This file contains construction drawings and specifications for a renovation project at the National Interagency Fire Center (NIFC) Building 300, Suites 222 and 227, located at 3833 Development Avenue, Boise, Idaho. The project scope includes tenant improvements to Suites 222 and 227 on the second floor, renovation of restrooms on that floor, and conversion of an existing breakroom in Suite 203 into additional open office space as an additive alternate. The project is classified as a Level 2 Alteration under the 2024 International Existing Building Code, affecting less than 50 percent of the building area and not changing occupancy or means of egress except within affected suites.
The drawings indicate construction type IIB with fire sprinkler protection throughout, and compliance with 2024 International Building Code, International Existing Building Code, International Fire Code, NFPA 101 Life Safety Code, and Architectural Barriers Act standards. The project increases occupant load from 29 to 91 occupants in Suites 222/227, requiring updates to plumbing fixtures, fire protection systems, HVAC, electrical, and telecommunications infrastructure. Specific deliverables include new hollow metal doors and frames with hardware scheduling, solid surface countertops and window sills, resilient and ceramic tile flooring, acoustic ceiling grid and tiles, gypsum board wall construction with paint finishes, fire sprinkler system modifications, fire alarm device coordination, and comprehensive utility coordination across all building systems. The drawings are marked as 100% issued for construction dated May 8, 2026, with project identification number 070117.029 and BLM project number 140L062F0116.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STOPSTOP
BOLLARD
MCP
MCP
Vehicle Mail
DESIGNERS
ALWAYS THINK SAFETY
Project #
Sh ee t T itl e:
Date:
BLM Project #
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
D ra w n by
R ev is io ns
/1
5/
:2
AM
\\n wi nd en v.
co m
\n wi
2\
LB
YD
F ed er al P ro je ct F ile s\
-A ct ive
P ro je ct s\
.0
NI
FC
-J
W H
St es
\0
Dr aw in gs \C
AD
\0
7.
9G -0
_N
IF
C
- 2
_2
.d wg
Ap pr ov ed b y:
C he ck ed b y:
D es ig ne d by
Seal:
De sc rip tio n
Da te
Sheet of 86
05/08/2026
070117.029
140L062F0116
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
NA
TI
O
NA
L
IN
TE
RA
G
EN
CY
F
IR
E
CE
NT
ER
D ev el op m en t A ve
, B oi se , I
D
8)
-5
0%
IS
SU
ED
F O
R
CO
NS
TR
UC
TI
O N 0
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
/20
G-001
SJ
BD
N . F
R O
N G
N
ER
SJ
BD
SJ
BD
C O
VE
R
S H
EE
T
VICINITY MAPREFERENCE MAP
PROJECT LOCATION
LATITUDE: 43.567070°
LONGITUDE: -116.209100°
3833 DEVELOPMENT AVE, BOISE, ID 83705
NATIONAL INTERAGENCY FIRE CENTER
NIFC 300-JWH SUITE 222/227 RENOVATION
BOISE, IDAHO
PROJECT
LOCATION
NN
NIFC
CAMPUS
P R
O
FE
SSIONA L ENGINEER
NATHA N J. FRONGNER
STATE OF IDAHO
L I C E N S E D
18674
Nathan Frongner
2026.05.08 07:28:39-06'00' nfrongner@northwindgrp.com
DRAWING INDEX
SHEET
SUB
SHEET TITLE OF SHEET
GENERAL
1 G-001 COVER SHEET
2 G-002 INDEX SHEET
3 GI101 SECOND FLOOR LIFE SAFETY PLAN
4 GI102 CODE REVIEW
ARCHITECTURAL
5 AD101 SECOND FLOOR DEMOLITION OVERALL PLAN
6 AD120 SECOND FLOOR DEMO REFLECTED CEILING OVERALL PLAN
7 AD401 SECOND FLOOR DEMOLITION PLAN
8 AD402 SECOND FLOOR DEMOLITION PLAN
9 AD420 SECOND FLOOR DEMO REFLECTED CEILING PLAN
10 AD421 SECOND FLOOR DEMO REFLECTED CEILING PLAN
11 AE001 WALL TYPES AND NOTES
12 AE101 SECOND FLOOR OVERALL PLAN
13 AE120 SECOND FLOOR REFLECTED CEILING OVERALL PLAN
14 AE401 SECOND FLOOR PLAN
15 AE402 SECOND FLOOR PLAN
16 AE420 SECOND FLOOR REFLECTED CEILING PLAN
17 AE421 SECOND FLOOR REFLECTED CEILING PLAN
18 AE501 DOOR DETAILS
19 AE601 DOOR SCHEDULE AND ELEVATIONS
INTERIORS
20 IN101 FINISH FLOOR OVERALL PLAN
21 IN401 FINISH FLOOR PLAN
22 IN402 FINISH FLOOR PLAN
23 IN601 INTERIOR ELEVATIONS AND MATERIALS LIST
FIRE PROTECTION
24 FP001 FIRE PROTECTION SITE PLAN, NOTES AND LEGEND
25 FP101 FIRE PROTECTION OVERALL DEMOLITION PLAN
26 FP401 FIRE PROTECTION DEMOLITION PLAN
27 FP402 FIRE PROTECTION DEMOLITION PLAN
28 FP111 FIRE PROTECTION OVERALL PLAN
29 FP411 FIRE PROTECTION PLAN
30 FP412 FIRE PROTECTION PLAN
