Attachment 1. Price Schedule SE Regional .xlsx

XLSX spreadsheet 75 KB Posted

Attached to
Southeast Regional HW Incineration Federal contract opportunity
Solicitation number
SP450026R0005
Issued by
Defense Logistics Agency

About this file

This file is a Price Schedule for the Southeastern Regional Hazardous Waste (HW) Incineration Contract, detailing specific service line items (CLINs) and associated pricing for waste disposal services. The pricing schedule covers various waste management services including overpack/loose pack options for containers ranging from 5-gallon pails to 110-gallon drums, special packaging for damaged/defective lithium batteries, certificates of disposal, and hazardous waste profile sheets. The contract includes specific waste categories such as lithium batteries, corrosive acids, oxidizers, and water contaminated with solvents, with estimated quantities for both a 30-month base period and a 30-month option period.

The contract is issued by the Defense Logistics Agency (DLA) and covers waste removal, transportation, incineration, and disposal services for U.S. Department of War and U.S. Coast Guard installations across seven southeastern states: Alabama, Florida, Georgia, Mississippi, North Carolina, South Carolina, and Tennessee. The solicitation (SP450026R0005) is structured as a full and open competition under NAICS code 562211, with a small business size standard of $47 million. The contract is anticipated to run from March 2026 to September 2028, with a base period of 30 months and an optional 30-month extension period.

View the file

Other files for this federal contract opportunity

Other files attached to Southeast Regional HW Incineration, newest first.
File Type Posted
Attachment 2. PWS SE Regional Incin.docx DOCX document
Attachment 4. Additional Contract Terms and Conditions.docx DOCX document
Attachment 6. Addenda to 52.212‐2 Evaluation.docx DOCX document
Attachment 7. PPI Questionnaire_02132025.pdf PDF
Attachment 9. FAR Provision Fill-ins.docx DOCX document
Attachment 10- CAC Application Process.pdf PDF
Attachment 3. Pickup Locations SE Reg HW Incin.xlsx XLSX spreadsheet
Attachment 8-Department of Labor Wage Determination.pdf PDF
Attachment 5. Addenda to 52.212‐1 Instructions Template_Final.docx DOCX document
Attachment 11. Order History.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Price Schedule SE INCIN

PRICE SCHEDULE
Southeastern Regional HW Incineration Contract
SVC or

Base CLIN Service/Waste Description CLIN Est. Qty.

30-Month Base Est. Qty.

30-Month

OptionU/MBase
Unit PriceOption
Unit PriceBase

Extended Price Option Extended Price

1093SVSurcharge for Less Than Minimum Task Order.
One (1) EA will be ordered per TO having a total price for disposal CLINs under $900.00. See 0.0.1093SV11EA$ - 0$ - 0$ - 0$ - 0
1202SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 5-gal pail. See 3.1.1202SV11EA$ - 0$ - 0$ - 0$ - 0
1203SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 15-gal drum. See 3.1.1203SV11EA$ - 0$ - 0$ - 0$ - 0
1204SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 30-gal drum. See 3.1.1204SV11EA$ - 0$ - 0$ - 0$ - 0
1205SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 55-gal drum. See 3.1.1205SV11EA$ - 0$ - 0$ - 0$ - 0
1206SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 110-gal drum. See 3.1.1206SV11EA$ - 0$ - 0$ - 0$ - 0
1207SVLoose Pack smaller container(s) into one Government-provided Cubic Yard Box (CYB) or Military Tri-Wall Box. See 3.1.1207SV11EA$ - 0$ - 0$ - 0$ - 0
1221SVProvide special packaging of DDR Lithium Batteries IAW TSDF acceptance criteria and current DOT regulations. Includes provision of all labor and supplies with outer container size up to 5-gallons. See 2.1 & 3.2.1221SV11EA$ - 0$ - 0$ - 0$ - 0
1300SVPrepare and provide one (1) Certificate of Disposal or Destruction (CD). See 3.3.1300SV11EA$ - 0$ - 0$ - 0$ - 0
1301SVPrepare and provide one (1) Hazardous Waste Profile Sheet (HWPS) or equivalent form. See 3.4.1301SV11EA$ - 0$ - 0$ - 0$ - 0
BA17Batteries, Lithium, Damaged, Defective, or Recalled (DDR), for RCRA incineration. Generator special packaging required. Outer container size up to 55-gal. Managed as UW only if casing isn't breached. See 2.1 & 3.2.

Physical State: Various.

Permissible Waste Codes: D001-8, D009*, D010-43, UW. *See 2.3.BA17C7110110LB$ - 0$ - 0$ - 0$ - 0
CS08Corrosive Acids, Non-Fuming, Hydrofluoric (HF) <40% and/or Nitric (HNO3), <25% in Water.

Physical State: Liquid.

Permissible Waste Codes: D001 (OX), D002. No metals codes.CS08C111EA$ - 0$ - 0$ - 0$ - 0
CS08C411EA$ - 0$ - 0$ - 0$ - 0
CS09Corrosive Acids, Fuming, Hydrofluoric (HF) >40% and/or Nitric (HNO3), ≥25% in Water, may include Red Fuming Nitric Acid (RFNA).

Physical State: Liquid.

Permissible Waste Codes: D001 (OX), D002. No metals codes.CS09C111EA$ - 0$ - 0$ - 0$ - 0
CS09C411EA$ - 0$ - 0$ - 0$ - 0
CS12Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/Sludges/Solids/Debris, Flashpoint ≥140°F.

Physical State: Various.

