This is a System Requirements document for the Oregon Department of Corrections (ODOC) outlining specifications for a comprehensive imaging management solution. The procurement requires a vendor to provide a digital imaging system capable of handling multiple imaging modalities including Digital Radiography, MRI, CT, Ultrasound, and Dental imaging (panoramic radiography and intra-oral). All modalities must be included as built-in solutions rather than third-party additions. The system must support data migration from approximately 12 existing FUJI DR Workstation PCs, accommodate HL7 connections, and include a zero-footprint referring physician portal with unlimited users accessible via browser or smart device. The solution must be compatible with current equipment including Amrad Medical radiographic systems (Serial Number GR-14655), Dentsply Sirona Intra Oral Heliodent Plus machines, and Dentsply Sirona Pano Orthopos S 2D pano machines.
The system must store all data within the continental United States and provide secure data storage capabilities. Required imaging tools for technologists include flip/rotate functions, electronic shuttering, auto trimming, full-screen magnification and zoom, free text annotation with standard and customized markers, image information modification, and reject/repeat analysis tracking reports. The vendor must coordinate all maintenance and software updates with ODOC and the current imaging machine servicing provider. Additional requirements include the ability to import non-DICOM images in JPEG and PNG formats. No specific pricing terms, set-asides, incumbents, response deadlines, or funding sources are detailed in this requirements document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 35797 ITB.docx | DOCX document | |
| ATT B Plans~12.pdf | ||
| Preliminary Results~50.xlsx | XLSX spreadsheet | |
| ATT A Special Provisions and Specifications~19.pdf | ||
| Analytical Report.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1-System Requirements
Oregon Department of Corrections requirements:
The ability to handle multiple modalities from multiple locations throughout Oregon
• Digital Radiography
• MRI
• CT
• Ultrasound
• Dental (Panoramic radiography and Intra Oral)
Solution must include all modalities as part of the built-in solution, where no modality will be “programed” in as a third-party addition.
Data stored within the continental United States (“CONUS”)
The ability to handle an HL7 connection
Secure data storage
Comparison view
Mobile device access
Data Migration of image data residing on current FUJI DR Workstation PC (approximately 12 workstations)
Ability to import non DICOM images (jpeg, .png format)
Referring Physician Portal - Unlimited Users
A zero-footprint viewer that provides referring physicians with access to images and reports from any browser or smart device.
Imaging tools available to the technologists:
• Flip/Rotate 90°
• Electronic shuttering
• Auto Trimming
• Full screen magnification and zoom
• Free text annotation
• Annotation markers, standard and customized
• Modify image information
• Reject/Repeat Analysis tracking reports
Solution must coordinate maintenance and software updates with ODOC and the current imaging machine servicing provider
Ensure compatibility with current Amrad Medical radiographic systems (Serial Number:GR-14655), Dentsply Sirona Intra Oral Heliodent Plus intra oral x-ray machines, and Dentsply Sirona Pano Orthopos S 2D pano machines.