Attachment 14 - A402_ INTERIOR ELEVATIONS.pdf

PDF 501 KB Posted

Attached to
20459 - Portage CMS & NMS - Security and Ballistic Window Fi
Solicitation number
RFP PPS 210000001576 1
Issued by
Kalamazoo County, Michigan

About this file

This document is an Interior Elevations sheet (A402) for the North Middle School project in Portage, Michigan, prepared for the Portage Public Schools district. The sheet provides detailed construction specifications and design standards for interior finishes and built-in casework throughout the facility. Key design elements include specifications for casework finishes using various laminate materials (PLAM-1 through PLAM-8), countertops, hardware pulls, wall treatments, lockers, benches, acoustic panels, and tile work. The elevations cover multiple areas including toilet rooms, locker rooms, shower facilities, media centers, science rooms, and corridors across multiple floors. Design details specify paint colors that vary by level (PNT-4 for Level 1, PNT-5 for Level 2, PNT-6 for Level 3), accent wall treatments with orange coloring at center accent walls, wood veneer finishes for corridor window millwork surrounds, and specific tile installation protocols. Materials include porcelain wall tile, CMU wall construction with bullnosed edges, laminated glass, insulated glazing systems, acoustic wall panels in various colors and thicknesses, stainless steel trim accessories, tempered mirrors, and ADA-compliant fixtures.

The document establishes detailed construction standards for all casework, basing the design on Case Systems 2014 product offerings with white melamine interior finishes as standard. Specifications address filler panel requirements at casework installation locations, end panel finishing standards, wall base requirements, and substrate preparation including parge work for CMU walls. Hardware standards mandate ADA-compliant brushed nickel bar pulls with varying lengths depending on application. The sheet was issued as final plans for bidding and construction on March 24, 2017, with reference to architectural specifications for comprehensive installation details and acceptable alternative manufacturers for all specified materials and fixtures.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXTENTS

4' - 0"

PNT-13

EQ.EQ.

AF

F.

T

YP

6"

6'

0"

PNT-13PNT-11

EQ. EQ.

EXTENTS

9' - 6" EQ.

EXTENTS

29' - 0" EQ.

EXTENTS

8' - 0"

7 7 7 7

PNT-13

RWB-7 TYP.

ALL WALL PADS @ CENTER ACCENT WALL SHALL BE ORANGE ALL WALL PADS @ CENTER ACCENT WALL SHALL BE ORANGE

EQ. EQ.

EXTENTS

36' - 0"

6'

0"

AF

F.6"RWB-7 TYP.

7 7

PNT-13

3' - 0"

CL

7'

1/

2"

EXTENTS

28' - 0"

EQ. EQ.

2' - 0" 4"

6'

0"

6" AF

F.

TY

P

PNT-13

RWB-7

TYP.

CP-1

EXTENTS

79' - 0"

EQ. EQ.

6'

0"

AF

F.6"

TYP. TYP.

PNT-13

EQ.EQ.

CL

OUTLINE OF CEILING RECESSED MANUAL

OVERHEAD PROJECTION SCREEN

RWB-7 TYP.

CP-1

C M

U W

A

LL

4'

8"

(2) HIGH STACKED 15" WIDE

LOCKERS BEYOND

4 HIGH STACKED

12" WIDE LOCKERS

6" CMU WALL

WITH CONTINUOUS

BULLNOSED EXPOSED

CORNERS (PNT-13)

LOCKERS

PTB-3

OPEN BEYOND

BF BENCH

AF

F.

1'

8"

4'

8"

4 BF LOCKERS

LOCKERS

PTB-3

PNT-13 TYP.

OPEN BEYOND

ADA BENCH AL4-4

12 BF LOCKERS

8" CMU WITH ALL EXPOSED

EDGES BULLNOSED

4'

8"

PTB-3

4'

0" 6"

LOCKERS

6'

6"

7'

0" 2'

8" PNT-13

PTB-3

LOCKERSFILLER AS

REQ'D, TYP

TYP.

3'

0"4'

0"

4'

6"

PNT-13

12 BF LOCKERS

OPEN BEYOND A1

A431

PTB-3

6'

6"

4'

6"

AF

F.

1'

8"

4 BF LOCKERS

3'

3/

4"

4'

8"

PNT-13 PNT-13

PTB-3

ADA BENCH

OPEN BEYOND

A1 A431

TYP.

