Attachment 1 - Pricing Schedule Hazwaste_.xlsx

XLSX spreadsheet 54 KB Posted

Attached to
CRREL HAZARDOUS WASTE DISPOSAL SERVICES Federal contract opportunity
Solicitation number
W913E522R0010
Issued by
Department of the Army Corps of Engineers Engineer Research and Development Center

About this file

This pricing schedule and solicitation provide details for hazardous waste disposal services. The U.S. Army Corps of Engineers Engineer Research and Development Center is seeking firm-fixed price hazardous waste disposal and container provision services at the Cold Regions Research and Engineering Laboratory in Hanover, New Hampshire. The pricing schedule lists estimated quantities and unit rates for various waste streams including batteries, lab packs, and fluorescent lighting as well as container rental, testing, and expedited removal services. Pricing is to be provided for a base year and four one-year options.

View the file

Other files for this federal contract opportunity

Other files attached to CRREL HAZARDOUS WASTE DISPOSAL SERVICES, newest first.
File Type Posted
REVISED_ Attachment 1 Pricing Schedule 22 August 2022.xlsx XLSX spreadsheet
CRREL Hazardous Waste Questions and Answers No. 2 18 August 2022 W913E522R0010.pdf PDF
CRREL Hazardous Waste Questions and Answers 17 August 2022 W913E522R0010.pdf PDF
Solicitation - W913E522R0010.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Price Schedule Price Schedule

Waste DescriptionEst. Qty
(12 Months)U/IBase
U/PBase
ExtendedOption 1
U/POption
ExtendedOption 2
U/POption
ExtendedOption 3
U/POption
ExtendedOption 4
U/POption