Permissible Waste Codes: D002, D004-8, D009*, D010-43, Listed. *See 2.3.CS12C11111EA$ - 0$ - 0$ - 0$ - 0
CS12C211EA$ - 0$ - 0$ - 0$ - 0
CS12C311EA$ - 0$ - 0$ - 0$ - 0
CS12C411EA$ - 0$ - 0$ - 0$ - 0
CS12C511EA$ - 0$ - 0$ - 0$ - 0
CS12C611EA$ - 0$ - 0$ - 0$ - 0
CS13Corrosive Organic Acids or Bases, Liquids/Sludges/ Solids/Debris. No Ammonia or Amines. No inorganic acids or bases unless mixed with organic constituents. Flashpoint ≥140°F.

Physical State: Various.

Permissible Waste Codes: D002, D004-8, D009*, D010-43, Listed. *See 2.3.CS13C144EA$ - 0$ - 0$ - 0$ - 0
CS13C211EA$ - 0$ - 0$ - 0$ - 0
CS13C311EA$ - 0$ - 0$ - 0$ - 0
CS13C477EA$ - 0$ - 0$ - 0$ - 0
CS13C511EA$ - 0$ - 0$ - 0$ - 0
CS13C611EA$ - 0$ - 0$ - 0$ - 0
CS15Corrosive Aerosols, Non-Ignitable and Non-Reactive, even when managed as UW.

Physical State: Various.

Permissible Waste Codes: UW, D002, D004-8, D009*, D010-43, Listed. *See 2.3.CS15C711LB$ - 0$ - 0$ - 0$ - 0
FL01Aerosols, Flammable/Combustible/Ignitable, Non-foaming. No isocyanates, reactives, or corrosives, even when managed as UW.

Physical State: Various

Permissible Waste Codes: Universal Waste, D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL01C7486486LB$ - 0$ - 0$ - 0$ - 0
FL02Flammable Debris contaminated with common solvents, shreddable, no free liquids, no large metal, rock, or masonry components.

Physical State: Solid.

Permissible Waste Codes: D001, D004-8, D009*, D010-43, Listed. *See 2.3.FL02C111EA$ - 0$ - 0$ - 0$ - 0
FL02C211EA$ - 0$ - 0$ - 0$ - 0
FL02C311EA$ - 0$ - 0$ - 0$ - 0
FL02C411EA$ - 0$ - 0$ - 0$ - 0
FL02C611EA$ - 0$ - 0$ - 0$ - 0
FL03Flammable Liquids/Solids/Sludges/Debris, e.g., tank sludge, lubricants, adhesives, contaminated rags and other debris. Consists of non-fuels-blendable materials. Use LP03 for loose packs. No paints or coatings eligible for FL16.

Physical State: Various.

Permissible Waste Codes: D001-2, D004-8, D009*, D010-43, Listed. *See 2.3.FL03C11919EA$ - 0$ - 0$ - 0$ - 0
FL03C299EA$ - 0$ - 0$ - 0$ - 0
FL03C31212EA$ - 0$ - 0$ - 0$ - 0
FL03C4125125EA$ - 0$ - 0$ - 0$ - 0
FL03C511EA$ - 0$ - 0$ - 0$ - 0
FL03C655EA$ - 0$ - 0$ - 0$ - 0
FL03T211EA$ - 0$ - 0$ - 0$ - 0
FL04Flammable Corrosive Liquids/Solids/Sludges/ Debris/Aerosols. Use LP03 for loose packs other than aerosols. FL04C7 for use with flammable corrosive aerosols only.

Physical State: Various.

Permissible Waste Codes: UW (Aerosols Only), D001 (IGN), D002, D004-8, D009*, D010-43, Listed. *See 2.3.FL04C11313EA$ - 0$ - 0$ - 0$ - 0
FL04C211EA$ - 0$ - 0$ - 0$ - 0
FL04C3131131EA$ - 0$ - 0$ - 0$ - 0
FL04C41313EA$ - 0$ - 0$ - 0$ - 0
FL04C711LB$ - 0$ - 0$ - 0$ - 0
FL05Flammable Liquids, Pumpable, Fuels Blendable, Rich, >7,000 BTU/Lb, <5% total chlorine. See 2.4.1. No isocyanates or other polymerizable components.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL05C111EA$ - 0$ - 0$ - 0$ - 0
FL05C211EA$ - 0$ - 0$ - 0$ - 0
FL05C311EA$ - 0$ - 0$ - 0$ - 0
FL05C411EA$ - 0$ - 0$ - 0$ - 0
FL05C511EA$ - 0$ - 0$ - 0$ - 0
FL05C611EA$ - 0$ - 0$ - 0$ - 0
FL05T211EA$ - 0$ - 0$ - 0$ - 0
FL06Flammable Liquids, Pumpable, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb, <5% total chlorine, no isocyanates or other polymerizable components.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL06C13737EA$ - 0$ - 0$ - 0$ - 0
FL06C211EA$ - 0$ - 0$ - 0$ - 0
FL06C311EA$ - 0$ - 0$ - 0$ - 0
FL06C41212EA$ - 0$ - 0$ - 0$ - 0
FL06C511EA$ - 0$ - 0$ - 0$ - 0
FL07Flammable Liquids, Pumpable, Fuels Blendable, Lean to Rich, >2,500 BTU/Lb, 5-10% total chlorine, no isocyanates or other polymerizable components.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL07C111EA$ - 0$ - 0$ - 0$ - 0
FL07C211EA$ - 0$ - 0$ - 0$ - 0
FL07C311EA$ - 0$ - 0$ - 0$ - 0
FL07C411EA$ - 0$ - 0$ - 0$ - 0
FL07C511EA$ - 0$ - 0$ - 0$ - 0
FL08Flammable Resuspendable Solids/Sludges, Fuels Blendable, Rich, >7,000 BTU/Lb, <5% total chlorine, no isocyanates or other polymerizable components.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL08C111EA$ - 0$ - 0$ - 0$ - 0
FL08C311EA$ - 0$ - 0$ - 0$ - 0
FL08C411EA$ - 0$ - 0$ - 0$ - 0
FL09Flammable Resuspendable Solids/Sludges, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb, <5% total chlorine, no isocyanates or other polymerizable components.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL09C111EA$ - 0$ - 0$ - 0$ - 0
FL09C411EA$ - 0$ - 0$ - 0$ - 0
FL10Flammable Resuspendable Solids/Sludges, Fuels Blendable, Lean to Rich, greater than 2,500 BTU/Lb, 5-10% total chlorine, no isocyanates or other polymerizable components.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL10C111EA$ - 0$ - 0$ - 0$ - 0
FL10C411EA$ - 0$ - 0$ - 0$ - 0
FL11Flammable Liquids, Highly Chlorinated (>10%), Pumpable, Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed, UW (Pesticides Only). *See 2.3.FL11C111EA$ - 0$ - 0$ - 0$ - 0
FL11C411EA$ - 0$ - 0$ - 0$ - 0
FL12Flammable Solids/Sludges, Highly Chlorinated (>10%), Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed, UW (Pesticides Only). *See 2.3.FL12C111EA$ - 0$ - 0$ - 0$ - 0
FL12C411EA$ - 0$ - 0$ - 0$ - 0
FL13Oxidizers, Non-Reactive, Liquids/Sludges/Solids/ Debris, other than chromic acid (see Corrosives).

