Attach 1 - Neiber Fire Fences SOW.pdf

PDF 213 KB Posted

Attached to
NEIBER FIRE FENCES Federal contract opportunity
Solicitation number
140L0621R0007
Issued by
Department of the Interior Bureau of Land Management National Office

About this file

This document package includes specifications for a federal contract to construct Neiber Fire Fences in Washakie County, Wyoming. The contractor will be required to remove approximately 22 miles of four-wire fence and 5 miles of woven wire fence, along with various panels and gates. New fencing requirements include constructing approximately 28 miles of four-wire fence, 250 stress panels, 132 end panels, 45 corner panels, and 60 gates. The specifications provide details on materials, preparation, installation, measurement, payment procedures and a work data sheet outlining fence locations and dimensions. The related federal contract opportunity is solicitation number 140L0621R0007 for Neiber Fire Fences being offered through the Department of the Interior Bureau of Land Management National Office.

View the file

Other files for this federal contract opportunity

Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Neiber Fire Fences

TABLE OF CONTENTS

Section 01009 General Information and Requirements Part 1: General

PART 2: PRODUCTS

PART 3: EXECUTION

PART 4: MEASUREMENT AND PAYMENT

Section 02827 Fence Removal

PART 1: GENERAL

PART 2: PRODUCTS

PART 3: EXECUTION

PART 4: MEASUREMENT AND PAYMENT

Section 02824 Wire Fences and Gates

PART 1: GENERAL

PART 2: PRODUCTS

PART 3: EXECUTION

PART 4: MEASUREMENT AND PAYMENT

WORK DATASHEET

Apr-21

General Information and Requirements 01009-2

SECTION 01009

GENERAL INFORMATION AND REQUIREMENTS

PART 1: GENERAL

1.1 SUMMARY:

A. Description of Work:

1. Fence Removal

a. Furnishing labor and equipment to remove approximately 22 miles of four wire fence and approximately 5 miles of woven wire fence, this should include approximately 100 stress panels, 60 wire gates, 45 corner panels, 122 end panels and 147,840 feet of wire.

2. Fence Construction

a. Construct approximately 28 miles of four wire fence, up to 250 Stress panels, 60 wire gates, 45 corner panels, and 132 end panels.

B. Work Data Sheet: Designates the type and quantity of work required at the project location, and dimensions required for typical drawings.

C. Removed Materials: Debris consisting of wood posts, steel posts, panels, wire gate assemblies, solar powered energizers and wire fence shall become the property of the BLM and shall be removed from the work site and disposed of in a legal fashion.

1.2 REFERENCES

A. Referenced Specifications/Standards with Abbreviations and/or Acronyms: Wherever the following acronyms are used in these specifications or on the drawings, they are to be construed the same as the respective expressions represented. Copies of the referenced specifications/ standards referred to herein may be procured by the Contractor, from the following:

ANSI American National Standards Institute

11 W 42nd St.

New York, NY 10036

ASTM American Society for Testing and Materials 100 Barr Harbor Dr.

West Conshohocken PA 19428-2959

ASTM A 116-88 Zinc-Coated (Galvanized) Steel Woven Wire Fence Fabric ASTM A 121 REV A-92 Zinc-Coated (Galvanized) Steel Barbed Wire ASTM A 123 REV A-89 Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel

Products ASTM A 153/A 153M-95 Zinc coating (Hot-Dip) on Iron and Steel Hardware

ASTM A 641-92 Zinc-Coated (Galvanized) Carbon Steel Wire ASTM A 702-89 Steel Fence Posts and Assemblies, Hot Wrought R1994)

01009-3

CFR Code of Federal Regulations (Available from the Government Printing Office) N. Capitol St. between G and H St., NW Washington, DC 20402

FS Federal Standard General Services Administration

Specifications Branch Room 6039, GSA Building 7th and D Streets, S.W.

Washington, DC 20407

GSA General Services Administration

F St. and 18th St., NW Washington, DC 20405

OSHA Occupational Safety and Health Administration

US Department of Labor 200 Constitution Ave., NW Washington DC 20210

OSHA 2207-91 Construction Industry

1.3 DEFINITIONS

A. Approvals: Approval of the submittals is an indication that the Contractor's submittals have been reviewed and that there are no objections, except as noted. Approval of deviations shall apply only to those deviations or omissions from the requirements of the drawings and specifications brought to the Government 's attention in writing. After approval of an item, submit a substitute for approval when the approved item cannot be purchased or delivered in time to avoid delay in completion of the project.