Extended

Monthly Satellite Accumulation Area inspection12month
CRREL One Time Waste Clean Out1JOB$0.00$0.00$0.00$0.00$0.00$0.00$0.00$0.00
Repackage Waste (56- to 95-gallon container) (See 1.2.12).0EA
Provide containers, 55-gl, steel, non-removable head.10EA
Provide containers, 55-gl, steel, removable head.10EA
Provide containers, 55-gl, poly, non-removable head.5EA
Provide containers, 55-gl, poly, removable head.5EA
Provide container, 5 gal, UN 1H1/Y1.8/100 closed top, plastic, new.10EA
Provide container, 5 gal, UN 1H2/Y30/S open screw-top plastic pail with locking lid, new.10EA
Provide container, 15 gal, UN 1H2/Y100/S open head, plastic, new.10EA
Provide container, 15 gal, UN 1H1/Y closed head, plastic, new.10EA
Provide container, 55 gal, 1A2, open top, steel, reconditioned.5EA
Provide container, 55 gal, 1H1, closed top, plastic, reconditioned.2EA
Provide container, 55 gal, UN 1H2/Y open top, plastic, new.1EA
Provide container, 55 gal, UN 1H1/Y closed top, plastic, new.1EA
Provide container, 55 gal, UN 1A2/Y open top steel with epoxy phenolic lining, new.1EA
Provide container, 55 gal, UN 1A1/Y closed top steel with epoxy phenolic lining, new.1EA
Provide container, 30 gal, 1H1, closed top, plastic, reconditioned.1EA
Provide container, 30 gal. UN 1H2/Y open top, plastic, new.1EA
Provide container, 30 gal, UN 1H1/Y closed top, plastic, new.5EA
Provide container, 30 gal, UN 1A1/Y open top, steel with epoxy phenolic lining, new.0EA
Provide container, 30 gal, UN 1A2/Y closed top, steel with epoxy phenolic lining, new.0EA
Provide container, 55 gal, open top, plastic, reconditioned.5EA
Provide container, 55 gal, 1A1, closed top, steel, reconditioned.1EA
Provide container, 55 gal, 1A2, open top, steel, reconditioned.1EA
Provide container, 55 gal, 1H1, closed top, plastic, reconditioned.20EA
Provide container, 55 gal, UN 1H2/Y open top, plastic, new.20EA
Provide container, 55 gal, UN 1H1/Y closed top, plastic, new.20EA
Provide container, 55 gal, UN 1A2/Y open top steel with epoxy phenolic lining, new.20EA
Provide container, 55 gal, UN 1A1/Y closed top steel with epoxy phenolic lining, new.20EA
Provide container, 85 gal UN1A2/X435/S, UN1A2T/Y320/S removable head (dual rated liquid/solid) steel with epoxy phenolic lining, new.2EA
Provide container, 85 gal UN1H2/X435/S, UN1H2T/Y320/S removable head (dual rated liquid/solid) plastic, new.2EA
Provide Lamp Recycling Box, 48" x 40" x 36" triple wall gaylord box with top and bottom, capacity 500.5EA
Provide hazmat sorbent, 1 EA = 1 x 20 LB bag of Clay Dry Sweep.100EA
Provide container, 8ft fiber fluorescent light tube (capacity 70) UN 1G/Y50/S.25EA
Provide container, 4ft fiber fluorescent light tube (capacity 85) UN 1G/Y50/S.25EA
Provide x20 fluorescent tube drums, 8-ft fiber, UN (1 EA = Qty 20).10EA
Provide x20 fluorescent tube drums, 4-ft fiber, UN 1G/Y50/S (1 EA = Qty 20).10EA
Provide containers, 30-gl, poly, non-removable head.10EA
Provide containers, 15-gl, steel, removable head.0EA
Provide containers, 15-gl, poly, non-removable head.0EA
Provide containers, 5-gl, poly, non-removable head.0EA
Provide containers, 5-gl, poly, removable head.0EA
Provide and prepare lab packs, consisting of small quantity chemicalshr40EA
Expedited removal - 10 days0EA
Expedited removal - 7 days0EA
Expedited removal - 5 days0EA
Expedited removal - 3 days0EA
Expedited removal - 1 day0EA
Expedited performance - 10 days0EA
Expedited performance - 7 days0EA
Expedited performance - 5 days0EA
Expedited performance - 3 days0EA
Expedited performance - 1 day0EA
Perform appropriate analyses to properly identify unknown hazardous waste and complete waste profile5EA
Perform hazardous waste characteristics analysis to determine ignitability (D001), corrosivity (D002), & reactivity (D003) (See 3.3).5EA
Perform total TCLP analysis (D0004-D043) (See 3.3).5EA
Perform TCLP metals analysis to determine 8 RCRA metals (D004-D011) (See 3.3).0EA
Perform TCLP analyses to determine volatile and semivolatile organics (D018-D043) (See3.3).0EA
Perform Total Petroleum Hydrocarbons (TPH) analysis (See 3.3).0EA
Testing unknown compressed gas cylinders.0EA
Perform polychlorinated biphenyl analysis (See 3.3).5EA
Alkaline Batteries, may be managed as Universal Waste (UW) for Recycling or Direct Landfill Disposal.

Physical State: Solid

Permissible Waste Codes: Universal Waste, D002.500LB
Calcium Chromate (CaCrO4) Thermal Batteries, Deactivated, may be managed as UW/HW for Recycling or Destruction & Disposal.

Physical State: Solid

Permissible Waste Codes: Universal Waste, D001 (Oxidizer), D003-11.5LB
Carbon-Zinc (CZn) Batteries, may be managed as UW/HW for Recycling or Disposal.

Physical State: Solid

Permissible Waste Codes: Universal Waste, D002, D004-11.100LB
Lead Acid Batteries,

Physical State: Solid

Permissible Waste Codes: D002, D004-11.800LB
Lithium Ion (Li-Ion) Batteries, may be managed as UW for Recycling/Recovery Only.

Physical State: Solid

Permissible Waste Codes: Universal waste, D002-11.300LB
Lithium Iron Sulfide (Li2FeS2) Thermal Batteries, Deactivated,

Physical State: Solid

Permissible Waste Codes: Universal Waste, D002-11.100LB
Lithium Manganese (LiMn and Oxides thereof) Batteries

Physical State: Solid

Permissible Waste Codes: D002-11.150LB
Lithium Sulfur Dioxide (LiSO2) Batteries,

Physical State: Solid

Permissible Waste Codes: Universal Waste, D002-11.150LB
Lithium Thionyl Chloride (LiSCl) Batteries,

Physical State: Solid

Permissible Waste Codes: Universal Waste, D002-11.500LB
Lithium Batteries, Mixed Types, Deactivated if Applicable

Physical State: Solid

Permissible Waste Codes: Universal Waste, D002-11.500LB
Magnesium (Mg) Batteries, may be managed as UW/HW for Recycling or Destruction and Disposal.

