Att J-1 Schedule of FIRM FIXED PRICE RATES.xlsx

XLSX spreadsheet 77 KB Posted

Attached to
Critical Power Systems Federal contract opportunity
Solicitation number
N39430-20-R-2230
Issued by
Department of the Navy Naval Facilities Engineering Command

About this file

This document contains a schedule of firm fixed price rates for a critical power systems indefinite-delivery/indefinite-quantity contract opportunity issued by the Department of the Navy Naval Facilities Engineering Command. The schedule provides fully burdened hourly rates for ten labor categories per ordering year over an eight year period, including a six-month option. It also contains equipment lists with historical pricing data for generators, switchgear, switchboards, uninterruptible power supplies, battery systems, motor control centers, air conditioners, and automatic transfer switches to be provided on the contract on a firm fixed price basis.

View the file

Other files for this federal contract opportunity

Other files attached to Critical Power Systems, newest first.
File Type Posted
N39430-20-R-2230 - Amendment 0003.pdf PDF
N39430-20-R-2230 - Amendment 0002.pdf PDF
REVISED Att J-1 Schedule of FIRM FIXED PRICE RATES.xlsx XLSX spreadsheet
N39430-20-R-2230-Amendment 0001.pdf PDF
Att J-3 Financial Inst Bank Information.docx DOCX document
Att J-4 DD 254 DoD Contract Security Classification Specification.pdf PDF
N39430-20-R-2230 SOLICITATION.pdf PDF
Att J-2 NAVFAC Past Performance Questionnaire (Form PPQ).doc DOC document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUMMARY TOTAL FFP

Attachment J-1
Page 1 of 10
Date: Month Year
Submitted By:
Company Name
Address
City, State Zip Code
Ordering Year 1Ordering Year 2Ordering Year 3Ordering Year 4Ordering Year 5Ordering Year 6Ordering Year 7Ordering Year 8
TotalTotalTotalTotalTotalTotalTotalTotal6-MonthTotal FFP
Labor CategoryAmountAmountAmountAmountAmountAmountAmountAmountOptionIDIQ Amount
Project Manager$$$$$$$$$$ -
Subcontractor Administration$$$$$$$$$$ -
Project Controller/Scheduler$$$$$$$$$$ -
Quality Assurance Management$$$$$$$$$$ -
Safety Office Management$$$$$$$$$$ -
Electrical Engineer$$$$$$$$$$ -
Mechanical Engineer$$$$$$$$$$ -
Project Engineer$$$$$$$$$$ -
Admin Assistance$$$$$$$$$$ -
CADD Operator$$$$$$$$$$ -
Site Superintendent$$$$$$$$$$ -
Total Direct Labor$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0

CLIN Total Firm Fixed Price $ - 0 $ - 0 $ - 0 $ - 0 $ - 0 $ - 0 $ - 0 $ - 0 $ - 0 $ - 0

Notes: SOURCE SELECTION SENSITIVE

Solicitation No.: N39430-20-R-2230 Navy Program Name: Critical Power

IDIQ

PRICING SCHEDULE OF

TOTAL FIRM FIXED PRICE

BY YEAR AND GRAND TOTAL

ORDERING YEAR 1

Attachment J-1
Page 3 of 10
Company Name
City, State Zip Code
Fully Price
Labor CategoriesHoursHourly Rate*Amount
Project Manager2,560$0.00$0.00
Subcontractor Administration640$0.00$0.00
Project Controller/Scheduler640$0.00$0.00
Quality Assurance Management2,240$0.00$0.00
Safety Office Management2,240$0.00$0.00
Electrical Engineer1,280$0.00$0.00
Mechanical Engineer1,280$0.00$0.00
Project Engineer2,560$0.00$0.00
Admin Assistance640$0.00$0.00
CADD Operator1,280$0.00$0.00
Site Superintendent2,560$0.00$0.00
Subtotal Direct Labor17,920$ - 0

CLIN Total Firm Fixed Price ERROR:#REF!

Notes:SOURCE SELECTION SENSITIVE
*Provide FULLY PRICED rates that includes hourly rate of pay, all applicable burdens (e.g., fringe benefit, overhead, G&A expenses), and profit.

