Attachment 01 SOW_6973GH-25-R-00093_USFS GUY TENSIONING GOLDEN POND.pdf

PDF 9 MB Posted

Attached to
6973GH-25-R-00093 - USFS GUY TENSIONING GOLDEN POND - SIR
Solicitation number
6973GH-25-R-00093
Issued by

About this file

This Statement of Work (SOW) details requirements for remediation services for U.S. Forest Service Guy Towers across three locations: Winona Repeater, Golden Pond Repeater, and Cass Repeater. The project involves implementing guy system tensioning, minor guy system repairs, and new grounding installations on guyed lattice-based communication, fire watch/lookout, and research towers. Specific requirements include: tension guy wires to specified standards, perform corrosion abatement on guy wire anchors, install safety wires, install waterfall ground leads, bond anchor shafts, and apply corrosion-resistant coatings following SSPC (Steel Structure Painting Council) standards.

The SOW specifies site-specific requirements for each location, such as inspecting guy anchor shafts, installing ground rods, and addressing environmental and structural conditions. The contractor must provide all necessary tools, equipment, materials, and technical expertise. The project is expected to be completed within 30 days of start, with a remediation plan and final schedule to be submitted two weeks prior to work commencement. The primary federal agencies involved are the U.S. Forest Service and the Federal Aviation Administration (FAA), with the contract aimed at sustaining the health and functionality of forest communication infrastructure.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK (SOW)

Remediation

For

U.S. Forest Service Guy Towers

PREPARATION DATE: 10/03/2024

AJW-L533 / United States Forest Service

1. Introduction and Overview This Statement of Work will be issued in support of the United States Forest Service (USFS) mission to sustain the health, diversity, and productivity of the nation’s forests and grasslands to meet the needs of present and future generations. The initiative will focus on addressing systemic maintenance and critical infrastructure issues afflicting the USFS tower inventory and their ability to support mission critical activities. The contracting entity will serve independently to provide technical, and logistics services to support the Federal Aviation Administration (FAA) in the efforts detailed within this scope of work.

2. Scope of Work The scope of work will encompass the implementation of guy system tensioning, minor guy system repair required for tensioning and new grounding installed on the guys and guy anchors of all identified USFS tower assets. Tensioning, minor repairs, and grounding shall be performed to meet applicable standards on each identified structure. Selected contractor(s) shall provide all necessary tools, equipment, material, and technical expertise to complete this effort:

a. System Types: Guyed lattice-based communication towers, guyed lattice-based fire watch/lookout towers, guyed lattice-based research towers.

b. Minor Repair: Correction of guy system deficiencies that have been identified in the FAA provided field report and/or found during on site contractor activities that impact the tower’s ability to safely maintain tension. Deficiencies are identified below in site specific requirements.

c. Grounding: A waterfall ground lead shall be installed on each guy wire near ground level. Each anchor shaft or fan plate shall also be bonded. The grounding leads shall be #2 tinned copper (stranded or solid). A new ground rod shall be installed in front of the anchor per applicable standards.

d. Facility Type:

• Sole-Use: Stand-alone tower with communications building or box that is not attached to any other facility even if on the same land unit.

e. Site Specific Requirements:

• Sites – Winona Repeater

i. Tension each guyed wire to initial tension as specified in TIA-222 Rev. H.

ii. Perform corrosion abatement and control to each guyed wire anchor.

1. Dig to block method is required to inspect guy anchor shaft for corrosion.

iii. Install safety wire at each guy anchor termination point.

iv. Perform corrosion abatement and control on all visually identifiable spots of corrosion throughout the tower and guyed system.

1. Iron, steel, or aluminum surfaces to be coated shall be clean, i.e.

devoid of grease, oil, mill scale, oxidation, loosely adherent rust, paint, etc. to SSPC (Steel Structure Painting Council).

2. Grease and Oils - Solvent clean to SSPC-SP1.

3. Rust scale or easy to remove paint - Power tool and hand tool clean to SSPC-SP3.

4. The coating shall be applied at sufficient wet film thickness to achieve a minimum dry film build of 2.5 - 3.5 mils, using manufacturer's recoat time directions.

• Site –Golden Pond Repeater

i. Tension each guyed wire to initial tension as specified in TIA-222 Rev. H.

ii. Perform corrosion abatement and control to each guyed wire anchor.

1. Dig to block method is required to inspect guy anchor shaft for corrosion.

iii. Install safety wire at each guy anchor termination point.

iv. Correct all ground system connections that are above 25 ohms in accordance NFPA 780.

v. Grounding resistance should meet NFPA 780’s preferred 10 ohms of resistance with 25 ohms as the accepted minimum standard. Resistance levels more than 25 ohms will need to be approved should soil conditions limit the achievement of referenced minimum standards.

Details and acceptations to above grade grounding installation.

1. Standard Conductor sizes: #2/0 AWG 133,100 Cir. Mils

2. The target for the total ground resistance of this system is twenty-five (25) ohms or less.

3. Ground connections shall be exothermic welds when possible or a non-reversible ground lug connection otherwise. Notable exceptions for exothermic welding, all above grade connections, tower legs, locations in dry or arid conditions with approval.

4. The interconnection of the lightning protection system grounding electrodes and other grounded media shall be in the form of a ground loop conductor.

5. Each leg of a self-supporting tower shall be bonded to the tower ground ring using grounding conductors of 35 mm2 csa (#2 AWG) or coarser, bare, solid, tinned, copper conductor. Connection method shall be manufacturer or engineer approved.

6. Provide As-Built drawings of ground system if modified from original installed design.

vi. Perform corrosion abatement and control on all visually identifiable spots of corrosion throughout the tower and guyed system.

5. Iron, steel, or aluminum surfaces to be coated shall be clean, i.e.

devoid of grease, oil, mill scale, oxidation, loosely adherent rust, paint, etc. to SSPC (Steel Structure Painting Council).

6. Grease and Oils - Solvent clean to SSPC-SP1.

7. Rust scale or easy to remove paint - Power tool and hand tool clean to SSPC-SP3.

8. The coating shall be applied at sufficient wet film thickness to achieve a minimum dry film build of 2.5 - 3.5 mils, using manufacturer's recoat time directions.

vii. Perform tower mapping on structure.

viii. Perform remediation to inoperable obstruction lighting.

1. Obstruction lighting control box cleaned and sealed.

• Site - Cass Repeater

i. Tension each guyed wire to initial tension as specified in TIA-222 Rev. H.

ii. Perform corrosion abatement and control to each guyed wire anchor.

1. Dig to block method is required to inspect guy anchor shaft for corrosion.

iii. Install safety wire at each guy anchor termination point.

iv. Clear soil and vegetation around the immediate area of the guy anchor, guy lanes and establish erosion control.

v. Install grounding at each guy anchor location as specified in TIA-222 Rev.

