8.3 Compartmentation.

The telecommunications facility shall be separated from other occupancies within the building by fire‐resistance‐rated construction, which is commensurate with the exposure but not less than 1 hour.

8.3.2.1 Doors.

Doors shall be fire tested under positive pressure to NFPA 252 and shall be installed in accordance with NFPA 80.

8.3.2.1.1 The fire rating of the door assemblies shall correspond to the fire rating of the partition assemblies as follows:

(1) One‐hour partition shall have 1‐hour fire‐resistance‐rated door assembly.

(2) Two‐hour partition shall have 1 ½ ‐hour fire‐resistance‐rated door assembly.

(3) Three‐hour partition shall have 3‐hour fire‐resistance‐rated door assembly.

VOLTAGE FLA MCA

MOCP

A/POLE CONDUIT SWITCH DISCONNECT AT UNIT CIRCUIT

CONNECTION

NOTES

IU 3-1 208V, 1 PHASE .28 A (2) #12 THWN & (1) #12 GND 3/4" 1

OU 3-1 208V, 1 PHASE 11A 15/1 (2) #10 THWN & (1) #10 GND 3/4" 30A, 3-POLE, NONFUSED, WP 11-3-PP-6, 22/24 1

CONNECTION NOTES:

MECHANICAL ELECTRICAL CONNECTION SCHEDULE

VERIFY EXACT OVER CURRENT PROTECTION/DISCONNECT REQUIREMENTS (PER N.E.C. #440) WITH EQUIPMENT MANUFACTURER NAMEPLATE DATA UPON RECEIPT AT JOB SITE. CONTACT ENGINEER WITH ANY DISCREPANCIES. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL ELECTRICAL POWER CONNECT

1. INSTALL MOTOR RATED TOGGLE/LOCKABLE SWITCH AT EACH UNIT LOCATION FOR LOCAL DISCONNECTING MEANS.

UNIT GROUNDED AND UNGROUNDED

CONDUCTORS

NOTE:

A/POLE CONDUIT SWITCH DISCONNECT AT UNIT CIRCUIT

CONNECTION

NOTES

AC 11-6-1 120V, 1 PHASE 8.00 A 10.00 A 15/1 (2) #12 THWN & (1) #12 GND 3/4" 1P MOTOR RATED TOGGLE SWITCH 11-6-PP-1, 11 1

CONNECTION NOTES:

MECHANICAL ELECTRICAL CONNECTION SCHEDULE

VERIFY EXACT OVER CURRENT PROTECTION/DISCONNECT REQUIREMENTS (PER N.E.C. #440) WITH EQUIPMENT MANUFACTURER NAMEPLATE DATA UPON RECEIPT AT JOB SITE. CONTACT ENGINEER WITH ANY DISCREPANCIES. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL ELECTRICAL POWER CONNECT

1. INSTALL MOTOR RATED TOGGLE/LOCKABLE SWITCH AT EACH UNIT LOCATION FOR LOCAL DISCONNECTING MEANS.

UNIT GROUNDED AND UNGROUNDED

A/POLE CONDUIT SWITCH DISCONNECT AT UNIT CIRCUIT

CONNECTION

NOTES

IU 7-1 208V, 1 PHASE .28 A (2) #12 THWN & (1) #12 GND 3/4" 1

OU 7-1 208V, 1 PHASE 11A 15/1 (2) #10 THWN & (1) #10 GND 3/4" 30A, 3-POLE, NONFUSED, WP 11-7-PP-1, 29/31 1

CONNECTION NOTES:

MECHANICAL ELECTRICAL CONNECTION SCHEDULE

VERIFY EXACT OVER CURRENT PROTECTION/DISCONNECT REQUIREMENTS (PER N.E.C. #440) WITH EQUIPMENT MANUFACTURER NAMEPLATE DATA UPON RECEIPT AT JOB SITE. CONTACT ENGINEER WITH ANY DISCREPANCIES. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL ELECTRICAL POWER CONNECT

1. INSTALL MOTOR RATED TOGGLE/LOCKABLE SWITCH AT EACH UNIT LOCATION FOR LOCAL DISCONNECTING MEANS.

UNIT GROUNDED AND UNGROUNDED

A/POLE CONDUIT SWITCH DISCONNECT AT UNIT CIRCUIT

CONNECTION

NOTES

IU 9-1 208V, 1 PHASE .28 A (2) #12 THWN & (1) #12 GND 3/4" 1

OU 9-1 208V, 1 PHASE 11A 15/1 (2) #10 THWN & (1) #10 GND 3/4" 30A, 3-POLE, NONFUSED, WP 11-9-LP-1, 12/14 1

CONNECTION NOTES:

MECHANICAL ELECTRICAL CONNECTION SCHEDULE

VERIFY EXACT OVER CURRENT PROTECTION/DISCONNECT REQUIREMENTS (PER N.E.C. #440) WITH EQUIPMENT MANUFACTURER NAMEPLATE DATA UPON RECEIPT AT JOB SITE. CONTACT ENGINEER WITH ANY DISCREPANCIES. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL ELECTRICAL POWER CONNECT

1. INSTALL MOTOR RATED TOGGLE/LOCKABLE SWITCH AT EACH UNIT LOCATION FOR LOCAL DISCONNECTING MEANS.

UNIT GROUNDED AND UNGROUNDED

SHT 1 OF 21 - 3-1711 G-001 - COVER SHEET.pdf
SHT 2 OF 22 - 3-1711 G-002 - GENERAL NOTES.pdf
SHT 3 OF 21 - 3-1711 A-101 - LOCATION MAP.pdf
SHT 4 OF 21 - 3-1711 A-102 - DEMOLITION PLAN - SECT. 3 & 6.pdf
SHT 5 OF 21 - 3-1711 A-103 - DEMOLITION PLAN - SECT. 7 & 9.pdf
SHT 6 OF 21 - 3-1711 A-104 - NEW WORK PLAN - SECT. 3 & 6.pdf
SHT 7 OF 21 - 3-1711 A-105 - NEW WORK PLAN - SECT. 7 & 9.pdf
SHT 8 OF 21 - 3-1711 A-106 - DOOR SCHEDULE.pdf
SHT 9 OF 21 - 3-1711 A-107 - DETAILS.pdf
SHT 10 OF 21 - 3-1711 A-108 - BUILDING 11 SECTION 3 & 6 RCP.pdf
SHT 11 OF 21 - 3-1711 A-109 - BUILDING 11 SECTION 7 & 9 RCP.pdf
SHT 12 OF 21 - 3-1711 EP-101 - POWER PLAN 11-3.pdf
SHT 13 OF 21 - 3-1711 EP-102 - POWER PLAN 11-6.pdf
SHT 14 OF 21 - 3-1711 EP-103 - POWER PLAN 11-7.pdf
SHT 15 OF 21 - 3-1711 EP-104 - POWER PLAN 11-9.pdf
SHT 16 OF 21 - 3-1711 M-101 - NEW MECHANICAL WORK PLAN 11-3.pdf
SHT 17 OF 21 - 3-1711 M-102 - NEW MECHANICAL WORK PLAN 11-6.pdf
SHT 18 OF 21 - 3-1711 M-103 - NEW HVAC WORK PLAN 11-7.pdf
SHT 19 OF 21 - 3-1711 M-104 - NEW MECHANICAL WORK PLAN 11-9.pdf
SHT 20 OF 21 - 3-1711 M-501 - MECHANICAL WORK DETAILS.pdf
SHT 21 OF 21 - 3-1711 M-601 - MECHANICAL WORK SCHEDULES.pdf