ORDERING YEAR 1

IDIQ Pricing Schedule of Firm Fixed Price

ORDERING YEAR 2

Attachment J-1
Page 3 of 10
Company Name
City, State Zip Code
Fully Price
Labor CategoriesHoursHourly Rate*Amount
Project Manager2,560$0.00$0.00
Subcontractor Administration640$0.00$0.00
Project Controller/Scheduler640$0.00$0.00
Quality Assurance Management2,240$0.00$0.00
Safety Office Management2,240$0.00$0.00
Electrical Engineer1,280$0.00$0.00
Mechanical Engineer1,280$0.00$0.00
Project Engineer2,560$0.00$0.00
Admin Assistance640$0.00$0.00
CADD Operator1,280$0.00$0.00
Site Superintendent2,560$0.00$0.00
Subtotal Direct Labor17,920$ - 0

CLIN Total Firm Fixed Price ERROR:#REF!

Notes:SOURCE SELECTION SENSITIVE
*Provide FULLY PRICED rates that includes hourly rate of pay, all applicable burdens (e.g., fringe benefit, overhead, G&A expenses), and profit.

ORDERING YEAR 2

IDIQ Pricing Schedule of Firm Fixed Price

ORDERING YEAR 3

Attachment J-1
Page 3 of 10
Company Name
City, State Zip Code
Fully Price
Labor CategoriesHoursHourly Rate*Amount
Project Manager2,560$0.00$0.00
Subcontractor Administration640$0.00$0.00
Project Controller/Scheduler640$0.00$0.00
Quality Assurance Management2,240$0.00$0.00
Safety Office Management2,240$0.00$0.00
Electrical Engineer1,280$0.00$0.00
Mechanical Engineer1,280$0.00$0.00
Project Engineer2,560$0.00$0.00
Admin Assistance640$0.00$0.00
CADD Operator1,280$0.00$0.00
Site Superintendent2,560$0.00$0.00
Subtotal Direct Labor17,920$ - 0

CLIN Total Firm Fixed Price ERROR:#REF!

Notes:SOURCE SELECTION SENSITIVE
*Provide FULLY PRICED rates that includes hourly rate of pay, all applicable burdens (e.g., fringe benefit, overhead, G&A expenses), and profit.

ORDERING YEAR 3

IDIQ Pricing Schedule of Firm Fixed Price

ORDERING YEAR 4

Attachment J-1
Page 3 of 10
Company Name
City, State Zip Code
Fully Price
Labor CategoriesHoursHourly Rate*Amount
Project Manager2,560$0.00$0.00
Subcontractor Administration640$0.00$0.00
Project Controller/Scheduler640$0.00$0.00
Quality Assurance Management2,240$0.00$0.00
Safety Office Management2,240$0.00$0.00
Electrical Engineer1,280$0.00$0.00
Mechanical Engineer1,280$0.00$0.00
Project Engineer2,560$0.00$0.00
Admin Assistance640$0.00$0.00
CADD Operator1,280$0.00$0.00
Site Superintendent2,560$0.00$0.00
Subtotal Direct Labor17,920$ - 0

CLIN Total Firm Fixed Price ERROR:#REF!

Notes:SOURCE SELECTION SENSITIVE
*Provide FULLY PRICED rates that includes hourly rate of pay, all applicable burdens (e.g., fringe benefit, overhead, G&A expenses), and profit.

ORDERING YEAR 4

IDIQ Pricing Schedule of Firm Fixed Price

ORDERING YEAR 5

Attachment J-1
Page 3 of 10
Company Name
City, State Zip Code
Fully Price
Labor CategoriesHoursHourly Rate*Amount
Project Manager2,560$0.00$0.00
Subcontractor Administration640$0.00$0.00
Project Controller/Scheduler640$0.00$0.00
Quality Assurance Management2,240$0.00$0.00
Safety Office Management2,240$0.00$0.00
Electrical Engineer1,280$0.00$0.00
Mechanical Engineer1,280$0.00$0.00
Project Engineer2,560$0.00$0.00
Admin Assistance640$0.00$0.00
CADD Operator1,280$0.00$0.00
Site Superintendent2,560$0.00$0.00
Subtotal Direct Labor17,920$ - 0

CLIN Total Firm Fixed Price ERROR:#REF!

