Attachment 1-Technical Capability Statements QE073.docx

DOCX document 25 KB Posted

Attached to
Weld, Gauge, and Vent Panels Federal contract opportunity
Solicitation number
N4215825QE073
Issued by
Department of the Navy Naval Sea Systems Command

About this file

This document is a Technical Capability Statement for Solicitation N4215825QE073, issued by the Department of the Navy Naval Sea Systems Command. The solicitation covers 18 specific panel types, including weld panels, drain manifolds, gauge panels, vent panels, and ball valve assemblies, all manufactured by Swagelok, Inc. and requiring SC11 cleaning specification. Each item has precise part numbers, specific cleaning requirements, and unique configurations such as globe valves, flare inlets/outlets, and specialized mounting specifications.

The solicitation is a single-source procurement, meaning only one responsible source (Dibert Valve) can provide these specialized panels. Vendors must complete the Technical Capability Statement by confirming compliance with all specifications, including a mercury-free clause, certificate of compliance, correct part number marking, and clear purchase order marking on shipping containers. No substitutes are allowed, and vendors must initial the certification page to be considered for award, with all pricing expected to include applicable shipping costs.

View the file

Other files for this federal contract opportunity

Other files attached to Weld, Gauge, and Vent Panels, newest first.
File Type Posted
RFQ N4215825QE073.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment (1) – Solicitation# N4215825QE073 Panels, Drain, Weld

Vendor shall certify that item quoted meets the capabilities, features and specifications listed below and that vendor can assume all contractor responsibilities stated below by initialing at the bottom. In order to be considered for award, this must be completed and submitted with the vendor quote.

TECHNICAL CAPABILITES STATEMENT

General Specifications for ITEMs 0001 through ITEM 0018

Shall be provided with the following capabilities, features and specifications:
Yes
No

ALL ITEMS MUST CONFIRM TO THE FOLLOWING DESCRIPTION AND

SPECIFICATIONS:

-MERCURY FREE CLAUSE INVOKED

-CERTIFICATE OF COMPLIANCE INVOKED

-VENDOR TO ENSURE THAT THE CORRECT P/N MARKED ON EACH ITEM

-VENDOR TO ENSURE THT THE PURCHASE ORDER NUMBER IS CLEARLY

MARKED ON THE EXTERIOR OF THE SHIPPING CONTAINER.

-NO SUBSTITUTES ALLOWED

ITEM 0001 QUANTITY: 1 EACH

PANEL

WELD PANEL FIGURE 1 (FIG. 1),

SC11 CLEANED,

SWAGELOK P/N DIBRT120308WELD1.1R1CLSC,

ITEM 0002 QUANTITY: 1 EACH

PANEL,

REV 2, SC11 CLEANED,

SWAGELOK P/N DIBRT-031020-FIG11

ITEM 0003 QUANTITY: 1 EACH

MANIFOLD

DRAIN MANIFOLD,

SC11 CLEANED,

MOD TO ASSEMBLY-33888,

SWAGELOK P/N ASSEMBLY-57323

ITEM 0004 QUANTITY: 1 EACH

PANEL,

SC11 CLEANED,

FIGURE 13,

SWAGELOK P/N DIBRT-031020-FIG13

ITEM 0005 QUANTITY: 1 EACH

PANEL,

SC11 CLEANED,

FIGURE 15,

SP MV MIDDLE TEE,

SWAGELOK P/N DIBRT-031020-FIG15

ITEM 0006 QUANTITY: 1 EACH

PANEL

BALL VALVE-TEE WELD ASSEMBLY, REV. 1,

SC11 CLEANED/NO LUBE ON BALL VALVE,

SWAGELOK P/N ASSEMBLY-55975

ITEM 0007 QUANTITY: 2 EACH

GAUGE PANEL FIG 8, REVISION 8,

SC11 CLEANED,

SWAGELOK P/N DIBRT-010615-FIG8

ITEM 0008 QUANTITY: 1 EACH

GAUGE PANEL FIG 8, REVISION 0,

SWAGELOK P/N DIBRT-031020-FIG8

ITEM 0009 QUANTITY: 1 EACH

CD-7 DRAIN PANEL,

SC11 CLEANED/DOW CORNING 4 LUBRICANT,

SWAGELOK P/N DIBRT-022120-FIG3.A,

ITEM 0010 QUANTITY: 2 EACH

GAUGE PANEL FIG 7,

SWAGELOK P/N DIBRT010615-FIG7 (REVISION 6)

ITEM 0011 QUANTITY: 2 EACH

CP-14/15 VENT PANEL,

SC11 CLEANED/DOW CORNING 4 LUBRICANT,

DRAWING REV 2,

SWAGELOK P/N DIBRT-010615-FIG13,

ITEM 0012 QUANTITY: 2 EACH

DRAIN MANIFOLD,

ASSEMBLY-18657 WITH SC11 CLEAN & NO VALVE LUBRICANT,

SWAGELOK P/N ASSEMBLY-33322

ITEM 0013 QUANTITY: 4 EACH

IXSP UPPER & LOWER TEE PANEL,

SC11 CLEANED, NON-WELDED,

DRAWING REV 2,

SWAGELOK P/N DIBRT-010615-FIG17,

ITEM 0014 QUANTITY: 2 EACH

PF SP LOWER PANEL, WELDED,

SWAGELOK P/N DIBRT-061520-FIG18,

ITEM 0015 QUANTITY: 2 EACH

MVSP MIDDLE TEE PANEL,

SC11 CLEANED/DOW CORNING 4 LUBE, NON-WELDED,

DRAWING REV 2,

SWAGELOK P/N DIBRT-010615-FIG18A,

ITEM 0016 QUANTITY: 2 EACH

BALL VALVE-TEE WELD ASSEMBLY, REV. 1,

SC11 CLEANED/NO LUBE ON BALL VALVE,

SWAGELOK P/N ASSEMBLY-55975

ITEM 0017 QUANTITY: 1 EACH

BOUNDARY PANEL,

WELDED, 1/4" MALE FLARE INLET,

1/2" MALE FLARE OUTLET, 1/2" SWAGELOK DRAINS,

SWAGELOK P/N DIBRT021808NNSYREV.ECLSC,

PURCHASED SC-11 CLEAN

ITEM 0018 QUANTITY: 2 EACH

S8G PANEL,

SC11 CLEANED,

3/8" GLOBE VALVE PANEL MOUNTED,

SWAGELOK P/N DIBRT-050820-FIG16

TECHNICAL CAPABILITY/CONTRACTOR RESPONSIBILITY CERTIFICATION

Vendor hereby certifies that vendor’s item meets or exceeds all specifications and contractor responsibilities stated in this solicitation, in their entirety, with no exceptions. __________ (initials)

DATE: _________________________________________

File details come from the government source that posted it. Updated .