electric or gas configuration.

3.2.4 Tumble dryers must be programmed to meet NFPA 1851 drying cycles at the time of delivery.

3.3 Portable Dryers

3.3.1 Portable dryers must meet the requirements of the current edition of the NFPA 1851, Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting.

3.3.2 Portable dryers must have a maximum drying temperature of 105 °F.

3.3.3 Portable dryers must be of electric configuration.

3.3.4 Portable dryers must be programmed to meet NFPA 1851 drying cycles at the time of delivery.

End of document

Document Summary
Revision History
1. SCOPE
2. APPLICABLE LAWS and INDUSTRY STANDARDS
2.1 Laws, Regulations, and Codes
2.2 Industry Standards
3. TECHNICAL REQUIREMENTS
3.1 Extractors
3.2 Tumble Dryers
3.3 Portable Dryers