Physical State: Various.

Permissible Waste Codes: D001(OX), D002, D004-8, D009*. D010-43, Listed. *See 2.3.FL13C11010EA$ - 0$ - 0$ - 0$ - 0
FL13C266EA$ - 0$ - 0$ - 0$ - 0
FL13C311EA$ - 0$ - 0$ - 0$ - 0
FL13C411EA$ - 0$ - 0$ - 0$ - 0
FL13C566EA$ - 0$ - 0$ - 0$ - 0
FL13C611EA$ - 0$ - 0$ - 0$ - 0
FL15Water Contaminated with Common Solvents, <2,500 BTU/Lb.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL15C111EA$ - 0$ - 0$ - 0$ - 0
FL15C211EA$ - 0$ - 0$ - 0$ - 0
FL15C311EA$ - 0$ - 0$ - 0$ - 0
FL15C411EA$ - 0$ - 0$ - 0$ - 0
FL15C511EA$ - 0$ - 0$ - 0$ - 0
FL15T222EA$ - 0$ - 0$ - 0$ - 0
FL16Non-Reactive paints and other coatings listing isocyanates, amines, or other polymerizable components in the ingredients. Non-fuels-blendable. Use LP16 for loose packs.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL16C111EA$ - 0$ - 0$ - 0$ - 0
FL16C211EA$ - 0$ - 0$ - 0$ - 0
FL16C311EA$ - 0$ - 0$ - 0$ - 0
FL16C411EA$ - 0$ - 0$ - 0$ - 0
FL16C511EA$ - 0$ - 0$ - 0$ - 0
FL16C611EA$ - 0$ - 0$ - 0$ - 0
FL75Flammable Aerosols, paints and paint-related materials, non-foaming, no isocyanates, State-specific Universal Waste (UW).

Physical State: Various.

Permissible Waste Codes: UW.FL75C7990990LB$ - 0$ - 0$ - 0$ - 0
FL77Flammable Liquids, paints and paint-related materials, pumpable, rich, >7,000 BTU/Lb, <5% total chlorine, State-specific Universal Waste (UW).

Physical State: Liquid.

Permissible Waste Codes: UW.FL77C111EA$ - 0$ - 0$ - 0$ - 0
FL77C411EA$ - 0$ - 0$ - 0$ - 0
FL78Flammable Liquids, paints and paint-related wastes, pumpable, lean, 2,500-7,000 BTU/Lb, <5% total chlorine, State-specific Universal Waste (UW).

Physical State: Liquid.

Permissible Waste Codes: UW.FL78C111EA$ - 0$ - 0$ - 0$ - 0
FL78C411EA$ - 0$ - 0$ - 0$ - 0
FL79Flammable Solids/Sludges/Debris, paints and paint-related wastes, FLP <140° F, State-specific Universal Waste (UW).

Physical State: Various.

Permissible Waste Codes: UW.FL79C111EA$ - 0$ - 0$ - 0$ - 0
FL79C411EA$ - 0$ - 0$ - 0$ - 0
FL99Military Items, Demil-required, Flammable Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. for conventional RCRA treatment, disposal. CD required.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D002, D004-8, D009*, D010-43, Listed. *See 2.3.FL99C7174174LB$ - 0$ - 0$ - 0$ - 0
LP01Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.

Physical State: Various.

Permissible Waste Codes: D002, D004-8, D009*, D010-43, Listed Corrosives. *See 2.3.LP01C11616EA$ - 0$ - 0$ - 0$ - 0
LP01C222EA$ - 0$ - 0$ - 0$ - 0
LP01C311EA$ - 0$ - 0$ - 0$ - 0
LP01C422EA$ - 0$ - 0$ - 0$ - 0
LP01C511EA$ - 0$ - 0$ - 0$ - 0
LP01C677EA$ - 0$ - 0$ - 0$ - 0
LP01M111EA$ - 0$ - 0$ - 0$ - 0
LP01M211EA$ - 0$ - 0$ - 0$ - 0
LP03Lap Packs/Loose Packs, Flammables and Flammable Corrosives, including solvent-based products, adhesives, lubricants, etc. No flammable metals. No paint/coating products eligible for LP14 or LP16.

Physical State: Various.

Permissible Waste Codes: D001-2, D004-8, D009*, D010-43, Listed Flammables. *See 2.3.LP03C11717EA$ - 0$ - 0$ - 0$ - 0
LP03C233EA$ - 0$ - 0$ - 0$ - 0
LP03C31212EA$ - 0$ - 0$ - 0$ - 0
LP03C4292292EA$ - 0$ - 0$ - 0$ - 0
LP03C511EA$ - 0$ - 0$ - 0$ - 0
LP03C633EA$ - 0$ - 0$ - 0$ - 0
LP03M111EA$ - 0$ - 0$ - 0$ - 0
LP03M211EA$ - 0$ - 0$ - 0$ - 0
LP04Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, no pharmaceuticals (see LP78). For mandatory RCRA incineration.

