This document is an attachment outlining the requirements for a District Plan, which is a comprehensive planning document for a federal installation. The plan must be structured in six major sections: an introduction with vicinity graphics describing the district's purpose and characteristics; alignment with the overall Installation Development Plan; district analysis covering planning strategies, constraints and opportunities (utilizing a red, yellow, green measurable analysis with supporting graphics), developable areas, and a regulating plan; program analysis including capacity plans, condition/configuration assessments, and requirements prioritization; alternative analysis; and findings and recommendations with a detailed illustrative graphic. The final illustrative graphic must show sufficient detail regarding building footprints, setbacks, new construction, demolition, renovation, transportation arrangements, parking, pedestrian circulation, landscaping, open space, and utility requirements.
The document specifies that the Architect-Engineer (A-E) contractor must incorporate hypertext links to relevant plan sections, obtain and include digital photographs from the installation photo lab, take additional site photographs, and obtain installation POC approval for all photographs. Government-furnished items include GIS Mission Data Sets, Sustainment Management System data, Mission Dependency Index information, real property inventory, stakeholder and facility manager lists, unit manning documents or facility space authorizations, organizational charts, open work orders, programmed projects (funded, approved, and future), life/health/safety violations, planning waivers, cultural resource and historic building listings, and Transportation Management Plan improvements. The contractor must review these materials and other planning documents to incorporate specific recommendations and identify concerns.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 3 – Outline of the District Plan
1. Introduction (including purpose and District description) with vicinity graphic
2. Relationship to Overall Installation Development Plan
3. District Analysis
a. Planning Strategies
b. Constraints and Opportunities* with constraints and opportunities graphic utilizing measurable analysis (red, yellow, green)
c. Developable Areas
d. Regulating Plan
4. Program Analysis
a. Capacity Plan
b. Condition/Configuration
c. Requirements Prioritization
5. Alternative Analysis
6. Findings and Recommendations with final Illustrative graphic.**
* Shall include hypertext links to appropriate Plan section for more information and appropriate photos, maps, and graphics to add Plan context. The A-E will obtain digital photographs from the installation photo lab and shall also take photographs that are to be included or considered for use in the document or associated briefings. All photos will be provided to and approved by the installation POC.
** Shall be sufficiently detailed to show building footprints, building setbacks, new construction, demolition, renovation, transportation arrangements, parking areas, pedestrian circulation, landscaping, open space, and significant utility requirements.
Government Furnished Items (GFI)
• GIS Mission Data Sets (MDS) for planning
• Sustainment Management System (SMS) (Builder & Paver)
• Tactical Mission Dependency Index (MDI) or traditional MDI
• Real property inventory
• Customer (Stakeholder) List / Facility manager listing o Unit Manning Document: this may not be need if facility space authorizations have been calculated o Organizational chart (or phone rosters)
• Open work orders
• Programmed Projects, to include funded, approved, and future projects
• Life, Health, or Safety Violations on facilities, such as RAC Code or Fire Safety Deficiency (FSD)
• Planning Waivers, such as airfield criteria waivers or facilities in violation of an explosive safety zone
• Review of other planning documents and the IDP for specific recommendation and concerns o Listing of cultural resource sites o Listing of historic buildings o Traffic management improvements in the Transportation Management Plan
File details come from the government source that posted it. Updated .