Attachment 10 - A112A_ SECOND LEVEL FLOOR PLAN - AREA A.pdf
PDF 638 KB Posted
- Solicitation number
- RFP PPS 210000001576 1
- Issued by
- Kalamazoo County, Michigan
About this file
This is an architectural floor plan document for Portage Public Schools' North Middle School project in Portage, Michigan. The drawing depicts the second level floor plan for Area A at a scale of 1/8" = 1'-0" and includes detailed layouts of multiple instructional and support spaces. The plan shows the locations of classrooms, collaborative spaces, a gymnasium with folding basketball backstops, a media center, a maker space, locker rooms, storage areas, an IDF (Intermediate Distribution Frame), and mechanical spaces. The floor plan incorporates dimensions from column reference lines to partition faces, specifications for wall-mounted equipment including marker boards and television monitors, and references to related construction drawings for fire-rated assemblies, partition types, and mounting heights. The document includes comprehensive construction keynotes detailing 24 specific features such as display case systems, automatic door openers, fire extinguisher cabinets, water coolers, basketball backstop hoists, bleacher systems, lockers, and scoreboard installations.
The document provides general floor plan notes and roof plan specifications with detailed technical requirements for construction. Roof plan notes address equipment coordination with MEP (Mechanical, Electrical, and Plumbing) drawings, walkway pad specifications around roof equipment, pipe clearance requirements, tapered insulation installation, and reference to flashing and assembly details. The drawing was finalized for bidding and construction with multiple revision dates tracked from March 2017 through April 2019. All partitions default to Type K8 (masonry) or Type C3 (gypsum) unless otherwise noted, with specific requirements for stainless steel corner guards at floor level and fire-rated construction around shaft enclosures. The document references additional drawings including G021 for mounting heights, A421 for partition types, A357 for roof details, A341 for roof assembly types, and A115B for typical roof details.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A403 A5
COMMUNITY ROOM
A209
STO
A210
WORK RM
A211
OFFICE
A208
COLLAB
A207
COLLAB
A201
COLLAB
A200
COLLAB
A203
IDF
A217
ELEC
A218
MAKER SPACE
A205
GYMNASIUM
A220
STORAGE
A226
W O
M
EN
'S T
R A2
STAIR
S4
STAIR
S5
MEN'S TR
A212
STORAGE
A204
OFFICE / CONC
A219
OPEN TO BELOW
OPEN TO BELOW
DOWN
MEDIA CENTER
A206
COLLAB
A202
A201
A200
A202
A208
A207
A209
A219
S5S4
A209B
A410G6
A304A6
A302
F5
C6
C6
MB
8' - 0"
C6
TVC6
C6
MB
8' - 0" MB
6' - 0"
TV
C6
C6
C6
C6
C6
MB
6' - 0"
TV
MB
8' - 0"
1K12
A4 A123
D5 A122
L4 L4
MB
8' - 0"
D5
A411 G4
A409A6
A2
A409
C2
C6
A409 E2
A409 F2
H6
E6 A409F4 F6
E7 A451
COMPUTER
KIOSKS
A4 A121
3.4
0.5
0.1
3.9
K
J
J
H
H G
F.9
F.9 F.4 F E.4 E D.6 D C.5 C
B
A
A409
H4A6 A442
A226
A218 A217
A222
S2D
A204
A210
A211
A211B
A216
A403
F2
7'
7/
8"
SHAFT
SH1
R E:
A1 1 2
B
RE: A112B
RE: A112C
R E:
A1 1 2
C
A409
H2
SHAFT
SH6
SHAFT
SH7
6' - 4" M.O.
6' - 0"
1' - 4"
M.O.
6' - 0"49' - 8"
12' - 0" 3' - 10 1/2"
4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4"
2'
5/
8"
R .O
4'
0" 4'
0"
4'
0" 4'
0"
4'
0" 4'
0"
4'
0" 4'
0"
4'
0" 4'
0"
4'
0" 4'
0"
R .O
1'
8"
38' - 8" M.O.
11' - 4" 60' - 0"
A219B
R.O.
20' - 0"
R.O.
