ATTACHMENT 1 Sheridan VAMC Steam Trap List.xlsx
XLSX spreadsheet 11 MB Posted
- Attached to
- J045--Steam Trap Survey and Repair
- Solicitation number
- 36C25923Q0425
About this file
This notice is a solicitation from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19 for a steam trap survey and repair at the Sheridan VAMC. The solicitation number is 36C25923Q0425 and seeks a contractor to conduct a steam trap survey of all steam traps located at the medical center as identified in the attached list. The selected contractor will be required to inspect, test, and repair any traps that are found to be faulty. Repairs and replacements must be made within 30 days of identification. The period of performance is from date of award through September 30, 2023.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S06 36C25923Q0425 0002.docx | DOCX document | |
| S06 36C25923Q0425 0001.docx | DOCX document | |
| S05 QUESTIONS AND RESPONSES.pdf | ||
| S01 RFQ 36C25923Q0425.docx | DOCX document | |
| ATTACHMENT 2 - LOS Certificate of Compliance.docx | DOCX document | |
| 36C25923Q0425_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Steam Trap Survey
| SORTING ORDER | TRAP# | OLD SURVEY TAG# | BUILDING/AREA | FLOOR | ROOM | LOCATION DESCRIPTION | ELEVATION (FT) | DRAWING# | APPLICATION | VALVE TYPE | VALVE STATUS | FAN STATUS | STEAM PRESSURE (PSIG) | PIPE SIZE | TRAP CONNECTION | TRAP TYPE | TRAP MAKE | TRAP MODEL | TRAP INLET TEMP (F) | TRAP OUTLET TEMP (F) | CONDITION | INITIAL SURVEY REPAIR PRIORITY: 1(high) to 5(low) | FOLLOW UP SURVEY REPAIR PRIORITY: 1(high) to 5(low) | RECOMMENDED REPLACEMENT | OPERATING HOURS (ANNUAL) | COMMENTS & NOTES | INITIAL SURVEY DATE | ORIGINAL SOW | ADDITIONAL SOW | FOLLOW UP SURVEY DATE | VALVE TYPE | VALVE STATUS | FAN STATUS | STEAM PRESSURE (PSIG) | PIPE SIZE | TRAP CONNECTION | TRAP TYPE | TRAP MAKE | TRAP MODEL | TRAP INLET TEMP (F) | TRAP OUTLET TEMP (F) | CONDITION | REPAIR PRIORITY: 1(high) to 5(low) | RECOMMENDED REPLACEMENT | OPERATING HOURS (ANNUAL) | COMMENTS & NOTES | ORIGINAL SOW | ADDITIONAL SOW | |
| 662 | 16 | 7046 | 31 | 1ST | 102B | Century flatwork ironer (inside unit) | 1 | MH31-111 | Other HE | 100 | 1" | FLG | TS | Gestra | MK25/2 | 332 | 202 | LM | 1 | 8,760 | 7/20/18 | X | 100 | 1" | FLG | TS | Gestra | MK 45-2 | 333 | 213 | OK | 8,760 | X | ||||||||||||||||
| 697 | 2 | 36 | 1ST | 100 | NE area, in pit | -2 | MH36-111 | Drip Leg | N/A | N/A | N/A | 15 | 1/2" | NPT | TS | Barnes & Jones | 1950 (angle) | 193 | 204 | FC | 2 | 8,760 | Trap is after PRV but appeared to be 75psi steam. | 7/23/18 | X | N/A | N/A | N/A | 15 | 1/2" | NPT | TS | Barnes & Jones | 1950 (angle) | 252 | 195 | OK | 8,760 | X | ||||||||||
| 3 | 1 | T | 1ST | TRAM | Between bldgs. 3 & 4 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 5,840 | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 4 | 2 | T | 1ST | TRAM | Between bldgs. 3 & 4 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FC | 5,840 | Trap is failed closed or there is an obstruction in the piping. Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | Trap is failed closed or there is an obstruction in the piping. Handle on steam valve is broken. | X | ||||||||||||||||
| 5 | 3 | T | 1ST | TRAM | Between bldgs. 3 & 4 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FC | 5,840 | Trap is failed closed or there is an obstruction in the piping. Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | Trap is failed closed or there is an obstruction in the piping. Handle on steam valve is broken. | X | ||||||||||||||||
| 6 | 26 | T | 1ST | TRAM | Between bldgs. 3 & 4 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 5,840 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | Handle on steam valve is broken. | X | ||||||||||||||||
| 7 | 27 | T | 1ST | TRAM | Between bldgs. 3 & 4 | 1 | UC | HV | Closed | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | Handle on steam valve is broken. Tried to open with a wrench but couldn't. | X | 3/25/19 | HV | Closed | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | Handle on steam valve is broken. Tried to open with a wrench but couldn't. | X | ||||||||||||||||
| 8 | 28 | T | 1ST | TRAM | Between bldgs. 3 & 4 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LB | 5,840 | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 9 | 29 | T | 1ST | TRAM | Between bldgs. 3 & 4 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LM | 5,840 | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 10 | 30 | T | 1ST | TRAM | Between bldgs. 3 & 4 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 5,840 | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 11 | 31 | T | 1ST | TRAM | Between bldgs. 3 & 4 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LM | 5,840 | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 12 | 32 | T | 1ST | TRAM | Between bldgs. 3 & 4 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FO | 5,840 | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 13 | 33 | T | 1ST | TRAM | Between bldgs. 3 & 4 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 5,840 | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 850 | 11 | 7061 | 86 | BASEMENT | SUB-BASE | N sub-basement, at WHT 1 | 1 | MH86-101 | DHWH | N/A | N/A | N/A | 14 | 1-1/2" | NPT | F&T | Nicholson | NTF25-2 | 245 | 211 | LM | 1 | 8,760 | 7/18/18 | X | N/A | N/A | N/A | 14 | 1-1/2" | NPT | F&T | Nicholson | NTF25-2 | 251 | 214 | FO | 1 | 8,760 | X | |||||||||
| 660 | 14 | 7044 | 31 | 1ST | 102B | Century flatwork ironer (inside unit) | 2 | MH31-111 | Other HE | 100 | 1/2" | FLG | TS | Gestra | MK45/2 | 330 | 213 | LM | 1 | 8,760 | 7/20/18 | X | 100 | 1/2" | FLG | TS | Gestra | MK45/2 | 341 | 230 | LM | 2 | 8,760 | Looks like this trap wasn't changed last cycle but instead trap #15 was changed. (300# Flange) | X | ||||||||||||||
| 837 | 34 | 7027 | 71 N | 1ST | 113 | 7 | MH71-111 | HUH | HV | Open | Off | 15 | 3/4" | NPT | F&T | Armstrong | 30-B3 | 250 | 204 | OK/LS | 5 | 8,760 | 6/28/18 | X | HV | Open | Off | 15 | 3/4" | NPT | F&T | Mepco | 44-215A | 265 | 207 | OK | 8,760 | X | |||||||||||
| 624 | 1 | 27D | BASEMENT | 3 | Drip Leg | N/A | N/A | N/A | 7 | 3/4" | NPT | F&T | ThermaFlo | FT15 | 234 | 201 | LM | 5,840 | X | 3/29/19 | N/A | N/A | N/A | 7 | 3/4" | NPT | F&T | ThermaFlo | FT15 | 239 | 202 | LM/B | 2 | 5,840 | Trap #'s 27D-1 & 27D-2 are in parallel. Only one trap is necessary. | X | |||||||||||||
| 18 | 4 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LM | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 19 | 5 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FC | 2,190 | Trap is failed closed or there is an obstruction in the piping. Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Trap is failed closed or there is an obstruction in the piping. Handle on steam valve is broken. | X | ||||||||||||||||
