Att 2_WBM Spec Response Matrix.xlsx
XLSX spreadsheet 19 KB Posted
- Attached to
- Workboat Medium Request for Proposal
- Solicitation number
- N00024-21-R-2255
About this file
This document contains a Request for Proposal for Workboat Mediums and the related specification response matrix template. The Navy seeks up to fifty-three Workboat Medium boats over seven years through an Indefinite Quantity/Indefinite Delivery contract awarded to a single offeror as the best value using lowest price technically acceptable evaluation. The boats must meet commercial standards and government specifications to provide workboats for naval shipyards and shore installations for duties including drydocking assistance, security barrier operations, towing, line handling, cargo transport, firefighting and diver support. Propulsion must maximize bollard pull and maneuverability while the climate-controlled cabin shelters operators from weather. Offerors must submit the specification response matrix with boat parameters and supporting documentation, and either indicate compliance with specifications or provide rationale for exceptions along with alternative approaches.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Att 2 Spec Response Matrix
| ATTACHMENT 2 |
| CNIC WORK BOAT MEDIUM |
| SPECIFICATION RESPONSE MATRIX Rev - |
NOTES & INSTRUCTIONS:
Offerors to submit Attachment 2 with response for parameters identified in the Specification (See Section J).
1. Where specific parameters or other technical information are required in the Specification (indicated by red text in the Specification), Offerors shall fill in the specific parameters/information for their proposed design for each boat configuration (as applicable) in this attachment and include supporting data in Vol I as directed. At bottom Offerors shall respond with 'Comply' to indicate their design meets all Specification requirements; or 'Comply w/Exceptions' to indicate disagreement with any specific section of the Specification.
2. A response of 'Comply w/Exceptions' shall be accompanied by amplifying notes in the 'Offeror's Notes' section at bottom, providing rationale for any exceptions. Each exception shall list the Specification section, the specific rationale for non-compliance with the section, and a proposed alternative approach. Any proposed alternative approach must meet the minimum requirement of the Specification to the Government's satisfaction. Description of Offeror's alternative approach shall include the detailed approach to achieving the minimum Specification requirement; applicable material specifications, make and model numbers for all parts/components; compliance with any requisite commercial or military standard, or associated “best practice”; and shall include any supporting product performance, test data, or other empirical evidence for the proposed product or service capability where applicable. The Government reserves the right to reject (without discussion) any proposed alternative which is incomplete or fails to meet minimum requirements of the Specification.
3. A response is required for each Specification section identified herein. The Government reserves the right to evaluate incomplete responses as non-compliant with the Specification and unacceptable for Factor 1 (Technical Approach).
| Specification Item | Specification Parameter |
| 070-1 | Enter Length Overall (LOA) including fendering and appendages: xx.xx feet (ft) |
| 070-1 | Enter Hull Length (Welded Structure Only): xx.xx ft |
[Shall be 29-30 ft] 070-1 Enter Beam Overall (BOA) including fendering: xx.x ft [Shall not exceed 15 ft]
| 070-1 | Enter Maximum Beam (Welded Structure only): xx.x ft |
| 070-1 | Enter Height, Lowest Appendage (skeg) to Fixed Structure (Overhead Line Guard): xx.x ft |
| 070-1 | Enter Height, Lowest Appendage to Moveable Structure (highest mast or antenna): xx.x ft |
| 070-1 | Enter Air Draft, Minimum Operation Condition waterline to Overhead Line Guard: xx.x ft |
[Shall not exceed of 13 ft] 070-1 Enter Height when Rigged for Transport (cabin and pusher knees removed): xx.x ft [Shall not exceed of 11 ft] 070-1 Enter Width when Rigged for Transport: xx.x ft [Shall not exceed 15 ft]
| 070-1 | Enter Total Installed Fuel Capacity: xxx gallons [Shall be minimum of 400 gallons] |
| 070-1 | Enter Full Load Displacement (as defined in Section 070): xx,xxx lbs incl x% construction or build margin or both |
| 070-1 | Enter Longitudinal Center of Gravity (LCG) in Full Load: xx.x ft forward of transom/keel intersect |
| 070-1 | Enter Static Full Load Draft (Hull): x.x ft |
| 070-1 | Enter Static Full Load Draft (to skegs): x.x ft |
[Shall not exceed 8 ft] 070-1 Enter Static Freeboard at the transom in the Min Op Condition: x.x ft [Shall not exceed 25 inches] 070-1 Enter Bollard Thrust in the forward direction in Min Op Condition: x,xxx lbs [Shall be minimum of 16,000 lbs] 070-1 Enter Bollard Thrust in the reverse direction in Min Op Condition: x,xxx lbs [Shall be minimum of 10,000 lbs] 070-1 Enter Sprint Speed (at x,xxx engine RPM): xx knots (kts) at Full Load in calm water [Shall be minimum of 6.5 knots]
| 100-1 | General Requirements for Hull Structure - Provide name and short description of structural methodology. |
| 233-1 | Inboard Diesel Engines - Verify that the minimum required speed and static bollard pull can be achieved on the proposed boat using the specified engines and marine gears. |
| All | Work Boat Docking Medium - Enter "Comply"; or enter "Comply w/Exceptions" AND provide rationale for exceptions in notes below. If “or equal” equipment is proposed, Offeror shall provide documentation demonstrating compliance with Specification Section 042-3. |
| Offeror's Notes: |
&12RFP N00024-21-R-2255 &10
&P of &N
Example Response
| ATTACHMENT 2 |
| CNIC WORK BOAT X |
| SPECIFICATION RESPONSE MATRIX - EXAMPLE RESPONSE |
See below for partial example responses.
Specification Item Specification Parameter Offeror Response (See Note 1)
| 070-1 | Enter Length Overall (LOA): xx.xx feet (ft) | 40.5 ft |
| 070-1 | Enter Hull Length (Lhull): xx.xx ft | 39.5 ft |
| 070-1 | Enter Beam Overall (BOA): xx.x ft | 16.0 ft |
| 070-1 | Enter Maximum Speed (at x,xxx engine RPM): xx knots (kts) at Full Load in calm water | 9.5 kts at 2,100 rpm |
| 070-2 | Enter list of submitted drawings describing the proposed boat. | 100-123456 Gen'l Arr |
100-123457 Transport (Continue per Sect L)
| 223-1 | Inboard Diesel Engines - Verify speeds and static bollard pull required in Spec can be achieved on proposed boat using specified engines. | Verified |
| All | CNIC Work Boat X Specification - Enter "Comply"; or enter "Comply w/ Exceptions" AND provide rationale for exceptions in notes below. | Comply w/ Exceptions |
| Offeror's Notes: | ||
| 581-1: Exception: Offeror has no local distributor for Fortress anchors and has assessed alternatives in accordance with Specification Section 042-3. Offeror proposes a BrandX Model xxx123 anchor in lieu of a Fortress anchor specified. A catalog sheet for BrandX Model xxx123 is included in Vol I. Offeror has provided BrandX anchors in 300 boats in similar sizes and applications. |
RFP N00024-21-R-2255