31 FA001 FIRE ALARM AND MASS NOTIFICATION LEGEND
32 FA002 FIRE ALARM RISER DIAGRAM AND DETAILS
33 FA101 FIRE ALARM DEMOLITION PLAN - OVERALL
34 FA401 FIRE ALARM DEMOLITION PLAN
35 FA402 FIRE ALARM DEMOLITION PLAN
36 FA111 FIRE ALARM PLAN - OVERALL
37 FA411 FIRE ALARM PLAN
38 FA412 FIRE ALARM PLAN
PLUMBING
39 P-001 PLUMBING LEGEND
40 PD101 SECOND FLOOR PLUMBING DEMOLITION PLAN
41 P-101 SECOND FLOOR OVERALL PLUMBING PLAN
42 P-102 SECOND FLOOR PLUMBING PLAN
43 P-103 SECOND FLOOR PLUMBING / SCHEDULE / DETAILS
MECHANICAL
44 M-001 LEGEND, NOTES AND ABBREVIATIONS
45 MH101 SECOND FLOOR HVAC DEMOLITION OVERALL PLAN
46 MH401 ENLARGED HVAC DEMOLITION PLANS
47 MH402 ENLARGED HVAC DEMOLITION PLANS
48 MP101 SECOND FLOOR HYDRONICS DEMOLITION OVERALL PLAN
49 MP401 ENLARGED HYDRONICS DEMOLITION PLANS
50 MP402 ENLARGED HYDRONICS DEMOLITION PLANS
51 MH111 SECOND FLOOR HVAC OVERALL PLAN
52 MH411 ENLARGED HVAC PLANS
53 MH412 ENLARGED HVAC PLANS
54 MP111 SECOND FLOOR HYDRONICS OVERALL PLAN
55 MP411 ENLARGED HYDRONICS PLANS
56 MP412 ENLARGED HYDRONICS PLANS
57 M-501 DETAILS
58 M-502 DETAILS
59 M-503 DETAILS
60 M-601 SCHEDULES
ELECTRICAL
61 E-001 ELECTRICAL LEGEND, NOTES AND ABBREVIATIONS
62 EP101 ELECTRICAL POWER DEMOLITION OVERALL PLAN
63 EP401 ELECTRICAL POWER DEMOLITION PLAN
64 EP402 ELECTRICAL POWER DEMOLITION PLAN
65 EL101 ELECTRICAL LIGHTING DEMOLITION OVERALL PLAN
66 EL401 ELECTRICAL LIGHTING DEMOLITION PLAN
67 EL402 ELECTRICAL LIGHTING DEMOLITION PLAN
68 ET101 TELECOMMUNICATIONS DEMOLITION OVERALL PLAN
69 ET401 TELECOMMUNICATIONS DEMOLITION PLAN
70 ET402 TELECOMMUNICATIONS DEMOLITION PLAN
71 ED601 ELECTRICAL DEMOLITION SCHEDULES
72 ED602 ELECTRICAL DEMOLITION SCHEDULES
73 EP111 ELECTRICAL POWER OVERALL PLAN
74 EP411 ELECTRICAL POWER PLAN
75 EP412 ELECTRICAL POWER PLAN
76 EL111 ELECTRICAL LIGHTING OVERALL PLAN
77 EL411 ELECTRICAL LIGHTING PLAN
78 EL412 ELECTRICAL LIGHTING PLAN
79 ET111 TELECOMMUNICATIONS OVERALL PLAN
80 ET411 TELECOMMUNICATIONS PLAN
81 ET412 TELECOMMUNICATIONS PLAN
82 EI101 ACCESS CONTROL PLAN
83 E-501 ELECTRICAL DETAILS
84 E-601 ELECTRICAL SCHEDULES
85 E-602 ELECTRICAL SCHEDULES
86 E-603 ELECTRICAL SCHEDULES
ALWAYS THINK SAFETY
Project #
Sh ee t T itl e:
Date:
BLM Project #
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
D ra w n by
R ev is io ns
/1
5/
:2
AM
\\n wi nd en v.
co m
\n wi
2\
LB
YD
F ed er al P ro je ct F ile s\
-A ct ive
P ro je ct s\
.0
NI
FC
-J
W H
St es
\0
Dr aw in gs \C
AD
\0
7.
9G -0
_N
IF
C
- 2
_2
.d wg
Ap pr ov ed b y:
C he ck ed b y:
D es ig ne d by
Seal:
De sc rip tio n
Da te
Sheet of 86
05/08/2026
070117.029
140L062F0116
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
NA
TI
O
NA
L
IN
TE
RA
G
EN
CY
F
IR
E
CE
NT
ER
D ev el op m en t A ve
, B oi se , I
D
8)
-5
0%
IS
SU
ED
F O
R
CO
NS
TR
UC
TI
O N 0
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
/20
G-002
SJ
BD
N . F
R O
N G
N
ER
SJ
BD
SJ
BD
SH
EE
T
IN
D
EX
P R
O
FE
SSIONA L ENGINEER
NATHA N J. FRONGNER
STATE OF IDAHO
L I C E N S E D
18674
Nathan Frongner
2026.05.08 07:28:46-06'00' nfrongner@northwindgrp.com
OPEN OFFICE
3117 SF
Occupant Load : 31
OFFICE
222C
104 SF
Occupant Load : 2
OFFICE
222D
104 SF
Occupant Load : 2
OFFICE
222E
104 SF
Occupant Load : 2
COMM
222A
31 SF
Occupant Load : 1 ELEC 222B
33 SF
Occupant Load : 1
BREAKROOM
366 SF
Occupant Load : 26
WOMEN
MEN
EX
IT
A C
C
ES
S
TR
AV
EL
D
IS
TA
N
C E=
'-2
COMMON PATH OF EGRESS
TRAVEL DISTANCE=70'-10"
.4"
13.05"36"
EX
IT
A C
C
ES
S
TR
AV
EL
D
IS
TA
N
C E=
9'
-1 1"
ELEV
FEC
FEC
FEC
FEC
HALL
EX
IT
A C
C
ES
S
TR
AV
EL
D
IS
TA
N
C E=
'-6
13.05"
36"
FOCUS
53 SF
Occupant Load : 4
OFFICE
222G
99 SF
Occupant Load : 2
OFFICE
222F
99 SF
Occupant Load : 2
OPEN OFFICE
1257 SF
Occupant Load : 9
PREDICTIVE SERVICES
203C
265 SF
Occupant Load : 2
PREDICTIVE SERVICES
203B
166 SF
Occupant Load : 2
17.4"
56"
88888 SF= ######
ROOM NAME
EXIT PATH
SPACE AREA
OCCUPANCY TAG:
NUMBER OF OCCUPANTS
OCCUPANT LOAD FACTOR
EXISTING 1 HOUR FIRE BARRIER - PER CODE
REVIEW, FIRE RATING IS NO LONGER NEEDED
AND WILL NOT BE MAINTAINED
FIRE EXTINGUISHER CABINET AND
EXTINGUISHER - SEE SPECIFICATIONSFEC
SURFACE MOUNTED FIRE EXTINGUISHER -
SEE SPECIFICATIONS FE
NOTE: SEE ELECTRICAL FOR ILLUMINATED EXIT SIGNS.