| 20 | 6 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FC | 2,190 | Trap is failed closed or there is an obstruction in the piping. Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Trap is failed closed or there is an obstruction in the piping. Handle on steam valve is broken. | X | ||||||||||||||||
| 21 | 7 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | see note | see note | N/A | 6 | 3/4" | NPT | see note | see note | see note | see note | 0 | Heating element removed and piping capped. | X | 3/25/19 | see note | see note | N/A | 6 | 3/4" | NPT | see note | see note | see note | 0 | Heating element removed and piping capped. | X | ||||||||||||||||
| 22 | 8 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 23 | 9 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 24 | 10 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 25 | 11 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 26 | 12 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 27 | 13 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LM | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 28 | 15 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FC | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 29 | 16 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 2,190 | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | X | ||||||||||||||||||
| 30 | 17 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FO | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 31 | 18 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FO | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 32 | 14 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FO | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 33 | 19 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Closed | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 2,190 | Handle on steam valve is broken. Tried to open with a wrench but couldn't. | X | 3/25/19 | HV | Closed | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. Tried to open with a wrench but couldn't. | X | ||||||||||||||||
| 34 | 20 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FO | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 35 | 21 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FO | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 36 | 22 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FO | 2,190 | Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. | X | ||||||||||||||||
| 37 | 23 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FC | 2,190 | Trap is failed closed or there is an obstruction in the piping. Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Trap is failed closed or there is an obstruction in the piping. Handle on steam valve is broken. | X | ||||||||||||||||
| 38 | 24 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FC | 2,190 | Trap is failed closed or there is an obstruction in the piping. Handle on steam valve is broken. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Trap is failed closed or there is an obstruction in the piping. Handle on steam valve is broken. | X | ||||||||||||||||
| 39 | 25 | T | 1ST | TRAM | Between bldgs. 3,4 & 64 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 2,190 | Handle on steam valve is broken. Water hammer in element. | X | 3/25/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 2,190 | Handle on steam valve is broken. Water hammer in element. | X | ||||||||||||||||
| 256 | 12B | 7 | BASEMENT | 016 | 1 | MH7-101 | DHWH | N/A | N/A | N/A | 17 | 1-1/2" | NPT | F&T | Armstrong | 30-B6 | 248 | 207 | OK | 8,760 | 6/27/18 | X | N/A | N/A | N/A | 17 | 1-1/2" | NPT | F&T | Armstrong | 30-B6 | 219 | 206 | LM | 2 | 8,760 | X | ||||||||||||
| 41 | 34 | T | 1ST | TRAM | Between bldgs. 4 & 5 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 3/26/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 42 | 35 | T | 1ST | TRAM | Between bldgs. 4 & 5 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LB | 5,840 | X | 3/26/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 43 | 36 | T | 1ST | TRAM | Between bldgs. 4 & 5 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FO | 5,840 | X | 3/26/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 44 | 37 | T | 1ST | TRAM | Between bldgs. 4 & 5 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LB | 5,840 | X | 3/26/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 45 | 38 | T | 1ST | TRAM | Between bldgs. 4 & 5 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LM | 5,840 | X | 3/26/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 46 | 39 | T | 1ST | TRAM | Between bldgs. 4 & 5 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 5,840 | X | 3/26/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 765 | 13 | 64 | CRAWL SPACE | 001C | NE corner | 1 | MH0-100 | Drip Leg | N/A | N/A | N/A | 75 | 3/4" | NPT | F&T | Sarco | FT-15 | 314 | 210 | OK | 8,760 | Should be a 75 psig steam trap. | New | ||||||||||||||||||||||||||
| 650 | 4 | 866 | 31 | BASEMENT | 009 | W wall | 6 | MH31-101 | Drip Leg | N/A | N/A | N/A | 12 | 1" | NPT | F&T | Hoffman Specialty | 540-4 | 243 | 206 | OK | 8,760 | 1"NPT safety pressure relief valve associated with this trap's LPS has lifted. | 7/20/18 | X | N/A | N/A | N/A | 12 | 1" | NPT | F&T | Hoffman Specialty | 540-4 | 231 | 176 | OK | 8,760 | X | ||||||||||
| 49 | 40 | T | 1ST | TRAM | Between bldgs. 5 & 6 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LM | 5,840 | X | 3/26/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 50 | 41 | T | 1ST | TRAM | Between bldgs. 5 & 6 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 3/26/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 51 | 42 | T | 1ST | TRAM | Between bldgs. 5 & 6 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 52 | 43 | T | 1ST | TRAM | Between bldgs. 5 & 6 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 53 | 44 | T | 1ST | TRAM | Between bldgs. 5 & 6 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 54 | 45 | T | 1ST | TRAM | Between bldgs. 5 & 6 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 590 | 1 | 23 | 1ST | N wall | 1 | Drip Leg | N/A | N/A | N/A | 13 | 3/4" | NPT | TS | Barnes & Jones | 134A | 246 | OK | 5,840 | New | ||||||||||||||||||||||||||||||
| 648 | 2 | 865 | 31 | BASEMENT | 010 | E wall | 7 | MH31-101 | Drip Leg | N/A | N/A | N/A | 100 | 3/4" | NPT | IB | Sarco | B-2-125 | 325 | 208 | OK | 8,760 | 7/20/18 | X | N/A | N/A | N/A | 60 | 3/4" | NPT | IB | Sarco | B-2-125 | 304 | 208 | OK | 8,760 | X | |||||||||||
| 119 | 34 | 7083 | 0 | SITE | MANHOLE 2 (Old 15) | SE corner of bldg. 110 | 0 | MH0-101 | Drip Leg | N/A | N/A | N/A | 75 | 3/4" | NPT | IB | Sarco | B-1H-125 | 131 | 133 | NIS | 2 | 8,760 | Trap identified as leaking in prior survey. Steam trap isolation valves are closed. Assume trap is still failed since it doesn't appear to have been changed after last survey. | 7/16/18 | X | N/A | N/A | N/A | 75 | 3/4" | NPT | IB | Bell & Gossett | 307 | 208 | OK | 4 | 8,760 | Small steam leak at strainer cap on 3/4" NPT strainer (see photo). | |||||||||
