Attachment 0003 - Jack Stand Assembly SPI 1.pdf
PDF 290 KB Posted
- Attached to
- Rough Terrain Container Handler (RTCH) Field Level Tools Kits (FLTKs) Federal contract opportunity
- Solicitation number
- W56HZV20R0255
View the file
Other files for this federal contract opportunity
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 1 of 10 Pages
SPECIAL PACKAGING INSTRUCTION
Form Approved OMB No. 0704-0188
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CAGE 3. SPI NO.
2016JSK (19207) JACK STAND ASSEMBLY 19207 AK16662659
4. NATIONAL STOCK NO. 5. DATE 6. REVISION
4910-01-666-2659 08/05/2019 -
7. QUP 8. ICQ 9. UNIT PACK WT (LB.) 10. UNIT PACK CU (CU. FT.) 11. UNIT PACK SIZE (INCHES)
1 EACH 001 1163.0 86.528 56.0 x 44.5 x 60
12. MILITARY PRESERVATION 18.
STEPS
19.
REQD
20.
DESCRIPTION MIL-STD-2073-1, Method 10
13. CLEANING 1 A/R Item Contents: See Note C
MIL-STD-2073-1 2 A/R Item Preparation See Note D & E
14. DRYING 3 A/R Item Consolidation See Note F - I
MIL-STD-2073-1
15. PACKING
a. LEVEL A
MIL-STD-2073-1
b. LEVEL B
NONE
16. MARKING
MIL-STD-129
17. NOTES/ DRAWING
A. PRESERVATION AND PACKAGING SHALL BE INSPECTED IN ACCORDANCE WITH MIL-STD-2073-1D AND ANY
APPLICABLE CONTAINER SPECIFIATIONS.
B. CLEAN AND DRY ITEM BY ANY SUITABLE PROCESS BEFORE APPLICATION OF PRESERVATIVE AND PACKAGING
MATERIALS.
C. PART NUMBER 2016JSK, JACKSTAND ASSEMBLY, QTY1, CONSISTS OF THE FOLLOWING:
ITEM NO. PART NUMBER DESCRITPION QTY
1 396-9840 CYLINDER ASSEMBLY 2
2 8S7625 COLLAR, SHAFT 2
3 8S8048 SADDLE ASSEMBLY, LIFTING BLOCK 2
4 8S7620 BASE ASSEMBLY 2
5 8S7621 REPAIL TOOL, SPECIAL TOOL 33.25-40.5 IN AND BLOCK 2
6 8S7615 PIN, SHOULDER 6
7 350-7768 PUMPING UNIT, HYDRAULIC 1
EP-0024149 ADAPTER *assemble on Hydraulic pump, see instructions in kit 1 GA-3 ADAPTER *assemble on Hydraulic pump, see instructions in kit 1 G2535L GAGE, PRESSURE, DIEL 0-10,000PSI*assemble on Hydraulic pump, instructions in kit 1 EP-0024150 NIPPLE, PIPE METRIC X JIC *assemble on Hydraulic pump, see instructions in kit 1
8 & 9 8F0024 HOSE ASSEMBLY 2
8S7645 HOSE, NONMETALLIC*part of hose assembly 1 1P2376 COUPLING ASSEMBLY, QUICK DISCONNECT FEMALE *part of hose assembly 2 5S2403 PIPE, REDUCER *assemble on hose assembly, instructions in kit 1 0038470 TEE, PIPE *assemble on hose assembly, instructions in kit 1 3B7722 BUSHING, PIPE *assemble on hose assembly, instructions in kit 1
10 HF101 LUBRICATING OIL, HYD GALLON 1
11 REPAIR TOOL, SPECIAL TOOL 24 IN AND BLOCK 2
12 4C6486 STAND, LIFITING AND JACK STAND BASE 2
D. DEVELOP WOODEN INSERT IN ACCORDANCE WITH ASTM D6251, TYPE III, CLASS 2, STYLE A1. SEE TABLE 1 AND
FIGURES 1 AND 2 FOR SIZE AND ORIENTATION OF INSERT.
E. DEVELOP FOAM INSERTS IN ACCORDANCE WITH A-A-59136, TYPE I. SEE FIGURE 3 FOR SIZE AND ORIENTATION OF
FOAM INSERT.
SPECIAL PACKAGING INSTRUCTION Form Approved
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CAGE 3. SPI NO.