CODE PLAN LEGEND
ROOM / AREA NAME
ROOM / AREA NUMBER
EXIT TAG:
REQUIRED WIDTH
OCCUPANT LOAD
PROVIDED WIDTH
EXISTING FIRE EXTINGUISHER CABINET
AND EXTINGUISHER TO REMAINFEC
EXISTING 1 HOUR RATED CEILING - PER CODE
REVIEW, FIRE RATING IS NO LONGER NEEDED
AND WILL NOT BE MAINTAINED
EXISTING 1 HOUR FIRE BARRIER TO REMAIN AT
STAIR ENCLOSURE, DO NOT PENETRATE
FINISH FLOOR
4'
- 6
TO
H
AN
DL
E 4'
- 0
MA
X
SEMI-RECESSED FIRE
EXTINGUISHER
CABINET
PORTABLE
FIRE
EXTINGUISHER
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:2
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R L
IF
E
SA
FE
TY
P
LA
N
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
GI101
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
3 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
A1 SECOND FLOOR CODE PLAN
0 4' 8' 16' 24'
N
GENERAL SHEET NOTES
A. SEE SHEET GI102 FOR CODE ANALYSIS.
B4 EXTINGUISHER MOUNTING HEIGHTS
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
/20
GOVERNING CODES:
2024 INTERNATIONAL BUILDING CODE
2024 INTERNATIONAL EXISTING BUILDING CODE
2024 INTERNATIONAL FIRE CODE
2024 INTERNATIONAL FUEL GAS CODE
2024 INTERNATIONAL MECHANICAL CODE
2024 INTERNATIONAL PLUMBING CODE
2024 INTERNATIONAL WILDLAND-URBAN INTERFACE CODE
2024 INTERNATIONAL ENERGY CONSERVATION CODE
2024 NFPA 101 LIFE SAFETY CODE
ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY STANDARDS
*SHOULD A CONFLICT EXIST BETWEEN BLM ADOPTED CODES AND STATE OR LOCAL
CODES, BLM ADOPTED CODES SHALL PREVAIL
PROJECT SUMMARY:
THE PROJECT SCOPE CONSISTS OF A TENANT IMPROVEMENT TO SUITE 222 AND 227 ON
THE SECOND FLOOR OF NIFC BUILDING 300, RENOVATION OF THE RESTROOMS ON THAT
FLOOR, AND CONVERSION OF AN EXISTING BREAK ROOM IN SUITE 203 INTO ADDITIONAL
OPEN OFFICE SPACE. THE PROJECT WILL NOT CHANGE OCCUPANCY OR MEANS OF
EGRESS, EXCEPT FOR THE EXIT PATH WITHIN THE AFFECTED SUITES. THE PROJECT
AREA WILL BE LESS THAN 50% OF THE BUILDING AREA. ALL WORK IN SUITE 203 WILL BE
DONE AS AN ADDITIVE ALTERNATE.
IEBC 2024 ANALYSIS:
CLASSIFICATION OF WORK: LEVEL 2 ALTERATION
603.1 LEVEL 2 ALTERATIONS INCLUDE THE ADDITION OR ELIMINATION OF ANY DOOR OR
WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE
INSTALLATION OF ANY ADDITIONAL EQUIPMENT, AND SHALL APPLY WHERE THE WORK
AREA IS EQUAL TO OR LESS THAN 50 PERCENT OF THE BUILDING AREA.
603.2 LEVEL 2 ALTERATIONS SHALL COMPLY WITH PROVISIONS OF CHAPTER 7 AND 8
701.2 AN EXISTING BUILDING OR PORTION THEREOF SHALL NOT BE ALTERED SUCH
THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITION.
EXCEPTION: WHERE THE CURRENT LEVEL OF SAFETY IS PROPOSED TO BE
REDUCED, THE PORTION ALTERED SHALL CONFORM TO THE REQUIREMENTS OF THE
INTERNATIONAL BUILDING CODE.
703.1 ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF FIRE
PROTECTION PROVIDED.
801.4 NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND SPACES SHALL
COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.
802.4 THE INTERIOR FINISH AND TRIM OF WALLS AND CEILINGS IN EXITS AND
CORRIDORS IN ANY WORK AREA SHALL COMPLY WITH THE REQUIREMENTS OF THE
INTERNATIONAL BUILDING CODE.
803.1.1 WHERE AN APPROVED AUTOMATIC SPRINKLER SYSTEM IS INSTALLED
THROUGHOUT THE STORY, THE REQUIRED FIRE-RESISTANCE RATING FOR ANY
CORRIDOR LOCATED ON THE STORY SHALL BE PERMITTED TO BE REDUCED IN
ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE.
809.1 LEVEL 2 ALTERATIONS TO EXISTING BUILDINGS ARE PERMITTED WITHOUT
REQUIRING THE ENTIRE BUILDING TO COMPLY WITH THE ENERGY REQUIREMENTS OF
THE INTERNATIONAL ENERGY CONSERVATION CODE. ALTERATIONS SHALL CONFORM
TO THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION
CODE AS THEY RELATE TO NEW CONSTRUCTION ONLY.
IBC 2024 ANALYSIS
OCCUPANCY CLASSIFICATION: B (BUSINESS) PER SECTION 304.1
BUILDING OCCUPANCY HAS NOT BEEN ALTERED FROM EXISTING
FIRE SPRINKLER SYSTEM: PROVIDED
CONSTRUCTION TYPE: IIB PER SECTION 602.2
BUILDING HEIGHT, AREA, AND NUMBER OF STORIES: NOT ALTERED FROM EXISTING
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS FROM TABLE 601
FOR TYPE IIB, ALL ELEMENTS EXCEPT EXTERIOR WALLS = 0 HOURS
SECTION 602.2 TYPES I AND II
TYPES I AND II CONSTRUCTION ARE THOSES TYPES OF CONSTRUCTION IN WHICH
THE BUILDING ELEMENTS SPECIFIED IN TBALE 601 ARE OF NONCOMBUSTIBLE
MATERIALS, EXCEPT AS PERMITTED IN SECTION 603 AND ELSEWHERE IN THIS CODE.
