Attachment 0022a.3 - S280_System Power Analysis_12-5-2017.xlsx

XLSX spreadsheet 69 KB Posted

Attached to
RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
Solicitation number
W31P4Q-20-R-0015
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This document contains equipment power data and specifications for two racks of an Integrated Battle Command System.

The solicitation is for a hardware production effort to produce IBCS hardware end items according to supplied Technical Data Packages and the Critical Item Development Specification. Engineering changes may be required for obsolescence, new capabilities, and export considerations. Questions regarding the solicitation are due by December 10, 2020 at 4pm Central Standard Time. This final RFP is only for contractors who met entrance criteria on Beta.SAM and were approved by the Integrated Fires Mission Command Project Office. The solicitation is issued by the Department of the Army Materiel Command Contracting Command at Redstone Arsenal. Equipment in the two racks includes radios, timing devices, interfaces, power supplies, and lighting, with minimum, maximum, nominal power draws and duty cycles specified.

View the file

Other files for this federal contract opportunity

Other files attached to RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
EXHIBIT A - CONTRACT DATA ITEM REQUIREMENTS LIST (CDRL) - 24NOV2020.pdf PDF
Exhibit C- IBCS DSL - 24NOV2020.docx DOCX document
Attachment 0002 - AIAMD System of Systems (SoS)(MIS-PRF-56500).pdf PDF
Attachment 0004b - Relay Acceptance Test Procedures_FINAL.docx DOCX document
Attachment 0004d - Operator Procedures For IFMC GSIL.docx DOCX document
Attachment 0005 - Software Installation Instructions.docx DOCX document
Attachment 0008 - AIAMD IUID Plan Appendix A - IUID Candidates List Data Items.pdf PDF
Attachment 0009 - R and M Prediction Report.docx DOCX document
Attachment 0010a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.7 – R007 Relay Network Switch-Parvus Switch-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 0010c.3 – E048 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.9 – E059 Shelter Switch – 01-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.8 – E153 RS112 Server -07 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0012 - Risk Management Plan.pdf PDF
Attachment 0013c - IBCS-A301-003 Vol II Instructor Guide_redacted.pdf PDF
Attachment 0013f - D-IBCS-0428-001_Delta_Software_SG_redacted.pdf PDF
Attachment 0013g - D-IBCS-0471_Delta2_Suppl_PE_redacted.pdf PDF
Attachment 0014 RevC - Technical Library.docx DOCX document
Attachment 0016 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 0022a - CASS to PDRS.docx DOCX document
Attachment 0022a.1.e - ALH-215333 00 S-280 CASS INSTALLA.pdf PDF
Attachment 0022a.1.h - PL-ALH-211130 00 CABLE ASSEMBLY C.pdf PDF
Attachment 0022a.4 - CASS Task Purpose.v2.pptx PPTX presentation
Attachment 0025 - DD254.pdf PDF
Attachment 0010b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.5 – R005 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 0013i - D-IBCS-0473_Adv_NetMgr.pdf PDF
Attachment 0023 - IBCS LRIP FRP DO 0001 Pricing Template_22Oct2020.xlsx XLSX spreadsheet
Attachment 0003 - GFP LRIP FRP - 3SEP2020.xlsx XLSX spreadsheet
Attachment 0007 - AIAMD Requirements Prioritization 1-n table.docx DOCX document
Attachment 0010 - FMECA.docx DOCX document
Attachment 0010a.16 – R034 Media Converter Power Supply-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.3 – E005 Blower Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.8 – E032 R112 Shelter – Server Stack – 02-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.9 – E033 R112 Shelter – Server Stack – 03-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.1 – E043 Firewall Red-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.4 – E049 BPU-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.7 – E052 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.14 – E064 Shelter Router Black – FMECA.xlsx XLSX spreadsheet
Attachment 0010d.2 – E144 RWS Bkup Batteries-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.5 – E152 – Media Converter 05-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.9 - E156 UPS - FMECA.xlsx XLSX spreadsheet
Attachment 0010e.2 – E082 thru E091 Wkstn Laptop-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.4 – E102d thru E111 Vid Extender-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.8 – E146 – Table 2 Assembly-FMECA.xlsx XLSX spreadsheet
Show all 50

RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Rack 1

W31P4Q-20-R-0015
ATTACHMENT 0022a.3
TAB 1 of 9

Equipment Power Data Type M = Measured, D = Datasheet

O = OtherMin (RX/idle) WattsMax (TX) WattsDuty CycleNominal WattsMAX Load TotalNominal Load Total
SubsystemDescriptionNetwork ClassMax Watts (120V Side)Max Amps (120V side)Nominal Max WattsNominal Max Amps
DC POWER
VoiceCAU-VCLASSIFIEDD20.020.00.820.01552.062.11316.852.7
VoiceeMCSU (TOCNET)CLASSIFIEDM***10.912.00.811.8
RadiosGMR500CLASSIFIEDD14.014.00.811.2
RadiosKGV-72CLASSIFIEDD15.015.00.812.0
IFCNKG-250XCLASSIFIEDD19.019.00.815.2
TimingTime ServerCLASSIFIEDO50.080.00.874.0
IFCNIGRMCLASSIFIEDD60.060.00.848.0
IFCNBPUCLASSIFIEDD185.0185.00.8148.0
IFCNSCIMCLASSIFIEDD132.0132.00.8105.6
RadiosJBCP Processor & RadioCLASSIFIEDD65.065.00.852.0
RadiosMIDS* LVT-11 Radio (AN/USQ-140(v)2c)CLASSIFIEDD295.0950.00.8819.0
NOTE: DC LOADS ARE POWERED BY THE AC SUBSYSYSTEMS IN THIS RACK (POL-PSU)
AC POWER
PU, Sec.CONSOLE KVMCLASSIFIEDD60.060.00.848.02333.921.22015.018.3
PU, Sec.KVM SWITCH 01 (Lower)CLASSIFIEDD130.0130.00.8104.0
RadiosPIF Cable (MIDS)CLASSIFIEDD18.018.00.814.4
Lighting6x LED Blackout/White LightsUNCLASSD300.0300.01.0300.0
DC PSUDC PSU load to AC system (@85% eff)CLASSIFIEDD1018.71825.91.21548.6
*Nominal DC voltage design is 25VDC to comply with MIL-STD-1275D's S-S allowable voltage of 25-30 VDC.
**Nominal AC voltage design is 110V from MIL-STD-1332B class 2C S-S voltage of 110V-120V phase-neutral
***Nominal Watts (and current) is calculated by Min+DC*(Max-Min) for devices where min/max are not the same
CONSTANTS
Min Nominal DC Volts:
25
Min Nominal AC Volts:
110

Rack 2

W31P4Q-20-R-0015
ATTACHMENT 0022a.3
TAB 2 of 9

Equipment Power Data Type M = Measured, D = Datasheet

O = OtherMin (RX/idle) WattsMax (TX) WattsDuty CycleNominal WattsMAX Load TotalNominal Load Total
SubsystemDescriptionNetwork ClassMax Watts (120V Side)Max Amps (120V side)Design Max WattsDesign Max Amps
DC POWER
RadiosRF-300M-V250(1) (2x AN/PRC-117G)CLASSIFIEDD600.0600.00.5480.02107.284.31685.867.4
RadiosRF-300M-V250(1) (2x AN/PRC-117G)CLASSIFIEDD600.0600.00.5480.0
RadiosTACLINK 3100CLASSIFIEDD4.04.00.83.2
RadiosJTT-IBX* p/o AN/URC-145 (V)1CLASSIFIEDD201.6201.60.8161.3
RadiosJTT-EPA* p/o AN/URC-145 (V)1CLASSIFIEDD504.0504.00.8403.2
RadiosJTT-IBX* p/o AN/URC-145 (V)1CLASSIFIEDD201.6201.60.8161.3
NOTE: DC LOADS ARE POWERED BY THE AC SUBSYSYSTEMS IN THIS RACK (POL-PSU)
AC POWER
MDPNET GUARDIAN 16ACLASSIFIEDD20.020.00.816.02503.822.82003.018.2
DC PSUDC PSU load to AC system (@85% eff)CLASSIFIEDD2483.82483.8N/A1987.0
*Nominal DC voltage design is 25VDC to comply with MIL-STD-1275D's S-S allowable voltage of 25-30 VDC.
**Nominal AC voltage design is 110V from MIL-STD-1332B class 2C S-S voltage of 110V-120V phase-neutral
<--This type of highlighting denotes components that need further investigation as datasheet values appear excessive
CONSTANTS
Min Nominal DC Volts:
25
Min Nominal AC Volts:
110