H.

vi. Grounding resistance should meet NFPA 780’s preferred 10 ohms of resistance with 25 ohms as the accepted minimum standard. Resistance levels more than 25 ohms will need to be approved should soil conditions limit the achievement of referenced minimum standards.

vii. Install above grade ground system on tower and shelter to meet NFPA 780 and TIA-222 current addition.

Details and acceptations to above grade grounding installation.

1. Standard Conductor sizes: #2/0 AWG 133,100 Cir. Mils

2. Air terminal shall be installed no less than 6’ above the tallest antenna with an isolated lead rundown the tower and tied into the grounding system according NFPA 780. A rolling sphere design to support air terminal placement shall be provided and approved prior to installation.

3. Number of Down Conductors. At least two down conductors shall be provided on any kind of structure, including steeples. NFPA 780 5.4 does not apply.

4. The target for the total ground resistance of this system is twenty-five (25) ohms or less.

5. Ground rods shall not be less than 5/8 in. (12.7 mm) in diameter and 10 ft (2.4 m) long.

6. Ground connections shall be exothermic welds when possible or a non-reversible ground lug connection otherwise. Notable exceptions for exothermic welding, all above grade connections, tower legs, locations in dry or arid conditions with approval.

7. Ground rods that cannot be driven straight down, due to contact with rock formations, may be driven at an oblique angle of not greater than 45 degrees from the vertical or may be buried horizontally and perpendicular to the building, in a trench at least 762 mm (30 in.) deep.

8. The interconnection of the lightning protection system grounding electrodes and other grounded media shall be in the form of a ground loop conductor.

9. Each leg of a self-supporting tower shall be bonded to the tower ground ring using grounding conductors of 35 mm2 csa (#2 AWG) or coarser, bare, solid, tinned, copper conductor. Connection method shall be manufacturer or engineer approved.

10. The tower ground bus bar shall be connected to the tower grounding electrode system with a 35 mm csa (#2 AWG) or coarser, bare, solid, tinned, copper conductor.

11. Provide As-Built drawings of ground system.

viii. Install ice bridge/ transmission pathway from tower to shelter to properly support transmission lines, in accordance with NFPA standards.

1. The Ice bridge is to be self-supporting, galvanized, not connected to the tower, or building and include a 3" heavy duty 12-gauge steel perforated or solid cover.

2. Feedlines are to be supported via trapeze kits and appropriate hangers.

3. Ice Bridge shall provide protection to the cables from falling ice and provide a means to support the cables from the tower to the building, cables shall not be unsupported for more than 4 feet.

4. Ice Bridge posts shall be installed in the following manner: at the termination points of the bridge two posts shall be installed across from each other with no more than 12” of the unsupported bridge, mid-span there shall be no more than 4 feet of unsupported bridge with single posts installed in a staggered fashion.

ix. Secure waveguide/cable to tower at 3 ft. intervals where not currently attached with appropriate hangers.

x. Perform corrosion abatement and control on all visually identifiable spots of corrosion throughout the tower and guyed system.

1. Iron, steel, or aluminum surfaces to be coated shall be clean, i.e.

devoid of grease, oil, mill scale, oxidation, loosely adherent rust, paint, etc. to SSPC (Steel Structure Painting Council).

2. Grease and Oils - Solvent clean to SSPC-SP1.

3. Rust scale or easy to remove paint - Power tool and hand tool clean to SSPC-SP3.

4. The coating shall be applied at sufficient wet film thickness to achieve a minimum dry film build of 2.5 - 3.5 mils, using manufacturer's recoat time directions.

xi. Perform tower mapping on structure.

xii. Install battery terminal covers.

xiii. Install connector weather proofing @ 45’ and 130’.

xiv. Tighten or remove and replace guy wire pull off hardware on leg A.

xv. Remove abandoned transmission lines.

Repair or regrout spalling/ chipping foundation concrete.

2.1. Location of Work

a. Guyed tensioning and minor repair work will be conducted at USFS field sites and offices by the selected contractor(s).

b. Preparation and planning of activities can be accomplished at the contractor’s home office, and USFS field offices (field office management approval required).

c. Field Work Locations.

i. See tower inspection reports in attachments 01-03 for each location.

1. 03F SOW Attach 01_6973GH-25-R-00093_Winona Repeater-20210129- Combined-TSIR-v-13

2. 03F SOW Attach 02_6973GH-25-R-00093_Golden Pond-20210323-Combined- TSIR-v-13

3. 03F SOW Attach 03_6973GH-25-R-00093_Cass Repeater-20240412-TSIR--V15.4

2.2. Schedule

The Contractor is required to submit a preliminary schedule ten (10) days after award for the project executed under this SOW for Government approval and submit a final schedule two (2) weeks prior to start of work. This project shall be completed within 30 days of start.

• Contract Award

• Post Award Conference

• Deployment Readiness Review

• Mobilization

• Field Work Start

• Testing

• Field Work Finish

• Clean-up, Site Restoration

2.3. Site Access

The Contractor shall provide a schedule for staging of equipment and materials, and installation. Site access will be made available to the Contractor by FAAand the USFS. For all site visits the contractors shall provide the assigned USFS radio technician with the date, time, and meeting place for the site visit. The assigned USFS radio technician can advise the contractor what types of vehicles may be necessary for traversing the area. All questions regarding scope shall be sent to the primary and/or secondary contacts provided below. Local USFS POC’s do not have the authority to change the SOW or make decisions that incur cost or added contract time.

a. When site POC’s are not provided, the contractor can defer to the Primary

USFS POC for a site contact to be provided.

b. When contacting any contact provided via e-mail the contractor should include all primary and secondary contacts.

Project POC(s):

Primary FAA

Name: Brent Edgemon Title: Project Manager Email: brent.edgemon@faa.gov Number: 405-834-0738

Secondary FAA

Name: Bradley Vaillancourt Title: Project Manager Email: bradley.vaillancourt@faa.gov Number: 405-201-2810

Primary USFS Name: Yana Patton Title: Communication Site Manager Email: yana.patton@usda.gov Number: 530-226-2779

Secondary USFS Name: Lisa Anheluk Title: Engineering Program Manager Email: lisa.anheluk@usda.gov Number: 202-205-0934

3. Government Equipment Security

a. Physical Security: The contractor shall be responsible for safeguarding all government property provided for contractor use. At the close of each work period, government facilities, equipment, and materials shall be secured.

b. Key Control: The Contractor shall establish and implement methods of making sure all keys/key cards issued to the Contractor by the Government are not lost or misplaced and are not used by unauthorized persons.