Physical State: Various.

Permissible EPA Waste Codes: N/A.LP04C1114114EA$ - 0$ - 0$ - 0$ - 0
LP04C211EA$ - 0$ - 0$ - 0$ - 0
LP04C311EA$ - 0$ - 0$ - 0$ - 0
LP04C41111EA$ - 0$ - 0$ - 0$ - 0
LP04C633EA$ - 0$ - 0$ - 0$ - 0
LP05Lab Packs/Loose Packs, Non-Reactive Oxidizers, for mandatory RCRA incineration.

Physical State: Various.

Permissible Waste Codes: D001 (OX), D002, D004-8, D009*, D010-43, Listed. *See 2.3.LP05C11010EA$ - 0$ - 0$ - 0$ - 0
LP05C222EA$ - 0$ - 0$ - 0$ - 0
LP05C311EA$ - 0$ - 0$ - 0$ - 0
LP05C466EA$ - 0$ - 0$ - 0$ - 0
LP05C611EA$ - 0$ - 0$ - 0$ - 0
LP05M111EA$ - 0$ - 0$ - 0$ - 0
LP05M211EA$ - 0$ - 0$ - 0$ - 0
LP06Lab Packs/Loose Packs, Reactive Oxidizers, including Organic Peroxides, for mandatory RCRA incineration. Special Generator packaging may be required.

Physical State: Various.

Permissible Waste Codes: D001 (OX), D002-8, D009*, D010-43, Listed. *See 2.3.LP06C177EA$ - 0$ - 0$ - 0$ - 0
LP06C211EA$ - 0$ - 0$ - 0$ - 0
LP06C333EA$ - 0$ - 0$ - 0$ - 0
LP06C411EA$ - 0$ - 0$ - 0$ - 0
LP06C511EA$ - 0$ - 0$ - 0$ - 0
LP06C611EA$ - 0$ - 0$ - 0$ - 0
LP06M111EA$ - 0$ - 0$ - 0$ - 0
LP06M211EA$ - 0$ - 0$ - 0$ - 0
LP07Lab Packs/Loose Packs, Reactive Metals, Wet/Dry, includes Broken Sodium Lamps, MRE heaters, E-cigarettes and associated components and residues. Special Generator packaging may be required. May include non-reactive metals. Reactive metals must meet RX08 special packaging requirements.

Physical State: Various.

Permissible Waste Codes: D001, D003-8, D009*, D010-43, Listed. *See 2.3.LP07C144EA$ - 0$ - 0$ - 0$ - 0
LP07C211EA$ - 0$ - 0$ - 0$ - 0
LP07C399EA$ - 0$ - 0$ - 0$ - 0
LP07C411EA$ - 0$ - 0$ - 0$ - 0
LP07C511EA$ - 0$ - 0$ - 0$ - 0
LP07M111EA$ - 0$ - 0$ - 0$ - 0
LP07M211EA$ - 0$ - 0$ - 0$ - 0
LP08Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing, for mandatory RCRA incineration. Special Generator packaging may be required.

Physical State: Various.

Permissible Waste Codes: D001-8, D009*, D010-43, Listed. *See 2.3.LP08C166EA$ - 0$ - 0$ - 0$ - 0
LP08C211EA$ - 0$ - 0$ - 0$ - 0
LP08C311EA$ - 0$ - 0$ - 0$ - 0
LP08C455EA$ - 0$ - 0$ - 0$ - 0
LP08C511EA$ - 0$ - 0$ - 0$ - 0
LP08C611EA$ - 0$ - 0$ - 0$ - 0
LP08M111EA$ - 0$ - 0$ - 0$ - 0
LP08M211EA$ - 0$ - 0$ - 0$ - 0
LP10Lab Packs/Loose Packs, Toxic Organics, for mandatory RCRA incineration.

Physical State: Various.

Permissible Waste Codes: D004-8, D009*, D010-43, Listed. *See 2.3.LP10C199EA$ - 0$ - 0$ - 0$ - 0
LP10C211EA$ - 0$ - 0$ - 0$ - 0
LP10C311EA$ - 0$ - 0$ - 0$ - 0
LP10C411EA$ - 0$ - 0$ - 0$ - 0
LP10C511EA$ - 0$ - 0$ - 0$ - 0
LP10C611EA$ - 0$ - 0$ - 0$ - 0
LP10M111EA$ - 0$ - 0$ - 0$ - 0
LP10M211EA$ - 0$ - 0$ - 0$ - 0
LP11Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, for mandatory RCRA incineration. Includes pharmaceuticals. May be packaged with U-Listed waste.

Physical State: Various.

Permissible Waste Codes: D004-8, D009*, D010-43, P-Listed, U-Listed. *See 2.3.LP11C133EA$ - 0$ - 0$ - 0$ - 0
LP11C211EA$ - 0$ - 0$ - 0$ - 0
LP11C311EA$ - 0$ - 0$ - 0$ - 0
LP11C411EA$ - 0$ - 0$ - 0$ - 0
LP11C511EA$ - 0$ - 0$ - 0$ - 0
LP11M111EA$ - 0$ - 0$ - 0$ - 0
LP11M211EA$ - 0$ - 0$ - 0$ - 0
LP12Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals, for mandatory RCRA incineration.

Physical State: Various.