1.4 SUBMITTALS

A. Scope: Submittals include design computations, shop drawings, manufacturers' literature, as-built drawings, samples, and maintenance manuals.

B. Requirements: Refer to specifications for submittals required. Allow at least five working days for review. Submittals shall be delivered to the Government.

C. Identification of Submittals: Completely identify each submittal by showing at least the following information:

1. Name and address of submitter, plus name and telephone number of the individual to contact for further information.

2. Name of project as it appears in these specifications.

3. Contract number, drawing number, and specification section number to which the submittal applies.

4. Whether this is an original submittal or re-submittal.

01009-4

5. Each item shall clearly note the manufacturer's name and address, trade name, product, lot, style, color, catalog designation or model number, and locations of use.

1.5 DELIVERY, STORAGE, AND HANDLING:

A. Delivery: The Contractor shall protect products incorporated into the work from damage while in transit to the site.

B. Storage: The Contractor shall provide temporary storage facilities for products. Storage shall comply with the manufacturer’s instructions. The storage area shall permit access for inspection and handling.

C. Handling: The Contractor shall load and unload products in such a manner that protects them from damage.

1.6 CERTIFICATES OF CONFORMANCE

A. Requirements: The Government may permit use, prior to sampling and testing, of materials when accompanied by Certificates of Conformance. Materials used on the basis of a Certificate of Conformance may be sampled and tested. Installation of materials on the basis of Certificates of Conformance shall not relieve the Contractor of responsibility for incorporating materials which conform to the requirements of the drawings and specifications.

Material not conforming to those requirements will be subject to rejection, whether in place or not.

B. Format: The Certificate of Conformance provided by the supplier shall:

1. State that the named product conforms to the Contract requirements.

2. Either be accompanied with a certified copy of the test results or certify that such test results are on file with the manufacturer and will be furnished to the Government upon request.

3. Provide the name and address of the manufacturer, the testing agency, and the date of tests.

4. Set forth the means of identification which will permit field determination of the product delivered as being the product covered by the certification.

1.7 QUALITY ASSURANCE:

A. Codes and Standards: The work shall comply with codes and standards applicable to each type of work and as listed in the individual sections of these specifications. This Contract incorporates materials, applications, and tests by reference with the same force and effect as when they were given in full text.

B. Conflict: Where a conflict occurs between reference documents and project specifications, the project specifications shall govern.

1.8 PROJECT/SITE CONDITIONS:

A. Access to the Work: See attached map.

01009-5

1. Four wheel drive or ATV vehicles may be necessary for access to the site. Access to the work shall be by existing roads, two tracks, and marked paths.

2. Access to the work shall be provided by and at the Contractors expense. No roads shall be constructed by the Contractor or off-road driving permitted without prior written permission from the Government. Travel along the fence line is not permitted without prior written permission from the Government. The Contractor shall not travel off road when the ground is wet.

3. Contractor shall exercise care to prevent unnecessary surface disturbance to existing grass, vegetation, and to existing roads and two-tracks.

4. Public, State, or private access roads damaged by the Contractor shall be restored, at the

Contractor’s expense, to the same condition they were in at the commencement of work.

B. Environmental Considerations:

1. No blading will be allowed. Cutting and clearing shall be by hand cutting (chain saws included). Dispose of cut brush by scattering it evenly along the east side adjacent to the fence line.

1.9 SEQUENCING AND SCHEDULING:

A. Work Schedule: The schedule shall be submitted at the pre-work conference. When requested, the Contractor shall submit an updated schedule within three calendar days. As a minimum, the estimated start and completion dates shall be shown in the schedule.

PART 2: PRODUCTS

(There are no applicable requirements.)

PART 3: EXECUTION

3.1 PROJECT MEETINGS:

A. Pre-Work Conference:

1. A pre-work conference will be held prior to the start of work. The Contractor will be notified in advance of meeting time, date and place. The purpose will be to review required work, project drawings and specifications, construction schedules, payroll and payments, and administrative provisions of the Contract.

2. The Contractor, subcontractors and the persons responsible for coordination of the work shall be present at the meeting.

