Attachment 1 - Statement of Work XJF Compressors..pdf
PDF 151 KB Posted
- Attached to
- XJF Compressor Rebuild
- Solicitation number
- FA466126Q0099
About this file
This is a Statement of Work (SOW) for repair services on XJF Compressors, Model XJF151N air conditioning units at Dyess Air Force Base, 7th Equipment Maintenance Squadron, effective August 20, 2026.
The contractor must receive four XJF151N compressors currently located at Dyess AFB Building 5204, diagnose and perform complete rebuilds including replacement of internal seals and all gaskets, and conduct functional checks. Repairs must be performed in strict accordance with the Frick Service Manual for the XJF 151mm Rotary Screw Compressor (Form S70-452 SM), using only genuine Frick Original Equipment Manufacturer (OEM) replacement parts; substituted or third-party parts are prohibited. This is designated as a one-time service. The contractor is responsible for all shipping costs from Dyess AFB, Texas to the contractor's facility and return shipping, with these costs to be reflected as a separate Contract Line Item Number (CLIN). The contractor must provide all supervision, personnel, maintenance equipment, tools, labor, and safety equipment compliant with OSHA and EPA guidelines. The contractor shall maintain clear communication with Aerospace Ground Equipment supervision and the Contracting Officer's Representative throughout the contract duration, providing notification of shipping itineraries, equipment receipt, initial inspection findings, any unforeseen issues requiring additional costs (which require prior written approval), and job completion. All replaced parts are treated as production scrap and disposed of by the contractor at their own facility in accordance with local commercial and environmental regulations at no additional government cost. The Government-Furnished Property (compressors) must be protected and preserved while in contractor custody, with the contractor liable for any loss, damage, destruction, or theft. Any rework required due to non-compliance with SOW standards shall be performed at no additional cost to the Government.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 2 - SCA WD CAO 6 August 2026.pdf | ||
| FA466126Q0099.pdf | ||
| Attachment 3 - Provisions and clauses - FA466126Q0099.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CAO 20 August 2026
Statement of Work (SOW)
For Aerospace Ground Equipment Flight for
XJF Compressors, Model XJF151N– Stellar Air Compressors.
Dyess AFB, 7 EMS: MXMG
1.0. Description of Services. The primary objective of this statement of work is to provide an outline of process for the repair for multiple XJF Compressors, Model XJF151N. The vendor will need to receive the compressors once removed from the air conditioning units, diagnose and perform complete rebuild on the equipment with warranty. Vendor must keep the
Aerospace Gound Equipment NCOIC, informed of the repair process and timeline.
Additionally, if the compressor cannot be rebuilt, provide NCOIC replacement equipment options, as applicable. This is a one-time service to repair the XJF Compressors, replace internal seals, replace all gaskets, check all machine functions.
1.1 All equipment is currently located at Dyess AFB, 7EMS, Aerospace Ground Equipment, Building 5204 2nd Street Dyess AFB, 79607
1.2 The Contractor is responsible for all costs and coordination associated with shipping the equipment from Dyess AFB, TX to the Contractor's facility, as well as the return shipping of the equipment back to Dyess AFB, TX. These shipping costs shall be priced and reflected as a separate Contract Line Item Number (CLIN) as stated in the solicitation and resulting contract.
- XJF Compressors, Model XJF151N
- Air Conditioner Compressors X 4
1.3 Contractor shall provide supervision, personnel, and maintenance equipment, tools, and labor necessary to inspect and perform the repair on equipment noted above as prescribed throughout this SOW. The contractor shall provide all required safety equipment.
All equipment discussed within this contract shall meet all OSHA, EPA and or any other applicable guidelines. All safety equipment must be used for its intended and designed purpose. Unsafe acts by the contractor will be reported to contractor supervision and the
Contracting Officer and maybe grounds for contract termination.
1.2.2. The contractor shall supply all the necessary special tooling required for maintenance.
1.4. The contractor shall provide the repair or replacement of components and equipment of the XJF Compressors, Model XJF151N, S/N 10241N21252874Z
1.5. For the purpose of this SOW, the repair procedure shall be performed in strict accordance with the Frick Service Manual for the XJF 151mm Rotary Screw Compressor
(Form S70-452 SM). This constitutes a brand name requirement. The contractor is required to use only genuine Frick Original Equipment Manufacturer (OEM) replacement parts for all repairs and maintenance. The use of substituted or third-party parts is not authorized. All procedures must comply with the guidelines and practices outlined in the service manual.
1.6. Disposal of all filters, equipment and/or parts deemed to contain hazardous waste shall be the responsibility of the government. The use of dumpsters on Dyess AFB by the contractor is prohibited unless otherwise stated in this SOW.
2.0 Communication and Reporting Requirements
2.1 General Coordination: The Contractor shall maintain clear and consistent communication with Aerospace Ground Equipment (AGE) supervision and the Contracting
Officer's Representative (COR) throughout the duration of the contract.
2.2. Delivery and Receipt: The Contractor shall coordinate and notify AGE supervision of all shipping itineraries, including the expected dates for the outbound shipment (from Dyess
AFB) and the return delivery. Upon receiving the equipment at the Contractor's repair facility, the Contractor must formally notify the COR that the equipment has arrived.
2.3. Initial Inspection: Following the receipt of the equipment at their facility, the Contractor shall perform an initial inspection and teardown. The Contractor must communicate the findings of this initial inspection to the COR to verify the condition of the equipment before proceeding with the core rebuild.