Physical State: Solid

Permissible Waste Codes: Universal Waste, D002, D004-11.100LB
Mercury (Hg) Batteries, may be managed as UW for Recycling/Recovery Only.

Physical State: Solid

Permissible Waste Codes: Universal Waste, D002, D004-11.20LB
Nickel Metal Hydride (NiMh) Batteries,100LB
Nickel-Cadmium (NiCd) Batteries,100LB
Silver-Zinc (AgZn) and Zinc Silver Oxide(ZnAgO) Batteries,10LB
Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, <1% Total Metals, Cr+6 <100 ppm.

Physical State: Liquid

0EA
0EA
0EA
0EA
0EA
Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, >1% Total Metals, Cr+6 <100 ppm.

Physical State: Liquid

0EA
0EA
0EA
0EA
0EA
Corrosive Acids, Inorganic other than HF and HNO3, Concentrated, <1% Total Metals, Cr+6 <100 ppm.

Physical State: Liquid

0EA
0EA
Corrosive Alkalines, Inorganic, <50% in Water, <1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.

Physical State: Liquid

0EA
0EA
0EA
0EA
Corrosive Alkalines, Inorganic, <50% in Water, >1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.

Physical State: Liquid

0EA
Corrosive Organic Acids or Bases, Liquids/Sludges/Solids/Debris, No Ammonia/ Amines, FP ≥ 140°F.

Physical State: Various

0EA
0EA
0EA
0EA
0EA
0EA
Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.

Physical State: Various

0-50EA
6-150EA
16-300EA
31-550EA
Corrosive Aerosols, Non-Flammable.

Physical State: Various

0LB
Cylinders, Acetylene, for Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

Physical State: Comp. Gas

Permissible Waste Codes: D001.3"x12"0EA
4"x24"0EA
12"x36"0EA
16"x56"0EA
Cylinders, Propane, 20-Lb "Grill Size", for Disposal/Recycle/Reuse. Typically 13" x 17". = 1 EA Grill-Size Cylinder.

Physical State: Comp. Gas

Permissible Waste Codes: D001.3EA
Flammable Aerosols, Non-Foaming, No Isocyanates.

Physical State: Various

Permissible Waste Codes: Universal Waste, D001 (IGN), D004-43, Listed.500LB
Flammable Solids/Soils/Debris, Contaminated with Common Solvents, Shreddable, No Free Liquids, No large metal, rock, or masonry components.

Physical State: Solid

Permissible Waste Codes: D001 (IGN), D004-43, Listed.0-520EA
6-150EA
16-300EA
31-550EA
Flammable Liquids/Solids/Sludges/Debris, i.e. tank sludge, lubricants, paint-related waste, adhesives, rags, filters, PPE and non-reactive paint with isocyanates.

Physical State: Various

Permissible Waste Codes: D001-2, D004-43, Listed.0-50EA
6-1510EA
16-3010EA
31-5510EA
Flammable Corrosive Liquids/Solids/Sludges/ Debris/Aerosols.

Physical State: Various

Permissible Waste Codes: D001 (IGN), D002, D004-43, Listed.0-50EA
31-552EA
Oxidizers, Non-Reactive, other than chromic acid (see Corrosives), Liquids/Sludges/Solids/Debris.

Physical State: Various

Permissible Waste Codes: D001(Oxidizer), D002, D004-43, Listed.0-50EA
6-150EA
16-300EA
31-550EA
Paints, Loose-Packed, Latex and/or Oil-Based, and Paint-Related Materials, >2,500 BTU/Lb

Physical State: Various

Permissible Waste Codes: D001 (IGN), D004-43, Listed.0-50EA
6-150EA
16-300EA
31-553EA
Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.