4. Applicable Standards

a. OSHA (1910 and 1926)

i. Contractor shall follow all applicable standards, health, and safety practices.

b. ANSI-TIA 222 Rev. H

i. 7.6.1 Initial Tension. The initial tension in guys, for design purposes, at an ambient temperature of 60o F [16o C] shall be within upper and lower limits of 15 and 7 percent, respectively, of the manufacturer’s rated breaking strength of the strand. Values of initial tension beyond these limits may be used provided consideration is given to the sensitivity of the structure to variations in initial tension. The design ambient temperature may be adjusted based on site-specific data.

ii. 13.3.2 Guy Tensions. The maximum deviation from the design initial tension shall be ± 10% for guys up to and including 1 in. [25 mm] diameter and ± 5% for guys greater than 1 in. [25 mm] diameter, of the specified design initial tension at an anchorage, corrected for the ambient temperature.

iii. 7.4.6.1 Turnbuckies. Turnbuckles used to connect guy assemblies, shall be forged from AISI grade 1030, 1035 or 1045 steel or equivalent, and suitably heat-treated (quenched and tempered, normalized or annealed).

iv. 10.4 Electrical Resistance & 10.5 Grounding Materials 10.5 Grounding Materials

Statement of Work Power Installation

c. NFPA 780

d. Obstruction Evaluation / Airport Airspace Analysis (OE/AAA)

5. Deliverables and Schedule of Delivery

a) Remediation plan shall be submitted with final schedule two weeks prior to start of work.

b) Documents shall include a report of completed on sites activities, test data for tensioning before and after tensioning.

c) Schedule of prework and on-site activities is to be provided by the contractor and accepted by the Primary Project POC.

d) Pictures shall be taken of all below grade work before, during and after excavation.

e) Post site completion all field reporting, images, SA, and data packages are to be delivered to the Primary Project POC within 30 days.

f) Any final delivery of project documents shall be submitted in PDF format.

6. Completion Criteria

a. All required project documents have been provided to USFS and FAA and have been formally accepted.

b. All specified requirements have been completed and accepted.

STRUCTURE SUPPORT

BRANCH

FAA MMAC AML-4023

TOWER INSPECTION

REPORT

Site ID: 080911T0809016 v.13 1

Top Page Region 08 Forest 09 Site Winona Repeater Life Safety Mission Capability Environmental Overall Tower Condition Site Coordinates Lat/Long 34°50'14.24"N, 92°52'55.24"W Inspection Team Matthew Burnett & Tyler Nelson Inspection Report Reviewed By Tanner Burnett Date of Inspection 1/29/2021 Obstruction Lighting No RF readings (safe/unsafe) Safe Tower Manufacture Unknown Tower Model Unknown Serial Number Unknown Associated Drawing Numbers N/A Tower Height 100’ Number of Sections 6 Elevation of Tower Slope Change N/A Tower Type/System Type: Guyed System: Government Tower Leg and Brace Dimensions Leg: 0.140” Brace: 0.65” Foundation Dimensions/Type Dimensions 23”x23”x18” Type: Slab Tower Cross Section/Face Width Triangular Face Width: 16” Base/Section Bolt Size/Grade Base: N/A Section: N/A Climbing Ladder/ Stairs Dimensions Ladder width: N/A Rung to rung: N/A

Rung type: N/A Rung size: N/A Weather Conditions Temperature: 48°F RH: 59.9%

Wind speed: 2 mph Skies: Clear Access Road Owner: FS Road Surface:2 - HIGH CLEARANCE

VEHICLES

Accessibility: 4 X 4 Required

Road Length: 600’ Access road starting Lat/Long: 34°50'14.00"N, 92°52'50.54"W Narrowest Width: 16’ Access Road Notes: Rough at the end.

03F SOW Attach 01_6973GH-25-R-00093_Winona Repeater-20210129-Combined-TSIR-v-13

Site Assessment Deficiency Report

• Green: No issues or minor issues noted due to non-compliance with a current standard.

• Yellow: Non-critical issues identified that should be corrected when possible, but is not an immediate concern.

• Red: Critical issues identified that may affect personnel safety, cause a system outage, or damage to equipment.

These issues require immediate attention or should be condemned. A Do Not Climb sign is installed if the structural integrity of the tower is compromised.

Life-Safety Compliance

PRIORITY LEVEL: 2 DEFICIENCY DESCRIPTION WITH RECOMMENDED CORRECTIVE ACTION (RCA):

-No lightning protection system (including down conductors and air terminals) has been installed on the tower.

RCA: Install an LPS to include an air terminal, down conductors, and tie into an earth electrode system in accordance with NFPA 780 Section 4.

-No safety climbing system installed on the tower. RCA: Install a lad-safe climbing device in accordance with OSHA 1926.1053(a) (22).

Reference: OSHA Deficiencies (OSHA Standards), Electrical Safety Deficiencies (NEC and NFPA 780) industry best practices), and Hazardous Conditions (issues of concern, life threatening).

Mission Capability

PRIORITY LEVEL: 2 DEFICIENCY DESCRIPTION WITH RECOMMENDED CORRECTIVE ACTION (RCA):

-Recommend collecting as-build’s or performing a tower mapping to conduct a structural analysis to determine an operational wind speed. Operational wind speeds are necessary to determine proper inspection procedures and life safety checks for unmaintained structures. Based on the unrecorded maintenance history of the overall tower a structural analysis should be completed as soon as possible.

-CSF-1 corrosion has developed in various spots throughout the tower legs and braces. RCA: Perform corrosion abatement, recoat the surface, and continue to monitor.

Reference: Probability of system outage due to any reason, system life in current condition, theft/tampering preventive measure adequacy, Grounding & Bonding (NFPA 780), Lightning Protection System (NFPA 780), and Utilities & Power (NEC).

Environmental

PRIORITY LEVEL: 2 DEFICIENCY DESCRIPTION WITH RECOMMENDED CORRECTIVE ACTION (RCA):

-Large trees have grown into guy wire system B. RCA: Cut down trees growing around guy wires and continue to monitor.

