Attach 01 1 Figures- room layouts.pdf

PDF 265 KB Posted

Attached to
Office and HVAC Renovation Main Bldg Somerville Pecan Station
Solicitation number
12805B21Q0426
Issued by

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

• Install new center wall. New wall will extend a minimum of 6” above existing ceiling height.

• Re-work ceiling grid for new wall. Adjust room ceiling grid for 2 x 2 ceiling tiles.

• Install ceiling tiles in each room. Existing 2 x 4 ceiling tiles can be cut to 2 x 2 if not damaged or stained. Provide additional ceiling tiles, as necessary.

• Insulation of ceiling tile to be re-used and spread evenly above the ceiling. Provide new ceiling tile as necessary to ensure complete coverage.

• Install new entry metal frame and door.

• Install new electrical receptacle in new wall using existing circuits in the room.

• Replace lights in each room. Provide separate switches for each room.

• Provide supply and return A/C grills and ductwork for each office.

Figure 1: Office 1 lights supply return

New electrical outlet

Data box

Existing electrical outlet

Attachment 1: Figures- room layouts

• Install ceiling tiles in each room. Existing 2 x 4 ceiling tiles can be cut to 2 x 2 if not damaged or stained. Provide additional ceiling tiles as necessary.

• Insulation of ceiling tile to be re-used and spread evenly above the ceiling. Provide new ceiling tile as necessary to ensure complete coverage.

• Install new entry metal frame and door.

• Install new electrical receptacle in new wall using existing circuits in the room.

• Replace lights in each room. Provide separate switches for each room. Eliminate 3-way switch.

• Eliminate door and frame that leads into the library. Patch wall on both sides to match existing.

(removed door may used for one of the new doors.).

Figure 2: Office 2

Lights supply

Return

New electrical outlet

Data box

• Install ceiling tiles in each room. Existing 2 x 4 ceiling tiles can be cut to 2 x 2 if not damaged or stained. Provide additional ceiling tiles, as necessary.

• Insulation of ceiling tile to be re-used and spread evenly above the ceiling. Provide new ceiling tile as necessary to ensure complete coverage.

• Install new entry metal frame and door.

• Install new electrical receptacle in new wall using existing circuits in the room.

• Replace lights in each room. Provide separate switches for each room.

• Provide supply and return A/C grills and ductwork for each office.

Figure 3: Office 3

Lights

Return

Supply

New electrical outlet

Data box

• Remove frame and door leading to office 2. Patch wall to match existing.

• Provide floor cabinet with counter and stainless sink and faucet.

• Connect hot and cold water to faucet.

• Route drain to drain line for sink in restroom.

• Re-work ceiling grid for new wall. Adjust room ceiling grid for 2 x 2 ceiling tiles.

• Install ceiling tiles in each room. Existing 2 x 4 ceiling tiles can be cut to 2 x 2 if not damaged or stained. Provide additional ceiling tiles, as necessary.

• Insulation of ceiling tile to be re-used and spread evenly above the ceiling. Provide new ceiling tile as necessary to ensure complete coverage.

• Replace lights in each room. Provide separate switches for each room.

• Provide supply and return A/C grills and ductwork for each office.

Figure 4: Library

Return

Supply

Light New electrical outlet

Figure 5: New Wall Detail

5/8” gypsum board on 3-5/8” metal studs

@ 16” on center Sound attenuation

Insulation

Ceiling tile

File details come from the government source that posted it. Updated .