Physical State: Various

Permissible Waste Codes: D002, D004-11, Listed Corrosives.0-55EA
6-150EA
16-300EA
31-551EA
Lab Packs/Loose Packs, Flammables other than Paints.

Physical State: Various

0-52EA
6-152EA
16-302EA
31-555EA
Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, other than paints.

Physical State: Various

Permissible Waste Codes: N/A.0-50EA
6-150EA
16-300EA
31-5510EA
Lab Packs/Loose Packs, Non-Reactive Oxidizers.

Physical State: Various

Permissible Waste Codes: D001 (Oxidizer), D004-11, Listed.0-51EA
6-150EA
16-300EA
31-550EA
Lab Packs/Loose Packs, Reactive Oxidizers, Includes Organic Peroxides, Special Packaging May Be Required.

Physical State: Various

D001 (Oxidizer), D002-11, Listed.0-50EA
6-150EA
16-300EA
31-550EA
Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing, Special Packaging May Be Required.

Physical State: Various

Permissible Waste Codes: D001-43, Listed.0-52EA
6-152EA
16-300EA
31-550EA
Lab Packs/Loose Packs, Toxic Metals.

Physical State: Various

Permissible Waste Codes: D004-11, Listed Inorganics.0-50EA
6-153EA
16-300EA
31-550EA
Lab Packs/Loose Packs, Toxic Organics.

Physical State: Various

Chracteristic and Listed.0-55EA
6-150EA
16-300EA
31-550EA
Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, including pharmaceuticals. Allows for packaging with U-Listed waste.

Physical State: Various

0-55EA
6-150EA
16-300EA
31-550EA
Lab Packs/Loose Packs, Toxic, U-Listed,

Physical State: Various

Permissible Waste Codes: D004-43, U-Listed Codes.0-51EA
6-150EA
16-302EA
31-550EA
Non-RCRA Solids, Direct Landfill Ready (Subtitle D or Equivalent). No Free Liquids. Includes Non-PCB Drained/Dry Transformers, Ballasts, Capacitors, and Related Equipment.

Physical State: Solid

Permissible Waste Codes: N/A.0-50EA
6-150EA
16-300EA
31-550EA
Non-RCRA Solids with Asbestos, Direct Landfill Ready (Subtitle D or Equivalent). Special Packaging Required. No Free Liquids.

Physical State: Solid

Permissible Waste Codes: N/A.0-510EA
31-550EA
pallet0EA
Non-RCRA Sludges/Solids/Debris with Free Liquids. Includes Non-PCB Oil-Filled Transformers, Ballasts, Capacitors and Related Equipment.

Physical State: Various

Permissible Waste Codes: N/A.0-50EA
6-150EA
16-300EA
31-550EA
Non-RCRA Loose-Packed Paints, 100% Water-Based (Latex).

Physical State: Various

Permissible Waste Codes: N/A.0-510EA
6-150EA
16-300EA
31-550EA
Non-RCRA (RCRA-Empty) Containers, Metal, Intact, Recycle or Disposal.

Physical State: Solid

Permissible Waste Codes: N/A.0EA
0EA
0EA
0EA
0EA
Non-RCRA (RCRA-Empty) Containers, Plastic/Poly, Intact, Recycle or Disposal.

Physical State: Solid

Permissible Waste Codes: N/A.0EA
0EA
0EA
0EA
PCB Mineral Oil , Water, Other Fluids, >4,000 ppm PCBs. Certificate of Destruction Required. (See 2.2)

Physical State: Liquid

Permissible Waste Codes: Characteristic, Listed.0LB
PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, >50 ppm PCBs, Non-RCRA, Certificate of Recycling or Destruction Required.

Physical State: Various

Permissible Waste Codes: N/A.20LB
PCB Solids/Debris Contaminated with 1-49 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non-RCRA. (See 2.2)

Physical State: Solid

Permissible Waste Codes: N/A.100LB
PCB Solids/Debris Contaminated with >50 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non-RCRA. Certificate of Disposal, Recycling or Destruction Required. (See 2.2)

Physical State: Solid

Permissible Waste Codes: N/A.20LB
Lamps, Fluorescent, Intact, CFLs, U-Bent, Circulars.