| Chris: | X | 3/9/20 | N/A | N/A | N/A | 75 | 60 | 3/4" | NPT | IB | Bell & Gossett | 307 | 208 | NT | 8,760 | 3/10/21: Can't test trap due to steam leak at same strainer.. 03/2020: Small steam leak at strainer cap on 3/4" NPT strainer (see photo). | |||||||||||||||||||||||||||||||||
| Chris: | O | 3/10/21 | N/A | N/A | N/A | 75 | 60 | 3/4" | NPT | IB | Bell & Gossett | 132 | 148 | see note | 1 | 8,760 | 3/28/22: Steam trap isolation valves closed. 3/10/21: Can't test trap due to steam leak at same strainer.. 03/2020: Small steam leak at strainer cap on 3/4" NPT strainer (hover mouse over cell for photo). | ||||||||||||||||||||||||||||||||
| Chris: | O | 3/28/22 | |||||||||||||||||||||||||||||||||||||||||||||||
| 367 | 9 | 7012 | 9 | 1ST | 108 | SE corner | 5 | MH9-111 | P&F HE | MCV | Part. Open | N/A | LPS | 1" | NPT | F&T | ITT Hoffman | FT015H-4 | 209 | 198 | NIS | 4,380 | Trap is at an angle. Straighten. Control valve is partially open but not enough to result in live steam at trap to enable its testing. | 6/28/18 | X | 4/1/19 | MCV | Part. Open | N/A | LPS | 1" | NPT | F&T | ITT Hoffman | FT015H-4 | 76 | 76 | see note | 4,380 | Trap is at an angle. Straighten. Control valve is partially open but not enough to result in live steam at trap to enable its testing. | X | ||||||||
| 779 | 5 | 811 | 71 | ATTIC | 402 | S end | 1 | MH71-141 | T&S HE | MCV | Part. Open | N/A | 30 | 3/4" | NPT | F&T | Sarco | FTI-30 | 207 | 205 | NCFS | 5,840 | Control valve is partially open but not enough to result in live steam at trap to enable its testing. | 6/29/18 | X | 4/3/19 | MCV | Part. Open | N/A | 30 | 3/4" | NPT | F&T | Sarco | FTI-30 | 113 | 108 | see note | 5,840 | Control valve is partially open, or leaking by, but not enough to result in live steam at trap to enable its testing. | X | ||||||||
| 1 | 1 | 695 | 0 | CRAWL SPACE | TRAM | Between bldgs. 3 & 4 | 5 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 229 | 209 | FO | 5,840 | 7/18/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | FT015H-3 | 233 | 204 | LM | 2 | 5,840 | X | |||||||||
| 61 | 46 | T | 1ST | TRAM | Between bldgs. 6 & 7 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Barnes & Jones | 134A | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Barnes & Jones | 134A | 5,840 | X | ||||||||||||||||||
| 62 | 47 | T | 1ST | TRAM | Between bldgs. 6 & 7 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 63 | 48 | T | 1ST | TRAM | Between bldgs. 6,7 & 61 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LS/M | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 64 | 49 | T | 1ST | TRAM | Between bldgs. 6,7 & 61 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 65 | 50 | T | 1ST | TRAM | Between bldgs. 6,7 & 61 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 66 | 51 | T | 1ST | TRAM | Between bldgs. 6,7 & 61 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LB | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 67 | 52 | T | 1ST | TRAM | Between bldgs. 6,7 & 61 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LB | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 68 | 53 | T | 1ST | TRAM | Between bldgs. 6,7 & 61 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LM | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 69 | 54 | T | 1ST | TRAM | Between bldgs. 6 & 7 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 70 | 55 | T | 1ST | TRAM | Between bldgs. 6 & 7 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Barnes & Jones | 134A | OK | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Barnes & Jones | 134A | 5,840 | X | ||||||||||||||||||
| 71 | 56 | T | 1ST | TRAM | Between bldgs. 6 & 7 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LM | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 72 | 57 | T | 1ST | TRAM | Between bldgs. 6 & 7 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LB | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 73 | 58 | T | 1ST | TRAM | Between bldgs. 6 & 7 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LS/M | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 74 | 59 | T | 1ST | TRAM | Between bldgs. 6 & 7 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LS/M | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 75 | 60 | T | 1ST | TRAM | Between bldgs. 6 & 7 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 591 | 2 | 23 | 1ST | N wall | 1 | Drip Leg | N/A | N/A | N/A | 13 | 3/4" | NPT | TS | Barnes & Jones | 134A | 246 | LS | 4 | 5,840 | New | |||||||||||||||||||||||||||||
| 104 | 22 | 7087 | 0 | SITE | MANHOLE 18 (Old 4) | Between bldgs. 17 & 18 | 2 | MH0-101 | Drip Leg | N/A | N/A | N/A | 30 | 3/4" | NPT | IB | Sarco | B12HS-30 | 265 | 209 | OK | 5,840 | 7/19/18 | X | 4/2/19 | N/A | N/A | N/A | 30 | 3/4" | NPT | IB | Sarco | B12HS-30 | 265 | 210 | OK | 5,840 | X | ||||||||||
| 909 | 24 | 90 | 1ST | 105 | SE side of boiler 3 | 12 | MH90-111 | Drip Leg | N/A | N/A | N/A | 105 | 3/4" | NPT | TS | Gestra | MK 45-2 | 340 | 206 | LS/M | 3 | 3/4" IB | 8,760 | New | |||||||||||||||||||||||||
| 79 | 61 | T | 1ST | TRAM | Between bldgs. 7 & 8 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FO | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 80 | 62 | T | 1ST | TRAM | Between bldgs. 7 & 8 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LM | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 81 | 63 | T | 1ST | TRAM | Between bldgs. 7 & 8 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LB | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 82 | 64 | T | 1ST | TRAM | Between bldgs. 7 & 8 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | FC | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 83 | 65 | T | 1ST | TRAM | Between bldgs. 7 & 8 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 84 | 66 | T | 1ST | TRAM | Between bldgs. 7 & 8 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 85 | 67 | T | 1ST | TRAM | Between bldgs. 7 & 8 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 86 | 68 | T | 1ST | TRAM | Between bldgs. 7 & 8 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 87 | 69 | T | 1ST | TRAM | Between bldgs. 7 & 8 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 88 | 70 | T | 1ST | TRAM | Between bldgs. 7 & 8 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 176 | 61 | 5 | BASEMENT | 001 | Caged area | 1 | MH5-101 | T&S HE | MCV | Closed | N/A | 9 | 3/4" | NPT | F&T | Armstrong | 15-B3 | 94 | NCFS | 5,840 | Condensate piping is completely insulated. | New | |||||||||||||||||||||||||||
| 114 | 29 | 760 | 0 | SITE | MANHOLE 6 (Old 11) | S of bldg. 3 | 1 | MH0-101 | Drip Leg | N/A | N/A | N/A | 75 | 1" | NPT | IB | Sarco | B3-75 | 315 | OK | 8,760 | 7/16/18 | X | N/A | N/A | N/A | 75 | 1" | NPT | IB | Sarco | B32S-75 | 313 | OK | 8,760 | X | |||||||||||||