Permissible Waste Codes: D004-8, D009*, D010-43, U-Listed. *See 2.3.LP12C133EA$ - 0$ - 0$ - 0$ - 0
LP12C211EA$ - 0$ - 0$ - 0$ - 0
LP12C311EA$ - 0$ - 0$ - 0$ - 0
LP12C411EA$ - 0$ - 0$ - 0$ - 0
LP12C511EA$ - 0$ - 0$ - 0$ - 0
LP12C611EA$ - 0$ - 0$ - 0$ - 0
LP12M111EA$ - 0$ - 0$ - 0$ - 0
LP12M211EA$ - 0$ - 0$ - 0$ - 0
LP13Lab Packs/Loose Packs, Pesticides, for mandatory RCRA incineration. See CLIN LP77 for management as UW.

Physical State: Various.

Ermissible Waste Codes: D004-8, D009*, D010-43, U-Listed. *See 2.3.LP13C111EA$ - 0$ - 0$ - 0$ - 0
LP13C411EA$ - 0$ - 0$ - 0$ - 0
LP14Loose-Packed Paints and Paint-Related Materials, Primarily Oil/Petroleum-Based, >7,000 BTU/Lb. May contain incidental Latex paints. No isocyanates or other polymerizable components. Fuels blendable.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.LP14C177EA$ - 0$ - 0$ - 0$ - 0
LP14C211EA$ - 0$ - 0$ - 0$ - 0
LP14C311EA$ - 0$ - 0$ - 0$ - 0
LP14C433EA$ - 0$ - 0$ - 0$ - 0
LP14C511EA$ - 0$ - 0$ - 0$ - 0
LP14C61616EA$ - 0$ - 0$ - 0$ - 0
LP16Loose-Packed Paints. Non-Reactive paints and other coatings listing isocyanates, polymerizable amines, or other polymerizable components in the ingredients. Non-fuels blendable for mandatory incineration.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.LP16C133EA$ - 0$ - 0$ - 0$ - 0
LP16C211EA$ - 0$ - 0$ - 0$ - 0
LP16C311EA$ - 0$ - 0$ - 0$ - 0
LP16C499EA$ - 0$ - 0$ - 0$ - 0
LP16C511EA$ - 0$ - 0$ - 0$ - 0
LP16C622EA$ - 0$ - 0$ - 0$ - 0
LP77Lab Packs/Loose Packs, Pesticides, Managed as UW per 40 CFR 273.3.

Physical State: Various.

Permissible Waste Codes: UW.LP77C111EA$ - 0$ - 0$ - 0$ - 0
LP77C411EA$ - 0$ - 0$ - 0$ - 0
LP78Lab Packs/Loose Packs, Pharmaceuticals, including aerosols, non-RCRA, prescription and non-prescription. No DEA-controlled drugs. For mandatory RCRA Incineration. CD required.

Physical State: Various.

Permissible Waste Codes: N/A.LP78C166EA$ - 0$ - 0$ - 0$ - 0
LP78C211EA$ - 0$ - 0$ - 0$ - 0
LP78C322EA$ - 0$ - 0$ - 0$ - 0
LP78C455EA$ - 0$ - 0$ - 0$ - 0
LP78M111EA$ - 0$ - 0$ - 0$ - 0
LP78M211EA$ - 0$ - 0$ - 0$ - 0
LP79Lab Packs/Loose Packs, Miscellaneous laboratory-related wastes including preserved specimens, microscope slides, etc. No infectious or biohazardous wastes. May require a Non-Biohazardous or Non-Infectious Certificate.

Physical State: Various.

Permissible Waste Codes: N/A.LP79C111EA$ - 0$ - 0$ - 0$ - 0
LP79C211EA$ - 0$ - 0$ - 0$ - 0
LP79C311EA$ - 0$ - 0$ - 0$ - 0
LP79C411EA$ - 0$ - 0$ - 0$ - 0
NR04Non-RCRA Liquids, Organic-Based, pumpable, primarily consisting of wastes containing hydrocarbons.

Physical State: Liquid.

Permissible Waste Codes: N/A.NR04C111EA$ - 0$ - 0$ - 0$ - 0
NR04C411EA$ - 0$ - 0$ - 0$ - 0
NR07Non-RCRA Pharmaceuticals, prescription and non-prescription, for mandatory RCRA incineration. No DEA-restricted meds. Use LP79 for lab packs/loose packs. CD required.

Physical State: Various.

Permissible Waste Codes: N/A.NR07C166EA$ - 0$ - 0$ - 0$ - 0
NR07C211EA$ - 0$ - 0$ - 0$ - 0
NR07C311EA$ - 0$ - 0$ - 0$ - 0
NR07C411EA$ - 0$ - 0$ - 0$ - 0
NR07C611EA$ - 0$ - 0$ - 0$ - 0
NR78Non-RCRA Military Items for Demil, Debris/Liquids/ Solids and Sludge. Includes State Regulated decontaminated Chemical Agent related waste. Non-Flammable, i.e. CDE kits, Vials, filters, PPE, etc. for mandatory incineration. CD required.

Physical State: Various.

Permissible Waste Codes: N/A.NR78C111EA$ - 0$ - 0$ - 0$ - 0
NR78C211EA$ - 0$ - 0$ - 0$ - 0
NR78C311EA$ - 0$ - 0$ - 0$ - 0
NR78C411EA$ - 0$ - 0$ - 0$ - 0
NR78C611EA$ - 0$ - 0$ - 0$ - 0
NR96Non-RCRA Liquids for RCRA Incineration, pumpable. Not used for AFFF or other PFAS-related wastes. CD required.

Physical State: Liquid.

Permissible Waste Codes: N/A.NR96C111EA$ - 0$ - 0$ - 0$ - 0
NR96C211EA$ - 0$ - 0$ - 0$ - 0
NR96C311EA$ - 0$ - 0$ - 0$ - 0
NR96C411EA$ - 0$ - 0$ - 0$ - 0
NR96C611EA$ - 0$ - 0$ - 0$ - 0
NR97Non-RCRA Solids/Sludges/Debris for RCRA Incineration. May contain some free liquids. Not used for AFFF or other PFAS-related wastes. CD required.

