Attachment 1 - PWS - 14 August 2026.pdf
PDF 211 KB Posted
- Attached to
- 22 MXS - Walk-In Oven Troubleshoot
- Solicitation number
- FA462126Q0045
About this file
This is a Performance Work Statement (PWS) for the troubleshooting and repair of an industrial vacuum oven at Hangar 1124N, McConnell Air Force Base, Kansas, dated 14 August 2026.
The procurement seeks professional services from a qualified Industrial Oven Service Technician to conduct on-site evaluation, verify system functionality, and restore base operations of an existing industrial vacuum oven, with all work to be completed within 90 calendar days of contract award. The contractor must provide all labor, tools, and equipment necessary to perform on-site technical support, conduct thorough physical inspections of oven doors and vacuum system components, restore baseline functionality of heating elements with proper heat distribution and airflow, and collect comprehensive diagnostic data to support a detailed corrective maintenance and repair plan. The contractor must deliver a detailed written findings report documenting inspection results, baseline system data, and specific recommendations for future repairs or component replacements within a mutually agreed-upon timeframe following completion of the on-site visit. Minimum contractor qualifications include demonstrated experience servicing, repairing, and calibrating industrial heat processing and vacuum oven systems of similar size and complexity, with technicians fully qualified to perform work on commercial and industrial thermal systems. The PWS includes a special contract requirement prohibiting the use of Class I Ozone Depleting Substances (ODS), including specific halons, chlorofluorocarbons (CFCs), carbon tetrachloride, methyl chloroform, and methyl bromide, in test, operation, or maintenance activities.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment FA462126Q00450002 Signed.pdf | ||
| Attachment 6 - Site Visit Questions and Resposnes 2 September.pdf | ||
| Amendment 1 - FA462126Q00450001 Signed.pdf | ||
| Attachment 5 - Short Term Pass Request.pdf | ||
| Attachment 2 - Vendor Questions and Corresponding Government Answers.pdf | ||
| Attachment 3 - Walk In Oven Picture Portfolio.pdf | ||
| Attachment 4 - General Installation and Operation and Maintenance Instructions for Oven.pdf | ||
| image006.jpg | JPG image | |
| image009.jpg | JPG image | |
| image004.jpg | JPG image | |
| image013.jpg | JPG image | |
| image010.jpg | JPG image | |
| image007.jpg | JPG image | |
| image001.jpg | JPG image | |
| image005.jpg | JPG image | |
| image002.jpg | JPG image | |
| image011.jpg | JPG image | |
| image008.jpg | JPG image | |
| image003.jpg | JPG image | |
| image012.jpg | JPG image | |
| Solicitation - FA462126Q0045 Signed.pdf |
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hangar 1124N Walk-in Oven Troubleshoot and Repair Performance Work Statement (PWS)
14 August 2026
Performance Work Statement
Hangar 1124N Walk-in Oven Troubleshoot and Repair
(Replacement of parts to fix the Air Compressor)
McConnell AFB, KS
Hangar 1124N Walk-in Oven Troubleshoot and Repair Performance Work Statement (PWS)
PERFORMANCE WORK STATEMENT (PWS)
Project Title: Evaluation, Verification, and Restoration of Industrial Vacuum Oven Functionality
1. Objective The objective of this procurement is to acquire the professional services of a qualified Industrial Oven Service Technician to conduct an on-site evaluation, verify system functionality, and restore the base operations of an existing industrial vacuum oven.
2. Scope of Work The contractor shall provide all labor, tools, and equipment necessary to perform the following tasks, with all work to be completed within 90 calendar days of contract award:
• On-Site Technical Support: Provide a qualified Industrial Oven Service Technician on-site
• System Inspections: Conduct a thorough physical inspection of the oven doors and evaluate the overall condition and performance of the vacuum system.
• Functional Restoration: Restore the baseline functionality of the oven (heating elements), specifically focusing on achieving and maintaining proper heat distribution and airflow.
• Data Collection: Collect comprehensive diagnostic data across all oven systems to develop and support a detailed corrective maintenance and repair plan.
3. Contractor Qualifications To be considered for award, the contractor must meet the following minimum qualifications:
• Demonstrated experience in servicing, repairing, and calibrating industrial heat processing and vacuum oven systems of similar size and complexity.
• Technicians must be fully qualified to perform work on commercial/industrial thermal systems.
4. Deliverables
• Written Findings Report: The contractor must provide a detailed written report documenting all inspection findings, baseline system data collected, and specific recommendations for future repairs or component replacements. This report is to be delivered within a mutually agreed-upon timeframe following the completion of the technician's on-site visit.
5. Special Contract Requirements
Elimination of Use of Class I Ozone Depleting Substances (ODS)(a) The Contractor shall not:(1) Provide any service or product with any specification, standard, drawing, or other document that requires the use of a Class I ODS in the test, operation, or maintenance of any system, subsystem, item, component, or process; or (2) Provide any specification, standard, drawing, or other document that establishes a test, operation, or maintenance requirement that can only be met by use of a Class I ODS as part of this contract/order. (b) For the purposes of Air Force policy, the following products that are pure are Class I ODSs: (1) Halons: 1011, 1202, 1211, 1301, and 2402(2) Chlorofluorocarbons (CFCs):
CFC-11, CFC-12, CFC-13, CFC-111, CFC-112, CFC-113, CFC-114, CFC-115, CFC-211, CFC-212, CFC-213, CFC-214, CFC-215, CFC-216, and CFC-217, and the blends R-500, R-501, and R-503;
and(3) Carbon Tetrachloride, Methyl Chloroform, and Methyl Bromide.