| 332 | 6 | 723 | 8 | BASEMENT | 025 | 1 | MH8-101 | T&S HE | MCV | Part. Open | N/A | 23 | 1-1/4" | NPT | F&T | Watson McDaniel | FT-36 | 186 | 185 | NCFS | 5,840 | 6/28/18 | X | 3/27/19 | MCV | Part. Open | N/A | 23 | 1-1/4" | NPT | F&T | Watson McDaniel | FT-36 | 191 | 189 | see note | 5,840 | Control valve is partially open but not enough to result in live steam at the trap to enable testing it. | X | ||||||||||
| 92 | 71 | T | 1ST | TRAM | Between bldgs. 8 & 9 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | NIS | 5,840 | X | 4/3/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 93 | 72 | T | 1ST | TRAM | Between bldgs. 8 & 9 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LM | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 94 | 73 | T | 1ST | TRAM | Between bldgs. 8 & 9 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LM | 5,840 | X | 3/27/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 95 | 74 | T | 1ST | TRAM | Between bldgs. 8 & 9 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 5,840 | X | 3/28/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 96 | 75 | T | 1ST | TRAM | Between bldgs. 8 & 9 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | LM | 5,840 | X | 3/28/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 97 | 76 | T | 1ST | TRAM | Between bldgs. 8 & 9 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 5,840 | X | 3/28/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 98 | 77 | T | 1ST | TRAM | Between bldgs. 8 & 9 | 1 | UC | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | OK | 5,840 | X | 3/28/19 | HV | Open | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | 8C | 5,840 | X | ||||||||||||||||||
| 731 | 5 | 55 | 1ST | 101 | E wall | 1 | MH55-111 | Drip Leg | |||||||||||||||||||||||||||||||||||||||||
| 571 | 9 | 22 | BASEMENT | 7 | Drip Leg | N/A | N/A | N/A | 4 | 1/2" | NPT | IB | Armstrong | 880 | 99 | 93 | FC | 5,840 | Either the trap is failed closed or there is an obstruction in the piping. | X | 3/29/19 | N/A | N/A | N/A | 4 | 1/2" | NPT | IB | Armstrong | 880 | 110 | 100 | FC | 5 | 5,840 | Either the trap is failed closed or there is an obstruction in the piping. | X | ||||||||||||
| 783 | 9 | 815 | 71 | ATTIC | 402 | Before HWH | 1 | MH71-141 | Drip Leg | N/A | N/A | N/A | 30 | 3/4" | NPT | IB | Hoffman Specialty | 601A | 270 | 202 | OK | 8,760 | 6/29/18 | X | N/A | N/A | N/A | 30 | 3/4" | NPT | IB | Hoffman Specialty | 601A | 270 | 203 | OK | 8,760 | X | |||||||||||
| 372 | 1 | 12 | BASEMENT | 5 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | FT15 | 230 | 207 | OK | 5,840 | X | 3/28/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | FT15 | 5,840 | X | ||||||||||||||||||
| 858 | 19 | 744 | 86 | BASEMENT | CRAWLSPACE | N sub-basement, N crawl entrance | 2 | MH86-101 | Drip Leg | N/A | N/A | N/A | 25 | 1/2" | NPT | F&T | Armstrong | 880 | 269 | 203 | OK/LS | 5 | 8,760 | 7/19/18 | X | N/A | N/A | N/A | 25 | 3/4" | NPT | F&T | ITT Hoffman | FT125H-3 | 273 | 205 | OK | 8,760 | X | ||||||||||
| 105 | 23 | 775 | 0 | SITE | MANHOLE 17 (Old 5) | Between bldgs. 19 & 20 | 1 | MH0-101 | Drip Leg | N/A | N/A | N/A | 30 | 3/4" | NPT | IB | Armstrong | 811 | 264 | 211 | OK/LS | 5,840 | 7/19/18 | X | 4/2/19 | N/A | N/A | N/A | 30 | 3/4" | NPT | IB | Armstrong | 811 | 266 | 213 | LS | 4 | 5,840 | X | |||||||||
| 770 | 5 | 64 | 2ND | 207 | Mech. Rm. | 1 | Drip Leg | N/A | N/A | N/A | 9 | 3/4" | NPT | IB | Armstrong | 811 | 234 | 206 | OK | 8,760 | New | ||||||||||||||||||||||||||||
| 773 | 8 | 64 | 2ND | 207 | Mech. Rm. | 1 | Drip Leg | N/A | N/A | N/A | 9 | 3/4" | NPT | IB | Armstrong | 811 | 233 | 203 | OK | 8,760 | New | ||||||||||||||||||||||||||||
| 659 | 13 | 7043 | 31 | 1ST | 102B | Century flatwork ironer (inside unit) | 1 | MH31-111 | Other HE | 100 | 1" | FLG | TS | Gestra | MK25/2 | 333 | 207 | OK | 8,760 | 7/20/18 | X | 100 | 1" | FLG | TS | Gestra | MK25/2 | 333 | 197 | LM | 2 | 8,760 | (300# Flange) | X | |||||||||||||||
| 777 | 3 | 7023 | 71 | ATTIC | 402 | S end | 1 | MH71-141 | Drip Leg | N/A | N/A | N/A | 75 | 3/4" | NPT | IB | Hoffman Specialty | 601A | 313 | 202 | LS/M | 2 | 8,760 | Re-use copper fittings and dielectric unions and change nipple after strainer if necessary. | 6/29/18 | X | N/A | N/A | N/A | 75 | 3/4" | NPT | IB | Sarco | B-1H | 315 | 207 | OK | 8,760 | X | |||||||||
| Chris: | O | 4/4/22 | |||||||||||||||||||||||||||||||||||||||||||||||
| 506 | 1 | 19A | BASEMENT | 5 | Drip Leg | N/A | N/A | N/A | 6 | 1" | NPT | F&T | ThermaFlo | FT15 | 228 | 206 | OK | 5,840 | X | 3/30/19 | N/A | N/A | N/A | 6 | 1" | NPT | F&T | ThermaFlo | FT15 | 235 | 208 | OK | 5,840 | X | |||||||||||||||
| 527 | 1 | 949 | 20A | BASEMENT | 5 | MH20-101 | Drip Leg | N/A | N/A | N/A | 10 | 3/4" | NPT | F&T | ThermaFlo | FT-15 | 238 | 207 | OK | 5,840 | X | 4/2/19 | N/A | N/A | N/A | 10 | 3/4" | NPT | F&T | ThermaFlo | FT-15 | 245 | 205 | OK | 5,840 | X | |||||||||||||
| 921 | 6 | 91 | 1ST | 1ST FLOOR | NE area | 0 | MH91-111 | Radiator | HV | Part. Open | N/A | 75 | 1/2" | NPT | TD | Yarway | 29 | 146 | 105 | NT | 2,190 | Condensate return main may be partially, or completely, obstructed? | X | ||||||||||||||||||||||||||
| 677 | 1 | 903 | 35 | 1ST | 100 | SE end | 6 | MH35-111 | HUH | HV | Open | Off | 10 | 1/2" | NPT | IB | Armstrong | 880 | see note | 4 | 5,840 | Trap outlet isolation valve is closed. Assume trap is failed? Steam supply to building is off. | 7/23/18 | X | HV | Open | Off | 10 | 1/2" | NPT | IB | Sarco | B-1H | 230 | 204 | OK | 5,840 | X | |||||||||||
| 667 | 21 | 852 | 31 | 1ST | 102C | Dryer #6 | 6 | MH31-111 | Dryer | CV | Open | On | 100 | 1-1/2" | NPT | F&T | Sarco | FT-150 | 320 | 222 | OK | 1,095 | 7/20/18 | X | 4/4/19 | CV | Open | On | 60 | 1-1/2" | NPT | F&T | Sarco | FT-150 | 305 | 210 | OK | 1,095 | X | ||||||||||
| 739 | 8 | 833 | 61 | CRAWL SPACE | 100 | E wall | 3 | MH61-101 | Drip Leg | N/A | N/A | N/A | 10 | 1" | NPT | F&T | Hoffman Specialty | 55 | 161 | 130 | FC | 5,840 | 7/23/18 | X | 4/1/19 | N/A | N/A | N/A | 10 | 1" | NPT | F&T | ITT Hoffman | FT015H-4 | 240 | 205 | OK | 5,840 | X | ||||||||||
| 100 | 18 | 735 | 0 | 1ST | TRAM | Between bldgs. 86 & 87 | 1 | MH0-100 | AHU Coil | MCV | Open | Off | 8 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 234 | 204 | OK | 4,380 | Steam control valve is open although AHU fan is off. | 7/18/18 | X | 4/3/19 | MCV | Open | On | 8 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 231 | 202 | OK | 4,380 | X | |||||||||
| 707 | 14 | 37 | 1ST | 108 | N wall | 10 | MH37-111 | VUH | HV | Open | Off | 7 | 1/2" | NPT | TS | Barnes & Jones | 122 (angle) | FO | 5,840 | 7/20/18 | X | 4/4/19 | HV | Open | Off | 7 | 1/2" | NPT | TS | Barnes & Jones | 122 (angle) | 201 | 191 | OK | 5,840 | X | |||||||||||||
| 140 | 1 | 663 | 4 | BASEMENT | 006 | Before DHWH | 1 | MH4-101 | Drip Leg | N/A | N/A | N/A | 7 | 1/2" | NPT | IB | Hoffman Specialty | 601A | 227 | 204 | OK/LS | 5 | 8,760 | 6/26/18 | X | N/A | N/A | N/A | 7 | 1/2" | NPT | IB | Hoffman Specialty | B1030A | 233 | 207 | OK | 8,760 | X | ||||||||||
