Att H - Fermilab Safety Code Requirements.pdf
PDF 57 KB Posted
- Attached to
- RFP - PAB Liquid Argon Dewar Lease and Filling
- Solicitation number
- 375404-BH
About this file
This is a Fermilab Safety Code Requirements verification form for leased cryogenic Dewars owned and filled by vendors. The form requires vendors to certify compliance with five minimum safety code requirements and must be signed by a qualified employee.
The five required safety code compliance areas are: (1) Inner Pressure Vessel must meet ASME Boiler and Pressure Vessel Code (BPVC) Section VIII; (2) Relief Devices (both pressure and vacuum) must be sized and rated per ASME BPVC Section VIII or CGA S-1.3; (3) Dewar Piping must comply with ASME B31.3; (4) Filling and Installation must adhere to CGA S-1.3, API 521, or other applicable codes, with the vendor responsible for safe installation; and (5) All applicable code-required examinations and tests must be performed. Each section allows for alternative codes to be listed if different from the specified standards. The form requires three signatures: vendor name, qualified employee printed name, qualified employee signature, and completion date.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fermilab Safety Code Requirements
Please fill out the following form verifying the minimum safety codes required by Fermilab have been met concerning leased cryogenic Dewars, which are owned and filled by the same vendor.
A qualified employee’s signature is required for verification.
1) Inner Pressure Vessel:
2) Relief Devices:
3) Dewar Piping
4) Filling and Installation
ASME Boiler and Pressure Vessel Code (BPVC) Section VIII List Code Used, if different: __
Both the pressure and vacuum relief devices must be sized and rated at the applicable set pressure per ASME Boiler and Pressure Vessel Code (BPVC) Section VIII or CGA S-1.3
ASME B31.3
The vendor is responsible for the safe filling and installation of the Dewar including adherence to CGA S-1.3, API 521, or other applicable code
5) All applicable code required examinations and tests shall be performed.
I certify all of the above statements to be true:
Vendor: ______________________________________________________
Qualified Employee (Print): ____________________________________
Qualified Employee (Signature): Date:
File details come from the government source that posted it. Updated .