This document contains a Failure Modes and Effects Criticality Analysis (FMECA) for a media converter module used in an Integrated Battle Command System (IBCS). The FMECA identifies 10 potential failure modes for the media converter and its components. These include failures of the internal power supply such as an open or short input, failures of fiber and Ethernet connectors, and failures of the processor or power connectors. Each failure mode is assessed for its effects on the media converter, IBCS relay, and overall system functionality. Though initially categorized as severity level I, the failures are reduced to severity level III-1R given the redundant design of the IBCS relays. The calculated failure rate before and after this reduction is also shown.

The related federal contract opportunity posting is a draft RFP for IBCS low rate initial production and full rate production. It seeks hardware production along with software/firmware updates and engineering changes. The Army Materiel Command Contracting Command at Redstone Arsenal is listed as the issuing agency. As this is a draft, the government is not currently accepting proposals in response. No further contracting details are provided in the posting.

View the file

Other files for this federal contract opportunity

Other files attached to DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
Attachment 21 - Task Order 0001 Statement of Work.docx DOCX document
Attachment 10c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 10a.16– R034 Media Converter Power Supply-FMECA.xlsx XLSX spreadsheet
W31P4Q-20-R-0015_DRAFT_28 May 2020.pdf PDF
Attachment 10a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 04b - Draft_Relay Acceptance Test Procedures.docx DOCX document
Attachment 13c - IBCS-A301-003 Vol II Instructor Guide.pdf PDF
Attachment 22a.1.f - EOC Shelter views.pptx PPTX presentation
Attachment 22a.1.d - ALH-213030 00 CABLE ASSEMBLY, CASS J1 AND J3.pdf PDF
Attachment 20 - Section M - Evaluation Factors For Award.docx DOCX document
Attachment 22a - CASS to PDRS.docx DOCX document
Attachment 10d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10e.10 – E148 – Table 4 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10e.5 – E122 – EMI Tent PDU-FMECA.xlsx XLSX spreadsheet
Attachment 17 - Pre-Award Survey Accounting System Checklist.pdf PDF
Attachment 22a.1.g - PL-ALH-209032 00 CABLE ASSEMBLY CASS ETHERNET.pdf PDF
Attachment 22a.1.e - ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 22a.4 - CASS Task Purpose.pptx PPTX presentation
Attachment 10a.15 – R033 Media Converter Module 12-FMECA.xlsx XLSX spreadsheet
Attachment 10c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 03 - GFP Attachment - LRIP_FRP - 20 April 2020.xlsx XLSX spreadsheet
Attachment 10d.8 – E153 RS112 Server -07 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 15a- Example Skill Classification Crosswalk.xlsx XLSX spreadsheet
Attachment 16 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 10a.11 – R029 PFPU SSHD-1—FMECA.xlsx XLSX spreadsheet
Attachment 10c.2 – E044 Firewall Black-FMECA.xlsx XLSX spreadsheet
Attachment 13d - IBCS-A301-003 Vol III Program of Instruction.pdf PDF
Attachment 10g - IBCS - 243-003 HW FMECA Results.pdf PDF
Attachment 10d.9 – E156 UPS-FMECA.xlsx XLSX spreadsheet
Attachment 10d.6 – E153 RS112 Server -05 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10b.10 – E034 R112 Shelter – Server Stack – 04-FMECA.xlsx XLSX spreadsheet
Attachment 10e.1 – E067 – EtherNet Switch-FMECA.xlsx XLSX spreadsheet
Attachment 10d.4 – E151 – Media Converter 04-FMECA.xlsx XLSX spreadsheet
Attachment 10c.3 – E048 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 10b.7 – E031 R112 Shelter – Server Stack – 01-FEMCA.xlsx XLSX spreadsheet
Attachment 22a.3 - S280_SystemPowerAnalysis_Draft_12-5-2017.xlsx XLSX spreadsheet
Attachment 10c.16 – E069 Media Converter 03 - FMECA.xlsx XLSX spreadsheet
Attachment 10b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 13a -A293-004 ETM 60 Percent Draft.pdf PDF
Attachment 10d.10 – E157 KVM Switch 2 Shelter-FMECA.xlsx XLSX spreadsheet
Attachment 10c.12 – E062 Shelter Router-Red-FMECA.xlsx XLSX spreadsheet
Attachment 14 - Technical Library.docx DOCX document
Attachment 10e.2 – E082 thru E091 Wkstn Laptop-FMECA.xlsx XLSX spreadsheet
Attachment 10c.14 – E064 Shelter Router Black – FMECA.xlsx XLSX spreadsheet
Attachment 10c.9 – E059 Shelter Switch – 01-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.i - PL-ALH-213030 00 CABLE ASSEMBLY, CASS J1 AND J3.pdf PDF
Attachment 10a.8 – R008 Media Converter Chassis-FMECA.xlsx XLSX spreadsheet
Attachment 10e.6 – E143 – ICE UPS-FMECA.xlsx XLSX spreadsheet
Attachment 07 - AIAMD Requirements Prioritization 1-n table.docx DOCX document
Attachment 10a.2 – R002 BPU-FMECAAttachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Show all 50

DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pivot Table 32

R032-Media Converter Module #11
Row LabelsSum of CmCount of Failure Mode Description
Internal Failure2.15E-052Fiber Connector Port Fails20.2
Fiber Connector Port Fails2.15E-052Power Supply input (Short)10.1
Ethernet Connector Port (Open)2.15E-052Power Supply Input (Open)10.1
Power Supply Input (Open)5.37E-061Internal Failure20.2
Power Supply input (Short)5.37E-061Ethernet Connector Port (Open)20.2
Power connector fails (Open)5.37E-061Power connector fails (Open)10.1
Power connector fails (Short)5.37E-061Power connector fails (Short)10.1
Grand Total8.60E-0510101

Prelim Analsis 32

PRELIMINARY ANALYSIS:Parent LRU:R032-Media Converter Module #11
10/100TX to 100 FX Media Converter Module
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =8.60E-05
Failure ModesCount of
Failure ModesSeverity
ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Fiber Connector Port Fails220.00%Category I10Internal Failure2.15E-052
Internal Failure220.00%Fiber Connector Port Fails2Fiber Connector Port Fails2.15E-052
Ethernet Connector Port (Open)220.00%Internal Failure2Ethernet Connector Port (Open)2.15E-052
Power Supply input (Short)110.00%Power connector fails (Open)1Power Supply Input (Open)5.37E-061
Power Supply Input (Open)110.00%Power connector fails (Short)1Power Supply input (Short)5.37E-061
Power connector fails (Open)110.00%Power Supply Input (Open)1Power connector fails (Open)5.37E-061
Power connector fails (Short)110.00%Power Supply input (Short)1Power connector fails (Short)5.37E-061
Grand Total:10Ethernet Connector Port (Open)2Grand Total8.60E-0510
Grand Total10

32 Cat I and II

Parent LRU:R032-Media Converter Module #11
Mission Phase-Operational Mode:All Phases
FPMH:1.629
t:72hr
Cr = ∑Cm =1.88E-04
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R
Failure Effect atFailure Detection MethodCompemsating Provisions
ID#ComponentFunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
1275Media Converter internal power supplyReceives 5VDC input power and provides power to the internal Media Converter circuitsPower Supply Input (Open)Hardware FailureNo power to the Relay Media Converter module (1A22)Loss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AVI-630-30 (Relay Media Converter Module #11 Power Fault)TBDCategory IRelays are RedundantCategory III-1R1.000.050.10001.63E-061.17E-055.87E-07
1276Media Converter internal power supplyReceives 5VDC input power and provides power to the internal Media Converter circuitsPower Supply input (Short)Hardware FailureNo power to the Relay Media Converter Modules (1A22 & 1A23)Loss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AVI-630-20 (Relay Media Converter Power Supply Indicator Fault)TBDCategory IRelays are RedundantCategory III-1R1.000.050.10001.63E-061.17E-055.87E-07
1277Media Converter internal power supplyReceives 5VDC input power and provides power to the internal Media Converter circuitsInternal FailureHardware FailureNo power to the Relay Media ConverterLoss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AVI-630-30 (Relay Media Converter Module #11 Power Fault)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.63E-062.35E-051.17E-06
1278Media Converter ProcessorPerforms Media Converter Processing functionsInternal FailureHardware FailureLoss of all Media Converter (1A22) functionsLoss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.63E-062.35E-051.17E-06
1279Power connectorReceives 5VDC input power from the IFCN Relay Media Converter Power SupplyPower connector fails (Open)Hardware FailureNo power to the Relay Media Converter module (1A22)Loss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AVI-630-30 (Relay Media Converter Module #11 Power Fault)TBDCategory IRelays are RedundantCategory III-1R1.000.050.10001.63E-061.17E-055.87E-07
1280Power connectorReceives 5VDC input power from the IFCN Relay Media Converter Power SupplyPower connector fails (Short)Hardware FailureNo power to the Relay Media Converter Modules (1A22 & 1A23)Loss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AVI-630-20 (Relay Media Converter Power Supply Indicator Fault)TBDCategory IRelays are RedundantCategory III-1R1.000.050.10001.63E-061.17E-055.87E-07
1281FE connectorEthernet interface to the Relay Black Router LRUEthernet Connector Port (Open)Hardware FailureLoss of the Ethernet interface to the Relay Black RouterLoss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.63E-062.35E-051.17E-06
1282FE connectorEthernet interface to the Relay Black Router LRUEthernet Connector Port (Open)Hardware FailureLoss of the Ethernet interface to the Relay Black RouterLoss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.63E-062.35E-051.17E-06
1283Rx connectorFiber interface (Receive data) to the EOC Shelter Media ConverterFiber Connector Port FailsHardware FailureLoss of the Fiber "Receive data" interface to the EOC Shelter Alternate MediaLoss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.63E-062.35E-051.17E-06
1284Tx connectorFiber interface (Transmit data) to the EOC Shelter Media ConverterFiber Connector Port FailsHardware FailureLoss of the Fiber "Transmit data" interface to the EOC Shelter Alternate MediaLoss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.63E-062.35E-051.17E-06

