This is a Salient Characteristics document for a Building 3 Access Control System (ACS) installation at Fairchild Air Force Base in Washington, effective 1 December 2025.
The contractor shall deliver and install a standalone Advantor SFXi access control system with associated equipment at 1001 West Boston Ave, Building 3, Fairchild AFB, WA 99011. Required deliverables include: one SFXi system with closed network switch; one computer monitor, keyboard, and mouse; one APC SMX1500RM2UC uninterrupted power supply; one CIS C9200CX-12T-2X2G-A network switch with DNA License and rackmount; one laser jet black and white printer; four Infraguard II Rev 7 control panels (model IG2PCBASTD); two ALT EFLOW6N8 power supplies; ten 12-volt 7 Amp Hour batteries (model BAT YA-NP712GNVT); nine HID RPK40-H PIV Class Readers (model 921PHRNEK0001U); one HID RP40-H PIV Class Reader (model 920PHRNEK0003U); access control system training for up to 10 personnel; and 100 proximity cards with site code 65 and start sequence 1001. Work will be performed during normal business hours Monday through Friday, 7:00 AM to 4:00 PM, excluding federal holidays. Services provided under this contract are determined not to be mission essential for performance during a crisis in accordance with DoDI 1100.22.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 2 - Statement of Work.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS
BLDG. 3 ACS INSTALLATION
1 December 2025
1.0. DESCRIPTION OF SERVICES. The contractor shall deliver and install standalone access control system (ACS), Infraguard Revision 7 panels, uninterrupted power supply, panel batteries, laser jet printer, and ACS and access control training for Bldg. 3.
2.0. SCOPE OF WORK DEFINED. The contractor will deliver via the approved shipping method and install ACS equipment.
3.0. GOVERNMENT FACILITIES AND SERVICES. The Government shall receive shipment at 1001 West Boston Ave, Bldg. 3 Fairchild AFB WA, 99011, Fairchild AFB.
4.0. GENERAL INFORMATION.
4.1. Hours of Operation: Normal hours of operation are Monday through Friday 7am – 4pm. Work will not be completed on federal holidays.
5.0. CONTINUATION OF MISSION ESSENTIAL FUNCTIONS. IAW DoDI 1100.22 (Policy and Procedures for Determining Workforce Mix), and any applicable Air Force implementation, unless otherwise directed by an authorized Government representative, it is determined that services provided under this contract are not mission essential for performance during a crisis.
6.0. SALIENT CHARACTERISTICS.
6.1. Contractor/vendor will provide and install:
6.1.1. One (1) Advantor standalone SFXi access control system with closed network switch.
6.1.2. One (1) computer monitors keyboard, and mouse compatible with SFXi.
6.1.3. One (1) uninterrupted power supply, APC SMX1500RM2UC SMART-UPS SMX 1500VA Tower/Rack.
6.1.4. One (1) CIS C9200CX-12T-2X2G-A With DNA License and rackmount
6.1.5. One (1) Laser Jet black and white printer.
6.1.6. Four (4) Infraguard II Rev 7, model IG2PCBASTD panel.
6.1.7. Two (2) ALT EFLOW6N8 12/24VDC 6A 8 Fuse Power Supply
6.1.8. Ten (10) 12-volt, 7 Amp Hour, model BAT YA-NP712GNVT Battery 12V 7AH.
6.1.9. Nine (9) HID 921PHRNEK0001U RPK40-H PIV Class Readers
6.1.10. One (1) HID 920PHRNEK0003U RP40-H PIV Class Reader.
6.1.11. Access Control System training for up to 10 personnel.
6.1.12. One hundred (100) proximity cards, site code 65 start sequence 1001.