Attach 1.2 ACM TEST RESULT CONCRETE RESULTS, CONCRETE POSTS_FENCES BE, MP, SM, SP, TH, WH, 05-16-22.pdf
PDF 2 MB Posted
- Attached to
- Beeson Fences
- Solicitation number
- FA527025Q0039
About this file
This document is an Asbestos Analysis Report prepared by SHOKAIHATSU CO., LTD. for NIHON MECCS CO., LTD., detailing asbestos sampling conducted on fence concrete posts at various locations on Kadena Air Base in Okinawa, Japan on April 20, 2022. The inspection involved collecting material samples from six different sites: Marek Park, Washington Heights, Beeson, Terrace Heights, Sebille Manor, and Stillwell Park, with each location having a concrete fence post sampled and analyzed.
The laboratory analysis was performed by INALAB JAPAN, INC., an NVLAP-accredited facility, using EPA Method 600/R-93/116 for asbestos determination in bulk building materials. Using polarized light microscopy (PLM), the lab examined the gray cementitious material from each sample location. The conclusive results showed no asbestos detected in any of the samples, with all materials containing less than 0.1% asbestos according to Japan Environmental Governing Standards (JEGS). The report includes photographic documentation, analytical summaries, and laboratory accreditation certificates to validate the testing process and findings.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS ANALYSIS REPORT
Conducted at:
ACM SAMPLING FOR REPAIR FENCES,
VARIOUS LOCATIONS, OKINAWA, JAPAN
Prepared for:
NIHON MECCS CO., LTD.
Prepared by:
SHOKAIHATSU CO., LTD.
May 2022
TABLE OF CONTENTS
1.0 INTRODUCTION
2.0 ASBESTOS
APPENDICES
APPENDIX A: Analytical Summary, Photographic Documentation, and Laboratory Analytical
Reports
APPENDIX B: Building Inspector Certification
APPENDIX C: Laboratory Accreditations
1.0 INTRODUCTION
SHOKAIHATSU CO., LTD. was retained by NIHON MECCS CO., LTD. to collect material samples for presence of asbestos. The purpose of these inspections was to identify suspected
Asbestos Containing Building Materials (ACBM�s) components which may be impacted by disposal.
The general scope of work for this project is to sample and test components for fence repair work at various locations on Kadena Air Base.
On 20 April 2022, SHOKAIHATSU CO., LTD.�s certified Asbestos Building Inspector, Mr.
Tomonori Nomura completed the site inspection and upon completion, material samples were collected from the suspected ACBM�s.
2.0 ASBESTOS
SAMPLING METHODOLOGY � ASBESTOS
The method described in 40 CFR Part 763.86, Sampling (for asbestos) for collecting bulk asbestos samples protocol were used.
ASBESTOS ANALYSIS
Suspected ACM of the bulk samples collected were analyzed by INALAB JAPAN, INC., who are accredited for bulk sampling analysis through successful participation in the National
Voluntary Laboratory Accreditation Program (NVLAP).
The method of analysis was based on Bulk Asbestos Analysis (PLM) EPA 600/R-93/116:
Method for the Determination of Asbestos in Bulk Building Materials and the provisions of the
Japan Environmental Governing Standards (JEGS). Identification was made using polarized light microscopy (PLM). For �non-detect� or �ND� PLM results, the material was considered less than 0.1% asbestos. For �trace�, or �less than one (1) percent�, PLM results was further analyzed by appropriate quantification methods using the PLM 1000 point count method.
An analytical summary, photographic documentation, and laboratory analytical report detecting
Asbestos Containing Material (ACM) can be found in Appendix A.
3.0 CONCLUSION
No ACM was detected.
APPENDIX A:
Analytical Summary, Photographic Documentation, and Laboratory
Analytical Reports
Asbestos Analytical Summary
ACM Sampling for Repair Fences, Various Locations, Okinawa, Japan
Sample ID No.
LAB ID No. Material Description Layer(s) Asbestos Content
A-1 20220428035 Fence Concrete Post, MP-03 (7 feet), B10230, Marek Park
Gray Cementitious Material None Detected
A-2 20220428036 Fence Concrete Post, WH-05 (4 feet), B8201, Washington Heights
Gray Cementitious Material None Detected
A-3 20220428037 Fence Concrete Post, BA-01 (4 feet), B9463, Beeson
Gray Cementitious Material None Detected
A-4 20220428038 Fence Concrete Post, TH-07 (4 feet), B2961, Terrace Heights
Gray Cementitious Material None Detected
A-5 20220428039 Fence Concrete Post, C-01~C-02 (7 feet), B5540, Sebille Manor
Gray Cementitious Material None Detected
A-6 20220428040 Fence Concrete Post, B-01~B-02 (6 feet), B1919, Stillwell Park
Gray Cementitious Material None Detected
None Detected (less than 0.1% based on the provisions of JEGS)
ASBESTOS PHOTOGRAPHIC DOCUMENTATION
20-Apr-2022SAMPLE DATE
SAMPLE ID NO.