Physical State: Various.

Permissible Waste Codes: N/A.NR97C11616EA$ - 0$ - 0$ - 0$ - 0
NR97C211EA$ - 0$ - 0$ - 0$ - 0
NR97C311EA$ - 0$ - 0$ - 0$ - 0
NR97C466EA$ - 0$ - 0$ - 0$ - 0
NR97C611EA$ - 0$ - 0$ - 0$ - 0
PC01PCB wastes containing or contaminated with at least a 50 ppm source (5 ppm in CA, 2 ppm in WA), RCRA or Non-RCRA, e.g., fluids, soil, sludge, debris, leaking capacitors. CD required. See 2.2.

Physical State: Various.

Permissible Waste Codes: D001-8, D010-43, Listed.PC01C8303303KG$ - 0$ - 0$ - 0$ - 0
PC03PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs (5-4,000 ppm in CA, 2-4,000 ppm in WA). Non-RCRA, CD required. See 2.2.

Physical State: Liquid.

Permissible Waste Codes: N/A.PC03C855KG$ - 0$ - 0$ - 0$ - 0
PC04PCB Mineral Oil, Water, Other Fluids, more than 4,000 ppm PCBs. RCRA or Non-RCRA. CD required. See 2.2.

Physical State: Liquid.

Permissible Waste Codes: D001-8, D010-43, Listed.PC04C855KG$ - 0$ - 0$ - 0$ - 0
PC06PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, at least 50 ppm PCBs (5 ppm in CA, 2 ppm in WA), Non-RCRA, CD required. See 2.2.

Physical State: Various.

Permissible Waste Codes: N/A.PC06C855KG$ - 0$ - 0$ - 0$ - 0
PC08PCB Oil-Filled Transformers, at least 50 ppm PCBs (5 ppm in CA, 2 ppm in WA). CD required. See 2.2.

Physical State: Various.

Permissible Waste Codes: N/A.PC08C855KG$ - 0$ - 0$ - 0$ - 0
PC10PCB Solids/Debris Contaminated with at least a 50 ppm Source (5 ppm in CA, 2 ppm in WA), e.g., soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers. No Free Liquids. Non-RCRA. CD required. See 2.2.

Physical State: Solid.

Permissible Waste Codes: N/A.PC10C8143143KG$ - 0$ - 0$ - 0$ - 0
PF10PFAS-containing Liquids/Solids/Sludges/Debris, Flammable/Combustible/Ignitable, for RCRA incineration.

Physical State: Various.

Permissible Waste Codes: D001, D002, D004-8, D009*, D010-43, Listed. *See 2.3.PF10C111EA$ - 0$ - 0$ - 0$ - 0
PF10C411EA$ - 0$ - 0$ - 0$ - 0
PF11PFAS-containing Liquids/Solids/Sludges/Debris, Corrosive, for RCRA incineration. CD required.

Physical State: Various.

Permissible Waste Codes: D002, D004-8, D009*, D010-43, Listed. *See 2.3.PF11C111EA$ - 0$ - 0$ - 0$ - 0
PF11C411EA$ - 0$ - 0$ - 0$ - 0
PF12PFAS-containing Liquids/Solids/Sludges/Debris, Reactive, for RCRA incineration. CD required.

Physical State: Various.

Permissible Waste Codes: D001-8, D009*, D010-43, Listed. *See 2.3.PF12C111EA$ - 0$ - 0$ - 0$ - 0
PF12C411EA$ - 0$ - 0$ - 0$ - 0
PF13PFAS-containing Liquids/Solids/Sludges/Debris, Toxic, for RCRA incineration. CD required.

Physical State: Various.

Permissible EPA Waste Codes: D004-8, D009*, D010-43, Listed. *See 2.3.PF13C111EA$ - 0$ - 0$ - 0$ - 0
PF13C411EA$ - 0$ - 0$ - 0$ - 0
PF20PFAS and AFFF-impacted solids, sludges, and debris, e.g., spill-related solids, soil, gravel, filter media, tank bladders, etc. Non-RCRA, for RCRA incineration. May contain some free liquids.

Physical State: Various.

Permissible Waste Codes: N/A.PF20C111EA$ - 0$ - 0$ - 0$ - 0
PF20C221EA$ - 0$ - 0$ - 0$ - 0
PF20C311EA$ - 0$ - 0$ - 0$ - 0
PF20C42814EA$ - 0$ - 0$ - 0$ - 0
PF20C511EA$ - 0$ - 0$ - 0$ - 0
PF20C6115EA$ - 0$ - 0$ - 0$ - 0
PF21PFAS and AFFF high-concentrate liquids, pumpable, Non-RCRA, for RCRA incineration. Unused or more than 10% product by volume.

Physical State: Liquid.

Permissible Waste Codes: N/A.PF21C1537EA$ - 0$ - 0$ - 0$ - 0
PF21C211EA$ - 0$ - 0$ - 0$ - 0
PF21C321EA$ - 0$ - 0$ - 0$ - 0
PF21C461EA$ - 0$ - 0$ - 0$ - 0
PF21C511EA$ - 0$ - 0$ - 0$ - 0
PF21T111EA$ - 0$ - 0$ - 0$ - 0
PF21T2246EA$ - 0$ - 0$ - 0$ - 0
PF21T311EA$ - 0$ - 0$ - 0$ - 0
PF22PFAS and AFFF rinsates and other impacted waters, pumpable, Non-RCRA, for RCRA incineration. At least 90% water by volume.

Physical State: Liquid.