Reference: Wildlife and pest control, weather conditions, flood control, and hazardous waste conditions

Section 1: Inspection Data Collection Concrete PSI Test (Vertical) Concrete PSI Test (Horizontal)

Slab: 2,355 PSI Slab: N/A Leg B: N/A Leg B: N/A Leg C: N/A Leg C: N/A Leg D: N/A Leg D: N/A Leg E: N/A Leg E: N/A Leg F: N/A Leg F: N/A

Metal Thickness Average (Inches) Coating Thickness Average (Mils)

Leg A: 0.141” Member A: 0.659” Leg A: 3.81 Mils Member A: 5.9 Mils Leg B: 0.139” Member B: 0.651” Leg B: 3.87 Mils Member B: 6.3 Mils Leg C: 0.143” Member C: 0.659” Leg C: 4.45 Mils Member C: 6.2 Mils Leg D: N/A Member D: N/A Leg D: N/A Member D: N/A Leg E: N/A Member E: N/A Leg E: N/A Member E: N/A Leg F: N/A Member F: N/A Leg F: N/A Member F: N/A

3 Point Ground Resistance Reading Soil Resistivity Reading

7.32 Ω 12.18 Ω

Bonded Points Inspection Ohms Bonded Points

Inspection Ohms Structure Bond A: N/A Down Conductor A: N/A Structure Bond B: N/A Down Conductor B: N/A Structure Bond C: N/A Down Conductor C: N/A Structure Bond D: N/A Down Conductor D: N/A

Inspection Ohms

Shelter Bonds: N/A Bus Bar Bonds: N/A Fence Post Bonds: N/A Fence Corner Bonds: N/A Wireway Bonds: N/A Conduit Bonds: N/A Guy Wire Bonds: N/A Other Bonds: N/A

Guy Wire System

Inspection Strand Type/Size Foot Pounds (lbfs.)

(Legs with multiple guys, measurements are entered bottom to top)

Leg A: 1-7 / 1/4” & 5/16” 700 lbfs & 1,100 lbfs Leg B: 1-7 / 1/4” & 5/16” 600 lbfs & 900 lbfs Leg C: 1-7 / 1/4” & 5/16” 500 lbfs & 1,100 lbfs Leg D: N/A N/A

PLUMB AND TWIST INFORMATION WILL BE IN ATTACHMENT Pass

Test Data Notes

None

Section 2: Inspection Data Tower member (Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -Tower legs do not have weep holes. RCA: Drill weep holes into the tower base after a tower assessment has determined size and location.

Damaged/Bent members (legs & braces)

Loose members ☒ Mounted Equipment

(Antennas, etc.) ☒

Welded connections (cracks, etc.) ☒

Weep holes (plugged/not plugged) ☐ 3

Fasteners

(Nuts, Bolts, etc. Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A

Loose ☒ Missing ☒

Damaged ☒ Abandon ☒

Guy Wire System

(Ref. Annex J TIA 222-H)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -Large trees have grown into guy wire system B. RCA: Cut down trees growing around guy wires and continue to

Strand condition ☒ Turnbuckles ☒

Cable Connectors ☒ Guy Tensions ☒ Guy Anchors ☒

Ladder, Platform, Catwalks

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -No safety climbing system installed on the tower. RCA:

Install a lad-safe climbing device in accordance with OSHA 1926.1053(a) (22).

Ladder Climbing Safety System ☐ 2

Bent, damaged or missing members ☐ N/A

Catwalk flooring (i.e.

grating/wood planks) ☐ N/A

Hinged access ☐ N/A Fastening hardware (nuts, bolts, screws, rivets, etc.) secure

☐ N/A

Transmission Lines

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A Coax and/or Waveguide condition ☒

Connector weatherproofing ☒

Transmission line supports ☒

Lights and Sensors

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A Obstruction Light Bulbs and lenses - condition ☐ N/A

Obstruction Light Control Box ☐ N/A

Obstruction Light Photo Cell ☐ N/A

Wiring condition ☐ N/A

Section 3: Foundation Condition Ground

Condition (Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A Settlement, movement, or earth cracks around foundations

Erosion around foundations ☒

Other foundation concerns (standing water, drainage, vegetation, etc.)

Concrete Condition

(Visual Inspection and Digishmidt Test, see test section 1)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -CSF-2 cracking on tower foundation slab. RCA: Repair foundation to maintain structural integrity, and continue to

Foundation grout condition ☒

Cracking, spalling, splitting, chipping ☐ 2

Low spots - collecting moisture ☒

Section 4: Corrosion, Wood Rot, and Coating Main Tower and Facilities Wooden and Steel

(Visual Inspection, Elcometer thickness and coating reading from Section 1) Ref TI-222-H

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority

-CSF-1 corrosion has developed in various spots throughout the tower legs and braces. RCA: Perform corrosion

Legs, braces, and other structural members ☐ 3

Climbing facilities – stairways, ladders, guardrails, etc.

☐ N/A

Electrical through ways- conduits, j-boxes, light fixtures ☐ N/A

Grating/wood planks ☐ N/A Equipment Mounts ☒

Ground and Lightning Protection System

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -CSF-2 corrosion has developed on leg A & B structure bond. RCA: Perform corrosion abatement, recoat the surface, and continue to monitor.

Lightning Protection

System ☐ N/A

Bus Bars, including bolts, grounding lugs and crimped connections

☐ 3

Welds and other bonding connections ☐ N/A

(nuts, bolts, clamps)

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -CSF-1 corrosion has developed throughout all tower structural hardware. RCA: Perform corrosion abatement, recoat the surface, and continue to monitor.

-CSF-2 corrosion has developed on hardware securing the antenna mounts. RCA: Replace all hardware that has progressed to CSF-2 and above.

Climbing facilities – stairways, ladders, guardrails, etc.

☐ N/A

Electrical through ways- conduits, j-boxes, light fixtures ☐ N/A

Equipment Mounts ☐ 3

Section 5: Overall Lightning Protection, Bonding, and Grounding

Inspection Points

(Visual Inspection, 3 point ground test, megger, and milli-ohms meter) Ref:

NFPA 780

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -No lightning protection system (including down conductors and air terminals) has been installed on the tower. RCA:

Install an LPS to include an air terminal, down conductors, and tie into an earth electrode system in accordance with NFPA 780 Section 4.

-The equipment mounts are not bonded to the earth electrode system, and is not within a zone of protection.

RCA: Bond the equipment mounts to an EES, or establish a zone of protection in accordance with NFPA 780 Section 4.

-Guy wire leg C are not bonded to an earth electrode system. RCA: Bond the guy wires to an EES in accordance with NFPA 780 Section 4.

-Structural bonding is missing from leg C and not properly grounding the tower to an earth electrode system. RCA:

Ensure all legs of the tower are properly bonded to an EES in accordance with NFPA 780 Section 4.

-No ground well has been installed for earth electrode system test readings. RCA: A ground test well should be installed in accordance with NFPA 780 Annex A.4.13.1.