3. The Contractor shall be prepared to summarize and explain procedures planned for the project.

B. Progress Meetings:

1. Meetings shall be held at the project site, or as determined by the Government.

2. Meetings may be called by either the Government or the Contractor. Request shall state

01009-6 who should attend and include an agenda.

C. Final Inspection:

1. Meeting shall be held at the project site, or as determined by the Government.

2. The Contractor shall notify the Government in writing at least 3 working days before the completion date so the Government can schedule final inspection.

3. The Contractor shall require the superintendent to be present during this inspection.

3.2 PREPARATION

A. Work Limits and Control Points: Will be established by the Government.

PART 4: MEASUREMENT AND PAYMENT

4.1 METHOD OF MEASUREMENT:

A. Units: Work described in this section will not be measured for payment.

4.2 BASIS OF PAYMENT:

A. Payment: No direct payment for the work described under this section will be made. The Contractor shall include consideration for this item in the bid price for other items of the Contract.

END OF SECTION

Fence Removal 02827-7

SECTION 02827

FENCE REMOVAL

1.1 SUMMARY

A. Section Includes: Removing 22 miles of 4-wire fence and approximately 5 miles of woven wire fence, 132 end panels, 100 stress panels, and 45 corner panels, and 60 wire gates.

1.2 PROJECT/SITE CONDITIONS

A. Requirements: Access roads shall not be constructed along fence lines or to the jobsite unless written approval is granted by the Government.

2.1 MATERIALS

A. Requirements: Furnish materials required to remove fences and gates.

3.1 REMOVAL

A. Removal of Existing Fence: Remove all fences, end, stress, and corner panels, and gates as staked in the field or as designated by the Government. Dispose of debris offsite in a legal manner.

4.1 METHOD OF MEASUREMENT

A. Units: Fence removal will be paid for on a lump sum basis.

4.2 BASIS OF PAYMENT

A. Payment: No direct payment for the work described under this section will be made.

Consideration for these items shall be included in the bid price. Prices and payment will be full compensation for the work described in this section. Payment will be made under:

Pay Item Pay Unit

02827(1) Fence Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lump Sum 02827(2) End Panel Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lump Sum 02827(3) Stress Panel Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lump Sum 02827(4) Corner Panel Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lump Sum 02827(5) Gate Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lump Sum

Wire Fences and Gates 02827-8

SECTION 02824

WIRE FENCES AND GATES

1.1 SUMMARY

A. Section Includes: Construction of 28 miles of 4-wire fence, 250 stress panels, 132 end panels, 45 corner panels, and 60 gates.

1.2 SUBMITTALS

A. General: Submittals shall be according to Section 01009 - General Information and Requirements

B. Certificates of Conformance: Submit a copy of written certification from the manufacturer to the Government that the Contractor-furnished fence posts, droppers, and wire conform to the requirements of this section.

1.3 QUALITY ASSURANCE

A. General: Contractor-furnished gates and accessories will be approved by the Government before installation.

2.1 CONTRACTOR-FURNISHED MATERIALS

A. Barbed Wire: A strand of two 12-1/2-gauge galvanized wires twisted together with 2-point barbs of 14-gauge wire spaced 4-inches apart. Wire and barbs shall be zinc-coated steel, with a zinc coating of at least 0.3 oz/ft2 of coated surface area. The minimum breaking strength of each wire shall be 950 lb-force. The barbed wire shall conform to ASTM A 121.

B. Barbless Wire: A strand of two 12-1/2-gauge, galvanized wires twisted together. Wire shall be zinc-coated steel wire of at least 0.3 oz/ft2 of coated surface area. The minimum breaking strength of each wire shall be 950 lb-force. The barbless wire shall conform to ASTM A 121.

C. Staples: Shall be 9-gauge, hot-dipped, galvanized, two-inches long.

D. Nails: Shall be 60d ring shank 6-inch, 7-gauge.

E. Steel Fence Posts: ASTM A 702; green with white or silver tops "T" bar type, with a welded or riveted anchor plate. Furnish with clip-type wire fasteners, punched tabs for fastening wires are not acceptable. Steel posts shall be manufactured from wrought, rail, or new billet steel, and shall have a minimum weight of 1.33 lb/lin ft, exclusive of the anchor plate. The anchor plates shall weigh a minimum of 0.67 pounds +5 percent, and be a minimum of 18 inches2 in area.

