Attachment 1-Technical Capability Statements QE073.docx
DOCX document 25 KB Posted
- Attached to
- Weld, Gauge, and Vent Panels Federal contract opportunity
- Solicitation number
- N4215825QE073
About this file
This document is a Technical Capability Statement for Solicitation N4215825QE073, issued by the Department of the Navy Naval Sea Systems Command. The solicitation covers 18 specific panel types, including weld panels, drain manifolds, gauge panels, vent panels, and ball valve assemblies, all manufactured by Swagelok, Inc. and requiring SC11 cleaning specification. Each item has precise part numbers, specific cleaning requirements, and unique configurations such as globe valves, flare inlets/outlets, and specialized mounting specifications.
The solicitation is a single-source procurement, meaning only one responsible source (Dibert Valve) can provide these specialized panels. Vendors must complete the Technical Capability Statement by confirming compliance with all specifications, including a mercury-free clause, certificate of compliance, correct part number marking, and clear purchase order marking on shipping containers. No substitutes are allowed, and vendors must initial the certification page to be considered for award, with all pricing expected to include applicable shipping costs.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFQ N4215825QE073.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment (1) – Solicitation# N4215825QE073 Panels, Drain, Weld
Vendor shall certify that item quoted meets the capabilities, features and specifications listed below and that vendor can assume all contractor responsibilities stated below by initialing at the bottom. In order to be considered for award, this must be completed and submitted with the vendor quote.
TECHNICAL CAPABILITES STATEMENT
General Specifications for ITEMs 0001 through ITEM 0018
| Shall be provided with the following capabilities, features and specifications: |
| Yes |
| No |
ALL ITEMS MUST CONFIRM TO THE FOLLOWING DESCRIPTION AND
SPECIFICATIONS:
-MERCURY FREE CLAUSE INVOKED
-CERTIFICATE OF COMPLIANCE INVOKED
-VENDOR TO ENSURE THAT THE CORRECT P/N MARKED ON EACH ITEM
-VENDOR TO ENSURE THT THE PURCHASE ORDER NUMBER IS CLEARLY
MARKED ON THE EXTERIOR OF THE SHIPPING CONTAINER.
-NO SUBSTITUTES ALLOWED
ITEM 0001 QUANTITY: 1 EACH
PANEL
WELD PANEL FIGURE 1 (FIG. 1),
SC11 CLEANED,
SWAGELOK P/N DIBRT120308WELD1.1R1CLSC,
ITEM 0002 QUANTITY: 1 EACH
PANEL,
REV 2, SC11 CLEANED,
SWAGELOK P/N DIBRT-031020-FIG11
ITEM 0003 QUANTITY: 1 EACH
MANIFOLD
DRAIN MANIFOLD,
SC11 CLEANED,
MOD TO ASSEMBLY-33888,
SWAGELOK P/N ASSEMBLY-57323
ITEM 0004 QUANTITY: 1 EACH
PANEL,
SC11 CLEANED,
FIGURE 13,
SWAGELOK P/N DIBRT-031020-FIG13
ITEM 0005 QUANTITY: 1 EACH
PANEL,
SC11 CLEANED,
FIGURE 15,
SP MV MIDDLE TEE,
SWAGELOK P/N DIBRT-031020-FIG15
ITEM 0006 QUANTITY: 1 EACH
PANEL
BALL VALVE-TEE WELD ASSEMBLY, REV. 1,
SC11 CLEANED/NO LUBE ON BALL VALVE,
SWAGELOK P/N ASSEMBLY-55975
ITEM 0007 QUANTITY: 2 EACH
GAUGE PANEL FIG 8, REVISION 8,
SC11 CLEANED,
SWAGELOK P/N DIBRT-010615-FIG8
ITEM 0008 QUANTITY: 1 EACH
GAUGE PANEL FIG 8, REVISION 0,
SWAGELOK P/N DIBRT-031020-FIG8
ITEM 0009 QUANTITY: 1 EACH
CD-7 DRAIN PANEL,
SC11 CLEANED/DOW CORNING 4 LUBRICANT,
SWAGELOK P/N DIBRT-022120-FIG3.A,
ITEM 0010 QUANTITY: 2 EACH
GAUGE PANEL FIG 7,
SWAGELOK P/N DIBRT010615-FIG7 (REVISION 6)
ITEM 0011 QUANTITY: 2 EACH
CP-14/15 VENT PANEL,
SC11 CLEANED/DOW CORNING 4 LUBRICANT,
DRAWING REV 2,
SWAGELOK P/N DIBRT-010615-FIG13,
ITEM 0012 QUANTITY: 2 EACH
DRAIN MANIFOLD,
ASSEMBLY-18657 WITH SC11 CLEAN & NO VALVE LUBRICANT,
SWAGELOK P/N ASSEMBLY-33322
ITEM 0013 QUANTITY: 4 EACH
IXSP UPPER & LOWER TEE PANEL,
SC11 CLEANED, NON-WELDED,
DRAWING REV 2,
SWAGELOK P/N DIBRT-010615-FIG17,
ITEM 0014 QUANTITY: 2 EACH
PF SP LOWER PANEL, WELDED,
SWAGELOK P/N DIBRT-061520-FIG18,
ITEM 0015 QUANTITY: 2 EACH
MVSP MIDDLE TEE PANEL,
SC11 CLEANED/DOW CORNING 4 LUBE, NON-WELDED,
DRAWING REV 2,
SWAGELOK P/N DIBRT-010615-FIG18A,
ITEM 0016 QUANTITY: 2 EACH
BALL VALVE-TEE WELD ASSEMBLY, REV. 1,
SC11 CLEANED/NO LUBE ON BALL VALVE,
SWAGELOK P/N ASSEMBLY-55975
ITEM 0017 QUANTITY: 1 EACH
BOUNDARY PANEL,
WELDED, 1/4" MALE FLARE INLET,
1/2" MALE FLARE OUTLET, 1/2" SWAGELOK DRAINS,
SWAGELOK P/N DIBRT021808NNSYREV.ECLSC,
PURCHASED SC-11 CLEAN
ITEM 0018 QUANTITY: 2 EACH
S8G PANEL,
SC11 CLEANED,
3/8" GLOBE VALVE PANEL MOUNTED,
SWAGELOK P/N DIBRT-050820-FIG16
TECHNICAL CAPABILITY/CONTRACTOR RESPONSIBILITY CERTIFICATION
Vendor hereby certifies that vendor’s item meets or exceeds all specifications and contractor responsibilities stated in this solicitation, in their entirety, with no exceptions. __________ (initials)
DATE: _________________________________________
File details come from the government source that posted it. Updated .