CHAPTER 7 RATED / PROTECTED ASSEMBLIES NOT ALTERED FROM EXISTING
INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY FROM TABLE
803.13
FOR GROUP B, SPRINKLERED (MOST STRINGENT):
EXIT ENCLOSURES AND EXIT PASSAGEWAYS = B
CORRIDORS & STIARWAYS = C
ROOMS AND ENCLOSED SPACES = C
OCCUPANT LOAD FACTOR FROM TABLE 1004.5:
BUSINESS AREAS = 150 GROSS
EXISTING SECOND FLOOR = 16,785 / 150 = 112 OCCUPANTS
EXISTING SUITE 222/227 = 4,245 SF / 150 = 29 OCCUPANTS
NEW SUITE 222/227 = 91 OCCUPANTS (SEE CODE PLAN)
ADDITIONAL (NEW - EXISTING) = 62
TOTAL (EXISTING + ADDITIONAL) = 174 OCCUPANTS
MINIMUM REQUIRED EGRESS WIDTH FROM SECTION 1005.3
STAIRWAYS, SPRINKLERED, GROUP B = 0.2 INCHES PER OCCUPANT
OTHER EGRESS COMPONENTS, SPRINKLERED, GROUP B = 0.15 INCHES PER
OCCUPANT
SEE CODE PLANS FOR REQUIRED AND PROVIDED EXIT WIDTHS
COMMON PATH OF EGRESS TRAVEL PER TABLE 1006.2.1 =
FOR B OCCUPANCY ROOMS = SHALL NOT EXCEED 100 FEET
SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY FROM TABLE 1006.2.1
FOR B OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 49
EXIT ACCESS TRAVEL DISTANCE FROM TABLE 1017.2
FOR B OCCUPANCY, WITH SPRINKLER SYSTEM = 300 FEET
CORRIDOR FIRE-RESISTANCE RATING FROM TABLE 1020.2
FOR B OCCUPANCY, WITH SPRINKLER SYSTEM = NO RATING IS REQUIRED
MINIMUM CORRIDOR WIDTH PER TABLE 1020.3 = 44 INCHES.
DEAD END CORRIDORS FROM SECTION 1020.5 EXCEPTION 2
FOR B OCCUPANCY, SPRINKLERRED = NO MORE THAN 50 FEET
MINIMUM NUMBER OF PLUMBING FIXTURES PER IBC TABLE 2902.1
BASED ON BUSINESS OCCUPANCY
174 OCCUPANTS = 87 MALE, 87 FEMALE
WATER CLOSETS:
1 PER 25 FOR THE FIRST 50 AND 1 PER 50 FOR THE REMAINDER EXCEEDING 50
PER IPC 424.2, URINAL SHALL NOT BE SUBSTITUTED FOR MORE THAN 50
PERCENT OF REQUIRED WATER CLOSETS
REQUIRED: 3 MALE, 3 FEMALE
PROVIDED: 4 MALE, 4 FEMALE
LAVATORIES:
1 PER 40 FOR THE FIRST 80 AND 1 PER 80 FOR THE REMAINDER EXCEEDING 80 FOR
BOTH MALE AND FEMALES
REQUIRED: 3 MALE, 3 FEMALE
PROVIDED: 3 MALE, 3 FEMALE
DRINKING FOUNTAINS:
1 PER 100
REQUIRED: 2 TOTAL
PROVIDED: 2 TOTAL
SERVICE SINK:
REQUIRED: 1 TOTAL
PROVIDED: 1 TOTAL
NFPA 101 2024 CODE ANALYSIS
OCCUPANCY: EXISTING BUSINESS
STORIES: 3
CONSTRUCTION TYPE: II-000 SPRINKLERED
PER NFPA 220 TABLE 4.1.1 -
TYPE II-000 - BUILDING ELEMENTS REQUIRE NO RATING.
7.1.3.1.2 EXIT ACCESS CORRIDORS TO BE RATED PER CHAPTER 39 (SEE 39.3.6)
39.1.1.1 - CLASSIFICATION OF HAZARD CONTENTS - ORDINARY
39.2.2 ARRANGEMENTS OF MEANS OF EGRESS IS AS FOLLOWS:
39.2.4.2 - SINGLE EXIT ACCESS PATHS PERMITTED FOR COMMON PATHS OF
TRAVEL DISTANCE PER 39.2.5.2
39.2.5.2.1 - COMMON PATH OF TRAVEL = 100' MAXIMUM
39.2.5.3 - DEAD END CORRIDORS = 50' MAXIMUM
39.2.6.3 - MAXIMUM TRAVEL DISTANCE = 300'
39.3.6 CORRIDORS - NO REQUIREMENTS
ABA CODE ANALYSIS
F202.3 ALTERATIONS
WHERE EXISTING ELEMENTS OR SPACES ARE ALTERED, EACH ALTERED ELEMENT OR
SPACE SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF CHAPTER 2.
F202.4 ALTERATIONS AFFECTING PRIMARY FUNCTION AREAS
PRIMARY FUNCTION AREAS ARE ALL LOCATED ON ACCESSIBLE ROUTES. RESTROOMS
ON SECOND FLOOR ARE CURRENTLY ACCESSIBLE TO OCCUPANTS AND ON ACCESSIBLE
ROUTES TO ALL PROJECT AREAS.
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:2
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
C O
D E
R
EV
IE
W
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
GI102
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
4 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
CODE REVIEW INFORMATION
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
1 2 3 4 5 6 7 8 9 10 11 1312
A
B
C
D
E
F
G
I
J
K
L
M
T
U
V
2A
ELEC
222B
COMM
222A
JAN
MEN
WOMEN
HALL
HALL
HALL
HALL
PREDICTIVE SERVICES
203B
ELEV.
VEST.
OPEN OFFICE
PREDICTIVE SERVICES
203C
DISPATCH
HALL
STAIR
#2
STAIR
#1
AVIATION MGNT CHIEF
222C
OFFICE
LIBRARY
AVIATION MGMT
OFFICE
FIRE SCIENCE
FIRE MANAGEMENT
OFFICE
CONFERENCE
STORAGE
202B
STORAGE
AD401
A1
AD402
A1
AD402
A3
EXISTING ROOM NAME AND NUMBER
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DIMENSION TO FACE OF FRAMING
DIMENSION TO GRID LINE
XXX000
SIM
NAME
X
DEMO PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
ITEMS TO BE DEMOLISHED
ITEMS TO REMAIN
A.
B.
C.
D.
E.
THESE DRAWINGS ARE BASED UPON EXISTING
DRAWINGS AND SITE OBSERVATIONS. THE
CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL
CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING
WORK.
PROTECT ALL EXISTING ITEMS TO REMAIN FROM
DAMAGE. PATCH AND REPAIR ALL ITEMS DAMAGED
DURING CONSTRUCTION, INCLUDING VOIDS AND
FINISHES RESULTING FROM DEMOLITION REMOVALS.