Lightning Protection System (Rolling Ball, Air Terminal, Halo, and Down Conductor)

☐ 2

EES (Test Well, Conductor Size, and

Ground Rods) ☐ 3

Structure Bonds (Tower and Shelter) ☐ 2

Equipment Bonding (Antennas/Masts, Conduit, J Boxes, Generator, LP tank, and Solar Array)

☐ 3

Fence Bonding (Fence Posts, Gates and Gate

Posts, and Security Wire)

Guy Wires ☐ 3

Section 6: Tower, Foundation, and Grounding Condition Pictures CSF-2 corrosion on structure bonds

Cracks in the foundation

Trees growing around guy system B

CSF-1 Corrosion

CSF-1 Corrosion

CSF-2 Corrosion

Section 7: Shelter Information Shelter Exterior Picture

Shelter Interior Picture

STRUCTURE NAME: Winona Repeater STRUCTURE SUPPORTS: Communication

HVAC BTU: N/A Make: N/A STRUCTURE TYPE: Basic HVAC Model: N/A MAKE: Rohn HVAC Serial: N/A MODEL: 964 EXTERIOR L x W x H: 8’x8’x8’ SERIAL: Unknown INTERIOR L x W x H: 7’x7’x7’ USED FLOOR SPACE(2’x2’ typical rack): 2 NUMBER OF RACKS: None AVAILABLE FLOOR SPACE(based on a 2’x’2 square and not entering egress areas): 2

Shelter

Inspection Points

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -Shelter does not have a fire extinguisher installed. RCA:

Install a fire extinguisher in accordance with OSHA standard 1910.157.

Exterior (Roof, Walls, Foundation, Doors, Windows)

Interior (Ceiling, Walls, Floor) ☒

Electrical (Lighting, Outlets, Load centers) ☒

Fire Extinguishers ☐ 3 https://www.osha.gov/laws-regs/interlinking/standards/1910.157

Section 9: Primary and Redundant Power Information Primary Power Picture

Redundant Power Picture

Primary Type: Commercial Redundant Power Type: Battery Transformer #: Unknown Fuel Type: N/A Pole or Protector #: Unknown Transfer Switch Installed: Yes Meter #: 1NF031548464 Fuel Tank Capacity: N/A Power Phase #: Single Phase Generator Make: N/A Site Disconnect: Yes Model: N/A Serial: N/A

Points (Visual Inspection, megger, and milli-ohms meter) Ref:

NFPA 780 and NEC

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A

Meter Base ☒ Site Disconnect ☒

Grounding ☒ Wiring/Conduit ☒

Battery/s ☒ LP Tank Condition ☐ N/A LP Lines Condition ☐ N/A

Solar Panels ☐ N/A

FAA MMAC AML-4023

TOWER INSPECTION

REPORT

Site ID: 0860T v.13 1

Top Page Region 08 Forest 60 Site Golden Pond Tower Life Safety Mission Capability Environmental Overall Tower Condition Site Coordinates Lat/Long 36°46'54.53"N, 88°3'27.91"W Inspection Team Matthew Burnett and Tyler Nelson Inspection Report Reviewed By Tanner Burnett Date of Inspection 3/23/2021 Obstruction Lighting No RF readings (safe/unsafe) Safe Tower Manufacture Sabre Tower Model 3600 Serial Number Unknown Associated Drawing Numbers GPD/PROJ. #: 2018742.20 Tower Height 385’ Number of Sections 21 Elevation of Tower Slope Change N/A Tower Type/System Type: Self Supported System: Government Tower Leg and Brace Dimensions Leg: 2.25” Solid, 7” Circumference Brace: 0.9” Foundation Dimensions/Type Dimensions: 2’ Circumference Type: Round Pier Tower Cross Section/Face Width Triangular Face Width: 3’ Base/Section Bolt Size/Grade Base: N/A Section: Welds Climbing Ladder/ Stairs Dimensions Ladder width: N/A Rung to rung: N/A

Rung type: N/A Rung size: N/A Weather Conditions Temperature: 62°F RH: 59%

Wind speed: 3 mph Skies: Overcast Access Road Owner: FS Road Surface:5 - HIGH DEGREE OF

USER COMFORT

Accessibility: All vehicles

Road Length: 400’ Access road starting Lat/Long: 36°46'51.65"N, 88°3'18.19"W Narrowest Width: 14’ Access Road Notes: Forest key for site, to get to guy wire you need a special key.

03F SOW Attach 02_6973GH-25-R-00093_Golden Pond-20210323-Combined-TSIR-v-13

• Yellow: Non-critical issues identified that should be corrected when possible, but is not an immediate concern.

• Red: Critical issues identified that may affect personnel safety, cause a system outage, or damage to equipment.

These issues require immediate attention or should be condemned. A Do Not Climb sign is installed if the structural integrity of the tower is compromised.

Life-Safety Compliance

PRIORITY LEVEL: 2 DEFICIENCY DESCRIPTION WITH RECOMMENDED CORRECTIVE ACTION (RCA):

-Lightning protection system has no down conductors and has instead been grounded to the tower. RCA: Install 2 or more down conductors and bond them to the existing EES in accordance with NFPA 780 Section 4.

Reference: OSHA Deficiencies (OSHA Standards), Electrical Safety Deficiencies (NEC and NFPA 780) industry best practices), and Hazardous Conditions (issues of concern, life threatening).

Mission Capability

PRIORITY LEVEL: 2 DEFICIENCY DESCRIPTION WITH RECOMMENDED CORRECTIVE ACTION (RCA):

-CSF-1 corrosion has developed the higher you get on the tower legs and braces. RCA: Perform corrosion

Reference: Probability of system outage due to any reason, system life in current condition, theft/tampering preventive measure adequacy, Grounding & Bonding (NFPA 780), Lightning Protection System (NFPA 780), and Utilities & Power (NEC).

Environmental

PRIORITY LEVEL: N/A DEFICIENCY DESCRIPTION WITH RECOMMENDED CORRECTIVE ACTION (RCA):

N/A

Reference: Wildlife and pest control, weather conditions, flood control, and hazardous waste conditions

Concrete PSI Test (Vertical) Concrete PSI Test (Horizontal)

Slab: 6,405 PSI Slab: N/A Leg B: N/A Leg B: N/A Leg C: N/A Leg C: N/A Leg D: N/A Leg D: N/A Leg E: N/A Leg E: N/A Leg F: N/A Leg F: N/A

Leg A: 2.3” Member A: 0.9” Leg A: 7.9 Mil Member A: 6.6 Mil Leg B: 2.3” Member B: 0.9” Leg B: 7.0 Mil Member B: 6.3 Mil Leg C: 2.3” Member C: 0.9” Leg C: 11.1 Mil Member C: 7.2 Mil Leg D: N/A Member D: N/A Leg D: N/A Member D: N/A Leg E: N/A Member E: N/A Leg E: N/A Member E: N/A Leg F: N/A Member F: N/A Leg F: N/A Member F: N/A

0.97 Ω 0.72 Ω

Inspection Ohms Bonded Points

Inspection Ohms

Structure Bond A: 108 Ω Down Conductor A: N/A Structure Bond B: 143 Ω Down Conductor B: N/A Structure Bond C: 0.097 Ω Down Conductor C: N/A Structure Bond D: N/A Down Conductor D: N/A

Inspection Ohms

Shelter Bonds: South Middle 0.143 Ω, SW Corner 0.168 Ω Bus Bar Bonds: Tower 0.155 Ω, Inside Shelter 0.142 Ω Fence Post Bonds: 0.140 Ω Fence Corner Bonds: 0.142 Ω Wireway Bonds: N/A Conduit Bonds: N/A Guy Wire Bonds: A-0.45 Ω, B-3.2 Ω, C-7.9 Ω Other Bonds: Ice Bridge 0.178 Ω, Left HVAC 0.139 Ω, Right HVAC OL

Inspection Strand Type/Size Foot Pounds (lbfs.)