Notes:SOURCE SELECTION SENSITIVE
*Provide FULLY PRICED rates that includes hourly rate of pay, all applicable burdens (e.g., fringe benefit, overhead, G&A expenses), and profit.

ORDERING YEAR 5

IDIQ Pricing Schedule of Firm Fixed Price

ORDERING YEAR 6

Attachment J-1
Page 3 of 10
Company Name
City, State Zip Code
Fully Price
Labor CategoriesHoursHourly Rate*Amount
Project Manager2,560$0.00$0.00
Subcontractor Administration640$0.00$0.00
Project Controller/Scheduler640$0.00$0.00
Quality Assurance Management2,240$0.00$0.00
Safety Office Management2,240$0.00$0.00
Electrical Engineer1,280$0.00$0.00
Mechanical Engineer1,280$0.00$0.00
Project Engineer2,560$0.00$0.00
Admin Assistance640$0.00$0.00
CADD Operator1,280$0.00$0.00
Site Superintendent2,560$0.00$0.00
Subtotal Direct Labor17,920$ - 0

CLIN Total Firm Fixed Price ERROR:#REF!

Notes:SOURCE SELECTION SENSITIVE
*Provide FULLY PRICED rates that includes hourly rate of pay, all applicable burdens (e.g., fringe benefit, overhead, G&A expenses), and profit.

ORDERING YEAR 6

IDIQ Pricing Schedule of Firm Fixed Price

ORDERING YEAR 7

Attachment J-1
Page 3 of 10
Company Name
City, State Zip Code
Fully Price
Labor CategoriesHoursHourly Rate*Amount
Project Manager2,560$0.00$0.00
Subcontractor Administration640$0.00$0.00
Project Controller/Scheduler640$0.00$0.00
Quality Assurance Management2,240$0.00$0.00
Safety Office Management2,240$0.00$0.00
Electrical Engineer1,280$0.00$0.00
Mechanical Engineer1,280$0.00$0.00
Project Engineer2,560$0.00$0.00
Admin Assistance640$0.00$0.00
CADD Operator1,280$0.00$0.00
Site Superintendent2,560$0.00$0.00
Subtotal Direct Labor17,920$ - 0

CLIN Total Firm Fixed Price ERROR:#REF!

Notes:SOURCE SELECTION SENSITIVE
*Provide FULLY PRICED rates that includes hourly rate of pay, all applicable burdens (e.g., fringe benefit, overhead, G&A expenses), and profit.

ORDERING YEAR 7

IDIQ Pricing Schedule of Firm Fixed Price

ORDERING YEAR 8

Attachment J-1
Page 3 of 10
Company Name
City, State Zip Code
Fully Price
Labor CategoriesHoursHourly Rate*Amount
Project Manager2,560$0.00$0.00
Subcontractor Administration640$0.00$0.00
Project Controller/Scheduler640$0.00$0.00
Quality Assurance Management2,240$0.00$0.00
Safety Office Management2,240$0.00$0.00
Electrical Engineer1,280$0.00$0.00
Mechanical Engineer1,280$0.00$0.00
Project Engineer2,560$0.00$0.00
Admin Assistance640$0.00$0.00
CADD Operator1,280$0.00$0.00
Site Superintendent2,560$0.00$0.00
Subtotal Direct Labor17,920$ - 0

CLIN Total Firm Fixed Price ERROR:#REF!

Notes:SOURCE SELECTION SENSITIVE
*Provide FULLY PRICED rates that includes hourly rate of pay, all applicable burdens (e.g., fringe benefit, overhead, G&A expenses), and profit.

ORDERING YEAR 8

IDIQ Pricing Schedule of Firm Fixed Price

6-Month Option

Attachment J-1
Page 3 of 10
Company Name
City, State Zip Code
Fully Price
Labor CategoriesHoursHourly Rate*Amount
Project Manager1,280$0.00$0.00
Subcontractor Administration320$0.00$0.00
Project Controller/Scheduler320$0.00$0.00
Quality Assurance Management1,120$0.00$0.00
Safety Office Management1,120$0.00$0.00
Electrical Engineer640$0.00$0.00
Mechanical Engineer640$0.00$0.00
Project Engineer1,280$0.00$0.00
Admin Assistance320$0.00$0.00
CADD Operator640$0.00$0.00
Site Superintendent1,280$0.00$0.00
Subtotal Direct Labor8,960$ - 0

CLIN Total Firm Fixed Price ERROR:#REF!