PNT-13

RWB-7 TYP.

PNT-13

TV

PNT-13

EQ. EQ.

CL

RWB-7

PNT-11

TYP.

6'

0"

AF

F.

1'

0"

EQ. 16' - 0" EQ.

G6 A433

TY.

4' - 0"

TO

W

A

LL

M O

U N

T 5'

CL

TYP.

PNT-13

RWB-7 TYP.

6'

0"

AF

F.

1'

0"

44' - 0" EQ.

TYP.

TYP.

TYP.

4' - 0"

PNT-13PNT-13

EQ. EQ.

CL

PNT-11

TYP.

20' - 0" EQ.EQ.

AF

F.

1'

0" 6'

0"

8 8

DRINKING FOUNTAIN W/

WATER BOTTLE FILL - CF/CI.

RWB-7

TYP.

4' - 0"

TYPICAL CASEWORK:

- FACE AND SIDE FINISH OF BASE AND UPPER

CABINETRY: PLAM-1

- INTERIOR FINISH: WHITE MELAMINE

- IF OPEN SHELF, INTERIOR FINISH SHALL BE

PLAM-1

- COUNTERTOP & 4"H SPLASH: PLAM-2

- HARDWARE PULLS: ADA COMPLIANT, 4" BAR

PULL, BRUSHED NICKEL FINISH

TYPICAL CASEWORK W/ SINK @ BASE CABINET:

- FACE AND SIDE FINISH OF BASE AND UPPER

CABINETRY: PLAM-1

- INTERIOR FINISH: WHITE MELAMINE

- COUNTERTOP & 4"H SPLASH: SSM-1

- HARDWARE PULLS: ADA COMPLIANT, 4" BAR

PULL, BRUSHED NICKEL FINISH

CASEWORK @ MEDIA CENTER MAKER'S SPACE:

- FACE AND SIDE FINISH OF BASE AND UPPER

CABINETRY: PLAM-7

- INTERIOR FINISH: WHITE MELAMINE

- COUNTERTOP & 18"H BACK-SPLASH: SSM-5

- HARDWARE PULLS: ADA COMPLIANT, 4" BAR

PULL, BRUSHED NICKEL FINISH

CASEWORK @ MEDIA CENTER KIOSK:

- FACE AND SIDE FINISH OF BASE CABINETRY:

PLAM-7

- INTERIOR FINISH: WHITE MELAMINE

- COUNTERTOP & 4"H BACK-SPLASH: SSM-3

- HARDWARE PULLS: ADA COMPLIANT, 4" BAR

PULL, BRUSHED NICKEL FINISH

CASEWORK @ SCIENCE ROOMS:

- FACE & SIDE FINISH OF UPPER CABINETRY:

PLAM-7

- FACE AND SIDE FINISH OF BASE CABINETRY:

PLAM-6

- INTERIOR FINISH: WHITE MELAMINE

- COUNTERTOP & 4"H SPLASH: SSM-6

- HARDWARE PULLS: ADA COMPLIANT, 4" BAR

PULL, BRUSHED NICKEL FINISH

CLASSROOM STORAGE TOWER CASEWORK:

- FACE AND SIDE FINISH:PLAM-8

- INTERIOR FINISH: WHITE MELAMINE

- HARDWARE PULLS: ADA COMPLIANT, 8" BAR

PULL, BRUSHED NICKEL FINISH

Z-CLIP MOUNTED GYM WALL PADDING - REFER TO

ARCH. SPECS FOR FULL DETAILS

Z-CLIP MOUNTED FULL LENGTH FITNESS MIRRORS

- TEMPERED GLASS W/ STAINLESS STEEL U-

CHANNEL EDGE @ TOP & BOTTOM (TYP.)

MILLWORK TEACHNG WALL - ALL EXPOSED

FACES SHALL BE COVERED WITH VNR-1.

ACCENT COLOR @ PAINTED GYP. BULKHEAD IN

EXTENDED LEARNING AREA, AS WELL AS ABOVE

LOCKERS IN THE CORRIDOR;

VARIES PER FLOOR :

PNT - 4 @ LEVEL 1

PNT - 5 @ LEVEL 2

PNT - 6 @ LEVEL 3

CORRIDOR WINDOW MILLWORK SURROUND: ALL

PANELS SHALL BE FINISHED IN WOOD VENEER;

VNR-1 (REFER TO MATERIALS SCHEDULE &

ASSOCIATED ARCHITECTURAL SPECIFICATION).