MATCH ADJACENT EXISTING CONSTRUCTION FOR ALL
NEW CONSTRUCTION.
SEE FIRE PROTECTION, PLUMBING, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR ADDITIONAL
REQUIREMENTS.
WHERE EXISTING FLOOR FINISHES ARE REMOVED, PREP
SLAB AND/OR UNDERLAYMENT AS REQUIRED TO
RECEIVE NEW FLOOR FINISHES NOTED.
GENERAL SHEET NOTES
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:2
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R D
EM
O
LI
TI
O N
O
VE
R
AL
L
PL
AN
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AD101
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
5 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
A1 SECOND FLOOR OVERALL DEMOLITION PLAN
0 4' 8' 16' 24'
N
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
Q
I
1 2 3 4 5 6 7 8 9 10 11 1312
A
B
C
D
E
F
G
I
J
K
L
M
T
U
V
2A
AVIATION MGNT CHIEF
LIBRARY 222
OFFICE
222C
OFFICE
AVIATION MGMT
222A
COMM
222B
ELEC.
STORAGE
202B
STORAGE
202A
HALL
HALL
HALL
ELEV.
VEST.
201PREDICTIVE SERVICES
203B
PREDICTIVE SERVICES
203C
OPEN OFFICE
BREAKROOM
HALL
HALL
STAIR
#2
OFFICE
FIRE SCIENCE
FIRE MANAGEMENT
CONFERENCE
WOMEN
MEN
JAN
AD420
A1
AD421
A1
AD421
A3
A.
B.
C.
D.
E.
THESE DRAWINGS ARE BASED UPON EXISTING
DRAWINGS AND SITE OBSERVATIONS. THE
CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL
CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING
WORK.
PROTECT ALL EXISTING ITEMS TO REMAIN FROM
DAMAGE. PATCH AND REPAIR ALL ITEMS DAMAGED
DURING CONSTRUCTION, INCLUDING VOIDS AND
FINISHES RESULTING FROM DEMOLITION REMOVALS.
MATCH ADJACENT EXISTING CONSTRUCTION FOR ALL
NEW CONSTRUCTION.
SEE FIRE PROTECTION, PLUMBING, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR ADDITIONAL
REQUIREMENTS.
EXISTING CEILINGS AND ASSOCIATED MECHANICAL AND
ELECTRICAL ELEMENTS ARE SHOWN FOR
COORDINATION PURPOSES FOR THE NECESSARY
DISCIPLINES. VERIFY ALL ITEMS IN FIELD.
GENERAL SHEET NOTES
EXISTING ROOM NAME AND NUMBER
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DIMENSION TO FACE OF FRAMING
DIMENSION TO GRID LINE
XXX000
SIM
NAME
X
PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
ITEMS TO BE DEMOLISHED
ITEMS TO REMAIN
ACT CEILING TO BE DEMOLISHED. SEE
KEYNOTES FOR DETAILS.
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:3
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R D
EM
O
R
EF
LE
C
TE
D
C
EI
LI
N
G O
VE
R
AL
L
PL
AN
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AD120
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
6 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
A1 SECOND FLOOR DEMOLITION REFLECTED CEILING PLAN
0 4' 8' 16' 24'
N
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
1 2
OFFICE
AVIATION MGNT CHIEF 222C
OFFICE
LIBRARY
AVIATION MGMT
222A
COMM
222B
ELEC.
STORAGE
202B
STORAGE
202A
HALL
3 4 5 6 7 8 9 10 11 1312
A
B
C
D
E
F
G
I
J
HALL
HALL
HALL
1"
PREDICTIVE
SERVICES
203B
ELEV.
VEST.
1 2
FIRE SCIENCE
FIRE MANAGEMENT
OFFICE
CONFERENCE
HALL
8' - 10" 8' - 1 1/2"
6 6
AD402
A3
EXISTING ROOM NAME AND NUMBER
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DIMENSION TO FACE OF FRAMING
DIMENSION TO GRID LINE
XXX000
SIM
NAME
X
DEMO PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
ITEMS TO BE DEMOLISHED
ITEMS TO REMAIN
A.
B.
C.
D.
E.
THESE DRAWINGS ARE BASED UPON EXISTING
DRAWINGS AND SITE OBSERVATIONS. THE
CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL
CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING
WORK.
PROTECT ALL EXISTING ITEMS TO REMAIN FROM
DAMAGE. PATCH AND REPAIR ALL ITEMS DAMAGED
DURING CONSTRUCTION, INCLUDING VOIDS AND
FINISHES RESULTING FROM DEMOLITION REMOVALS.
MATCH ADJACENT EXISTING CONSTRUCTION FOR ALL
NEW CONSTRUCTION.
SEE FIRE PROTECTION, PLUMBING, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR ADDITIONAL
REQUIREMENTS.
WHERE EXISTING FLOOR FINISHES ARE REMOVED, PREP
SLAB AND/OR UNDERLAYMENT AS REQUIRED TO
RECEIVE NEW FLOOR FINISHES NOTED.
GENERAL SHEET NOTES
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:4
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R D
EM
O
LI
TI
O N
PL
AN
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AD401
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
7 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
A1 SECOND FLOOR DEMOLITION PLAN
1 DEMOLISH EXISTING WALL AND ASSOCIATED ITEMS TO
EXTENTS SHOWN. PATCH AND REPAIR ADJACENT
EXISTING WALLS TO REAMAIN WHERE DAMAGE OCCURS.
2 DEMOLISH EXISTING DOOR, FRAME AND ALL HARDWARE.
3 DEMOLISH EXISTING CARPET FLOORING WITHIN ROOM
NOTED. REMOVE EXISTING FLOORING DOWN TO
EXISTING CONCRETE SLAB AND PREP FOR NEW
FLOORING. REMOVED CARPET TO BE PALLETIZED FOR
RECYCLING. SEE SPECS FOR DETAILS.
4 DEMOLISH FURRING AT EXISTING COLUMN. COLUMN TO
REMAIN.
5 DEMOLISH EXISTING WINDOW SILL AND PREP FOR NEW
SOLID SURFACE SILL.
6 DEMOLISH EXISTING WINDOW SHADES. PREP FOR
REPLACEMENT SHADES.
7 DEMOLISH EXISTING CARPET FLOORING TO EXTENTS
SHOWN. REMOVE EXISTING FLOORING DOWN TO
EXISTING CONCRETE SLAB AND PREP FOR NEW LVT
FLOORING.
