This document contains a combined synopsis and solicitation for a 16 Channel 100W S-Band High-Power Amplifier Shelf. The Naval Research Laboratory seeks delivery of the shelf no later than 12 months from award to support research and development activities. The shelf must contain 16 channels that each amplify a 1mW RF input signal to 100W, operate within the 3.1-3.5GHz range, and meet various gain, power, pulse, and harmonic specifications. Control circuitry is required for monitoring health and operation. The unit will be housed in a standard 19-inch rack and incorporate RF input and output connectors. Vendors must demonstrate experience producing similar high-power solid-state transmitters. Offers are due by December 19, 2022 for consideration under the firm fixed-price contract to be awarded.

View the file

Other files

File Type Posted
COMBINED SYNOPSIS N00173-23-R-MR01.docx DOCX document
Attachment 2 - Requirements for On-Site Contractors.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PR# 1301007085

16 Channel 100W S-Band HPAs Shelf Specifications

· Number of RF channels: 16 (minimum)

· Operating Frequency: range must include 3.1-3.5 GHz

· Amplifier class: AB, must permit linear or saturated operation

· RF input for saturated operation: 0 dBm

· Power per channel: 100W (minimum)

· Power gain variation: 2dB peak-to-peak (maximum)

· Duty Cycle: 50% (minimum)

· Pulse width: range must include 1-100 us

· Pulse repetition frequency: 100kHz (minimum)

· Pulse droop: 1dB over 100 us (maximum)

· Pulse rise/fall time: 200 ns (maximum)

· Harmonics power level: -30dBc (maximum)

· Non-harmonic spurious power: -70dBc within 20kHz of carrier, -55dBc beyond (maximum)

· VSWR: 2.0:1 over entire band (maximum)

· Power supply input voltage: 120 VAC, 240 VAC, or 208VAC 3-phase

· Operating temperature: range must include -20 to +40 deg C

· Operating humidity: up to 95% RH

· Cooling: air cooled

· Form factor: 19 inch rack-mount, 8U (maximum). May be split into multiple chassis.

· Output couplers for monitoring and calibration: -30 to -60dB

· RF Input connectors: SMA

· RF Output connectors: N-type

· RF output coupled-port connectors: SMA

Pulse circuit for all channels shall be controlled by a common LVTTL gate input aligned with RF pulse. When gate is low, there shall be no significant output above thermal noise after fall-time.

Unit should have control/monitoring interface accessible by one or more of ethernet/USB/serial which includes at a minimum:

· Individual channel enable/disable

· Monitoring of faults: power supply, over-duty, over-pulsewidth, over-temp

· Status monitoring: temperature, per-channel output level, fan RPM