(Legs with multiple guys, measurements are entered bottom to top)

Leg A: 1-7 -See Section 10 for guy wire size and lbfs.

Leg B: 1-7 -See Section 10 for guy wire size and lbfs.

Leg C: 1-7 -See Section 10 for guy wire size and lbfs.

Leg D: 1-7 -See Section 10 for guy wire size and lbfs.

PLUMB AND TWIST INFORMATION WILL BE IN ATTACHMENT Pass

-See Section 10 for guy wire size and lbfs.

Section 2: Inspection Data member (Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A Damaged/Bent members (legs & braces)

Loose members ☒ Mounted Equipment

(Antennas, etc.) ☒

Welded connections (cracks, etc.) ☒

Weep holes (plugged/not plugged) ☐ N/A

(Nuts, Bolts, etc. Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A

Loose ☒ Missing ☒

Damaged ☒ Abandon ☒

(Ref. Annex J TIA 222-H)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -Guy Wire A1 tension is high compared to all the other number 1’s. RCA: Loosen guy wire to match other guy wires.

Strand condition ☒ N/A Turnbuckles ☒ N/A

Cable Connectors ☒ N/A Guy Tensions ☐ 3

Ladder, Platform, Catwalks

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A

Ladder Climbing Safety System ☒

Bent, damaged or missing members ☐ N/A

Catwalk flooring (i.e.

grating/wood planks) ☐ N/A

Hinged access ☐ N/A Fastening hardware (nuts, bolts, screws, rivets, etc.) secure

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A Coax and/or Waveguide condition ☒

Connector weatherproofing ☒

Transmission line supports ☒

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -Red night lights are not working. RCA: Get a hold of manufacture to troubleshoot system.

-Light control box has water and chemical corrosion inside that needs to be cleaned up. RCA: Clean up corrosion and reseal.

Obstruction Light Bulbs and lenses - condition ☐ 3

Obstruction Light Control Box ☐ 3

Obstruction Light Photo Cell ☒

Wiring condition ☒

Section 3: Foundation Condition Ground

Condition (Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A Settlement, movement, or earth cracks around foundations

Erosion around foundations ☒

Other foundation concerns (standing water, drainage, vegetation, etc.)

(Visual Inspection and Digishmidt Test, see test section 1)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A

Foundation grout condition ☒

Cracking, spalling, splitting, chipping ☒

Low spots - collecting moisture ☒

Section 4: Corrosion, Wood Rot, and Coating Main Tower and Facilities Wooden and Steel

(Visual Inspection, Elcometer thickness and coating reading from Section 1) Ref TI-222-H

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority

-CSF-1 corrosion has developed the higher you get on the tower legs and braces. RCA: Perform corrosion abatement, recoat the surface, and continue to monitor.

Climbing facilities – stairways, ladders, guardrails, etc.

Electrical through ways- conduits, j-boxes, light fixtures

Equipment Mounts ☒

Ground and Lightning Protection System

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A

Lightning Protection System ☒

Bus Bars, including bolts, grounding lugs and crimped connections

Welds and other bonding connections ☒

(nuts, bolts, clamps)

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -CSF-1 corrosion has developed on section bolts the higher you get up the tower. RCA: Perform corrosion abatement, recoat the surface, and continue to monitor.

-CSF-1 corrosion has developed on various equipment mount hardware on the tower. RCA: Perform corrosion

Climbing facilities – stairways, ladders, guardrails, etc.

Electrical through ways- conduits, j-boxes, light fixtures

Equipment Mounts ☐ 3

Section 5: Overall Lightning Protection, Bonding, and Grounding

Inspection Points

(Visual Inspection, 3 point ground test, megger, and milli-ohms meter) Ref:

NFPA 780

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -Lightning protection system has no down conductors and has instead been grounded to the tower. RCA: Install 2 or more down conductors and bond them to the existing EES in accordance with NFPA 780 Section 4.

-No ground well has been installed for earth electrode system test readings. RCA: A ground test well should be installed in accordance with NFPA 780 Annex A.4.13.1.

-Note: Tower lightning protection system, bonding and grounding are Motorola R56 Industry Standard by Verizon.

They are not to NFPA 780 code, which is accepted by the

USFS.

Lightning Protection System (Rolling Ball, Air Terminal, Halo, and Down Conductor)

☐ 2

EES (Test Well, Conductor Size, and

Ground Rods) ☐ 3

Structure Bonds (Tower and Shelter) ☒

Equipment Bonding (Antennas/Masts, Conduit, J Boxes, Generator, LP tank, and Solar Array)

Fence Bonding (Fence Posts, Gates and Gate

Posts, and Security Wire)

Guy Wires ☒

CSF-1 corrosion on tower surface

Cable bonds look good

CSF-1 corrosion on section bolts

CSF-1 corrosion on mount hardware

Guy system looks good

(3 Point Ground Resistance Reading

STRUCTURE NAME: Golden Pond STRUCTURE SUPPORTS: Communication

HVAC BTU: 35,000 x 2 Make: Bard x 2 STRUCTURE TYPE: Complex, pebble siding HVAC Model: WL361-A0ZEP5XXJ MAKE: Rohn HVAC Serial: 125P991422511-02

Second HVAC is unreadable MODEL: Part # EST2805 EXTERIOR L x W x H: 30’x12’x10’ SERIAL: J013434 INTERIOR L x W x H: 168”x126”x107” USED FLOOR SPACE(2’x2’ typical rack): 7 NUMBER OF RACKS: 5 AVAILABLE FLOOR SPACE(based on a 2’x’2 square and not entering egress areas): 1

Shelter

Points

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A

Exterior (Roof, Walls, Foundation, Doors, Windows)

Interior (Ceiling, Walls, Floor) ☒

Electrical (Lighting, Fire Extinguishers ☒

Primary Type: Commercial Redundant Power Type: Generator Transformer #: Unknown Fuel Type: Diesel Pole or Protector #: Unknown Transfer Switch Installed: Yes Meter #: 1NF043823432 Fuel Tank Capacity: 300 Gallon Power Phase #: Single Phase Generator Make: Generac Site Disconnect: Yes Model: Unknown Serial: Unknown

(Visual Inspection, megger, and milli-ohms meter) Ref:

NFPA 780 and NEC

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -Note: Tower receives power from adjacent buildings.