56' - 0"
4' - 0"
39' - 4"
STAIR
S2
C3 A363
A5 A363
C5 A363
F5 A363
F1 A364 F3
A364
F5 A364
C1 A364
C3 A364
A3 A364
C5 A364
A5 A364
A1 A364
A410
A3
D3
A219C
F6
1'
4"
F6 A365
41' - 8" 30' - 0" 41' - 8"
7'
1/
2"
1' - 2" 1' - 2"
113' - 4"
1'
2"
4' - 1 1/2"
A203
18' - 4 1/2"
10 10
15' - 0" 6' - 4" 10' - 7 1/2"
2'
0"
CLR
1' - 6"
2'
8"
15' - 4 1/8" 4' - 0"
3 3
3' - 4"7' - 4"3' - 4"4' - 0"3' - 4"6' - 0"3' - 4"
10' - 0"5' - 4"
1' - 0"
ROOF OVERHANG
ABOVE
RS-1
(FULLY TAPPERED)
RS-1
(FULLY TAPPERED)
RD OFD
RD
OFD
B.1
2.8
2.9
CORRIDOR
A216
R.O.
45' - 1 1/2"
1' - 1 5/8"
2' - 5 1/2"
4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 2' - 8"
1'
4" 4'
2"
1'
2"
A2 A443
4'
0"
7' - 3 7/8"
10' - 2"13' - 11 5/8"9' - 8 3/8"11' - 9 5/8"14' - 8"9' - 4"9' - 3 13/16"14' - 8 3/16"10' - 10 15/16"11' - 5 7/16"
1' - 1 1/2"
23' - 10 1/8"23' - 10"
13' - 9 1/2"
12' - 8"
38' - 0"10' - 4"
O .C
O
.C
1"
O .C
0" 8'
8"
B3
14' - 4 3/8" 10' - 0"
B6
6"
4' - 0"
RS-1
0"
J.2
0.4
B3
1 5/8"
10 10
11 11
1'
8"
1/ 2"
A1 A605
A1 A605
4'
1'
4"
1' - 6" CLEAR
2' - 0"
9' - 7 5/8"
8' - 0" 1' - 4"
9'
0"
/8
A6 A362
A4 A510
F.8
STORAGE
A222
SHAFT
SH2
F26
D2 A441
F3
MB
8' - 0"
MB
8' - 0"
MB
8' - 0"
MB
8' - 0"
MB
6' - 0"
C6
FO
R
W
AR
D
FO
LD
IN
G
BA
C
KB
O
AR
D
FO
R
W
AR
D
FO
LD
IN
G
BA
C
KB
O
AR
D
FORWARD
FOLDING
BACKBOARD
FORWARD
FOLDING
BACKBOARD
SIDE FOLDING
BACKBOARD
SIDE FOLDING
BACKBOARD
2"
EQ. EQ.
10"
SLOPE
1/4" / FT
C.2 2' - 6"
5'
4"
2' - 6"
2"
11 5/8"
3' - 4" 11' - 4"
3' - 1 1/4"
2"
13' - 2" 8' - 11 5/8" 8' - 0" 13' - 2"
J4
K4
1J12
1J12
1K8
1K81K8
J12
J12
K12
1J8
1K8
J8
A206
1J12
1K8
1K8
K4 J12
J8J8
3'
0"
J8
A205
J12
A220BA220
1K8
1K8
1K8 1K8
1K8
1K8
1J12
1K8
1K8
1K8
J12 J8 J8J8
A412
A4
0.45
J8 J8
J8J8
24 24
MIN 3'
- 6
7'
5"
2' - 6" MB
BOARD LEGEND
PROVIDE MAGNITIZED MARKER BOARD WITH
MATTE FINISH UNLESS OTHERWISE NOTED,
SIZED AS INDICATED. DIMENSIONS SHOWN
ARE FROM EDGE OF WALL OPENING TO
CENTERLINE OF BOARD . RE:G021 FOR
MOUNTING HEIGHT, ELECT FOR POWER
AND TECHNOLOGY FOR EQUIPMENT
TV
PROVIDE MOUNTED TELEVISION MONITOR
TECHNOLOGY, 70" UNO. LOCATED AS
DIMENSIONED RE:G021 FOR MOUNTING
HEIGHT, ELECT FOR POWER AND
TECHNOLOGY FOR EQUIPMENT
ROOF LEGEND
SLOPE DIRECTION
CREATED BY STRUCTURE
TAPERED INSULATION
ROOF DRAIN (RD)
OVERFLOW
DRAIN (OFD)
SLOPE DIRECTION
CREATED BY TAPERED
INSULATION
ROOF MEMBRANE
WALKWAY PAD
SLOPE
1/4" / FT
AREA A
AREA B
AREA C
N
ISSUE:
CHECKED:
SCALE:
Project #:
SHEET TITLE:
KEY PLAN (NTS)
Final Plans for Bidding and Construction
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
DRAWN:
2338 COOLIDGE
SUITE 100
BERKLEY, MICHIGAN 48072
P 248.336.4700 F 248.336.4701
7654321
87654321
UNLESS NOTED OTHERWISE
C:
\U se rs
\P ub lic \D oc um en ts
\L oc al _R ev it_
Fi le s\ st n_
_A rc hi te ct ur e_
PP
S_
NO
RT
H M
S
_S ea nS G ro ss
.rv t
4/
/2
8:
:4
AM
As indicated Checker
PORTAGE PUBLIC
SCHOOLS
NORTH MIDDLE SCHOOL
PORTAGE, MICHIGAN
SECOND LEVEL FLOOR
PLAN - AREA A
A112A 214100247
Author
FLOOR PLAN GENERAL NOTES
1 ALL DIMENSIONS ARE FROM COLUMN REFERENCE LINE
TO FACE OF PARTITION, UNLESS NOTED OTHERWISE.