8 EXTENT OF EXISTING FLOOR DEMOLITION.
9 DEMOLISH EXISTING WINDOW SHADES. PREP FOR
REPLACEMENT SHADES.
10 DEMOLISH EXISTING LVT FLOORING. REMOVE EXISTING
FLOORING DOWN TO EXISTING CONCRETE AND PREP
FOR NEW FLOORING.
# SHEET KEYNOTES
0 4' 8' 16'
N
KEY PLAN
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
F
EXISTING ROOM NAME AND NUMBER
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DIMENSION TO FACE OF FRAMING
DIMENSION TO GRID LINE
XXX000
SIM
NAME
X
DEMO PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
ITEMS TO BE DEMOLISHED
ITEMS TO REMAIN
A.
B.
C.
D.
E.
THESE DRAWINGS ARE BASED UPON EXISTING
DRAWINGS AND SITE OBSERVATIONS. THE
CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL
CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING
WORK.
PROTECT ALL EXISTING ITEMS TO REMAIN FROM
DAMAGE. PATCH AND REPAIR ALL ITEMS DAMAGED
DURING CONSTRUCTION, INCLUDING VOIDS AND
FINISHES RESULTING FROM DEMOLITION REMOVALS.
MATCH ADJACENT EXISTING CONSTRUCTION FOR ALL
NEW CONSTRUCTION.
SEE FIRE PROTECTION, PLUMBING, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR ADDITIONAL
REQUIREMENTS.
WHERE EXISTING FLOOR FINISHES ARE REMOVED, PREP
SLAB AND/OR UNDERLAYMENT AS REQUIRED TO
RECEIVE NEW FLOOR FINISHES NOTED.
GENERAL SHEET NOTES
8 8
4 5
D
F
WOMEN
MEN
11 11
BREAKROOM
OPEN OFFICE
2 4
10 11 1312
I
J
K
L
HALL
ELEV.
VEST.
203C
PREDICTIVE SERVICES
203B
PREDICTIVE SERVICES
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:4
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R D
EM
O
LI
TI
O N
PL
AN
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AD402
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
8 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
# SHEET KEYNOTES
1 DEMOLISH EXISTING WALL AND ASSOCIATED ITEMS TO
EXTENTS SHOWN. PATCH AND REPAIR ADJACENT
EXISTING WALLS TO REAMAIN WHERE DAMAGE
OCCURS.
2 DEMOLISH EXISTING DOOR, FRAME AND ALL
HARDWARE.
4 DEMOLISH ALL CASEWORK AND APPLIANCES INCLUDING
REFRIGERATORS, MICROWAVES, COFFEE MACHINES,
AND ASSOCIATED PLUMBING.
5 DEMOLISH EXISTING LVT FLOORING. REMOVE EXISTING
FLOORING DOWN TO EXISTING CONCRETE AND PREP
FOR NEW FLOORING.
6 DEMOLISH EXISTING WINDOW SILL AND PREP FOR NEW
SOLID SURFACE SILL.
7 DEMOLISH EXISTING TILE FLOORING WITHIN ROOM
NOTED. REMOVE EXISTING FLOORING DOWN TO
EXISTING CONCRETE SLAB AND PREP FOR NEW
FLOORING.
8 DEMOLISH EXISTING BATHROOM PARTITIONS.
9 DEMOLISH EXISTING WINDOW SHADES. PREP FOR
REPLACEMENT SHADES.
10 DEMOLISH EXISTING EXHAUST VENT, SEE MECHANICAL.
11 DEMOLISH ALL EXISTING WALL TILE AND COORDINATING
EXISTING TILE WALL BASE. PREP ALL SURFACES FOR
NEW TILE INSTALLATION.
12 REMOVE ALL WALL HUNG PLUMBING COMPONENTS AND
PRESERVE FOR REINSTALLATION. SEE PLUMBING ALSO.
13 DEMOLISH ALL WALL AND PARTITION-HUNG RESTROOM
ACCESSORIES THROUGHOUT ROOM.
14 DEMOLISH EXISTING COUNTER, CASEWORK, AND
PLUMBING FIXTURES.
15 REMOVE AND PROTECT MIRROR TO BE RE-INSTALLED
AFTER PAINT AND CONSTRUCTION IS COMPLETE.
KEY PLAN
0 2' 4' 8'
N
A1 ADD ALTERNATE DEMOLITION PLAN A3 SECOND FLOOR DEMOLITION PLAN
0 4' 8' 16'
N
NOTE: ALL WORK IN THIS VIEW TO BE PART OF ADD ALTERNATE
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
Q
J
I
E
AVIATION MGNT CHIEF
LIBRARY
OFFICE
222C
OFFICE
AVIATION MGMT
222A
COMM
222B
ELEC.224
STORAGE
202B
STORAGE
202A
HALL
3 4 5 6 7 8 9 10 11 1312
A
B
C
D
E
F
G
I
J
1"
OFFICE
FIRE SCIENCE
FIRE MANAGEMENT
CONFERENCE
HALL
AD421
A3
202A
HALL
HALL
HALL
WOMEN
MEN
JAN
VEST
ELEV
203B
PREDICTIVE SERVICES
#1
STAIR
A.
B.
C.
D.
E.
THESE DRAWINGS ARE BASED UPON EXISTING
DRAWINGS AND SITE OBSERVATIONS. THE
CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL
CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING
WORK.
PROTECT ALL EXISTING ITEMS TO REMAIN FROM
DAMAGE. PATCH AND REPAIR ALL ITEMS DAMAGED
DURING CONSTRUCTION, INCLUDING VOIDS AND
FINISHES RESULTING FROM DEMOLITION REMOVALS.
MATCH ADJACENT EXISTING CONSTRUCTION FOR ALL
NEW CONSTRUCTION.
SEE FIRE PROTECTION, PLUMBING, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR ADDITIONAL
REQUIREMENTS.
EXISTING CEILINGS AND ASSOCIATED MECHANICAL AND
ELECTRICAL ELEMENTS ARE SHOWN FOR
COORDINATION PURPOSES FOR THE NECESSARY
DISCIPLINES. VERIFY ALL ITEMS IN FIELD.
GENERAL SHEET NOTES
EXISTING ROOM NAME AND NUMBER
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DIMENSION TO FACE OF FRAMING
DIMENSION TO GRID LINE
XXX000
SIM
NAME
X
PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
ITEMS TO BE DEMOLISHED
ITEMS TO REMAIN
ACT CEILING TO BE DEMOLISHED. SEE
KEYNOTES FOR DETAILS.