| 854 | 15 | 7074 | 86 | 1ST | SW MECH ROOM | Bottom of SW stairwell | 2 | MH86-112 | T&S HE | MCV | Part. Open | N/A | 15 | 1" | NPT | F&T | Hoffman Specialty | 55-4 | 222 | 196 | FO | 1 | 8,760 | 7/18/18 | X | MCV | Part. Open | N/A | 15 | 1" | NPT | F&T | ITT Hoffman | FT030H-4 | 131 | 213 | see note | 8,760 | Control valve is partially open, or leaking by, but not enough to result in live steam at trap to enable its testing. | X | |||||||||
| 235 | 7 | 674 | 6 | BASEMENT | 004 | Before DHWH | 1 | MH6-101 | Drip Leg | N/A | N/A | N/A | 15 | 1/2" | NPT | IB | Armstrong | 800 | 250 | 209 | OK | 8,760 | 6/27/18 | X | N/A | N/A | N/A | 15 | 1/2" | NPT | IB | Armstrong | 800 | 249 | 212 | OK | 8,760 | X | |||||||||||
| 271 | 18 | 691 | 7 | BASEMENT | 016 | 6 | MH7-101 | Drip Leg | N/A | N/A | N/A | 20 | 1/2" | NPT | IB | Armstrong | 880 | 260 | 205 | OK | 8,760 | 6/27/18 | X | N/A | N/A | N/A | 20 | 1/2" | NPT | IB | Armstrong | 880 | 262 | 208 | OK | 8,760 | X | ||||||||||||
| 375 | 4 | 12 | BASEMENT | 1 | Drip Leg | N/A | N/A | N/A | 20 | 3/4" | NPT | F&T | Sarco | FT-30 | 264 | 209 | LS | 5,840 | X | 3/28/19 | N/A | N/A | N/A | 20 | 3/4" | NPT | F&T | Sarco | FT-30 | 5,840 | X | ||||||||||||||||||
| 267 | 33 | 7 | 1ST | 111 | Cleveland kettle | 1 | MH7-111 | Kettle | HV | Closed | N/A | 20 | TS | OK | 1,095 | Trap has small diameter tubing w/ compression fittings. | 6/28/18 | X | 3/26/19 | HV | Closed | N/A | 20 | TS | FO | 4 | 1,095 | Trap has small diameter tubing w/ compression fittings. | X | ||||||||||||||||||||
| 596 | 5 | 923 | 24 | BASEMENT | 004 | Dish washing room | 3 | MH24-101 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | IB | ThermaFlo | IBH-30 | 226 | 209 | OK | 5,840 | 7/23/18 | X | 4/3/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | IB | ThermaFlo | IBH-30 | 234 | 210 | LM | 2 | 5,840 | X | |||||||||
| 366 | 8 | 778 | 9 | 1ST | 106 | W wall | 2 | MH9-111 | Drip Leg | N/A | N/A | N/A | 30 | 3/4" | NPT | IB | Armstrong | 800 | 267 | 205 | OK | 8,760 | 6/28/18 | X | N/A | N/A | N/A | 30 | 3/4" | NPT | IB | Armstrong | 800 | 272 | 205 | OK/LS | 5 | 8,760 | X | ||||||||||
| 252 | 40 | 7 | BASEMENT | 017 | 6 | MH7-101 | Drip Leg | N/A | N/A | N/A | 5 | 3/4" | NPT | IB | Armstrong | 880 | 224 | 175 | LS/M | 2 | 8,760 | 6/29/18 | X | N/A | N/A | N/A | 5 | 3/4" | NPT | IB | Armstrong | 880 | 230 | 198 | OK | 8,760 | X | ||||||||||||
| 804 | 3 | 789 | 71 N | 3RD | 300 | Before 71-WH-2 | 1 | MH71-131 | Drip Leg | N/A | N/A | N/A | 15 | 3/4" | NPT | IB | Armstrong | 800 | 247 | 207 | OK | 4,380 | 6/28/18 | X | N/A | N/A | N/A | 15 | 3/4" | NPT | IB | Armstrong | 800 | 259 | 209 | OK | 4,380 | X | |||||||||||
| 805 | 4 | 790 | 71 N | 3RD | 300 | Before 71-WH-1 | 1 | MH71-131 | Drip Leg | N/A | N/A | N/A | 22 | 3/4" | NPT | IB | Armstrong | 800 | 262 | 208 | OK/LS | 4,380 | 6/28/18 | X | 4/3/19 | N/A | N/A | N/A | 22 | 3/4" | NPT | IB | Armstrong | 800 | 260 | 204 | OK | 4,380 | X | ||||||||||
| 333 | 7 | 7010 | 8 | BASEMENT | 015 | 4 | MH8-101 | Drip Leg | N/A | N/A | N/A | 6 | 1" | NPT | F&T | Hoffman Specialty | 55 | 231 | 205 | OK/LS | 2,190 | 6/28/18 | X | 3/27/19 | N/A | N/A | N/A | 6 | 1" | NPT | F&T | Hoffman Specialty | 55 | 230 | 208 | FO | 1 | 2,190 | X | ||||||||||
| 835 | 32 | 71 N | 1ST | 112B | Inside sterilizer cabinet | 2 | MH71-111 | Drip Leg | N/A | N/A | N/A | 75 | 3/4" | NPT | F&T | ITT Hoffman | FT125H-3 | 310 | 207 | OK | 8,760 | Temporary PT tag says 71N-36 but should be 71N-32. | 6/29/18 | X | N/A | N/A | N/A | 75 | 3/4" | NPT | F&T | ITT Hoffman | FT125H-3 | 315 | 210 | OK | 8,760 | X | |||||||||||
| 851 | 12 | 737 | 86 | BASEMENT | SUB-BASE | Before DHWH PRV | 2 | MH86-101 | Drip Leg | N/A | N/A | N/A | 75 | 1/2" | NPT | IB | Hoffman Specialty | 60-1A | 309 | 205 | LS | 4 | 8,760 | 7/18/18 | X | N/A | N/A | N/A | 75 | 1/2" | NPT | IB | Hoffman Specialty | 60-1A | 317 | 210 | OK/LS | 6 | 8,760 | X | |||||||||
| 15 | 4 | 698 | 0 | CRAWL SPACE | TRAM | Between bldgs. 3,4 & 64 | 1 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Sarco | FT-15 | 193 | 179 | NIS | 2,190 | 7/18/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Sarco | FT-15 | 161 | 152 | NIS | 2,190 | X | ||||||||||
| 77 | 13 | 716 | 0 | CRAWL SPACE | TRAM | Between bldgs. 7 & 8 | 3 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | FT-15 | 212 | NIS | 5,840 | Trap is either not in service or flooded. | 7/17/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | FT-15 | 88 | NIS | 5,840 | X | |||||||||||
| 89 | 15 | 717 | 0 | CRAWL SPACE | TRAM | Between bldgs. 8 & 9 | 2 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 173 | NIS | 5,840 | Condensate leak at 3/4" union (dielectric) on trap outlet. | 7/17/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 102 | NIS | 5,840 | Condensate leak at 3/4" union (dielectric) on trap outlet. | X | ||||||||||
| Chris: | O | 3/10/21 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 83 | 86 | FC | 0.0 | 0 | 0.0 | 4 | 5,840 | Condensate leak at 3/4" union (dielectric) on trap outlet (hover mouse over cell for photo). | |||||||||||||||||||||||||||||
| Chris: | O | 3/30/22 | |||||||||||||||||||||||||||||||||||||||||||||||
| 136 | 1 | 7004 | 3 | BASEMENT | 010 | NW corner of mech. rm. | 3 | MH3-101 | Drip Leg | N/A | N/A | N/A | 75 | 3/4" | NPT | IB | Mepco | OBH-11 | 129 | 99 | FC | 2 | 8,760 | 6/26/18 | X | N/A | N/A | N/A | 75 | 3/4" | NPT | IB | Mepco | OBH-11 | 130 | 99 | FC | 5 | 8,760 | X | |||||||||
| 236 | 1 | 683 | 7 | BASEMENT | 009H | N area | 6 | MH7-101 | Drip Leg | N/A | N/A | N/A | 5 | 3/4" | NPT | F&T | Sarco | FT-15 | 224 | 200 | OK | 8,760 | 6/27/18 | X | N/A | N/A | N/A | 5 | 3/4" | NPT | F&T | Sarco | FT-15 | 232 | 198 | OK | 8,760 | X | |||||||||||
| 238 | 2 | 684 | 7 | BASEMENT | 009H | N area | 6 | MH7-101 | Drip Leg | N/A | N/A | N/A | 5 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 222 | 151 | OK | 8,760 | 6/27/18 | X | N/A | N/A | N/A | 5 | 3/4" | NPT | F&T | ITT Hoffman | FT030H-3 | 233 | 170 | OK | 8,760 | Trap inlet isolation valve leaking (dripping) from packing. | X | ||||||||||
| 393 | 3 | 14A | BASEMENT | 5 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ITT Hoffman | FT015H | 84 | 114 | FC | 5,840 | X | 3/28/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ITT Hoffman | FT015H | 89 | 121 | FC | 5 | 5,840 | X / New | ||||||||||||||
| 103 | 21 | 773 | 0 | SITE | MANHOLE 19 (Old 3) | Between bldgs. 15 & 16 | 2 | MH0-101 | Drip Leg | N/A | N/A | N/A | 30 | 3/4" | NPT | IB | Sarco | B12HS-30 | 264 | 209 | LS | 5,840 | 7/19/18 | X | 4/2/19 | N/A | N/A | N/A | 30 | 3/4" | NPT | IB | Sarco | B12HS-30 | 264 | 209 | see note | 3 | 5,840 | Steam trap is installed backwards and the isolation valves are closed. Need to install properly, open isolation valves and may want to use a new trap too. | X | ||||||||
| 842 | 39 | 7075 | 86 | ATTIC | ATTIC | Before T&S HE MCV | 4 | MH86-141 | Drip Leg | N/A | N/A | N/A | 25 | 1/2" | NPT | F&T | Watson McDaniel | WD-600L | 247 | 198 | OK | 8,760 | 7/19/18 | X | N/A | N/A | N/A | 25 | 1/2" | NPT | F&T | Watson McDaniel | WD-600L | 267 | 206 | OK | 8,760 | X | |||||||||||