Notes:SOURCE SELECTION SENSITIVE
*Provide FULLY PRICED rates that includes hourly rate of pay, all applicable burdens (e.g., fringe benefit, overhead, G&A expenses), and profit.

6-Month Option IDIQ Pricing Schedule of Firm Fixed Price

EQUIPMENT LIST

EQUIPMENT COST HISTORICAL DATA

EQUIPMENT RATING RANGE Discount/Unit Price/Unit BASE OPTION 1 OPTION 2 OPTINON3 OPTION 4 TOTAL EQUIPMENT MFGR

GENERATOR-Emergency standby rated, 4 cycle, 1800 RPM, emissions rated for HP, industrial diesel engine, skid mounted, integral mounted radiator system, 24 volt starting system, a 35 amp battery charging alternator, battery charger, digital governor regulation at ±.5%, digital voltage regulation at ±.5%, digital isochronous paralleling, critical grade silencer, minimum 100 gallon individual genset day tanks, low sulfur diesel fuel compatible, coolant heaters, turbocharged, and engine to skid vibration isolators.60KW TO 5 MWCummins/Onan, Caterpillar, EMD, MTU, Detroit Diesel
600 kW3333315Cummins/Onan, Caterpillar, EMD, MTU, Detroit Diesel
750 kW2222210Cummins/Onan, Caterpillar, EMD, MTU, Detroit Diesel
1500 kW111115Cummins/Onan, Caterpillar, EMD, MTU, Detroit Diesel
2000 kW111115Cummins/Onan, Caterpillar, EMD, MTU, Detroit Diesel
TOTAL35
SWITCHGEAR-Shall be outdoor rated, dead front type, 600 volts maximum AC service, copper, metal-enclosed switchgear. The switchgear circuit breakers shall include secondary trip units (LSIG) with overload, instantaneous, and ground fault sensing. The switchgear shall bear a UL 891 label. Certified copies of production test reports shall be supplied demonstrating compliance with these standards (if applicable). The switchgear shall be delivered as a single piece enclosed in a NEMA 3R enclosure and capable of being lifted directly on a concrete pad. The switchgear shall be rated to withstand mechanical forces exerted during short-circuit conditions when connected directly to a power source having available fault current 65,000 amperes symmetrical at rated voltage. The copper bus system shall have a minimum short-circuit withstand rating of 65,000 amperes symmetrical. All circuit breakers shall have a minimum symmetrical interrupting capacity of 65,000 amperes. To ensure a fully selective system, all circuit breakers shall have 30 cycle short-time withstand ratings equal to their symmetrical interrupting ratings. All ratings shall be tested to the requirements of ANSI C37.20.1, C37.50 and C37.51 and UL witnessed and approved600A to 5000 AmpCutler Hammer, GE, Square D, Siemens
600A, 2 CB111115Cutler Hammer, GE, Square D, Siemens
800A, 2 CB111115Cutler Hammer, GE, Square D, Siemens
1200A, 4 CB2222210Cutler Hammer, GE, Square D, Siemens
1600A, 4 CB111115Cutler Hammer, GE, Square D, Siemens
2000A, 6 CB2222210Cutler Hammer, GE, Square D, Siemens
2500A, 6 CB2222210Cutler Hammer, GE, Square D, Siemens
TOTAL45
SWITCHBOARD-Shall be outdoor rated, dead front type, 600 volts maximum AC service, copper, metal-enclosed switchgear. The switchgear circuit breakers shall include secondary trip units (LSIG) with overload, instantaneous, and ground fault sensing. The switchgear shall bear a UL 891 label. Certified copies of production test reports shall be supplied demonstrating compliance with these standards (if applicable). The switchgear shall be delivered as a single piece enclosed in a NEMA 1 enclosure and capable of being lifted directly on a concrete pad. The switchgear shall be rated to withstand mechanical forces exerted during short-circuit conditions when connected directly to a power source having available fault current 65,000 amperes symmetrical at rated voltage. The copper bus system shall have a minimum short-circuit withstand rating of 65,000 amperes symmetrical. All circuit breakers shall have a minimum symmetrical interrupting capacity of 65,000 amperes. To ensure a fully selective system, all circuit breakers shall have 30 cycle short-time withstand ratings equal to their symmetrical interrupting ratings. All ratings shall be tested to the requirements of ANSI C37.20.1, C37.50 and C37.51 and UL witnessed and approved200A to 2500ACutler Hammer, GE, Square D, Siemens
800A111115Cutler Hammer, GE, Square D, Siemens
1200A5555525Cutler Hammer, GE, Square D, Siemens
1600A5555525Cutler Hammer, GE, Square D, Siemens