Meter Base ☒ Site Disconnect ☒

Grounding ☒ Wiring/Conduit ☒

Battery/s ☐ N/A LP Tank Condition ☒ LP Lines Condition ☒

Section 10: Additional Notes/Continuation Sheet Guy Wire A, B, C: 1-7/16”, 2-7/16”, 3-7/16”, 4-7/16”, 5-9/16”, 9-1/2”

Guy Wire A lbfs: 1-3100, 2-1800, 3-2000, 4-1600, 5-3200, 6-2600 Guy Wire B lbfs: 1-1900, 2-2100, 3-2100, 4-1800, 5-3700, 6-3000 Guy Wire C lbfs: 1-2000, 2-2300, 3-1900, 4-2000, 5-3300, 6-3000

FAA MMAC AJW-L523

TOWER INSPECTION

REPORT

Site ID: 0810005T0810003 v.15.4 1

Top Page: Site Information Region/Forest 08/10 Forest Name Ozark St. Francis National Forest Facility Type Remote Facility Use Sole Use Site Name Cass repeater Life Safety Major Mission Capability Major Environmental Good Overall Tower Condition Major Site Coordinates Lat/Long 35°42'52.1"N, 93°48'15.0"W Access Road Starting Lat/Long 35°42'53.8"N, 93°48'11.6"W Inspection Team Anthony Moore, Ricardo Avalos, Paxton Veal Inspection Report Reviewed By Bradley Vaillancourt Date of Inspection 12/4/2024 Date of Last Known Inspection 3/12/2024 Obstruction Lighting No RF readings (safe/unsafe) Safe Tower Manufacture Rohn Tower Model 55 G Inspection Report Acceptance Serial Number N/A Name Bradley Vaillancourt Associated Drawing Numbers N/A Signature

Sign Here Tower Height 180’ 11” Number of Sections 18 Elevation of Tower Slope Change N/A Tower Status/Current Use Status Active Current Use LMR Tower Type/System Type Guyed System Government Tower Leg and Brace Dimensions Leg 1.50” OD Brace 0.440” OD Solid Tower Cross Section/Face Width Cross Section Triangular Face Width 17” Base/Section Bolt Size/Grade Base 2x7/16” Section 2x7/16” Climbing Ladder/ Stairs Dimensions

Ladder Width N/A Rung to Rung N/A Rung Type Tower Members Rung Size N/A

Weather Conditions Temperature 51.5 °F Humidity 56% Wind Speed 1.8mph Skies Partially Cloudy

Site Information Notes Shelter Requires special key from sight tech.

03F SOW Attach 03_6973GH-25-R-00093_Cass Repeater-20240412-TSIR--V15.4

• Yellow: Non-critical issues identified that should be corrected, when possible, but is not an immediate concern.

• Red: Critical issues identified that may affect personnel safety, cause a system outage, or damage to equipment. These issues require immediate attention or should be condemned. A Do Not Climb sign is installed if the structural integrity of the tower is compromised.

Life-Safety Compliance

PRIORITY LEVEL: 2 DEFICIENCY DESCRIPTION WITH RECOMMENDED CORRECTIVE ACTION (RCA):

-No lightning protection system (including down conductors and air terminals) has been installed on the tower. RCA:

Install an LPS to include an air terminal, down conductors, and tie into an earth electrode system in accordance with NFPA 780 Section 4.

-Structural bonding is detached from leg B and not properly grounding the tower to an earth electrode system. RCA:

Ensure all legs of the tower are properly bonded to an EES in accordance with NFPA 780 Section 4.

Reference: OSHA Deficiencies (OSHA Standards), Electrical Safety Deficiencies (NEC and NFPA 780) industry best practices), and Hazardous Conditions (issues of concern, life threatening).

Mission Capability

PRIORITY LEVEL: 2 DEFICIENCY DESCRIPTION WITH RECOMMENDED CORRECTIVE ACTION (RCA):

-The FAA tower mapping/structural analysis is adhering to the current version TIA-222 which stipulates that guyed towers are analyzed once every three years and self-supporting structures analyzed once every five years. It is recommended that subsequent inspections follow the TIA-222 standard.

-The sleeve inside the eye loop for guy wire leg C at 40 feet has started to work its way out. RCA: Replace the sleeve and ensure the connection is compatible.

-Transmission lines are unsupported between the tower and the adjacent building. RCA: Install an ice bridge for proper transmission line support and protection.

-The weatherproofing around the connectors has degraded at 45 and 130 feet. RCA: Use industry standard weatherproofing materials to seal the transmission line connection.

Reference: Probability of system outage due to any reason, system life in current condition, theft/tampering preventive measure adequacy, Grounding & Bonding (NFPA 780), Lightning Protection System (NFPA 780), and Utilities & Power

(NEC).

Environmental

PRIORITY LEVEL: N/A DEFICIENCY DESCRIPTION WITH RECOMMENDED CORRECTIVE ACTION (RCA):

N/A

Reference: Wildlife and pest control, weather conditions, flood control, and hazardous waste conditions.

Concrete PSI Test (Vertical/Horizontal) Dimensions

Slab Vertical 3,650 30.5”x30.5” Leg B N/A N/A N/A Leg C N/A N/A N/A Leg D N/A N/A N/A Leg AA N/A N/A N/A Leg BB N/A N/A N/A Leg CC N/A N/A N/A Leg DD N/A N/A N/A

Leg A 0.241“ Member A 0.440“ Leg A 3.31 mils Member A 3.44 mils Leg B 0.240“ Member B 0.440“ Leg B 3.69 mils Member B 4.02 mils Leg C 0.248“ Member C 0.440“ Leg C 3.26 mils Member C 3.91 mils Leg D N/A Member D N/A Leg D N/A Member D N/A Leg AA N/A Member AA N/A Leg AA N/A Member AA N/A Leg BB N/A Member BB N/A Leg BB N/A Member BB N/A Leg CC N/A Member CC N/A Leg CC N/A Member CC N/A Leg DD N/A Member DD N/A Leg DD N/A Member DD N/A

10.6 Ω 6.818 Ω

Bonded Points Ohms Bonded Points Ohms

Structure Bond A Open Down Conductor A N/A Structure Bond B Broken Down Conductor B N/A Structure Bond C 42.8 Ω Down Conductor C N/A Structure Bond D N/A Down Conductor D N/A

Bonded Points Ohms

Shelter Bonds Exterior: 49.3 Ω, Interior: 0.093 Ω Bus Bar Bonds N/A Fence Post Bonds N/A Fence Corner Bonds N/A Wireway Bonds N/A Guy Wire Bonds A: 0.066 Ω, B: 0.090 Ω, C: 0.083 Ω Other Bonds N/A

Inspection Strand Type Size Foot Pounds (lbfs.)