Data 32

Parent LRU:R032-Media Converter Module #11
Mission Phase-Operational Mode:All Phases
FPMH:0.746
t:72hr
Cr = ∑Cm =8.60E-05
Modified Cr =4.30E-06
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R
Failure Effect atFailure Detection MethodCompemsating Provisions
ID#ComponentFunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
1275Media Converter internal power supplyReceives 5VDC input power and provides power to the internal Media Converter circuitsPower Supply Input (Open)Hardware FailureNo power to the Relay Media Converter module (1A22)Loss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AVI-630-30 (Relay Media Converter Module #11 Power Fault)TBDCategory IRelays are RedundantCategory III-1R1.000.050.10007.46E-075.37E-062.69E-07
1276Media Converter internal power supplyReceives 5VDC input power and provides power to the internal Media Converter circuitsPower Supply input (Short)Hardware FailureNo power to the Relay Media Converter Modules (1A22 & 1A23)Loss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AVI-630-20 (Relay Media Converter Power Supply Indicator Fault)TBDCategory IRelays are RedundantCategory III-1R1.000.050.10007.46E-075.37E-062.69E-07
1277Media Converter internal power supplyReceives 5VDC input power and provides power to the internal Media Converter circuitsInternal FailureHardware FailureNo power to the Relay Media ConverterLoss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AVI-630-30 (Relay Media Converter Module #11 Power Fault)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20007.46E-071.07E-055.37E-07
1278Media Converter ProcessorPerforms Media Converter Processing functionsInternal FailureHardware FailureLoss of all Media Converter (1A22) functionsLoss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.20007.46E-071.07E-055.37E-07
1279Power connectorReceives 5VDC input power from the IFCN Relay Media Converter Power SupplyPower connector fails (Open)Hardware FailureNo power to the Relay Media Converter module (1A22)Loss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AVI-630-30 (Relay Media Converter Module #11 Power Fault)TBDCategory IRelays are RedundantCategory III-1R1.000.050.10007.46E-075.37E-062.69E-07
1280Power connectorReceives 5VDC input power from the IFCN Relay Media Converter Power SupplyPower connector fails (Short)Hardware FailureNo power to the Relay Media Converter Modules (1A22 & 1A23)Loss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AVI-630-20 (Relay Media Converter Power Supply Indicator Fault)TBDCategory IRelays are RedundantCategory III-1R1.000.050.10007.46E-075.37E-062.69E-07
1281FE connectorEthernet interface to the Relay Black Router LRUEthernet Connector Port (Open)Hardware FailureLoss of the Ethernet interface to the Relay Black RouterLoss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.20007.46E-071.07E-055.37E-07
1282FE connectorEthernet interface to the Relay Black Router LRUEthernet Connector Port (Open)Hardware FailureLoss of the Ethernet interface to the Relay Black RouterLoss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.20007.46E-071.07E-055.37E-07
1283Rx connectorFiber interface (Receive data) to the EOC Shelter Media ConverterFiber Connector Port FailsHardware FailureLoss of the Fiber "Receive data" interface to the EOC Shelter Alternate MediaLoss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.20007.46E-071.07E-055.37E-07
1284Tx connectorFiber interface (Transmit data) to the EOC Shelter Media ConverterFiber Connector Port FailsHardware FailureLoss of the Fiber "Transmit data" interface to the EOC Shelter Alternate MediaLoss of the IFCN Relay Alternate Media interface functionLoss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection.N/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.20007.46E-071.07E-055.37E-07

File details come from the government source that posted it. Updated .