Attachment_3_Questions_Addressed_0001.pdf

PDF 131 KB Posted

Attached to
BLM-WY CFO Aluminum Box Culvert Federal contract opportunity
Solicitation number
140L6225Q0026
Issued by
Department of the Interior Bureau of Land Management Wyoming Region

About this file

This document is a Questions and Answers file for Solicitation 140L6225Q0026, addressing a Bureau of Land Management (BLM) Wyoming Cody Field Office procurement for an aluminum box culvert. The solicitation seeks a commercial item for a fish passage culvert as part of the Paint Creek Project, with delivery to Park County Public Works Department in Cody, Wyoming by October 1, 2025. Key requirements include an aluminum box culvert with specific structural components (headwalls, wingwalls) based on a Contech Structure #39 or equivalent, with precast foundations allowed if designed by a Wyoming licensed Professional Engineer. The procurement is a small business set-aside, requires SAM.gov registration, and is being conducted using simplified acquisition procedures with a firm-fixed price contract anticipated.

View the file

Other files for this federal contract opportunity

Other files attached to BLM-WY CFO Aluminum Box Culvert, newest first.
File Type Posted
Sheet_03-Culvert_1-Grading_Plan_0001.pdf PDF
Sol_140L6225Q0026_Amd_0001.pdf PDF
Sheet_06-Culvert_1-Details_0001.pdf PDF
Sheet_04-Culvert_1-Plan_Profile_0001.pdf PDF
Sheet_05-Culvert_1-Section_Views_0001.pdf PDF
Sheet_02-Culvert_1-Existing_Conditionsl_0001.pdf PDF
Attachment_1_-_Specifications.pdf PDF
Attachment_2_-_Clauses_and_Provisions.pdf PDF
Sol_140L6225Q0026.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation: 140L6225Q0026 AMD 0001

Questions and Answers

Solicitation: 140L6225Q0026 BLM WY CFO Aluminum Box Culvert

1. What are the dimensions of the headwalls?

a. Please see Attachment Sheet 06. As indicated a Contech Structure #39 (or equivalent) is shown. Utilize this drawing for dimensions only as shown for the culvert, headwalls, and wingwalls. Although a Contech structure is shown, similar equivalent structures shall be considered.

2. What are the dimensions of the wingwalls?

a. Please see Attachment Sheet 06. As indicated a Contech Structure #39 (or equivalent) is shown. Utilize this drawing for dimensions only as shown for shown, similar equivalent structures shall be considered

3. Would precast foundations be allowed versus Steel Express foundations if reviewed and sealed by Wyoming PE?

a. Yes, we will allow concrete precast foundations if designed by a Wyoming licensed PE

4. Is there a set of plans and specifications available for this site?

a. Yes, see attachments Sheet 02, 03, 04, 05, and 06.

5. Can the government provide the drawings, as its not attached to the specifications sheet.

a. Yes, see attachments Sheet 02, 03, 04, 05, and 06.

6. Do you need metal headwalls/wingwalls on both the outlet and inlet? If so, how long do you need the wingwalls to be?

a. Yes, both headwalls and wingwalls are required on both the inlet and outlet.

See Attachment Sheet 06. As indicated a Contech Structure #39 (or equivalent) is shown. Utilize this drawing for dimensions only as shown for shown, similar equivalent structures shall be considered

7. Can the structure be assembled on site?

a. This requirement is for the supply and delivery of the aluminum box culvert. Our project partners may be able to complete some assembly during installation.

8. Does the structure need to be installed?

a. No. This requirement is for the supply and delivery of the aluminum box culvert only.

File details come from the government source that posted it. Updated .