Rack 3

W31P4Q-20-R-0015
ATTACHMENT 0022a.3
TAB 3 of 9

Equipment Power Data Type M = Measured, D = Datasheet

O = OtherMin (RX/idle) WattsMax (TX) WattsDuty CycleNominal WattsMAX Load TotalNominal Load Total
SubsystemDescriptionNetwork ClassMax Watts (120V Side)Max Amps (120V side)Design Max WattsDesign Max Amps
DC POWER
RadiosEPLRS (AN/VSQ-2(v)2) with UROCLASSIFIEDM17.417.40.813.975.03.060.02.4
RadiosCASSCLASSIFIEDD75.075.00.860.0
NOTE: DC LOADS ARE POWERED BY THE AC SUBSYSYSTEMS IN THIS RACK (POL-PSU)
AC POWER
OperatorUSB Jackbox - Operator 1CLASSIFIEDD18.018.00.814.41914.217.41658.215.1
OperatorUSB Jackbox - Operator 2CLASSIFIEDD18.018.00.814.4
OperatorTL-354 Display - Operator 1CLASSIFIEDD90.090.00.872.0
OperatorTL-354 Display - Operator 2CLASSIFIEDD90.090.00.872.0
OperatorPrinterCLASSIFIEDD50.050.00.840.0
RadiosADSI 3UCLASSIFIEDO***156.0300.00.8271.2
OperatorGetac X500 - NW MGTCUID***48.065.00.861.6
LANMedia Converter ChassisCUID20.020.00.816.0
LAN, Sec.Cisco 4321 ISO RouterCUID125.0125.00.8100.0
LAN, Sec.Cisco 4351 Router with Switch ModuleCUID430.0430.00.8430.0
LAN, Sec.Cisco FirewallCUIM/D120.0120.00.896.0
LANAlarm AmplifierCUIO500.0500.00.8400.0
DC PSUDC PSU load to AC system (@85% eff)CLASSIFIEDD88.288.2N/A70.6
*Nominal DC voltage design is 25VDC to comply with MIL-STD-1275D's S-S allowable voltage of 25-30 VDC.
**Nominal AC voltage design is 110V from MIL-STD-1332B class 2C S-S voltage of 110V-120V phase-neutral
***Nominal Watts (and current) is calculated by Min+DC*(Max-Min) for devices where min/max are not the same
<--This type of highlighting denotes components that need further investigation as datasheet values appear excessive
CONSTANTS
Min Nominal DC Volts:
25
Min Nominal AC Volts:
110

Rack 4

W31P4Q-20-R-0015
ATTACHMENT 0022a.3
TAB 4 of 9

Equipment Power Data Type M = Measured, D = Datasheet

O = OtherMin (RX/idle) WattsMax (TX) WattsDuty CycleNominal WattsMAX Load TotalNominal Load Total
SubsystemDescriptionNetwork ClassMax Watts (120V Side)Max Amps (120V side)Design Max WattsDesign Max Amps
AC POWER
LAN, Pri.Cisco Switch 02CLASSIFIEDD281.0281.00.8224.84563.041.54006.836.4
LAN, Pri.Cisco Switch 01CLASSIFIEDD281.0281.00.8224.8
LAN, Pri.Cisco FirewallCLASSIFIEDM120.0120.00.896.0
LAN, Pri.Cisco 4321 ISO RouterCLASSIFIEDD125.0125.00.8100.0
LAN, Pri.Cisco 4351 Router with Switch ModuleCLASSIFIEDM430.0430.00.8344.0
LANMedia Converter Chassis 02CLASSIFIEDD64.070.00.856.0
LANCross Domain SolutionCLASSIFIEDO-MFG-EMAIL28.028.00.822.4
OperatorRS-11x Workstation 02CLASSIFIEDO-MFG-EMAIL***198.0459.00.8406.8
OperatorRS-11x Workstation 01CLASSIFIEDO-MFG-EMAIL***198.0459.00.8406.8
PU, Sec.RS-112 BS Server 02CLASSIFIEDO-MFG-EMAIL***198.0330.00.8303.6
PU, Sec.RS-112 BS Server 01CLASSIFIEDO-MFG-EMAIL***198.0330.00.8303.6
PU, Sec.RS-112 VM Server 02CLASSIFIEDO-MFG-EMAIL***198.0330.00.8303.6
PU, Sec.RS-112 VM Server 01CLASSIFIEDO-MFG-EMAIL***198.0330.00.8303.6
PFPURS-112 Stand-in Server 03CLASSIFIEDO-MFG-EMAIL***198.0330.00.8303.6
PFPURS-112 Stand-in Server 02CLASSIFIEDO-MFG-EMAIL***198.0330.00.8303.6
PFPURS-112 Stand-in Server 01CLASSIFIEDO-MFG-EMAIL***198.0330.00.8303.6
**Nominal AC voltage design is 110V from MIL-STD-1332B class 2C S-S voltage of 110V-120V phase-neutral
***Nominal Watts is Min/STBY+DC*(max-min) for devices where min/max are not the same
CONSTANTSNotes:
Min Nominal DC Volts:SM server rack similar to this one pulls 1KVA at idle (~100w/server)
25Server Power estimate data from Crystal:

-CMS-00500 is 330W peak and 198W nominal -CMS-00310/245 (old variants) use 314 peak and 188 nominal -workstations are 459 based on engineering analysis (have not benchmarked actual hardware yet)

Min Nominal AC Volts:
110

System Loads

W31P4Q-20-R-0015
ATTACHMENT 0022a.3
TAB 5 of 9
AC Watts
Non-Racked Loads:<--these input to rest of the sheets
Lighting*300These don't auto-update
GPFU510
ECS10800
Mast Motor600
Total Watts12,210.00
Amps/leg on 208V side for large-non-racked loads21.36
*Lighting is .5A per light @ 120V
*Lighting is powered from SP or Rack1 via Automatic Transfer Switch

Shelter Total

W31P4Q-20-R-0015
ATTACHMENT 0022a.3
TAB 6 of 9
EQUIPMENTAC Loading (amps are 'per phase' on the 208 side and UPS eff effect incorporated where applicable)
Max WattsMaxAmps(A)MaxAmps(B)MaxAmps(C)Nominal WattsNominalAmps(A)NominalAmps(B)NominalAmps(C)
Rack 12,745.84.84.84.81,549.22.72.72.7
Rack 22,945.65.25.25.22,356.54.14.14.1
Rack 32,252.03.93.93.91,950.83.43.43.4
Rack 45,368.29.49.49.44,713.98.28.28.2
Mast Motor600.01.01.01.0600.01.01.01.0
GCU510.00.90.90.9510.00.90.90.9
ECU10,800.018.918.918.910,800.018.918.918.9
EST TOTALS (pf@1)
Racks:13,311.724.324.324.310,570.418.518.518.5
Shelter11,910.020.820.820.811,910.020.820.820.8
ALL:25,221.744.144.144.122,480.439.339.339.3
<-- BIG CHANGE: We can use the 60A shore power cable and still have over 30% margin. -->
UPS efficiency is assumed to be:85%(Does not include current to charge batteries)
The mast motor and ECU compressor/fan are probably 0.8pf or worse, depending on speed/load, but are assumed to be 1 for estimations as they are small compared to heating elemnts and electronic loads
Old Calculations that are hard to understand, but should still auto-update with new data:
RackLoad Total DCLoad Total ACTotal AC AmpsTotal AC WattsNetwork Power Analysis
Design Max WattsDC Supply
WattsDesign Max AmpsAC/DC Supply
AmpsDesign Max WattsDesign Max AmpsTotal AC
WattsTotal DC
WattsRack Total

Watts

11316.821549.2052.6714.082014.9818.3232.403564.172014.981316.823331.79
21685.761983.2567.4318.032003.0118.2136.243986.262003.011685.763688.77
360.0070.592.400.641658.192.403.04334.591658.1960.001718.19
40.000.000.000.004006.8036.4336.434006.804006.800.004006.80
Total3062.583603.03122.5032.759682.9875.35Rack Total11891.82Rack Total12745.55
W/S Wattage346.00346.00
Shelter Lighting360.00360.00
Shelter Total12597.8213451.55
CONSTANTSShelter Total Amps114.53122.29
Min Nominal DC Volts:Per Phase38.1840.76
25
Min Nominal AC Volts:
110
Min S-S AC L-L Volts
190.5

System Total

W31P4Q-20-R-0015
ATTACHMENT 0022a.3
TAB 7 of 9
Total AC Watts
Shelter12597.82
GPFU510.00
ECS10800.00
Mast Motor600.00
System Total Watts24507.82
System Total Amps85.03