Permissible Waste Codes: N/A.PF22C192EA$ - 0$ - 0$ - 0$ - 0
PF22C221EA$ - 0$ - 0$ - 0$ - 0
PF22C361EA$ - 0$ - 0$ - 0$ - 0
PF22C410223EA$ - 0$ - 0$ - 0$ - 0
PF22C511EA$ - 0$ - 0$ - 0$ - 0
PF22T111EA$ - 0$ - 0$ - 0$ - 0
PF22T24827EA$ - 0$ - 0$ - 0$ - 0
PF22T311EA$ - 0$ - 0$ - 0$ - 0
RX01Aerosols, Foaming, Isocyanates or other reactives.

Physical State: Various.

Permissible Waste Codes: UW, D001-8, D009*, D010-43, Listed. *See 2.3.RX01C72,5702,570LB$ - 0$ - 0$ - 0$ - 0
RX02Cyanide, >50% Debris, >590 mg/Kg Total CN.

Physical State: Various.

Permissible Waste Codes: D002-8, D009*, D010-43, Listed. *See 2.3.RX02C111EA$ - 0$ - 0$ - 0$ - 0
RX02C411EA$ - 0$ - 0$ - 0$ - 0
RX03Cyanide Liquids, Solids, <50% Debris, 590-10,000 mg/Kg (1%) Total CN.

Physical State: Various.

Permissible Waste Codes: D002-8, D009*, D010-43, Listed. *See 2.3.RX03C111EA$ - 0$ - 0$ - 0$ - 0
RX03C411EA$ - 0$ - 0$ - 0$ - 0
RX04Cyanide Liquids, Solids, <50% Debris, 1%-10% Total CN.

Physical State: Various.

Permissible Waste Codes: D002-8, D009*, D010-43, Listed. *See 2.3.RX04C111EA$ - 0$ - 0$ - 0$ - 0
RX04C411EA$ - 0$ - 0$ - 0$ - 0
RX05Cyanide Liquids, Solids, <50% Debris, >10% Total CN.

Physical State: Various.

Permissible Waste Codes: D002-8, D009*, D010-43, Listed. *See 2.3.RX05C111EA$ - 0$ - 0$ - 0$ - 0
RX05C411EA$ - 0$ - 0$ - 0$ - 0
RX06Reactive Oxidizers, e.g., Nitrates, Nitrites, Persulfates, Inorganic Peroxides, No Organic Peroxides. Special Generator packaging may be required.

Physical State: Various.

Permissible Waste Codes: D001-8, D009*, D010-43, Listed. *See 2.3.RX06C13636EA$ - 0$ - 0$ - 0$ - 0
RX06C211EA$ - 0$ - 0$ - 0$ - 0
RX06C311EA$ - 0$ - 0$ - 0$ - 0
RX06C43232EA$ - 0$ - 0$ - 0$ - 0
RX07Polymerizing Materials, e.g, Styrene, Isocyanates, Acrylates, etc. Special Generator packaging may be required.

Physical State: Various.

Permissible Waste Codes: D001-8, D009*, D010-43, Listed. *See 2.3.RX07C111EA$ - 0$ - 0$ - 0$ - 0
RX07C211EA$ - 0$ - 0$ - 0$ - 0
RX07C322EA$ - 0$ - 0$ - 0$ - 0
RX07C422EA$ - 0$ - 0$ - 0$ - 0
RX08Reactive Metals, powders, dusts, fines. Air/Water Reactive. Special Generator packaging required. See 1.2.3.

Physical State: Solid.

Permissible Waste Codes: D001-8, D009*, D010-43, Listed. *See 2.3.RX08C166EA$ - 0$ - 0$ - 0$ - 0
RX08C211EA$ - 0$ - 0$ - 0$ - 0
RX08C3137137EA$ - 0$ - 0$ - 0$ - 0
RX08C466EA$ - 0$ - 0$ - 0$ - 0
RX09Reactive Metals, debris. Air/Water Reactive. Special Generator packaging required. See 1.2.3.

Physical State: Solid.

Permissible Waste Codes: D001-8, D009*, D010-11, Listed. *See 2.3.RX09C111EA$ - 0$ - 0$ - 0$ - 0
RX09C211EA$ - 0$ - 0$ - 0$ - 0
RX09C311EA$ - 0$ - 0$ - 0$ - 0
RX09C411EA$ - 0$ - 0$ - 0$ - 0
RX10Reactive Non-Metals, e.g., P-Coded, Temperature Sensitive, PIHs, Air/Water Reactive. Special Generator packaging required.

Physical State: Solid.

Permissible Waste Codes: D001-8, D009*, D010-11, Listed. *See 2.3.RX10C111EA$ - 0$ - 0$ - 0$ - 0
RX10C211EA$ - 0$ - 0$ - 0$ - 0
RX10C311EA$ - 0$ - 0$ - 0$ - 0
RX10C411EA$ - 0$ - 0$ - 0$ - 0
RX95Reactive, Ignitable, and Toxic Solids, Sludges, and Debris, for RCRA Incineration. Contaminated w/ Mineral Spirits, Motor Oil, Alcohol, Solvents, Otto Fuel. <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals.

Physical State: Various.

Permissible Waste Codes: D001-8, D009*, D010-11, Listed. *See 2.3.RX95C111EA$ - 0$ - 0$ - 0$ - 0
RX96Reactive Electron Tubes for Demil and Disposal, Water Reactive, Intact, Contains Non-Radioactive Cesium. CD required.

Physical State" Solid

Permissible Waste Codes: D001-8, D009*, D010-43, Listed. *See 2.3.RX96C71010LB$ - 0$ - 0$ - 0$ - 0
RX97Reactive, Ignitable, and Toxic Liquid for RCRA incineration. Contains Water, Mineral Spirits, Motor Oil, <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals.

Physical State: Liquid.

