This Performance Work Statement (PWS) details a renovation project for Building 52 at Altus Air Force Base, Oklahoma. The project involves replacing clerestory windows and ceiling tiles with specific technical requirements. Key scope elements include:
Window Replacement: Install 10 new clerestory windows (8 Type A and 2 Type E) with precise specifications - maximum U-factor of 0.294, maximum Solar Heat Gain Coefficient of 0.175, dark bronze frame color, ¼ inch polycarbonate or laminated glass, and water-tight construction. Ceiling Tile Replacement: Replace five damaged ceiling tiles as identified in Attachment C. The project requires work to be performed in an occupied building, necessitating overhead work safety precautions. All work must comply with local, state, federal, Air Force, and DOD codes, with the contractor responsible for providing labor, materials, equipment, and ensuring no damage to the existing building infrastructure.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 7 - QUESTIONS AND ANSWERS.pdf | ||
| Combined_Synopsis_Solicitation_Bldg 52 Refurb - Final.pdf | ||
| Attachment 6 - Interior Foyer Photos.pdf | ||
| Attachment 4 - Evaluation Factors.pdf | ||
| Attachment 5 - Wage Determination 2015-5329.pdf | ||
| Attachment 2 - Provisions and Clauses.pdf | ||
| Attachment 3 - Instructions to offerers.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AGGN241014 RENOVATE INTERIOR B52
PERFORMANCE WORK STATEMENT
FOR THE RENOVATION OF
B52 INTERIOR
AT
ALTUS AIR FORCE BASE, OKLAHOMA
Project Number:
AGGN241014
Prepared by:
WILLIAM J. SCHWAB
7 March 2025
1. SCOPE:
Providing and installing new clerestory windows and ceiling tiles in Building 52.
2. DESCRIPTION OF WORK:
a. Window types are referenced according to Attachment A page A-27
i. Clerestory has eight (8) Type A and two (2) Type E
b. Replace all clerestory window and frame assemblies with new window and frame assemblies with the following characteristics:
i. Maximum U-factor of 0.294 𝐵𝐵𝐵𝐵𝐵𝐵 ℎ𝑟𝑟∙𝑓𝑓𝐵𝐵2∙°𝐹𝐹
ii. Maximum Solar Heat Gain Coefficient (SHGC) of 0.175
iii. Frame color shall be dark bronze
iv. Interior and exterior trim to conceal gaps and provide transitions
v. New blocking and fasteners
vi. Water-tight construction
vii. Glazed no less than ¼ in. nominal polycarbonate or laminated glass
c. Replace five (5) damaged ceiling tiles shown in Attachment C
3. PROJECT REQUIREMENTS:
a. Building will be occupied, and overhead work safety precautions must be taken to protect occupants
4. GENERAL REQUIREMENTS:
a. All work performed on this project shall meet all local, state, federal, Air Force and
DOD codes.
b. The Government depends on the existing as-built drawings provided by previous
Contractors for the accuracy. The Contractor is advised to field-verify all required information before providing a proposal.
c. The Contractor shall be required to accomplish various other small items of incidental work which may become necessary to complete the project in a satisfactory and workmanlike manner meeting the approval of the contracting officer or their designated representative. The Contractor shall include all such items of work as part of their detailed estimate for the work to be performed.
d. The Contractor shall provide all labor, materials, travel, equipment and supervision necessary to perform all work required for this project.
e. Damage to the building, utilities or any other element during the execution of this project shall be repaired and restored to its original condition by the Contractor provided workers, skilled in trades involved, at no additional cost to Government.
5. ATTACHMENTS:
a. As-builts
b. Window photographs
c. Ceiling tile photographs
END OF PWS
ATTACHMENT A
1611345026C Rectangle
1611345026C Rectangle
ATTACHMENT B
B-1: Clerestory Windows (Identical on both sides)
ATTACHMENT C
C-1: Southwest Ceiling Tile
C-2: Northwest Ceiling Tiles
| PWS 241014 _ Final |
| A-3 Clerestory Plans & Details |
| A-8 Building Elevations & Details |
| A-27 Door Schedule, Window Schedule & Louver Schedule |
| 2025-03-07T15:33:08-0600 | |
| SCHWAB.WILLIAM.J.1611345026 |
File details come from the government source that posted it. Updated .