F. Wire Fence Stays: Not used.

02827-9

G. Steel Tubular Post and Braces:

1. Acceptable Steel Tubular Posts and Braces: The diameter for brace posts shall be 2 3/8 inches by 6 feet in length. The diameter for the line post shall be 2 3/8 inches by 6 ½ feet in length. Fireproof fencing or equivalent.

2. Basis for Rejection: Posts and braces are not acceptable are bent or dented.

H. Mechanical Gate Closers: Assembly must include the following salient features:

1. A rigid steel strap or 9-gauge smooth wire loop 6 inches from the ground securely connected to the gate post and shaped so the gate stay shall be securely held in place.

2. An adjustable cable or chain, or rigid steel strap fastened to a cam lever device located 6 inches from the top of the gate post. The closer shall be capable of securely holding the gate in place.

I. Brace Wires: Four wires of 9-gauge smooth, galvanized wire or 2 wires of galvanized, 12-1/2-gauge barbless wire. The minimum weight of zinc coating for 9-gauge wire shall be at least 0.4 oz of zinc/ft2 of coated surface area; for 12-1/2-gauge wire at least 0.3 oz of zinc/ft2 of coated surface area.

J. Miscellaneous Wire: Wire for ties and gate loops shall be 12-1/2-gauge galvanized wire.

K. Clip-Type Wire Fastener: Shall be galvanized wire, 8-gauge.

L. Wire Gates: Furnish with the same type wire and wire spacing as the fence. Type of wire and spacing shall be as shown on the drawings.

M. Post Grout: Furnish a rapid setting commercial product manufactured for anchoring posts.

2.3 WOOD TREATMENT PRACTICES

A. Treated posts shall be full length treated with a water-borne preservative approved by the American Wood Preservers Bureau such as Acid Copper Chromate (ACC), Ammoniacal Copper Arsenate (ACA), Ammoniacal Copper Zinc Arsenate (ACZA), or Chromated Copper Arsenate (CCA). Pentachlorophenol and creosote are not acceptable. Treatment shall meet retention and penetration requirement of AWPA C5. Furnish certification from the wood preserver verifying that the preservation treatment meets the specified requirements. A manufacturer’s product safety data sheet on the wood preservative used shall also be furnished with the posts.

3.1 PREPARATION

A. Clearing: No blading will be allowed. Provide minimum disturbance to existing grass, vegetation, and to existing roads and two-tracks.

3.2 INSTALLATION

A. General: Steel posts shall not be used for end-panel, corner-panel, gate-panel, or stress-panel posts. Set wood posts in dug or drilled holes unless written authorization is obtained for driving

02827-10 line posts. Drive steel posts. When treated members must be bored or cut during construction, thoroughly swab untreated surfaces with copper naphthenate.

B. Ratio of Steel Line Posts to Wood Posts: 4:1

C. Setting Posts: Dig holes for setting wood posts to the depth as shown on the Work Data Sheet.

Set posts plumb and to the spacing and grades as shown on the drawings, unless staked otherwise. Space holes within 6 inches of the dimension shown on the drawings or in the Work Data Sheet. Holes shall provide adequate open space around the post so backfill can be tamped the full depth around the post. Backfill with soil around each post gradually and uniformly.

Compact backfill firmly from the bottom of the hole to the ground surface.

D. Driving Posts:

1. Wood Posts: Drive to the depth shown on the Work Data Sheet. Wood posts to be driven shall have tapered end driven into ground. Drive posts plumb. Posts that are split, bent or broomed will not be accepted.

2. Steel Posts: Drive into the ground to the depth shown on the drawings or until the anchor plate is slightly below the ground surface. Posts shall be driven plumb. When rock formations prevent driving remove anchor plate and excavate or drill holes a minimum of 18 inches deep and slightly larger than the diameter of the post. Place posts in the holes and grout the post solidly in position.

E. Corner Post, Gate Post, Corner Panel, Brace, End Panel, and Stress Panel Assemblies:

Construct as shown on the drawings or as staked in the field. Rock jacks shall not be substituted for these items. Construct stress panels on crests of hills, at points which wire is to be stretched, and a maximum of 1320 feet center-to-center. Construct end panels at the end of fence runs unless shown otherwise on the drawings. Brace rails shall be nailed to the panel posts using two nails at each end of the rail.