Permissible Waste Codes: D001, D003-8, D009*, D010-43, Listed. *See 2.3.RX97C111EA$ - 0$ - 0$ - 0$ - 0
RX97C411EA$ - 0$ - 0$ - 0$ - 0
RX97T211EA$ - 0$ - 0$ - 0$ - 0
RX99Reactive, Military Items, Demil-Required, Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. (No Batteries) for RCRA incineration. Generator special packaging may be required. Must Carry D003. CD required.

Physical State: Various.

Permissible Waste Codes: D001-8, D010-D043, Listed. *See 2.3.RX99C111EA$ - 0$ - 0$ - 0$ - 0
RX99C211EA$ - 0$ - 0$ - 0$ - 0
RX99C311EA$ - 0$ - 0$ - 0$ - 0
RX99C411EA$ - 0$ - 0$ - 0$ - 0
TX07Toxic, Debris, Organic Constituents. Must include organic Waste Code(s). May include inorganic Waste Code(s) and/or RCRA hazardous asbestos.

Physical State: Debris.

Permissible Waste Codes: D004-8, D009*, D010-43, Listed, but no F020-32. *See 2.3.TX07C111EA$ - 0$ - 0$ - 0$ - 0
TX07C211EA$ - 0$ - 0$ - 0$ - 0
TX07C311EA$ - 0$ - 0$ - 0$ - 0
TX07C41010EA$ - 0$ - 0$ - 0$ - 0
TX07C511EA$ - 0$ - 0$ - 0$ - 0
TX07C633EA$ - 0$ - 0$ - 0$ - 0
TX09Toxic, High Halogen Liquids/Sludges/Solids/Debris, Non-Flammable, Includes Solvents, Herbicides and Pesticides.

Physical State: Various.

Permissible Waste Codes: UW, D004-8, D009*, D010-43, Listed. *See 2.3.TX09C111EA$ - 0$ - 0$ - 0$ - 0
TX09C211EA$ - 0$ - 0$ - 0$ - 0
TX09C311EA$ - 0$ - 0$ - 0$ - 0
TX09C433EA$ - 0$ - 0$ - 0$ - 0
TX09C511EA$ - 0$ - 0$ - 0$ - 0
TX21Toxic Organics Contaminated Water, Pumpable, <10% Suspended Solids, <10% Organics, e.g., Toluene, Phenol in water. Not more toxic than common solvents.

Physical State: Liquid.

Permissible Waste Codes: D004-8, D009*, D010-43, Listed. *See 2.3.TX21C111EA$ - 0$ - 0$ - 0$ - 0
TX21C211EA$ - 0$ - 0$ - 0$ - 0
TX21C311EA$ - 0$ - 0$ - 0$ - 0
TX21C411EA$ - 0$ - 0$ - 0$ - 0
TX21T211EA$ - 0$ - 0$ - 0$ - 0
TX22Toxic Organics in Solids/Sludges/Debris, i.e. soil, tank & still bottoms, adhesives, filtercake. Not more toxic than common solvents.

Physical State: Various.

Permissible Waste Codes: D004-8, D009*, D010-43, Listed. *See 2.3.TX22C133EA$ - 0$ - 0$ - 0$ - 0
TX22C211EA$ - 0$ - 0$ - 0$ - 0
TX22C311EA$ - 0$ - 0$ - 0$ - 0
TX22C444EA$ - 0$ - 0$ - 0$ - 0
TX22C666EA$ - 0$ - 0$ - 0$ - 0
TX24Toxic Organic Solvents, Technical grade, pure or mixed solutions, with or without water and/or metals, Flashpoint >140°F.

Physical State: Various.

Permissible Waste Codes: D004-8, D009*, D010-43, Listed. *See 2.3.TX24C111EA$ - 0$ - 0$ - 0$ - 0
TX24C211EA$ - 0$ - 0$ - 0$ - 0
TX24C311EA$ - 0$ - 0$ - 0$ - 0
TX24C411EA$ - 0$ - 0$ - 0$ - 0
TX98Toxic, Military Items, Demil-required, RCRA Toxic, e.g., CDE Kits, Tents, Filters, PPE, etc. for RCRA incineration. CD required.

Physical State: Various.

Permissible Waste Codes: D004-8, D009*, D010-43, Listed. *See 2.3.TX98C71010LB$ - 0$ - 0$ - 0$ - 0
TX99Submarine and Special Hull Treatment tiles. Demil-required via RCRA Incineration. For use even when no toxic EPA Waste Codes apply. Not for bulk removals. Restricted transportation requirements apply. See 2.5.1. Generator(s) must acquire written authorization from their Command Leadership to utilize this CLIN. Certificate of Destruction required.

Physical State: Solid.

Permissible Waste Codes: D004-8, D009*, D010-43. *See 2.3.TX99C7500500LB$ - 0$ - 0$ - 0$ - 0
$ - 0$ - 0

CLIN Suffixes Table

CLIN Suffix Table
Containerized Wastes
CLIN Suffix→C1C2C3C4
Container Size/Type:Up to 5 Gal
(DM/DF)Up to 15 Gal
(DM/DF)Up to 30 Gal
(DM/DF)Up to 55 Gal

(DM/DF)

Unit of Issue:EAEAEAEA
CLIN Suffix→C5C6C7C8
Container Size/Type:Up to 110 Gal
(DM/DF)CYB, TRIWALL or PALLETContainerized PoundsContainerized Kilograms
Unit of Issue:EAEALBKG
Pumpable Liquid Wastes Removed in Totes / IBCs
CLIN Suffix→T1T2T3
Container Size:
Type:Up to 220 GL
(TP)Up to 275 GL
(TP)Up to 330 GL

(TP)

Unit of Issue: EA EA EA

Special Laboratory Container Sizes
CLIN Suffix→MEM1M2M3
Container Size:1.25 Gal2.5 Gal
Type:(DM/DF)(DM/DF)
Unit of Issue:EAEA

File details come from the government source that posted it. Updated .