2000A2222210Cutler Hammer, GE, Square D, Siemens
2500A111115Cutler Hammer, GE, Square D, Siemens
TOTAL70
UPS system shall be rated at 480/277Y, three phase, 60 hertz, NFPA 111 level 1, type O, class 0.25 compliant, separate rectifier and bypass inputs. The maintenance bypass system shall include a switchboard with circuit breaker interlocks to prevent inadvertent connection of normal and bypass power sources, and shall permit closed transition transfer only while the UPS system is in static bypass. The maintenance bypass system shall be dead front type switchboard, 480 volts AC, copper bus, 3 pole, 4 wires, 60 hertz, with a full sized neutral bus200 kVA to 1100 kVAEaton Powerware, Liebet, APC, Sqaure D
650 kVA2222210Eaton Powerware, Liebet, APC, Sqaure D
750 kVA3333315Eaton Powerware, Liebet, APC, Sqaure D
825 kVA111115Eaton Powerware, Liebet, APC, Sqaure D
1000 kVA2222210Eaton Powerware, Liebet, APC, Sqaure D
1100 kVA2222210Eaton Powerware, Liebet, APC, Sqaure D
TOTAL50
BATTERY SYSTEM-Provide new absorbent glass mat (AGM) valve regulated lead-acid (VRLA) batteries for UPS units. Batteries provided shall be in accordance with the UPS manufacturer recommendations. Batteries shall be sized to provide minimum 15 minutes run time at 100% capacity
500 kVA 15 mins2222210Excide, Intersate, Powerware, Libert, APC, Custom
750 kVA 15 mins2222210Excide, Intersate, Powerware, Libert, APC, Custom
1100 kVA 15 minsTOTAL20
BATTERY MONITORING-Montoring syStem compelte with cables, HMI, software, annuncation, CTs, etc. Montors cell voltage, impedance, curet, and provides realt tiem data with alarming.2222210Cell Watch is the most widely used by industry, others are custom made
TOTAL10
ATS switches shall be arted at 600 VAC, 60 hertz, NEMA 1 and be electrically operated and mechanically held with double throw design, and operated by a momentarily energized solenoid-driven mechanism. Main operators which include overcurrent disconnect devices, linear motors or gears shall not be acceptable. Delayed Transition-type ATS shall include mechanical interlocks to ensure only two possible positions: connected-to-normal or connected-to-emergency. ATS shall be mechanically held and unaffected by momentary outages. Switch shall derive power to transfer from the source into which it will connect the load. The contact structure shall consist of main current carrying contacts and arcing contacts. The main contacts shall be of silver composition or equal. Separate arcing contacts shall be provided to protect the main contacts from excessive wear during transfers. The arcing contacts shall also be of silver composition or equal on all sizes rated 600A and above. The switch shall be positively locked and unaffected by momentary outages, so that contact pressure is maintained at a constant value and contact temperature rise is minimized for maximum reliability and operating life. Power interconnections shall be silver-plated copper bus bar. Separate bypass and isolation handles shall be utilized to provide clear distinction between the functions. Handles shall be permanently affixed and operable without opening the enclosure door. Bypass to the load-carrying source shall be accomplished with no interruption of power to the load (make before break contacts). Designs which disconnect the load when bypassing are not acceptable. The bypass handle shall have three operating modes: "Bypass to Normal," "Automatic," and "Bypass to Emergency." In the "Automatic" mode, the bypass contacts shall be out of the power circuit so that they will not be subjected to fault currents to which the system may be subjected. The isolation handle shall provide three operating modes: "Closed", "Test", and "Open." The "Test" mode shall permit testing of the entire emergency power system, including the automatic transfer switches with no interruption of power to the load. The "Open" mode shall completely isolate the automatic transfer switch from all source and load power conductors. When in the "Open" mode, it shall be possible to completely withdraw the automatic transfer switch for inspection or maintenance to conform to code requirements without removal of power conductors or the use of any tools. The ATSs shall be supplied with a fully rated neutral