2 REFER TO CODE DRAWINGS (G0 SERIES) FOR LOCATIONS
AND EXTENTS OF FIRE RATED ASSEMBLIES. IF PARTITION
DISCREPENCY OCCURS BETWEEN CODE PLANS AND
FLOOR PLANS, PROVIDE THE PARTITION TYPE INDICATED
WITH THE MOST STRINGENT REQUIREMENTS.
3 REFER TO DRAWING G021 FOR TYPICAL MOUNTING
HEIGHTS.
4 REFER TO DRAWING A421 FOR ALL INTERIOR PARTITION
TYPES.
5 ALL MASONARY PARTITIONS ARE TYPE "K8" UNLESS
NOTED OTHERWISE.
6 ALL GYPSUM PARTITIONS ARE TYPE "C3" UNLESS NOTED
OTHERWISE.
7 ALL HOUSE KEEPING PADS INDICATED ARE FOR
REFERENCE ONLY, COORDINATE ACTUAL SIZE AND
LOCATION WITH APPROVED MECHANICAL AND PLUMBING
SHOP DRAWINGS.
8 FIRST FLOOR REFERENCE ELEVATION 100'-0" = 902.00'
DATUM ON CIVIL DRAWINGS.
9 PROVIDE STAINLESS STEEL CORNER GUARDS AT ALL
GYP.BD. OUTSIDE CORNERS AT FLOOR LEVEL
10 PROVIDE FIRE RATED CONSTRUCTION AROUND ALL
SHAFT ENCLOSURES.
1/8" = 1'-0"A4 SECOND LEVEL FLOOR PLAN - AREA A
CONSTRUCTION KEYNOTES
1 ALUM. DISPLAY CASE SYSTEM
2 WALL MOUNTED BARRIER FREE AUTOMATIC DOOR
OPENER ACTUATOR SWITCH
3 SEMI-RECESSED FIRE EXTINGUISHER CABINET
4 ELECTRIC WATER COOLER WITH BOTTLE FILL STATION,
RE: PLUMBING DRAWINGS
5 OWNER PROVIDED, CONTRACTOR INSTALLED ARCHERY
CURTAIN AND TRACK
6 OPERABLE WALL PARTITION AND TRACK
7 WALL MOUNTED RECESSED KNOX BOX
8 ROOF ACCESS LADDER, RE: DETAILS ON A357
9 TOP ROLLING GYM DIVIDER CURTAIN
10 CEILING SUPPORTED FOLDING BASKETBALL BACKSTOP,
TYP.
11 TELESCOPING BLEACHER SYSTEM
12 CORRIDOR METAL LOCKERS, RE: INTERIOR ELEVATIONS
FOR TYPE AND CONFIGURATION
13 CONFIRM ELEVATOR ROUGH OPENING REQUIREMENTS
WITH APPROVED ELEVATOR SHOP DRAWINGS
14 ELECTRONIC SCOREBOARD
15 6" DIA. CONC. FILLED STEEL BOLLARD
16 4" HIGH CONC. HOUSE KEEPING PAD TYP. 6" HIGH CONC
HOUSE KEEPING PAD AT AHU'S, RE: STRUCTURAL AND
MECHANICAL DRAWINGS
17 4" HIGH CONC. CURB AROUND PERIMETER OF SPACE
AND ALL FLOOR PENETRATIONS.