(Legs with multiple guys, measurements are entered bottom to top)

Leg A 1/7 2x¼”2x5/16”1x¼” 940lbs 540lbs 600lbs 600lbs 640lbs Leg B 1/7 2x¼”2x5/16”1x¼” 640lbs 540lbs 580lbs 640lbs 540lbs Leg C 1/7 2x¼”2x5/16”1x¼” 700lbs 640lbs 680lbs 620lbs 640lbs Leg D N/A N/A N/A

PLUMB AND TWIST INFORMATION WILL BE IN ATTACHMENT N/A

-Plumb and twist data collection was unable to be performed due to the inaccessibility of all tower legs.

Section 2: Tower Structure, and Safety Conditions Tower member and hardware (Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations Yes Priority -Minor bent tower braces and cross braces throughout tower, RCA:

Continue to monitor and take corrective actions if the severity of the bent member increases.

Damaged/Bent Members (Legs & Braces) ☐ 3

Loose Members ☒ Mounted Equipment

(Antennas, etc.) ☒

Welded Connections (Cracks, etc.) ☒

Weep Holes (Plugged/Not Plugged) ☒

Hardware (Loose, Missing, Damaged, Abandon)

(Visual Inspection, Tensiometer Readings

Section 1) Ref. Annex J TIA 222-H

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority -The sleeve inside the eye loop for guy wire leg C at 40 feet has started to work its way out. RCA: Replace the sleeve and ensure the connection is compatible.

Strand Condition ☒ Turnbuckles ☒

Cable Connectors ☐ 2 Guy Tensions ☒

Ladder, Platforms, and Catwalks (Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations Yes Priority -(Deferred) No safety climbing system installed on a tower over 24 feet in height. RCA: Install a lad-safe climbing device in accordance with OSHA 1926.1053(a)(22). Note: Towers over 24 feet are required by OSHA to have lad-safe systems.

Ladder Climbing Safety System ☐ N/A

Bent, Damaged or Missing Members ☐ N/A

Catwalk Flooring (i.e., Grating/Wood Planks) ☐ N/A

Hinged Access ☐ N/A Fastening Hardware (Nuts, Bolts, Screws, Rivets, etc.)

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations Yes Priority -Transmission lines on the tower are improperly supported. RCA: Install industry designed mounting hardware for proper transmission line support.

-Transmission lines are unsupported between the tower and the adjacent building. RCA: Install an ice bridge for proper transmission line support and protection.

-The weatherproofing around the connectors has degraded at 45 and 130 feet. RCA: Use industry standard weatherproofing materials to seal the transmission line connection.

-One transmission line has been abandoned on the tower. RCA: Remove abandoned transmission lines and all associated hardware.

Coax and/or Waveguide Condition ☒

Connector Weatherproofing ☐ 2

Transmission Line Supports ☐ 2

(Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations Yes Priority N/A

Obstruction Light Bulbs and Lenses - Condition ☐ N/A

Obstruction Light Control Box ☐ N/A

Obstruction Light Photocell ☐ N/A

Wiring Condition ☐ N/A

Section 3: Foundation, Fencing, and Environmental Condition Ground Condition

(Visual Inspection) Compliance Deficiencies, Recommended Correction, and Standards/Regulations Yes Priority N/A

Settlement, Movement, or earth cracks ☒

Erosion Around Foundations ☒

Other Ground Concerns (Standing Water, Drainage, etc.)

(Visual Inspection, Digishmidt Concrete PSI Readings Section 1)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority N/A

Grout Condition ☒ Cracking, Spalling, Chipping ☒

Low Spots (Collecting Moisture) ☒

Fencing and Security Wire (Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations Yes Priority N/A

Gated Access Points ☐ N/A Fence Posts ☐ N/A

Fencing Material (Chain Link, Wood Pickets, etc.) ☐ N/A

Security Wire (Barbed and Razor Wire) ☐ N/A

Fastening Hardware (Bolts, Screws, etc.) ☐ N/A

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Environmental

(Visual Inspection)

Yes Priority N/A

Vegetation Overgrowth (Trees, Brush, Vines etc.) ☒

Waste, Biohazards ☒ Infestation (Wasps, Rodents etc.) ☒

Section 4: Corrosion, Wood Rot, and Coating Condition Main Tower and

Facilities Wooden and Steel (Visual Inspection, Elcometer Thickness and Coating Readings from Section 1) Ref TI-222-H

Compliance Deficiencies, Recommended Correction, and Standards/Regulations

Yes Priority

-CSF-1 corrosion has developed on the tower legs and braces, in spots throughout. RCA: Perform corrosion abatement, recoat the surface, and continue to monitor.

Legs, Braces, and Other Structural Members ☐ 3

Climbing Facilities Stairways, Ladders and

Safety Systems, Grating/Wood Decking

☐ N/A

Electrical Through Ways, Conduits, etc. ☐ N/A

Equipment Mounts ☒ Fencing and Security

Wire ☐ N/A

Lightning Protection System (Conductors, Bus Bars, Welds, Bonding Connectors)

Fasteners (Nuts, Bolts, Clamps) (Visual Inspection)

Compliance Deficiencies, Recommended Correction, and Standards/Regulations Yes Priority -CSF-1 corrosion has developed on structural hardware, at 150 feet. RCA:

Perform corrosion abatement, recoat the surface, and continue to monitor.

-CSF-2 corrosion has developed on legs A, B, and C structure bonding hardware. RCA: Replace all bonding hardware that has progressed to CSF-2 and above.

-CSF-2 corrosion has developed on saddle clamps at the top of the guy wire for legs A, B, and C at the first and second guy pull off. RCA: Replace all saddle clamps with CSF-2 or greater corrosion.

Legs, Braces, and Other Structural Members ☐ 2

Climbing Facilities Stairways, Ladders and

Safety Systems, Grating/Wood Decking

☐ N/A

Electrical Through Ways, Conduits, etc. ☒

Equipment Mounts ☐ 2 Fencing and Security

Wire ☐ N/A

Light…

This is the start of the file's text. The full file is on GovTribe.