2016JSK (19207) Jack Stand Assembly 19207 AK16662659
4. NATIONAL STOCK NO. 5. DATE 6. REVISION
4910-01-666-2659 08/05/2019 -
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 2 of 10 Pages
F. CONOSLIDATE ITEM NO. 1-10 IN KIT CONTENT TABLE INTO WOODEN INSERT PER LOCATION SHOWN IN FIGURE 4.
G. CLOSE WOODEN INSERT IN ACCORDANCE WITH ASTM D6251.
H. PLACE JACK STANDS ON TOP OF WOODEN INSERT AND USE 2 RATCHET TIE DOWN STRAPS (P/N 340700) TO SECURE TO INSERT. SEE FIGURE 5 FOR ORIENTATION. STRETCH WRAP WOODEN INSERT TO INCLUDE THE JACK STANDS.
I. PLACE WOODEN INSERT WITH JACK STANDS STRAPPED ON TOP, INSIDE ASTM D7478, TYPE II, CLASS 2 STYLE A CONTAINER AND CLOSE IN ACCORDANCE WITH ASTM D7478. INTERNAL DIMENSIONS ARE 54.0” X 43.5” X 53.5”
TABLE 1 – BILL OF MATERIAL
ITEM SIZE QTY REFERENCE
1 0.75” X 20.5” X 52.125 2 ASTM D6199
2 0.75” X 20.5” X 43.0” 2 ASTM D6199
3 0.75” X 19.75” X 41.5” 2 ASTM D6199
4 0.75” X 19.75” X 20.25” 3 ASTM D6199
5 0.75” X 19.75” X 12” 1 ASTM D6199
6 0.75” X 19.75” X 14.875” 1 ASTM D6199
7 0.75” X 19.75” X 28.75” 1 ASTM D6199
8 0.75” X 19.75” X 13” 1 ASTM D6199
9 0.75” X 19.75” X 1.75” 2 ASTM D6199
10 0.75” X 19.75” X 3.25” 4 ASTM D6199
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CAGE 3. SPI NO.
2016JSK (19207) Jack Stand Assembly 19207 AK16662659
4. NATIONAL STOCK NO. 5. DATE 6. REVISION
4910-01-666-2659 08/05/2019 -
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 3 of 10 Pages
FIGURE 1: LOCATION OF BLOCKING AND BRACING.
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CAGE 3. SPI NO.
2016JSK (19207) Jack Stand Assembly 19207 AK16662659
4. NATIONAL STOCK NO. 5. DATE 6. REVISION
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 4 of 10 Pages
FIGURE 2: ORIENTATION OF BLOCKING AND BRACING.
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CAGE 3. SPI NO.
2016JSK (19207) Jack Stand Assembly 19207 AK16662659
4. NATIONAL STOCK NO. 5. DATE 6. REVISION
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 5 of 10 Pages
FIGURE 3: DETAILS FOR EACH FOAM CUTOUT AND LOCATION WITHIN INSERT.
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CAGE 3. SPI NO.
2016JSK (19207) Jack Stand Assembly 19207 AK16662659
4. NATIONAL STOCK NO. 5. DATE 6. REVISION
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 6 of 10 Pages
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CAGE 3. SPI NO.
2016JSK (19207) Jack Stand Assembly 19207 AK16662659
4. NATIONAL STOCK NO. 5. DATE 6. REVISION
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 7 of 10 Pages
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CAGE 3. SPI NO.
2016JSK (19207) Jack Stand Assembly 19207 AK16662659
4. NATIONAL STOCK NO. 5. DATE 6. REVISION
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 8 of 10 Pages
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CAGE 3. SPI NO.
2016JSK (19207) Jack Stand Assembly 19207 AK16662659
4. NATIONAL STOCK NO. 5. DATE 6. REVISION
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 9 of 10 Pages
FIGURE 4: LOCATION OF SPECIAL TOOLS WITHIN WOODEN INSERT
Item No. 11, REPAIR TOOL, SPECIAL TOOL 24 IN AND BLOCK has a QTY of 2 and is placed in section 5 on top of the longer tube.
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CAGE 3. SPI NO.
2016JSK (19207) Jack Stand Assembly 19207 AK16662659
4. NATIONAL STOCK NO. 5. DATE 6. REVISION
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 10 of 10 Pages
FIGURE 5: JACK STAND ORIENTATION ON WOODEN INSERT