3 ACCENT PANELS SHALL BE INSTALLED PER

LEVEL AS INDICATED:

GREEN (PNT-4) LAQUERED PANEL @ L1

BLUE (PNT-5) LAQUERED PANEL @ L2

ORANGE (PNT-6) LAQUERED PANEL @ L3

1/4" LAMINATED GLASS (BUTT GLAZED) IN HM

FRAME (PNT-19), TYP. @ EXTENDED LEARNING.

1" INSULATED GLAZING IN AL. STOREFRONT

SYSTEM

CONSTRUCTION KEYNOTES

A. PROVIDE FILLER PANELS AS REQUIRED AT

CASEWORK & MILLWORK INSTALLATION LOCATIONS -

TYP. SPECIFICALLY AT LOCATIONS WHERE CASEWORK

IS ADJACENT TO WALL - PROVIDE FILLER PANELS FOR

EASE OF OPENING & CLOSING CASEWORK DOORS &

DRAWERS.

B. ALL END PANELS SHALL BE FINISHED TO MATCH

ADJACENT CABINETRY / CASEWORK.

C. PORCELAIN WALL TILE SHALL ALWAYS BEGIN WITH

THE FULL TILE AT THE TOP OF THE ELEVATION,

ADJACENT TO THE CEILING. THE CUT TILE SHALL

ALWAYS BE AT THE BASE, ADJACENT TO THE FLOOR

SURFACE, UNO.

D. PROVIDE REGULAR CMU BEHIND FLUSH MOUNT

FIXTURES AND DEVICES AT LOCATIONS WHERE SPLIT

FACE CMU IS CALLED OUT.

E. WALLS SHALL BE PAINTED PNT-1; UNO.

F. WALL BASE SHALL BE RWB-1; UNO.

G. COVE TILE BASE @ LOCKER ROOM(S) TO EXTEND AT

LOCKER BASE, TYP.

H. PROVIDE FILLER PANELS AS REQUIRED @ END(S) OF

LOCKER RUN; TYP.

I. PARGE ALL CMU WALLS AT PORCELAIN TILE

INSTALLATION LOCATIONS, AS REQUIRED, FOR A

SMOOTH AND CONSISTENT SUBSTRATE.

GENERAL CONSTRUCTION

NOTES

ACOUSTIC WALL PANEL KEY

# 1 - 1" WOOD FIBER ACOUSTIC WALL PANELS ON 3-5/8"

MTL STUD AT 16" OC WITH ACOUSTICAL INSULATION

(GYM)

# 2 - 2" THICK FABRIC WRAPPED ACOUSTIC PANEL

CLIP MOUNTED

2A. HUNTER (APF-2)

2B. MOSS (APF-3)

2C. SPRUCE (APF-4)

2D. MIST (APF-5)

# 3 - 2" THICK FABRIC WRAPPED BUILT-UP PANEL

CLIP MOUNTED (1/2" PLYWOOD ON 2X WOOD

BLOCKING)

3A. HUNTER (APF-2)

3B. MOSS (APF-3)

# 4 - FABRIC WRAPPED ACOUSTIC DIFFUSER

4A. HUNTER (APF-2)

4B. MOSS (APF-3)

# 5 - 1" HEXAGON TECTUM ACOUSTIC PANELS (COMMONS)

CASEWORK LEGEND

BASIS OF DESIGN : ALL CASEWORK MODEL

NUMBERS DESIGNATED ON INTERIOR ELEVATIONS

ARE FROM CASE SYSTEMS 2014 PRODUCT

OFFERING CATALOG.

REFER TO MATERIAL LEGEND FOR FINISH

REQUIREMENTS.

REFER TO SPECIFICATIONS FOR ADDITIONAL

ACCEPTABLE MANUFACTURERS.

MODEL #:

WIDTH X HEIGHT X DEPTH

CONTINUOUS COUNTERTOP

SURFACE & 4"H SPLASH

MODEL #:

WIDTH X HEIGHT X DEPTH

PTW-6

TYP. @ SHOWER

STALL INTERIOR -

BACK & SIDE WALLS

FINISHING EDGE ACCESSORY:

SCHLUTER - JOLLY

FINISH: STAINLESS STEEL

TYP. @ ALL OUTSIDE CORNERS &

TILE EDGES ON WALLS.