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:5
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R D
EM
O
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AD420
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
9 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
A1 SECOND FLOOR DEMOLITION REFLECTED CEILING PLAN
1 DEMOLISH EXISTING CEILING, GRIDS, SUSPENSION
SYSTEMS, AND LIGHT FIXTURES IN THEIR ENTIRETY.
SEE FIRE, PLUMBING, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR OTHER WORK TO
OCCUR WITHIN ROOM.
2 EXISTING CEILING TO REMAIN. REMOVE GRID AND
TILES AS NEEDED FOR ADJACENT WALL DEMOLITION
AND CONSTRUCTION. REINSTALL GRID AND TILES
AFTER WALL CONSTRUCTION IS COMPLETED.
3 DEMOLISH EXISTING CEILING TILE AND GRID AS
NEEDED FOR WALL DEMOLITION IN THIS AREA.
0 4' 8' 16'
N
# SHEET KEYNOTES
KEY PLAN
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
A.
B.
C.
D.
E.
THESE DRAWINGS ARE BASED UPON EXISTING
DRAWINGS AND SITE OBSERVATIONS. THE
CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL
CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING
WORK.
PROTECT ALL EXISTING ITEMS TO REMAIN FROM
DAMAGE. PATCH AND REPAIR ALL ITEMS DAMAGED
DURING CONSTRUCTION, INCLUDING VOIDS AND
FINISHES RESULTING FROM DEMOLITION REMOVALS.
MATCH ADJACENT EXISTING CONSTRUCTION FOR ALL
NEW CONSTRUCTION.
SEE FIRE PROTECTION, PLUMBING, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR ADDITIONAL
REQUIREMENTS.
EXISTING CEILINGS AND ASSOCIATED MECHANICAL AND
ELECTRICAL ELEMENTS ARE SHOWN FOR
COORDINATION PURPOSES FOR THE NECESSARY
DISCIPLINES. VERIFY ALL ITEMS IN FIELD.
GENERAL SHEET NOTES
EXISTING ROOM NAME AND NUMBER
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DIMENSION TO FACE OF FRAMING
DIMENSION TO GRID LINE
XXX000
SIM
NAME
X
PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
ITEMS TO BE DEMOLISHED
ITEMS TO REMAIN
ACT CEILING TO BE DEMOLISHED. SEE
KEYNOTES FOR DETAILS.
WOMEN
MEN
4 5
D
F
10 13
K
J
I
OPEN OFFICE
BREAKROOM
10 11 1312
I
J
K
L
202A
HALL
VEST
ELEV
#1
STAIR
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:0
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R D
EM
O
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AD421
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
10 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
1 DEMOLISH EXISTING CEILING, GRIDS, SUSPENSION
SYSTEMS, AND LIGHT FIXTURES IN THEIR ENTIRETY.
SEE FIRE, PLUMBING, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR OTHER WORK TO
OCCUR WITHIN ROOM.
2 EXISTING CEILING TO REMAIN. REMOVE GRID AND
TILES AS NEEDED FOR ADJACENT WALL DEMOLITION
AND CONSTRUCTION. REINSTALL GRID AND TILES
AFTER WALL CONSTRUCTION IS COMPLETED.
3 DEMOLISH EXISTING CEILING TILE AND GRID AS
NEEDED FOR WALL DEMOLITION IN THIS AREA.
4 EXISTING CEILING TO REMAIN. PATCH AND REPAIR
AS NEEDED FOR OTHER WORK TO OCCUR IN THIS
ROOM.
# SHEET KEYNOTES
KEY PLAN
0 2' 4' 8'
N
A1
ADD ALTERNATE DEMOLITION REFLECTED CEILING
PLAN A3 SECOND FLOOR DEMOLITION REFLECTED CEILING PLAN
0 4' 8' 16'
N
NOTE: ALL WORK IN THIS VIEW TO BE PART OF ADD ALTERNATE
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
SCALE: 1" = 1'-0"
B.
C.
1.
GENERAL WALL TYPE NOTES:
SEE INTERIOR FINISH SCHEDULE (SHEET INT-600)
AND FOR WALL FINISHES.
PROVIDE BLOCKING AS REQUIRED TO SECURE
WALL HUNG COMPONENTS.
EXTEND ALL COMPONENTS TO UNDERSIDE OF
DECK, UNLESS NOTED OTHERWISE.
WALL TYPE MODIFIERS:
NOT USED.
WALL TYPE LEGEND
WALL TYPE DESCRIPTION
W1
WALL ASSEMBLIES
A
3 5/8" METAL STUDS AT 16" O.C.
5/8" TYPE 'X' GYPSUM BOARD
3 5/8" PARTITION - STC 45 MIN
SOUND BATT INSULATION
B
3 5/8" METAL STUDS AT 16" O.C.
5/8" TYPE 'X' GYPSUM BOARD
3 5/8" FURRING WALL
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:0
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
W
AL
L
TY
PE
S
AN
D
N O
TE
S
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AE001
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
11 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
G
I
J
K
L
M
T
U
V
2A
ELEC
222B
COMM
222A
OPEN OFFICE
OFFICE
222E
OFFICE
222D
OFFICE
222C
OPEN OFFICE
OFFICE
222F
OFFICE
222G FOCUS
JAN
MEN
WOMEN
HALL
HALL
HALL
HALL
PREDICTIVE
SERVICES
203B
ELEV.
VEST.
OPEN OFFICE
PREDICTIVE
SERVICES
203C
BREAKROOM
DISPATCH
HALL
STAIR
#2
STAIR
#1
AE401
A1
AE402
A1
AE402
A3
ASSEMBLY TYPE (SEE ASSEMBLIES SHEET)
ASSEMBLY MODIFIER, PER TYPE
ROOM NAME AND NUMBER
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DOOR NUMBER (SEE SHEET A601A)
DIMENSION TO FACE OF FRAMING
1-
XXX000
SIM
X
XX
NAME
X
PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
A.
B.
C.
D.
E.
F.
CONTRACTOR TO FIELD VERIFY ALL EXISTING
CONDITIONS
REFER TO CODE PLANS FOR LOCATIONS OF ANY
RATED DOORS AND ASSEMBLIES
FOR ANY WALLS NOT LABELLED, USE TYPE MOST
CONSISTENT WITH SIMILAR
APPLICATIONS/LOCATIONS.