| 48 | 9 | 709 | 0 | CRAWL SPACE | TRAM | Between bldgs. 5 & 6 | 1 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | FT-15 | 70 | NIS | 5,840 | 7/18/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | FT-15 | 157 | NIS | 5,840 | X | ||||||||||||
| 56 | 41 | 712 | 0 | CRAWL SPACE | TRAM | Between bldgs. 6 & 7 | 4 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Sarco | FTI-15 | 71 | NIS | 5,840 | Condensate dripping from 3/4" union on trap inlet. | 7/17/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Sarco | FTI-15 | 154 | NIS | 5,840 | X | |||||||||||
| 110 | 26 | 768 | 0 | SITE | MANHOLE 12 (Old 8) | W side of bldg. 8 | 2 | MH0-101 | Drip Leg | N/A | N/A | N/A | 75 | 3/4" | NPT | IB | ThermaFlo | IBH | 312 | 207 | LM | 1 | 8,760 | Temporary tag #ST0-29. Permanent tag will be 0-26. | 7/16/18 | X | N/A | N/A | N/A | 75 | 3/4" | NPT | IB | see note | 1 | 8,760 | Major steam leak and unable to access manhole and trap for testing. Leak appears to be at 3/4" NPT union before the trap. Replace union and nipples and possibly trap too. Temporary tag #ST 0-29. Permanent tag will be ST 0-26. | X | |||||||||||
| 255 | 12A | 7 | BASEMENT | 016 | 1 | MH7-101 | Drip Leg | N/A | N/A | N/A | 17 | 1-1/2" | NPT | F&T | Armstrong | 30-B6 | 248 | 207 | OK | 8,760 | 6/27/18 | X | N/A | N/A | N/A | 17 | 1-1/2" | NPT | F&T | Armstrong | 30-B6 | 219 | 206 | LM | 2 | 8,760 | X | ||||||||||||
| 625 | 2 | 27D | BASEMENT | 4 | Drip Leg | N/A | N/A | N/A | 7 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 114 | 90 | FC | 5,840 | X | 3/29/19 | N/A | N/A | N/A | 7 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 126 | 96 | FC | 6 | 5,840 | Trap #'s 27D-1 & 27D-2 are in parallel. Only one trap is necessary. | X | |||||||||||||
| 694 | 8 | 910 | 35 | 2ND | 200 | S end | 7 | MH35-111 | HUH | HV | Open | Off | 10 | 1/2" | NPT | TS | Barnes & Jones | 122 (strt.) | see note | 5,840 | Building steam pressure <0psig | 7/23/18 | X | 4/4/19 | HV | Open | Off | 10 | 1/2" | NPT | TS | Barnes & Jones | 122 (strt.) | 232 | 206 | LM/B | 2 | 5,840 | X | ||||||||||
| 695 | 9 | 35 | 2ND | 200 | N end | 7 | MH35-111 | HUH | HV | Open | Off | 10 | 1/2" | NPT | TS | Barnes & Jones | 122 (strt.) | see note | 5,840 | Building steam pressure <0psig | 7/23/18 | X | 4/4/19 | HV | Open | Off | 10 | 1/2" | NPT | TS | Barnes & Jones | 122 (strt.) | 148 | 135 | FL | 5 | 5,840 | X | |||||||||||
| 763 | 44 | 64 | CRAWL SPACE | NW corner | 1 | MH0-100 | Drip Leg | N/A | N/A | N/A | 1-1/4" | NPT | F&T | Hoffman Specialty | 55 | 256 | 210 | OK | 5,840 | Temporary tag number is ST 0-44 but should be ST 64 -11. | New | ||||||||||||||||||||||||||||
| 767 | 2 | 64 | 2ND | 207 | Mech. Rm. | 2 | T&S HE | MCV | Part. Open | N/A | 9 | 1-1/4" | NPT | F&T | Armstrong | A5-75 | 200 | 192 | see note | Control valve is partially open but not enough to result in live steam at the trap to enable testing it. Trap #'s 64-1 & 64-2 are in parallel. | New | ||||||||||||||||||||||||||||
| 869 | 28 | 756 | 86 | BASEMENT | CRAWLSPACE | S basement crawl space, S wall | 3 | MH86-101 | N/A | 15 | 3/4" | NPT | F&T | ITT Hoffman | FT015H | 214 | 163 | OK | Trap #'s 86-28 & 86-29 are in parallel. Not sure of application. | 7/19/18 | X | 4/3/19 | N/A | 15 | 3/4" | NPT | F&T | ITT Hoffman | FT015H | NLIS | Trap #'s 86-28 & 86-29 are in parallel. Not sure of application. Steam supply is disconnected and capped. | X | |||||||||||||||||
| 150 | 16 | 4 | BASEMENT | 008 | N wall | 2 | Radiator | see note | see note | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 | NIS | 0 | Steam supply disconnected and capped. | X | 3/25/19 | see note | see note | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 | 0 | Steam supply disconnected and capped. | X | ||||||||||||||||
| 151 | 15 | 4 | BASEMENT | 008 | S wall | 2 | Radiator | HV | Open | N/A | 6 | 1/2" | NPT | TS | Dunham Bush | 1E (angle) | FO | 2,190 | X | 3/25/19 | HV | Open | N/A | 6 | 1/2" | NPT | TS | Dunham Bush | 1E (angle) | 2,190 | X | ||||||||||||||||||
| 152 | 17 | 4 | BASEMENT | 008 | S wall | 2 | Radiator | see note | see note | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 | NIS | 0 | Steam supply disconnected and plugged. | X | 3/25/19 | see note | see note | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 | 0 | Steam supply disconnected and plugged. | X | ||||||||||||||||
| 153 | 18 | 4 | BASEMENT | 008 | S wall | 2 | Radiator | see note | see note | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 | NIS | 0 | Steam supply disconnected and plugged. | X | 3/25/19 | see note | see note | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 | 0 | Steam supply disconnected and plugged. | X | ||||||||||||||||
| 154 | 19 | 4 | BASEMENT | 008 | E wall | 2 | Radiator | see note | see note | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 | NIS | 0 | Steam supply disconnected and plugged. | X | 3/25/19 | see note | see note | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 | 0 | Steam supply disconnected and plugged. | X | ||||||||||||||||
| 155 | 20 | 4 | BASEMENT | 008 | N wall | 2 | Radiator | HV | Open | N/A | 6 | 1/2" | NPT | TS | Barnes & Jones | 122A | OK | 2,190 | X | 3/25/19 | HV | Open | N/A | 6 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | X | ||||||||||||||||||
| 156 | 21 | 4 | BASEMENT | 003 | S wall | 2 | UC | HV | Closed | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | No. 8 (angle) | FO | 2,190 | X | 3/25/19 | HV | Closed | N/A | 6 | 3/4" | NPT | TS | Hoffman Specialty | No. 8 (angle) | 2,190 | X | ||||||||||||||||||
| 157 | 22 | 4 | BASEMENT | 003 | N wall (unit in N stairwell) | 3 | UV | CV | Open | Off | 6 | 1" | NPT | TS | Dunham Bush | 3C (angle) | OK | 2,190 | X | 3/25/19 | CV | Open | Off | 6 | 1" | NPT | TS | Dunham Bush | 3C (angle) | 2,190 | X | ||||||||||||||||||
| 158 | 23 | 4 | BASEMENT | 003 | N wall | 2 | Radiator | TS | Closed | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 (angle) | FL | 2,190 | X | 3/25/19 | TS | Closed | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 (angle) | 2,190 | X | ||||||||||||||||||
| 159 | 24 | 4 | BASEMENT | 003 | Hallway, N wall | 2 | Radiator | TS | Closed | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 (angle) | OK | 2,190 | X | 3/25/19 | TS | Closed | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 (angle) | 2,190 | X | ||||||||||||||||||
| 160 | 25 | 4 | BASEMENT | 004 | 1 | Radiator | TS | Closed | N/A | 6 | 1/2" | NPT | TS | Sarco | H (strt.) | OK | 2,190 | X | 3/25/19 | TS | Closed | N/A | 6 | 1/2" | NPT | TS | Sarco | H (strt.) | 2,190 | X | |||||||||||||||||||
| 161 | 26 | 4 | BASEMENT | 002 | 2 | Radiator | HV | Closed | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 (angle) | OK | 2,190 | X | 3/25/19 | HV | Closed | N/A | 6 | 1/2" | NPT | TS | Hoffman Specialty | No. 8 (angle) | 2,190 | X | |||||||||||||||||||