2.4. Reporting Issues: If any unforeseen issues, delays, or additional damages outside the original scope of this SOW are discovered at any point, the Contractor must immediately notify the Contracting Officer (CO) and COR. No additional work that would incur extra costs shall be performed without prior written approval from the CO.
2.5. Job Completion: The Contractor shall notify AGE supervision and the COR upon the successful completion of all repairs. This notification must occur prior to packaging the equipment for return shipment to ensure the Government is prepared to receive it.
2.6. The CS/CO may either require immediate rework or schedule an appointment to re-accomplish any work accomplished that is not up to the standards of this SOW. This rework will be documented and elevated to contractor management. There shall be no additional costs to the government as any related costs will be the contractor’s responsibility.
3.0. Government Furnished-Property (GFP)
3.1. GFP Designation: The air conditioner compressors provided to the Contractor for repair under this Statement of Work are classified as Government-Furnished Property (GFP).
3.2. Use of Property: The Contractor shall use the GFP exclusively for the performance of this contract. The Contractor shall not cannibalize, modify, or alter the GFP unless explicitly authorized in writing by the Contracting Officer (CO).
3.3. Protection and Liability: The Contractor shall establish adequate internal controls to protect, preserve, and maintain the GFP while it is in their custody. The Contractor’s responsibility extends from the initial receipt of the property at their facility until the repaired property is formally returned to and accepted by the Government. The Contractor shall be liable for any loss, damage, destruction, or theft of the GFP while it is in their possession.
3.4. Reporting of Loss or Damage: The Contractor shall promptly investigate and immediately report to the CO and the Contracting Officer’s Representative (COR) any incidents of loss, damage, destruction, or theft of the GFP as soon as the facts become known.
3.5. Disposition of Replaced Parts: Parts removed and replaced from the GFP as a result of the normal repair and overhaul process shall be treated as production scrap. The Contractor shall dispose of these replaced parts at their own facility in accordance with local commercial and environmental regulations at no additional cost to the Government.
4.0 Ombudsman
4.1 An ombudsman has been appointed to hear and facilitate the resolution of concerns from offerors, potential offerors, and others for this acquisition. When requested, the ombudsman will maintain strict confidentiality as to the source of the concern. The existence of the ombudsman does not affect the authority of the program manager, contracting officer, or source selection official. Further, the ombudsman does not participate in the evaluation of proposals, the source selection process, or the adjudication of protests or formal contract disputes. The ombudsman may refer the interested party to another official who can resolve the concern.
4.2 Before consulting with an ombudsman, interested parties must first address their concerns, issues, disagreements, and/or recommendations to the contracting officer for resolution. Consulting an ombudsman does not alter or postpone the timelines for any other processes (e.g., agency level bid protests, GAO bid protests, requests for debriefings, employee-employer actions, contests of OMB Circular A-76 competition performance decisions).
4.3 If resolution cannot be made by the contracting officer, the interested party may contact the ombudsman. Concerns, issues, disagreements, and recommendations that cannot be resolved at the Center/MAJCOM/FLDCOM/DRU ombudsman level, may be brought by the interested party for further consideration to the Department of the Air Force ombudsman, Associate Deputy Assistant Secretary (ADAS) (Contracting), SAF/AQC, 1060 Air Force
Pentagon, Washington DC 20330-1060, phone number (571) 256-2395, facsimile number
(571) 256-2431.
4.4 The ombudsman has no authority to render a decision that binds the agency.
4.5 Do not contact the ombudsman to request copies of the solicitation, verify offer due date, or clarify technical requirements. Such inquiries shall be directed to the contracting officer.
5.0 POTENTIAL ORGANIZATIONAL CONFLICT OF INTEREST
5.1 There is potential organizational conflict of interest (see RFO Subpart 9.5, Organizational and Consultant Conflicts of Interest)
5.1.1 As a part of the proposal, the offeror shall provide the contracting officer with complete information of previous or ongoing work that is in any way associated with the contemplated acquisition.
5.2 If award is made to the offeror, the resulting contract may include an organizational conflict of interest limitation applicable to subsequent Government work, at either a prime contract level, at any subcontract tier, or both. During evaluation of proposals, the
Government may, after discussions with the offeror and consideration of ways to avoid the conflict of interest, insert a special provision in the resulting contract which shall disqualify the offeror from further consideration for award of future contracts.
5.3 The organizational conflict of interest clause included in this solicitation may be modified or deleted during negotiations.
6.0 ELIMINATION OF USE OF CLASS I OZONE DEPLETING SUBSTANCES
(ODS)
6.1 Contractors shall not:
6.1.1 Provide any service or product with any specification, standard, drawing, or other document that requires the use of a Class I ODS in the test, operation, or maintenance of any system, subsystem, item, component, or process; or
6.1.2 Provide any specification, standard, drawing, or other document that establishes a test, operation, or maintenance requirement that can only be met by use of a Class I ODS as part of this contract/order.
6.2 For the purposes of Department of the Air Force policy, the following products that are pure (i.e., they meet the relevant product specification identified in AFI 32-7086[AR2] ) are
Class I ODSs:
6.2.1 Halons: 1011, 1202, 1211, 1301, and 2402;
6.2.2 Chlorofluorocarbons (CFCs): CFC-11, CFC-12, CFC-13, CFC-111, CFC-112, CFC-
113, CFC-114, CFC-115, CFC-211, CFC-212, CFC- 213, CFC-214, CFC-215, CFC-216,
and CFC-217, and the blends R-500, R-501, R-502, and R-503; and
6.2.3 Carbon Tetrachloride, Methyl Chloroform, and Methyl Bromide.
File details come from the government source that posted it. Updated .