Attachment_1_-_Specifications.pdf
PDF 110 KB Posted
- Attached to
- BLM-WY CFO Aluminum Box Culvert Federal contract opportunity
- Solicitation number
- 140L6225Q0026
About this file
This Performance Work Statement (PWS) details the procurement of a single aluminum box culvert fish passage structure for the Bureau of Land Management's Wyoming Cody Field Office. The specified culvert is a Contech Structure #39 or equivalent, with dimensions of 16'-10" span, 8'-3" rise, and 63.25' length, designed to HL-93 load standards. The culvert includes metal inlet and outlet headwalls, wingwalls, and a Steel Express foundation (4' wide x 1.9' thick), with a minimum cover of 2.7' and maximum cover of 4'.
Delivery is specified to the Park County Public Works Department Road & Bridge Division in Cody, Wyoming by October 1, 2025, with coordination required with the Contracting Officer Representative at least three business days before shipment. The contractor is responsible for providing all personnel, equipment, tools, and materials for supply and delivery, and must submit a Quality Control Process to the Contracting Officer prior to beginning work. The solicitation is a small business set-aside under NAICS code 2373107, with a firm-fixed price contract anticipated for this Paint Creek Project infrastructure component.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sheet_03-Culvert_1-Grading_Plan_0001.pdf | ||
| Sheet_05-Culvert_1-Section_Views_0001.pdf | ||
| Sol_140L6225Q0026_Amd_0001.pdf | ||
| Sheet_06-Culvert_1-Details_0001.pdf | ||
| Attachment_3_Questions_Addressed_0001.pdf | ||
| Sheet_04-Culvert_1-Plan_Profile_0001.pdf | ||
| Sheet_02-Culvert_1-Existing_Conditionsl_0001.pdf | ||
| Sol_140L6225Q0026.pdf | ||
| Attachment_2_-_Clauses_and_Provisions.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PERFORMANCE WORK STATEMENT
DESCRIPTION/SPECIFICATIONS/STATEMENT OF WORK
1 SCOPE OF WORK
The Contractor shall supply and deliver one fish passage structure according to the specifications called out in this document (section C.5).
Upon contract award, delivery of the specified fish passage structure shall occur on or before October, 1 2025 to the following Park County Facility:
Park County Public Works Department Road & Bridge Division
Cody District Shop 2816 Highway 120 South Cody, Wyoming 82414
Delivery shall be coordinated with the Contracting Officer Representative no later than three business days before product shipment.
2 CONTRACTOR FURNISHED ITEMS
The Contractor shall provide all personnel, equipment, tools, materials, services for the supply and delivery of one fish passage structure according to the contract specifications (section C.4).
3 Quality Control Plan
The Contractor shall maintain a Quality Control Process to ensure the requirements of the contract are achieved. A copy of the Contractor’s Quality Control Process shall be provided to the Contracting Officer prior to the start of contract work.
4 TASKS/CRITICAL SUBSTASKS AND STANDARDS
4.1 Task 1: Supply and delivery of the specified fish passage structure
Standard/AQL: Supply and delivery of the specified fish passage structure to Park County Road and Bridge in Cody, WY (Cody District Shop, 2816 Highway 120 South, Cody, Wyoming 82414). Upon contract award, delivery shall be coordinated with the Contracting Officer Representative no later than three business days before product shipment and delivery will be directed on-site for unloading and placement for temporary storage. Installation of the structure is not required by the manufacturer, vendor, or delivery company.
PERFORMANCE WORK STATEMENT
5 Product SPECIFICATIONS
One fish passage structure consisting of an aluminum box culvert and associated support footings, headwalls, and wingwalls more particularly described as:
• Quantity 1 Aluminum Box Culvert o Contech Structure #39 or Equivalent o Span: 16’-10” o Rise: 8’-3” o Length: 63.25’ length o Design Load: HL-93 o Shell Type: R1 o Minimum Cover: 2.7’ o Maximum Cover: 4’ o Metal inlet and outlet headwalls o Metal inlet and outlet wingwalls o Foundation Type: Steel Express (4’ wide x 1.9’ thick)