18 GALV. STEEL BAR GRATING PLATFORM AND STEPS, RE:
DETAILS ON A357
19 PRE-FINISHED METAL GATE WITH LATCHING HARDWARE
20 WRESTLING MAT HOIST
21 PROVIDE 20'x20' NEOPRENE MEMBRANE OVER ROOF
MEMBRANE AT KITCHEN EXHAUST HOODS, ADHERE
AND FLASH NEOPRENE TO ROOF MEMBRANE PER ROOF
MANUF RECOMENDATIONS.
22 LOCKER ADA BENCH - WALL MOUNTED;
20" MIN. DEPTH
23 LOCKER ROOM FREESTANDING BENCH
24 STOP MASONRY AT FIRST FULL COURSE BELOW JOISTS.
FINISH WALL WITH DRYWALL TO DECK. MAINTAIN ANY
ACOUSTICAL, FIRE, AND SMOKE RATINGS AS REQUIRED.
ROOF PLAN GENERAL NOTES
1 REFER TO MEP DRAWINGS FOR ROOF TOP
EQUIPMENT NOT SHOWN. MEP EQUIPMENT
DEPICTED ON THIS DRAWING IS FOR GENERAL
ARCHITECTURAL INFORMATION ONLY. REFER TO
MEP DRAWINGS FOR ADDITIONAL REQUIREMENTS
AND COORDINATION. REFER TO STRUCTURAL
DOCUMENTS FOR EQUIPMENT SUPPORTS.
2 PROVIDE WALKWAY PADS AT PIPE SUPPORT
LOCATIONS. REFER TO MEP DRAWINGS FOR PIPE
SUPPORT LOCATIONS AND TYPE. PAD SHALL BE
MINIMUM 2" WIDER THAN SUPPORT IN ALL
DIRECTIONS.
3 PROVIDE MANUFACTURER STANDARD WALKWAY
PADS AS INDICATED AND AT SERVICE SIDE OF ALL
MECHANICAL EQUIPMENT, WITH 2" SEPARATIONS
BETWEEN PADS - REFER TO MEP DRAWINGS FOR
NUMBER AND LOCATION OF ROOF TOP MECHANICAL
EQUIPMENT. PROVIDE MFR STANDARD WALKWAY
PADS AT TOP AND BOTTOM OF ALL ACCESS
LADDERS.
4 VENT STACKS AND OTHER PIPES REQUIRE A
MINIMUM 12" CLEARANCE ON ALL SIDES FROM
WALLS, CURBS, AND OTHER PROJECTIONS TO
FACILITATE PROPER FLASHING.
5 PROVIDE TWO WAY TAPERED INSULATION CRICKETS
AT HIGH SIDE OF ALL ROOF CURBS WIDER THAN 4'-0".
6 REFER TO DRAWING A341 FOR ROOF ASSEMBLY
TYPES AND FLASHING PROFILES.
7 REFER TO DRAWING A115B FOR TYPICAL ROOF
DETAILS.
2017.03.24 CONSTRUCTION
2017.06.12 PR 01
2017.08.11 PR 03
2018.06.14 PR 11
2018.10.16 PR 13
2018.12.07 PR 15
2019.04.05 PR 17
2017.03.24 CONSTRUCTION
2017.06.12 PR 01
2017.08.11 PR 03
2018.06.14 PR 11
2018.10.16 PR 13
2018.12.07 PR 15
2019.04.05 PR 17
https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176647 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/25207746 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/27858387 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/42645892 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176347 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/21254075 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/21254075 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176659 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176659 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176659 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176659 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176659 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176659 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176659 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176659 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176659 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176558 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/26723031 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176531 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/25207748 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/27858372 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/27858372 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/27858372 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/27858372 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/68442159 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/68442154 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176605 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176605 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176609 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176609 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176609 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176609 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176609 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176609 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176609 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/22381345 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/22381345 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/27858400 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176529 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176529 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/24022160 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176714 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176379 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176379 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176482 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176482 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176553 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176519 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176519 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176710 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/24022173 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/68442156 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176367 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176367 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/18176409 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/21194854 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/21194854 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/68442162 https://app.procore.com/160826/project/drawing_areas/147741/drawing_log/68442162
File details come from the government source that posted it. Updated .