2ePFPUrack4

W31P4Q-20-R-0015
ATTACHMENT 0022a.3
TAB 8 of 9

Equipment Power Data Type M = Measured, D = Datasheet

O = OtherMin (RX/idle) WattsMax (TX) WattsDuty CycleNominal WattsMAX Load TotalNominal Load Total
SubsystemDescriptionNetwork ClassMax Watts (120V Side)Max Amps (120V side)Design Max WattsDesign Max Amps
AC POWER
LAN, Pri.Cisco Switch 02CLASSIFIEDO133.60133.600.80106.884800.2043.644694.5642.68
LAN, Pri.Cisco Switch 01CLASSIFIEDO133.60133.600.80106.88
LAN, Pri.Cisco FirewallCLASSIFIEDM120.00120.000.8096.00
LAN, Pri.Cisco 2901 ISO RouterCLASSIFIEDD***40.0050.000.8048.00
LAN, Pri.Cisco 2951 Router with Switch ModuleCLASSIFIEDM100.00100.000.8080.00
LANMedia Converter Chassis 02CLASSIFIEDD***64.0070.000.8068.80
LANCross Domain SolutionCLASSIFIEDD25.0025.000.8020.00
OperatorRS-114 Workstation 02CLASSIFIEDO-MFG-EMAIL198.00459.001.00459.00
OperatorRS-114 Workstation 01CLASSIFIEDO-MFG-EMAIL198.00459.001.00459.00
PU, Sec.RS-112 BS Server 02CLASSIFIEDO-MFG-EMAIL198.00330.001.00330.00
PU, Sec.RS-112 BS Server 01CLASSIFIEDO-MFG-EMAIL198.00330.001.00330.00
PU, Sec.RS-112 VM Server 02CLASSIFIEDO-MFG-EMAIL198.00330.001.00330.00
PU, Sec.RS-112 VM Server 01CLASSIFIEDO-MFG-EMAIL198.00330.001.00330.00
PFPURS-112 Stand-in Server 03CLASSIFIEDD198.00330.001.00330.00
PFPURS-112 Stand-in Server 02CLASSIFIEDO-MFG-EMAIL198.00330.001.00330.00
PFPURS-112 Stand-in Server 01CLASSIFIEDD198.00330.001.00330.00
PU, Sec.ePFPU#1CLASSIFIEDO-MFG-EMAIL500.00800.001.00800.00
PU, Sec.ePFPU#2CLASSIFIEDO-MFG-EMAIL500.00800.001.00800.00
**Nominal AC voltage design is 110V from MIL-STD-1332B class 2C S-S voltage of 110V-120V phase-neutral
***Nominal Watts is Min/STBY+DC*(max-min) for devices where min/max are not the same
CONSTANTSNotes:
Min Nominal DC Volts:SM server rack similar to this one pulls 1KVA at idle (~100w/server)
25Server Power estimate data from Crystal:

-CMS-00500 is 330W peak and 198W nominal -CMS-00310/245 (old variants) use 314 peak and 188 nominal

Min Nominal AC Volts:
110
Old rack without ePFPU was4563.00watts41.48amps
upper is237.2watts2.16amps