pole. The neutral pole shall have the same withstand and closing and operational ratings as the phase poles, and shall be arranged for break-first and make-last to minimize neutral switching transients. A microprocessor controller shall be part of the ATS. For ease of maintenance and future upgrades, the controller shall be of a modular design, with standard power supply, CPU, and I/O modules across all ampere ranges of product. Modules shall be constructed for quick removal and replacement into a rugged backplane assembly. Controller shall be capable of both serial and Ethernet communications. For highest reliability, the ATS shall contain Source Sensing Modules capable of being calibrated for direct 3-phase sensing of each source from 110 VAC to 690 VAC without the need for additional step-down transformers. In addition, the ATS shall be capable of sensing and using power from either source. Voltage sensing shall be true RMS type and shall be accurate to 1% of nominal voltage. Frequency sensing shall be accurate to 0.05Hz. The controller shall be capable of operating over a temperature range of -20 to +50 degrees C and storage from -40 to +90 degrees C.400 TO 2500 ACutler Hammer, GE, Square D, Asco
800A2222210
1200A111115
1600A122117
2000A111115
2500A111115
TOTAL32
Computer room air conditioners (CRAC’s) Temperature; humidification, dehumidification and electric re-heat capability included. New indoor units shall be front return air systems with a plenum discharge box with grills on three sides. The new CRAC units shall be able to operate and provide cooling with outside ambient temperature of minimum 125 degree Fahrenheit (52 Celsius) plus localized solar heating. The new CRACs shall be rated at 60 hertz, 480 VAC, and be sized accordingly.5 TO 50 TONLiebert, Trane, Carreir, Stulz, Eaton Powerware
5 TON2222210
20 TON212128
40 TON111115
TOTAL23
MOTOR CONTROL CENTER (MCC)-600 volt, 3 phase, 4 wire, main circuit breaker, and provisions/space for two 3 pole future circuit breakers. Panel board bussing shall be copper in a NEMA 1 enclosure. All circuit breakers shall be thermal magnetic and adjustable. Short circuit rating shall be a minimum of 50 kAIC. MCC shall comply with provisions of the latest NEMA and NFPA codes. All motor starter compartments shall be capable of operation locally and remotely via a SCADA or other remote operators. The MCC shall have 3 phase, RMS metering to include voltage, current, kilowatt, power factor, kilowatt-hour, and basic power quality. The use of potential transformers is not desired. The MCC shall have provisions for locking and tagging out all circuit interrupters. Provisions shall be provided for locking all disconnects in the OFF position with up to three padlocks. The MCC shall have adjustable trip settings on all circuit interrupters (e.g. thermal and/or magnetic circuit breakers). A lever handle operator must be provided on each disconnect. All circuit breaker operators shall include a separate TRIPPED position to clearly indicate a circuit breaker trip condition. It shall be possible to reset a tripped circuit breaker without opening the unit door. A mechanical interlock shall prevent the operator from opening the unit door while the disconnect id in the ON position. Another interlock shall prevent the operator from closing the disconnecting device while the door is open MCC shall have space heaters which are thermostatically controlled. MCC shall include a 10 kVA, 480/120-208Y general purpose lighting transformer and include a 100A, 120/208Y lighting panel board. The MCC shall be made of steel material and comply with UL 485 and CSA requirements. Paint color shall be light gray per ANSI standard Z55.10967 on all exterior surfaces. All bussing and connectors shall be tin-plated copper. The main horizontal bus shall be rated at 400 Amp continuous and shall run the full length of the MCC. Bus rating shall be rated on 65 degree C maximum temperature rise in a 40 degree C ambient. A tin plated copper ground bus shall be provided that runs the entire length of the MCC and braced be rated at 42 kA symmetrical RMS or greater18.Cutler Hammer, GE, Square D
400A2222210
600A2222210
800A111115
1200A111115
TOTAL30

File details come from the government source that posted it. Updated .