Physical State: Solid

Permissible Waste Codes: Universal Waste, D004-11.800LB
Lamps, Fluorescent, Crushed/Broken, with Filters.

Physical State: Solid

Permissible Waste Codes: Universal Waste, D004-11.0-52EA
6-150EA
16-300EA
Lamps, Halogen.

Physical State: Solid

Permissible Waste Codes: Universal Waste, D004-11.5LB
Lamps, High Intensity Discharge (HID).

Physical State: Solid

Permissible Waste Codes: Universal Waste D004-11.5LB
Lamps, Mercury/Mercury Vapor/LED.

Physical State: Solid

Permissible Waste Codes: Universal Waste D004-11.5LB
Lamps, Metal Halide and Metal Hydride, including Sodium.

Physical State: Solid

Permissible Waste Codes: Universal Waste D003-11.10LB
Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg >260 mg/Kg.

Physical State: Various

Permissible Waste Codes: Universal Waste, D004-11.0-510EA
6-150EA
16-300EA
31-550EA
Antifreeze, Used and Unused for Recycling or Fuels Blending.0-50EA
6-150EA
16-300EA
31-553EA
Used Oil, <10% Water, <1,000 ppm Total Organic Halides. RE11ME refers to 55-gal containers pumped/vacuumed/stung onsite and includes recycling and service.0-51EA
6-150EA
16-300EA
31-5510EA
Used Oil, >10% Water, <1,000 ppm Total Organic Halides. RE12ME refers to 55-gal containers pumped/vacuumed/stung onsite and includes recycling and service.31-550EA
Used Oil Filters, Drained and Undrained, and/Fully Drained Fuel Filters

Physical State: Various

Permissible Waste Codes: UW in some states.0-50EA
6-150EA
16-300EA
31-550EA
56-950EA
Non-PCB Ballasts, Capacitors, Equipment for Recycling. Drained and Undrained. Non-TSCA, Non-RCRA.

Physical State: Various.

Permissible Waste Codes: N/A.150LB
Aerosols, Foaming, Isocyanates or other reactives.

Physical State: Various

Permissible Waste Codes: Universal Waste, D001, D003, D004-43, Listed.5LB
Reactive Metals, i.e. Powders, Dusts, Fines. Air/Water Reactive. Shipped Under Oil and/or Special Packaging may be required.

Physical State: Solid

Permissible Waste Codes: D001, D003, D004-11, Listed.0-50EA
31-550EA
Reactive Metals, Debris. Air/Water Reactive. Shipped Under Oil and/or Special Packaging may be required.

Physical State: Solid

0-50EA
31-550EA
Debris, Inorganic Constituents Only. >50% debris by volume, >60 mm (~2.5") particle size. No free liquids unless incidental rainwater/condensation (See TX20).

Physical State: Debris

0-50EA
6-150EA
16-300EA
31-550EA
56-950EA
Debris, Organic and/or Inorganic Constituents. >50% Debris by volume, >60 mm (~2.5") Particle size. VOCs < 500 ppm. No free liquids unless incidental rainwater/condensation (See TX20).

Physical State: Debris

0-50EA
6-150EA
16-300EA
31-550EA
56-950EA
Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm,0-50EA
6-150EA
16-300EA
31-551EA
56-950EA
Metals-Bearing Liquids, High, >1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm,0-50EA
6-150EA
16-300EA
31-550EA
56-950EA
Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Listed.

Physical State: Various

0-50EA
6-150EA
16-300EA
31-550EA
Metals-Bearing Debris/Solids/Sludges with Free Liquids, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed.

Physical State: Various

0-50EA
31-550EA
pallet0EA
Toxic/Hazardous Solids and Debris Meeting Universal Treatment Standards (UTS). Subtitle C Landfill Ready. No Free Liquids or PCBs.

Physical State: Solid

Permissible Waste Codes: Listed.0-50EA
6-150EA
16-300EA
31-550EA
56-950EA
Base
TotalOption
TotalOption
TotalOption
TotalOption

Total

SP450019D0014 Attachment 1