3ePFPUrack4

W31P4Q-20-R-0015
ATTACHMENT 0022a.3
TAB 9 of 9

Equipment Power Data Type M = Measured, D = Datasheet

O = OtherMin (RX/idle) WattsMax (TX) WattsDuty CycleNominal WattsMAX Load TotalNominal Load Total
SubsystemDescriptionNetwork ClassMax Watts (120V Side)Max Amps (120V side)Design Max WattsDesign Max Amps
AC POWER
LAN, Pri.Cisco Switch 02CLASSIFIEDO133.60133.600.80106.885170.2047.005063.7646.03
LAN, Pri.Cisco Switch 01CLASSIFIEDO133.60133.600.80106.88
LAN, Pri.Cisco FirewallCLASSIFIEDM120.00120.000.8096.00
LAN, Pri.Cisco 2901 ISO RouterCLASSIFIEDD40.0050.000.8040.00
LAN, Pri.Cisco 2951 Router with Switch ModuleCLASSIFIEDM100.00100.000.8080.00
LANMedia Converter Chassis 02CLASSIFIEDD64.0070.000.8056.00
LANCross Domain SolutionCLASSIFIEDD25.0025.000.8020.00
OperatorRS-112 Workstation 02CLASSIFIEDO-MFG-EMAIL198.00459.001.00459.00
OperatorRS-112 Workstation 01CLASSIFIEDO-MFG-EMAIL198.00459.001.00459.00
PU, Sec.RS-112 BS Server 02CLASSIFIEDO-MFG-EMAIL198.00330.001.00330.00
PU, Sec.RS-112 BS Server 01CLASSIFIEDO-MFG-EMAIL198.00330.001.00330.00
PU, Sec.RS-112 VM Server 02CLASSIFIEDO-MFG-EMAIL198.00330.001.00330.00
PU, Sec.RS-112 VM Server 01CLASSIFIEDO-MFG-EMAIL198.00330.001.00330.00
PFPURS-112 Stand-in Server 03CLASSIFIEDO-MFG-EMAIL198.00330.001.00330.00
PFPURS-112 Stand-in Server 02CLASSIFIEDO-MFG-EMAIL198.00330.001.00330.00
PFPURS-112 Stand-in Server 01CLASSIFIEDO-MFG-EMAIL198.00330.001.00330.00
PFPUePFPU#1CLASSIFIEDO-MFG-EMAIL500.00800.001.00800.00
PFPUePFPU#2CLASSIFIEDO-MFG-EMAIL500.00800.001.00800.00
PFPUePFPU#3CLASSIFIEDO-MFG-EMAIL500.00800.001.00800.00
**Nominal AC voltage design is 110V from MIL-STD-1332B class 2C S-S voltage of 110V-120V phase-neutral
Notes:MAX LOAD
SM server rack similar to this one pulls 1KVA at idle (~100w/server)UPS#1
Server Power estimate data from Crystal:UPS#2
-CMS-00500 is 330W peak and 198W nominalUPS#3
-CMS-00310/245 (old variants) use 314 peak and 188 nominal
Old rack without ePFPU was4563.00watts41.48amps
upper is607.2watts5.52amps

RefWireAmpacity Wire Size (AWG) '975 Derated Current (Amperes) NEC Ampacity Based on Circular Mils @ 20C (100% pure copper) Watts per 10 feet at XX amps (RMS for AC) This is PER CONDUCTOR/RUN

Single WireBundled Wire or CableUp to 3 Wire-BundleOhms/1k-Ft@25COHMS/1k-FT@50C0.250.511.522.53456793045
301.30.7---105.2115.40.0720.2891.1542.5974.6167.21310.38618.46428.85041.54456.54693.4741038.6002336.850
281.81---66.1772.550.0450.1810.7261.6322.9024.5346.53011.60818.13826.11835.55058.766652.9501469.138
262.51.4---41.6245.630.0290.1140.4561.0271.8252.8524.1077.30111.40816.42722.35936.960410.670924.008
243.32---26.1728.70.0180.0720.2870.6461.1481.7942.5834.5927.17510.33214.06323.247258.300581.175
224.52.5---16.4618.050.0110.0450.1810.4060.7221.1281.6252.8884.5136.4988.84514.621162.450365.513
206.53.7---10.3511.350.0070.0280.1140.2550.4540.7091.0221.8162.8384.0865.5629.194102.150229.838
189.25---6.517.140.0040.0180.0710.1610.2860.4460.6431.1421.7852.5703.4995.78364.260144.585
16136.5---4.0944.4890.0030.0110.0450.1010.1800.2810.4040.7181.1221.6162.2003.63640.40190.902
14198.5202.5752.8230.0020.0070.0280.0640.1130.1760.2540.4520.7061.0161.3832.28725.40757.166
122511.5251.6191.7730.0010.0040.0180.0400.0710.1110.1600.2840.4430.6380.8691.43615.95735.903
103316.5301.0181.1170.0010.0030.0110.0250.0450.0700.1010.1790.2790.4020.5470.90510.05322.619
84423400.64050.70230.0000.0020.0070.0160.0280.0440.0630.1120.1760.2530.3440.5696.32114.222
66030550.40280.44160.0000.0010.0040.0100.0180.0280.0400.0710.1100.1590.2160.3583.9748.942
48140700.25330.27780.0000.0010.0030.0060.0110.0170.0250.0440.0690.1000.1360.2252.5005.625
210850950.15930.17470.0000.0000.0020.0040.0070.0110.0160.0280.0440.0630.0860.1421.5723.538
0147751250.10020.10990.0000.0000.0010.0020.0040.0070.0100.0180.0270.0400.0540.0890.9892.225
0016987.51450.0790.087120.0000.0000.0010.0020.0030.0050.0080.0140.0220.0310.0430.0710.7841.764

File details come from the government source that posted it. Updated .