SHOWER CURTAIN ROD - TYP.

AF

F.

6'

3"

OPEN OPEN

PTW-5

MB

8' - 0"

TYP. TYP.

CL

ALIGN

FINISHING EDGE ACCESSORY:

SCHLUTER - JOLLY

FINISH: STAINLESS STEEL

TYP. @ ALL OUTSIDE CORNERS &

TILE EDGES ON WALLS.

3' - 2 1/4" 3' - 2 1/4"

CL CL

WALL MOUNTED

HAND DRYER(S)

PTW-5

PTB-3

WALL MOUNTED

SOAP DISPENSER(S)

AF

F.

3'

4" 4'

0"

10' - 0" EQ.EQ.

WALL MOUNTED MIRROR -

TEMPERED GLASS

OPEN OPEN

5 1/4"5 1/4"

PNT-13

B1 A431

BENCH, TYP.

1'

6"

PNT-13

TYP.

PTB-3TYP.

6" 6'

0"

FILLER AS REQ'D. (TYP.)

ISSUE:

CHECKED:

SCALE:

Project #:

SHEET TITLE:

Final Plans for Bidding and Construction

H

G

F

E

D

C

B

A

H

G

F

E

D

C

B

A

DRAWN:

2338 COOLIDGE

SUITE 100

BERKLEY, MICHIGAN 48072

P 248.336.4700 F 248.336.4701

7654321

87654321

UNLESS NOTED OTHERWISE

C :\U se rs

\P ub lic \D oc um en ts

\L oc al _R ev it_

Fi le s\ st n_

_A rc hi te ct ur e_

PP

S_

N O

R

TH

M S

_s sg ro ss .rv t 3/

/2

9:

:2

A M

As indicated Checker

PORTAGE PUBLIC

SCHOOLS

NORTH MIDDLE SCHOOL

PORTAGE, MICHIGAN

INTERIOR ELEVATIONS

A402 214100247

Author

REFERENCED ON /A4 A111A 1/4" = 1'-0"A6

A149 EAST

REFERENCED ON /A4 A111A 1/4" = 1'-0"B6

A149 NORTH

REFERENCED ON /A4 A111A 1/4" = 1'-0"A1

A149 SOUTH

REFERENCED ON /A4 A111A 1/4" = 1'-0"B1

A149 WEST

REFERENCED ON /F3 A121 1/4" = 1'-0"D6

TOILET ROOM 144 - BF BENCH

REFERENCED ON /F3 A121 1/4" = 1'-0"E6

TOILET ROOM A137 - BF LOCKERS

REFERENCED ON /F3 A121 1/4" = 1'-0"G6

TOILET RM. A137 -SMALL LOCKERS

REFERENCED ON /F3 A121 1/4" = 1'-0"G4

AREA A - TOILET ROOM A144 - EAST - BF

LOCKERS

REFERENCED ON /F3 A121 1/4" = 1'-0"G3

TOILET ROOM A144 - EAST SMALL BF

LOCKERS

REFERENCED ON /F3 A121 1/4" = 1'-0"G2

AREA A - TOILET ROOM A144 - WEST - BF

LOCKERS

REFERENCED ON /A4 A111A 1/4" = 1'-0"D4

A123 EAST

REFERENCED ON /A4 A111A 1/4" = 1'-0"D1

A123 NORTH

REFERENCED ON /A4 A111A 1/4" = 1'-0"E1

A123 SOUTH

REFERENCED ON /A4 A111A 1/4" = 1'-0"E4

A123 WEST

REFERENCED ON /F3 A121 1/4" = 1'-0"H6

LOCKER RM SHOWER

REFERENCED ON /F3 A121 1/4" = 1'-0"H4

LOCKER RM. SHARED WALL

REFERENCED ON /F3 A121 1/4" = 1'-0"H3

LOCKER RM. SHARED WALL - SINK

2017.03.24 CONSTRUCTION2017.03.24 CONSTRUCTION

REFERENCED ON /F3 A121 1/4" = 1'-0"H1

AREA A - TYPICAL LOCKER ROOM ELEVATION

https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176591 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176703 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176591 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176591

DS1147

Rectangle

File details come from the government source that posted it. Updated .