This document is a Scope of Work (SOW) for a Blanket Purchase Agreement (BPA) for lumber and power poles. The SOW details specific lumber requirements including hardwood lumber (various sizes of untreated lumber ranging from 1x4 to 1x8, with precise dimensional specifications) and dimensional softwood lumber (construction grade HT lumber in various lengths and sizes), as well as power poles in 35', 40', and 45' Class 3 configurations. Additional requirements include government quality assurance inspection, with contractors responsible for replacing or repairing any materials that do not meet specified drawings and MIL-SPEC standards, and mandating that contractors provide a Certificate of Conformance (COC) and Certified Test Report demonstrating compliance with all technical data requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Scope of Work

1. BPA Holders in accordance with “Attachment 0001” general scope of material is listed below to be ordered against BPAs but is not limited to:

Hardwood Lumber

□ Lumber, Untreated 1x4. Cut to 3 ½ inches wide plus or minus 1/16 inch. 35 inches long plus 1/8 inch or minus ¼ inch. Thickness ¾ inch plus or minus 1/16 inch.

□ Lumber, Untreated 1x4. Cut to 3 ½ inches wide plus 0 inches or minus 1/4 inch. 45 1/2 inches long plus 1/8 inch or minus ¼ inch. Thickness ¾ inch plus or minus 1/16 inch.

□ Lumber, Untreated 1x6. Cut to 5 ½ inches wide plus 0 inches or minus 1/4 inch. 45 1/2 inches long plus 1/8 inch or minus ¼ inch. Thickness ¾ inch plus or minus 1/16 inch.

□ Lumber, Untreated 1x8. Cut to 7 1/4 inches wide plus or minus 1/16 inch.

35 inches long plus 1/8 inch or minus ¼ inch. Thickness ¾ inch plus or minus 1/16 inch

□ Lumber, Untreated 1x8. Cut to 7 1/4 inches wide plus 0 inches or minus 1/4 inch. 45 1/2 inches long plus 1/8 inch or minus ¼ inch. Thickness ¾ inch plus or minus 1/16 inch.

□ Lumber, Untreated 1x4. Cut to 3 ½ inches wide plus or minus 1/16 inch. 40 inches long plus 1/8 inch or minus ¼ inch. Thickness ¾ inch plus or minus 1/16 inch.

□ Lumber, Untreated 1x4. Cut to 3 ½ inches wide plus 0 inches or minus 1/4 inch. 48 inches long plus 1/8 inch or minus ¼ inch.

□ Lumber, Untreated 1x6. Cut to 5 ½ inches wide plus 0 inches or minus 1/4 inch. 48 inches long plus 1/8 inch or minus ¼ inch.

□ Lumber, Untreated 1x8. Cut to 7 1/4 inches wide plus or minus 1/16 inch.

40 inches long plus 1/8 inch or minus ¼ inch. Thickness ¾ inch plus or minus 1/16 inch

□ Lumber, Untreated 4x3. Cut to 3 5/8 inches wide plus or minus 1/16 inch.

48 inches long plus 1/8 inch or minus ¼ inch. Thickness 2 3/4 inch plus or minus 1/16 inch.

Dimensional Softwood Lumber

□ 2" X 4" X 10' Construction Grade HT Lumber

□ 2" X 8" X 8' Construction Grade HT Lumber

□ 4 x 4 x 8' Construction Grade HT Lumber

□ 2 x 6 x 8' Construction Grade HT Lumber

□ 2" X 6" X 10' Construction Grade HT Lumber

□ 1/2" AC Plywood, 4' X 8' Sheets

□ 1/2" AC Plywood, 4' X 8' Sheets

□ 3/4" AC Plywood, 4' x 8'

□ 1 x 6 x 8', Construction Grade HT Lumber

□ 1 x 4 x 8', Construction Grade HT Lumber

□ 2 x 8 x 8', Construction Grade HT Lumber

□ 2 x 4 x 16', Construction Grade HT Lumber

□ 2 x 6 x 16', Construction Grade HT Lumber

Power Poles

□ 35’ Class 3

□ 40’ Class 3

□ 45’ Class 3

Other Requirements

1. All material will be inspected through Governments Quality Assurance (QA) Department. All parts that do not meet the specifications listed per the provided drawing(s) and the MIL-SPEC required in said drawing(s), will be replaced/ repaired by the contractor at their cost to include all shipping cost incurred for the defective parts.

2. Contractor shall provide Certificate of Conformance (COC) and Certified Test Report for all processes indicating contractor compliance with all associated tech data requirements.