Marek Park, Kadena Air Base
TYPE OF MATERIAL
Fence Concrete Post (7 feet)
A-1
FACILITY NO.
Bldg. 10230
(MP-03)
ASBESTOS (%) None Detected
LOCATION
SAMPLE ID NO. A-2
FACILITY NO.
Bldg. 8201
(WH-05)
TYPE OF MATERIAL
Fence Concrete Post (4 feet)
Washington Heights, Kadena Air Base
ASBESTOS (%) None Detected
LOCATION
SAMPLE DATE 20-Apr-2022
None Detected
SAMPLE DATE 20-Apr-2022
ASBESTOS (%)
Bldg. 9463
(BA-01)
Beeson, Kadena Air Base
A-3
FACILITY NO.
LOCATION
TYPE OF MATERIAL
Fence Concrete Post (4 feet)
SAMPLE ID NO.
Terrace Heights, Kadena Air Base
SAMPLE DATE 20-Apr-2022
SAMPLE ID NO. A-4
FACILITY NO.
Bldg. 2961
(TH-07)
LOCATION
TYPE OF MATERIAL
Fence Concrete Post (4 feet)
ASBESTOS (%) None Detected
Sebille Manor, Kadena Air Base
SAMPLE DATE 20-Apr-2022
SAMPLE ID NO. A-5
FACILITY NO.
Bldg. 5540 (C-01~C-02)
ASBESTOS (%) None Detected
LOCATION
TYPE OF MATERIAL
Fence Concrete Post (7 feet)
SAMPLE DATE 20-Apr-2022
SAMPLE ID NO. A-6
FACILITY NO.
Bldg. 1919 (B-01~B-02)
ASBESTOS (%) None Detected
LOCATION
TYPE OF MATERIAL
Fence Concrete Post (6 feet)
Stillwell Park, Kadena Air Base
APPENDIX B:
Building Inspector Certification
APPENDIX C:
Laboratory Accreditations
U n it ed
S ta te s
D e p ar tm e n t o f
C o m m e rc e
N at io n al In s ti tu te o f
S ta n d ar d s a n d
T e ch n o lo g y
C e rt if ic a te o f A c cr e d it at io n t o
I S
O
/IE
C
:2
N V
L A
P L
A B
C O
D E
-0
In al ab
J ap an , I n c.
K an ag aw a
Ja pa n is a cc re d ite d b y th e N a tio na l V ol u nt a ry L ab o ra to ry A cc re d ita tio n
P ro g ra m f or s pe ci fic s er vi ce s, lis te d o n th e
S co pe o f A cc re d ita tio n fo r:
A sb es to s F ib er
A n al ys is
T h is la b or a to ry is a cc re d ite d in a cc o rd an ce w ith t h e re co g ni ze d
I nt e rn a tio n a l S ta nd a rd I
S O
/I E
C
5:
T hi s ac cr e d ita tio n d e m o n st ra te s te ch n ic a l c om pe te nc e fo r a d e fin ed s co pe a n d t h e o p e ra tio n o f a la b or a to ry q ua lit y m an a ge m e n t sy st em re fe r to jo in t
IS
O -I
LA
C
-I A
F C o m m un iq u e d a te d J a n ua ry
-0 7-th ro ug h
-0
6-
E ffe ct iv e D a te s
F o r th e
N a tio na l V o lu nt a ry
L a b or a to ry A cc re di ta tio n
P ro gr am
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
For the National Voluntary Laboratory Accreditation Program
Effective
National Voluntary Laboratory Accreditation Program
2021-10-01 through 2022-06-30
Inalab Japan, Inc.
2F 4-18 Kaigandori
Naka-Ku, Yokohama Kanagawa 231-0002
Japan Mr. Stephen Clarke
Phone: 81-045-680-2150 Email: sclarke@inalabjapan.co.jp http://www.inalabjapan.co.jp
ASBESTOS FIBER ANALYSIS NVLAP LAB CODE 200830-0
Bulk Asbestos Analysis
Code Description 18/A01 EPA -- 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of
Asbestos in Bulk Insulation Samples
18/A03 EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials
File details come from the government source that posted it. Updated .