F. Figure Fours and Rock Jacks: May be used in rock. Figure fours shall be used in lieu of steel posts, and rock jacks in lieu of wood line posts; except where a series of figure fours are required, a rock jack shall be substituted for every fifth figure four. Figure fours and rock jacks shall be constructed as shown on the drawings.

G. Wire: Stretch tightly and staple to wood posts or securely attach to steel posts with standard wire clips. Wire is properly stretched when it is springy to the touch. Drive staples crosswise with the grain of the wood. The wire shall be free to move through the staples as it expands and contracts. Terminate wire at each end post, gate post, corner post, or stress panel. Wrap wire around the post two times and tie off by wrapping around the incoming wire a minimum of four times.

H. Brace Wire: Double-loop and twist tight with a stick. Leave one end of the stick long enough to fasten behind the horizontal brace to prevent wire from unwinding.

I. Gates: Installed according to the Work Data Sheet, the drawings, and as recommended by the manufacturer when applicable.

J. Mechanical Gate Closers: Line up the latch with the gate. Adjust latch assembly after installation so that the latch does not bind and the gate hangs properly.

02827-11

K. Spiking: For spikes larger than 40d, predrilled lead holes shall be used. The hole diameter shall be three-fourths the diameter of the spike and drilled to a depth no greater than 1/2 the length of the spike.

L. Minor Depressions or Minor Drainage Crossings: Add additional steel posts and wire when space between bottom wire and ground exceeds 20 inches for barbed wire fence. Additional steel posts shall be set at the top and bottom of breaks or the centerline of the drainage depending on the size and shape of the drainages. Additional wire shall start and end from the main fence.

4.1 METHOD OF MEASUREMENT

A. Units: The work described in this section will be on a lump sum basis.

B. No direct payment will be made for deadmen, minor depression crossings, or drainage crossings. The Contractor shall include consideration for these items in the bid price for other items of the contract.

C. Fence removal will be measured and paid for in Section 02827 – Fence Removal.

4.2 BASIS OF PAYMENT

A. Payment: No direct payment for the work described under this section will be made.

Consideration for this item shall be included in the bid price. Prices and payment will be full compensation for the work described in this section. Payment will be made under:

Pay Item Pay Unit

02824(1) Barbed Wire Fence . . . . . . . . . . . . . . . . . . . . . . . Lump Sum 02824(2) Barbed Wire End Panel . . . . . . . .. . . . . . . . . . . . Lump Sum 02824(3) Barbed Wire Stress Panel . . . . . . . . . . . . . . . . . . Lump Sum 02824(4) Three-Post Barbed Wire Corner Panel . . . . . . . . Lump Sum 02824(5) Barbed Wire Gate. . . . . . . . . . . . . . . . . . . . . . . . Lump Sum

Work Data Sheet

WORK DATASHEET

WIRE FENCES AND GATES

Fence Name: Neiber Fire Fences

Fence Location: Washakie County Wyoming

Fence Length: 28 miles

Corners: 45

End Panels: 132

Stress Panels: 250

Gates: 60

Fence type: 4- Wire

Type of wire: Top wire: Barbed Intermediate wires: Barbed Bottom wire: Smooth

Wire locations/dimensions in inches for Drawing BLM-02824-1:

Spacing between top and top middle wire (D): 12 inches

Spacing between middle wires (C): 7 inches

Spacing between bottom middle wire and bottom wire (B): 7 inches

Spacing between bottom wire and ground (A): 16 inches

Line post spacing (L): 16 ft 6 inches

Stay spacing: 8 ft 3 inches

Length of steel tubular posts (H1): 6 ft 6 inches

Depth of steel tubular posts in ground (h1): 2 ft 6 inches

Length of steel posts (H2): 5 ft 6 inches

Depth of steel posts in ground (h2): 1 ft 6 inches

Number of mechanical gate closers: 0

Section 01009
General Information and Requirements
Part 1: General
PART 2: PRODUCTS
PART 3: EXECUTION
PART 4: MEASUREMENT AND PAYMENT
Section 02827
Fence Removal
PART 1: GENERAL
PART 2: PRODUCTS
PART 3: EXECUTION
PART 4: MEASUREMENT AND PAYMENT
Section 02824
Wire Fences and Gates
PART 1: GENERAL
PART 2: PRODUCTS
PART 3: EXECUTION
PART 4: MEASUREMENT AND PAYMENT