| 162 | 27 | 4 | BASEMENT | S stairwell | 2 | UV | CV | Open | Off | 6 | 1" | NPT | TS | Dunham Bush | 3C (angle) | OK | 2,190 | X | 3/26/19 | CV | Open | Off | 6 | 1" | NPT | TS | Dunham Bush | 3C (angle) | 2,190 | X | |||||||||||||||||||
| 878 | 36 | 736 | 86 | BASEMENT | SUB-BASE | N sub-basement, near stairs | 7 | MH86-101 | Drip Leg | N/A | N/A | N/A | 25 | 1/2" | NPT | TD | Watson McDaniel | WD600 | 254 | 200 | OK | 8,760 | 7/18/18 | X | N/A | N/A | N/A | 25 | 1/2" | NPT | TD | Watson McDaniel | WD600 | 132 | 119 | FC | 5 | 8,760 | X | ||||||||||
| 2 | 2 | 696 | 0 | CRAWL SPACE | TRAM | Between bldgs. 3 & 4 | 4 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 231 | 209 | FO | 5,840 | 7/18/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | FT015H-3 | 233 | 210 | FO | 1 | 5,840 | X | |||||||||
| 14 | 3 | 697 | 0 | CRAWL SPACE | TRAM | Between bldgs. 3,4 & 64 | 0 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | FT-15 | 231 | 212 | OK | 5,840 | 7/18/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | FT-15 | 233 | 210 | OK | 5,840 | X | ||||||||||
| 16 | 5 | 699 | 0 | CRAWL SPACE | TRAM | Between bldgs. 3,4 & 64 | 1 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Sarco | FT-30 | 230 | 200 | FO | 5,840 | 7/18/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Sarco | FT-30 | 233 | 210 | OK | 5,840 | Trap inlet isolation valve is leaking from the packing. | X | |||||||||
| 17 | 6 | 700 | 0 | CRAWL SPACE | TRAM | Between bldgs. 3,4 & 64 | 2 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 226 | 204 | LB | 5,840 | 7/18/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | FT015H-3 | 231 | 210 | OK | 5,840 | X | ||||||||||
| 40 | 7 | 707 | 0 | CRAWL SPACE | TRAM | Between bldgs. 4 & 5 | 1 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | FT-15 | 221 | LM | 5,840 | Temperature with good camera was 224F. | 7/18/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | FT-15 | 222 | LM | 2 | 5,840 | Small steam leak at copper fitting on trap inlet piping (see photo). | ||||||||||
| Chris: | X | 3/11/20 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | 44-215A | 230 | 209 | OK | 5,840 | Small steam leak at copper fitting on trap inlet piping (see photo). | |||||||||||||||||||||||||||||||||
| Chris: | O | 3/10/21 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Mepco | 44-215A | 221 | 200 | OK | 5,840 | O | 3/30/22 | ||||||||||||||||||||||||||||||||
| 47 | 8 | 708 | 0 | CRAWL SPACE | TRAM | Between bldgs. 5 & 6 | 1 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 227 | OK | 5,840 | 7/18/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 229 | LM | 2 | 5,840 | X | |||||||||||
| 55 | 10 | 0 | CRAWL SPACE | TRAM | Between bldgs. 6 & 7 | 4 | MH0-100 | Radiator | N/A | N/A | N/A | 15 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | NLIS | 0 | Steam trap located through hole in the wall. On equipment upstairs that is disconnected. | 7/17/18 | X | N/A | N/A | N/A | 15 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | NLIS | 0 | Steam trap located through hole in the wall. On equipment upstairs that is disconnected. | X | ||||||||||||||
| 57 | 11 | 711 | 0 | CRAWL SPACE | TRAM | Between bldgs. 6 & 7 | 4 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 227 | FO | 5,840 | 7/17/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ITT Hoffman | FT015H-3 | 235 | OK | 5,840 | X | ||||||||||||
| 58 | 38 | 0 | CRAWL SPACE | TRAM | Between bldgs. 6 & 7 | 0 | MH0-100 | Drip Leg | N/A | N/A | N/A | 75 | 3/4" | NPT | F&T | Hoffman Specialty | 591 | LM/B | 1 | 8,760 | Condensate piping is copper. | 7/17/18 | X | N/A | N/A | N/A | 75 | 3/4" | NPT | F&T | ITT Hoffman | FT075H-3 | 322 | 227 | OK | 8,760 | X | ||||||||||||
| 59 | 40 | 0 | CRAWL SPACE | TRAM | Between bldgs. 6 & 7 | 0 | MH0-100 | Drip Leg | N/A | N/A | N/A | 32 | 3/4" | NPT | F&T | Hoffman Specialty | 550 | LS | 4 | 8,760 | No temporary tag on trap. Condensate piping is copper. | 7/17/18 | X | N/A | N/A | N/A | 32 | 3/4" | NPT | F&T | ITT Hoffman | FT030H-3 | 272 | 208 | OK | 8,760 | X | ||||||||||||
| 60 | 39 | 713 | 0 | CRAWL SPACE | TRAM | Between bldgs. 6 & 7 | 0 | MH0-100 | Drip Leg | N/A | N/A | N/A | 9 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | OK | 8,760 | 7/17/18 | X | N/A | N/A | N/A | 9 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 236 | 205 | LM | 2 | 8,760 | Difficult to test due to ultrasonic noise in the area. | X | |||||||||||
| 76 | 12 | 715 | 0 | CRAWL SPACE | TRAM | Between bldgs. 7 & 8 | 2 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | TD | Nicholson | NTD600 | 225 | OK | 5,840 | 7/17/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | TD | Nicholson | NTD600 | 229 | OK | 5,840 | X | ||||||||||||
| 78 | 14 | 7016 | 0 | 1ST | TRAM | Bldg. 7, Rm. 101 (custodial floor cleaner storage room) | 8 | MH0-100 | HUH | HV | Open | Off | 6 | 3/4" | NPT | TD | Nicholson | NTD600 | 228 | 195 | OK | 5,840 | Condensate currently being dumped to drain. Need to replace the 3/4"NPT check valve and repipe into the condensate return system. | 7/17/18 | X | 4/3/19 | HV | Open | Off | 6 | 3/4" | NPT | TD | Nicholson | NTD600 | 229 | 146 | OK | 5,840 | Condensate currently being dumped to drain. Need to replace the 3/4"NPT check valve and repipe into the condensate return system. | X | ||||||||
| 90 | 16 | 718 | 0 | CRAWL SPACE | TRAM | Between bldgs. 8 & 9 | 2 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | FT-15 | 223 | OK | 5,840 | Line is uninsulated. | 7/17/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | ThermaFlo | FT-15 | 220 | OK | 5,840 | Line is uninsulated. | X | ||||||||||
| 91 | 37 | 0 | CRAWL SPACE | TRAM | BIdg. 9 (best access through window in rm. 103) | 2 | MH0-100 | Drip Leg | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 222 | OK | 5,840 | Line is uninsulated. | 7/17/18 | X | 4/1/19 | N/A | N/A | N/A | 6 | 3/4" | NPT | F&T | Hoffman Specialty | 55 | 223 | 206 | OK/LS | 5 | 5,840 | Line is uninsulated. | X | |||||||||
| 179 | 11 | 5 | 1ST | 116 | 1 | UC | Closed | N/A | 9 | 1/2" | NPT | TS | Dunham Bush | 1E (angle) | NIS | 2,190 | Changed thermostat setting but unit still did not energize. | X | 3/26/19 | Closed | N/A | 9 | 1/2" | NPT | TS | Dunham Bush | 1E (angle) | 2,190 | Changed thermostat setting but unit still did not energize. | X | |||||||||||||||||||
| 180 | 12 | 5 | 1ST | 116 | 1 | UC | Closed | N/A | 9 | 1/2" | NPT | TS | Dunham Bush | 1E (angle) | NIS | 2,190 | Changed thermostat setting but unit still did not energize. | X | 3/26/19 | Closed | N/A | 9 | 1/2" | NPT | TS | Dunham Bush | 1E (angle) | 2,190 | Changed thermostat setting but unit still did not energize. | X | |||||||||||||||||||
| 181 | 13 | 5 | 1ST | 115 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Dunham Bush | 1E (angle) | OK | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Dunham Bush | 1E (angle) | 2,190 | X | |||||||||||||||||||
