Attachment 0022a.1.b - ALH-209032 00 CABLE ASSEMBLY CASS.pdf
PDF 241 KB Posted
- Attached to
- RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
- Solicitation number
- W31P4Q-20-R-0015
About this file
This solicitation requests proposals for the production of Integrated Battle Command System hardware in accordance with supplied technical data packages and specifications. The U.S. Army Materiel Command Contracting Command at Redstone Arsenal seeks a contractor to produce IBCS hardware end items for Low Rate Initial Production and Full Rate Production runs. The selected contractor must maintain approved software, firmware updates, cybersecurity, and authority to operate on existing hardware components. The contractor may also be required to execute engineering changes for obsolescence, new capabilities, and export considerations during the period of performance. Questions regarding this solicitation are due by December 10, 2020 at 4:00 PM Central Standard Time. This final RFP is only open to contractors who met entrance criteria on Beta.SAM and were approved by the Integrated Fires Mission Command Project Office.
View the file
Other files for this federal contract opportunity
Show all 50
RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2012/08/06
W31P4Q-08-C-0418
DATEAPPROVALS
PROJECT APPROVAL
DESIGN ACTIVITY
CCB CHAIR
T. ALKIRE
J. WETHINGTON
ENGR
K. HANVEY
J. BULLEIGH
CONTRACT NO.
1 OF 3 SHEETNONE SCALE
NG-IPS-ALH8-AC-D00 (IBCS)
CAGE CODESIZE DWG NO. REV.is restricted by the Arms Export Control Act (Title 22, U.S.C., Sec 2751, et. seq.) or the Export Administration Act of 1979, as amended, Title 50, U.S.C., App. 2401 et. seq. Violations of these export laws are subject to severe criminal penalties. Disseminate in accordance with provisions of DoD Directive 5230.25.
WARNING - This document contains technical data whose export
Official version of this document is electronically controlled in an online PLM system. Verify version level prior to use.
DISTRIBUTION STATEMENT C: Distribution authorized to the U.S. Government Agencies and their contractors; Administrative and Operational Use; 05 Jan 2007. Other requests for this document shall be referred to ATTN: SFAE-MSLS-IAMD, Program Executive Office Missiles and Space, Integrated Air and Missile Defense Project Office. Bldg. 5250 Martin Road, Huntsville, Al 35898-8000.
Copyright 2012 Northrop Grumman Systems Corporation
NOTES:
1. APPLICABLE STANDARDS/SPECIFICATIONS:
ASME Y14.5M - 1994, DIMENSIONING AND TOLERANCING
2. WORKMANSHIP SHALL MEET OR EXCEED IPC/WHMA-A-620 CLASS 3.
3. SEE ALH-900000 FOR ENGINEERING APPROVED EQUIVALENTS FOR
NON-DEVELOPMENTAL OFF THE SHELF PARTS.
4 BAND MARKINGS:
4.1 BAND MARKINGS SHALL BE SINGLE THERMAL MARKING EMPLOYING
A PERMANENT BLACK MATERIAL. CHARACTERS SHALL BE
VERTICAL GOTHIC TYPE. HEIGHT SHALL BE PROPORTIONAL AND
LEGIBLE.
4.2 BAND SHALL EXTEND PROPORTIONALLY BEYOND LETTERING ON
FRONT AND REAR OF MARKINGS.
5 ENTER MANUFACTURER'S CAGE CODE IN PLACE OF "_ _ _ _ _" IAW
MIL-STD-130.
6 CABLE LENGTHS DETERMINED BY 4-DIGIT DASH NUMBER (i.e.
ALH-123456-0120 IS 120 INCHES).
CABLE TOLERANCE: THE LENGTH OF A CABLE SHALL BE MEASURED
FROM ONE END OF THE CABLE ASSEMBLY TO THE OTHER END
(REFERENCE CABLE ASSEMBLY DIAGRAM). CABLE LENGTH TOLERANCE
SHALL BE AS SHOWN IN THE CABLE LENGTH TOLERANCE TABLE
UNLESS OTHERWISE DEFINED ON THE DRAWING/DOCUMENTATION.
7. CABLES SHALL BE TESTED BY REQUIREMENT TS-1C IDENTIFIED IN
ALH-102546.
8 BAND MARKING ORIENTATION: FOR CABLES LESS THAN OR EQUAL TO
18 INCHES, ONLY ONE CENTER BAND MARKING LABEL "A" IS REQUIRED
ON THE CABLE CENTERED ±.5 INCHES ON THE EXPOSED CABLE
BETWEEN CONNECTORS OR TERMINALS. MARKING LABELS "B" AND "C"
ARE TO BE LOCATED 1" ±.5" FROM BACKSHELL/TERMINAL IN PLACE OF
DIMENSION SHOWN.
9 REPLACE: MM-YYYY WITH MONTH AND YEAR OF MANUFACTURE;
XX WITH DRAWING REVISION USED FOR MANUFACTURE.
10. CABLE PREPARATION, CRIMP TOOL/DIE, AND CONNECTOR/WIRE
ASSEMBLY SHALL BE AS SPECIFIED IN THE INDIVIDUAL CONNECTOR
SPECIFICATIONS OR AS REQUIRED TO MEET THE OVERALL CABLE
ASSEMBLY REQUIREMENTS.
11 FOR ADEQUATE STRAIN RELIEF, THIS AREA MAY REQUIRE ONE OR
MORE LAYER(S) OF FN 3.
2012/08/06
2012/08/06
2012/08/06
W31P4Q-20-R-0015 ATTACHMENT 0022a.1.b
REV.DWG NO.SIZE CAGE CODE
NGMS-ALH8-AC-D04
SCALE NONE SHEET 2 OF 3
Official version of this document is electronically controlled in an online PLM system. Verify version level prior to use.
CABLE ASSEMBLY
A
TABLE
MARKING DESCRIPTION
318U8 ASSY ALH-209032-XXXX
MM-YYYY REV XX MFR _ _ _ _ _
CASS ETHERNET CABLE
A
CASS
B
SEE TABLE
FOR MARKINGS4X
C
AB
RJ45
PLUG
C
LENGTH SHALL BE AS REQUIRED
FOR CABLE ASSEMBLY
2X 2.0±.5 2X 1.0±.5
VIEW A-A
A
A
PIN 1PIN 8
1.0±.5
6 711
REV.DWG NO.SIZE CAGE CODE
NGMS-ALH8-AC-D04
SCALE NONE SHEET 3 OF 3
Official version of this document is electronically controlled in an online PLM system. Verify version level prior to use.
REF
REF
ORANGE/WHITE
GREEN/WHITE
GREEN
ORANGE
WIRING DIAGRAM
DRAIN
BLUE/WHITE
BLUE
BROWN/WHITE
BROWN
File details come from the government source that posted it. Updated .