| 182 | 14 | 5 | 1ST | 118 | 1 | UC | HV | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | NIS | 2,190 | Unit did not energize when steam valve opened. | X | 3/26/19 | HV | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | Unit did not energize when steam valve opened. | X | |||||||||||||||||
| 183 | 15 | 5 | 1ST | 118A | 1 | UC | HV | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122S | OK | 2,190 | X | 3/26/19 | HV | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122S | 2,190 | X | |||||||||||||||||||
| 184 | 16 | 5 | 1ST | 119 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | OK | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | X | |||||||||||||||||||
| 185 | 17 | 5 | 1ST | S hallway | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | OK | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | X | |||||||||||||||||||
| 186 | 18 | 5 | 1ST | 125 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | OK | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | X | |||||||||||||||||||
| 187 | 19 | 5 | 1ST | 125 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | NIS | 2,190 | Unit did not energize thermostatic valve opened. | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | Unit did not energize thermostatic valve opened. | X | |||||||||||||||||
| 188 | 20 | 5 | 1ST | 125 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | C | 2,190 | Either the trap is failed closed, the thermostatic valve is not opening or there is an obstruction in the piping. | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | Either the trap is failed closed, the thermostatic valve is not opening or there is an obstruction in the piping. | X | |||||||||||||||||
| 189 | 21 | 5 | 1ST | 124 | 1 | UC | TS | Closed | N/A | 9 | 3/4" | NPT | TS | ITT Hoffman | (angle) | FO | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 3/4" | NPT | TS | ITT Hoffman | (angle) | 2,190 | X | |||||||||||||||||||
| 190 | 22 | 5 | 1ST | 123 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | FC | 2,190 | Trap is failed closed or there is an obstruction in the piping. | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | Trap is failed closed or there is an obstruction in the piping. | X | |||||||||||||||||
| 191 | 23 | 5 | 1ST | 121 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | OK | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | X | |||||||||||||||||||
| 192 | 24 | 5 | 1ST | 121 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | C | 2,190 | Either the trap is failed closed, the thermostatic valve is not opening or there is an obstruction in the piping. | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | Either the trap is failed closed, the thermostatic valve is not opening or there is an obstruction in the piping. | X | |||||||||||||||||
| 193 | 25 | 5 | 1ST | 121A | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Trane | B1 (angle) | NIS | 2,190 | Unit did not energize when thermostatic valve opened. | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Trane | B1 (angle) | 2,190 | Unit did not energize when thermostatic valve opened. | X | |||||||||||||||||
| 194 | 26 | 5 | 1ST | 101 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | FO | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | X | |||||||||||||||||||
| 195 | 27 | 5 | 1ST | 101 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Tunstall | (angle) | OK | 2,190 | Actuator on thermostatic control valve is broken. | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Tunstall | (angle) | 2,190 | Actuator on thermostatic control valve is broken. | X | |||||||||||||||||
| 196 | 28 | 5 | 1ST | 102 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | OK | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | X | |||||||||||||||||||
| 197 | 29 | 5 | 1ST | 105 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | OK | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | X | |||||||||||||||||||
| 198 | 30 | 5 | 1ST | 107 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | ITT Hoffman | 17C (angle) | OK | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | ITT Hoffman | 17C (angle) | 2,190 | X | |||||||||||||||||||
| 199 | 31 | 5 | 1ST | 108 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | OK | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | X | |||||||||||||||||||
| 200 | 32 | 5 | 1ST | 108 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | FO | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | X | |||||||||||||||||||
| 201 | 33 | 5 | 1ST | 108 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | C | 2,190 | Either the trap is failed closed, the thermostatic valve is not opening or there is an obstruction in the piping. | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | Either the trap is failed closed, the thermostatic valve is not opening or there is an obstruction in the piping. | X | |||||||||||||||||
| 202 | 34 | 5 | 1ST | 109 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | ITT Hoffman | 17C (angle) | OK | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | ITT Hoffman | 17C (angle) | 2,190 | X | |||||||||||||||||||
| 203 | 35 | 5 | 1ST | 110 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | FO | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | X | |||||||||||||||||||
| 204 | 36 | 5 | 1ST | 111 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Dunham Bush | 1E (angle) | LS | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Dunham Bush | 1E (angle) | 2,190 | X | |||||||||||||||||||
| 205 | 37 | 5 | 1ST | 112 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | LB | 2,190 | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | X | |||||||||||||||||||
| 206 | 38 | 5 | 1ST | 114A | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | NIS | 2,190 | Steam supply to unit shut off below. | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Barnes & Jones | 122A | 2,190 | Steam supply to unit shut off below. | X | |||||||||||||||||
| 207 | 39 | 5 | 2ND | 213 | 1 | UC | see note | Closed | N/A | 9 | 1/2" | NPT | TS | see note | see note | NIS | 2,190 | No access. Shelves in the way. | X | 3/26/19 | see note | Closed | N/A | 9 | 1/2" | NPT | TS | see note | see note | 2,190 | No access. Shelves in the way. | X | |||||||||||||||||
| 208 | 40 | 5 | 2ND | 214 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Tunstall | (angle) | NIS | 2,190 | Unit did not energize when thermostatic valve opened. | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | Tunstall | (angle) | 2,190 | Unit did not energize when thermostatic valve opened. | X | |||||||||||||||||
| 209 | 41 | 5 | 2ND | 217 | 1 | UC | TS | Closed | N/A | 9 | 1/2" | NPT | TS | ITT Hoffman | 17C (angle) | NIS | 2,190 | No access to change thermostatic valve setting in order to energize unit. | X | 3/26/19 | TS | Closed | N/A | 9 | 1/2" | NPT | TS | ITT Hoffman | 17C (angle) | 2,190 | No access to change thermostatic valve setting in order to energize unit. | X |