ALL STUD WALLS TO HAVE 4" STUD RETURN AT
DOORS BETWEEN STUD OPENINGS TO
PERPENDICULAR WALL AT HINGE SIDE OF DOOR.
SEE AE001 FOR WALL TYPES AND NOTES.
SEE CIVIL, STRUCTURAL, FIRE PROTECTION,
PLUMBING, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL REQUIREMENTS.
GENERAL SHEET NOTES
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:0
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R O
VE
R
AL
L
PL
AN
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AE101
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
12 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
A1 SECOND FLOOR OVERALL PLAN
0 4' 8' 16' 24'
N
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
Q
I
1 2 3 4 5 6 7 8 9 10 11 1312
A
B
C
D
E
F
G
I
J
K
L
M
T
U
V
2A
222A
COMM
222B
ELEC.
202A
HALL
HALL
HALL
ELEV.
VEST.
201PREDICTIVE SERVICES
203B
PREDICTIVE SERVICES
203C
OPEN OFFICE
HALL
HALL
STAIR
#2
OPEN OFFICE
OPEN OFFICE
OFFICE
222G
OFFICE
222F FOCUS
OFFICE
222C
OFFICE
222D
OFFICE
222E
BREAKROOM
WOMEN
MEN
STAIR
#1
AE420
A1
AE421
A1
AE421
A3
CEILING MATERIAL
CEILING HEIGHT
ADDITIONAL NOTES
ACT
2X4 ACOUSTICAL
LAY-IN CEILING
NOTES
ACT
0'-0 0/0"
REFLECTED CEILING LEGEND
LIGHTING -
SEE ELECTRICAL
HVAC
REGISTERS -
SEE
MECHANICAL
CEILING HEIGHT
VAR VARIES
ADDITIONAL NOTES
1. EXISTING CEILING. CUT AND PATCH AS NEEDED TO
ACCOMODATE NEW WORK. PROVIDE SUPPORT
WHERE CEILING IS CUT AS NEEDED.
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:1
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R R
EF
LE
C
TE
D C
EI
LI
N G
O
VE
R
AL
L
PL
AN
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AE120
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
13 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
A1 SECOND FLOOR REFLECTED CEILING OVERALL PLAN
0 4' 8' 16' 24'
N
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
OFFICE
222C
OFFICE
222D
OFFICE
222E
COMM
222A
ELEC
222B
BREAKROOM
IN600
WOMEN
MEN
IN600
5' - 5" 9' - 1" 9' - 1" 9' - 7"
3'
9" 8'
7"
A A A A
A
A
A
A
A
A
2C
2D
2E
E
135.00°
C4
B1
3 4 5 6 7 8 9 10 11 1312
A
B
C
D
E
F
G
(e)
(e)
222A
222B
B
HALL
HALL
222-1
A
1'
- 0
2' - 0"
9'
8"
8' - 6 1/2" 8' - 6 1/2" 8' - 9 1/2" 5' - 9"
2'
7"
5' - 6"
OFFICE
222F
OFFICE
222G
AA
A
AA
2-
222F 222G
HALL
OPEN OFFICE
A
AA
HALL
JAN
AE402
D2
AE402
D2
AE402
A3
ASSEMBLY TYPE (SEE ASSEMBLIES SHEET)
ASSEMBLY MODIFIER, PER TYPE
ROOM NAME AND NUMBER
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DOOR NUMBER (SEE SHEET A601A)
DIMENSION TO FACE OF FRAMING
1-
XXX000
SIM
X
XX
NAME
X
PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
A.
B.
C.
D.
E.
F.
CONTRACTOR TO FIELD VERIFY ALL EXISTING
CONDITIONS
REFER TO CODE PLANS FOR LOCATIONS OF ANY
RATED DOORS AND ASSEMBLIES
FOR ANY WALLS NOT LABELLED, USE TYPE MOST
CONSISTENT WITH SIMILAR
APPLICATIONS/LOCATIONS.
ALL STUD WALLS TO HAVE 4" STUD RETURN AT
DOORS BETWEEN STUD OPENINGS TO
PERPENDICULAR WALL AT HINGE SIDE OF DOOR.
SEE AE001 FOR WALL TYPES AND NOTES.
SEE CIVIL, STRUCTURAL, FIRE PROTECTION,
PLUMBING, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL REQUIREMENTS.
GENERAL SHEET NOTES
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:2
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R P
LA
N
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AE401
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
14 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
A1 SECOND FLOOR PLAN
# SHEET KEYNOTES
0 4' 8' 16'
N
KEY PLAN
1 FIRE EXTINGUISHER CABINET.
2 WALL MOUNTED TELEVISION, OFOI. PROVIDE
BLOCKING IN WALL FOR INSTALLATION.
3 NEW SOLID SURFACE WINDOW SILL, SEE DETAIL
A1/AE501.
4 PROVIDE BLOCKING IN WALL FOR CABINETRY.
5 EXISTING COLUMN TO REMAIN, FINISH PER DETAIL
AND FINISH PLANS.
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
F
B.
C.
D.
E.
F.
CONTRACTOR TO FIELD VERIFY ALL EXISTING
CONDITIONS
REFER TO CODE PLANS FOR LOCATIONS OF ANY
RATED DOORS AND ASSEMBLIES
FOR ANY WALLS NOT LABELLED, USE TYPE MOST
CONSISTENT WITH SIMILAR
APPLICATIONS/LOCATIONS.
ALL STUD WALLS TO HAVE 4" STUD RETURN AT
DOORS BETWEEN STUD OPENINGS TO
PERPENDICULAR WALL AT HINGE SIDE OF DOOR.
SEE AE001 FOR WALL TYPES AND NOTES.
SEE CIVIL, STRUCTURAL, FIRE PROTECTION,
PLUMBING, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL REQUIREMENTS.
GENERAL SHEET NOTES
ASSEMBLY TYPE (SEE ASSEMBLIES SHEET)
ASSEMBLY MODIFIER, PER TYPE
ROOM NAME AND NUMBER
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DOOR NUMBER (SEE SHEET A601B)
DIMENSION TO FACE OF FRAMING
1-
XXX000
SIM
X
XX
NAME
X
PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
WOMEN
MEN
1' - 9"
8'
0"
1' - 9"
8'
0"
4 5
D
F
IN600B3
B2
A1
B4
IN600A5
A2
A3
A4
215 (e) 216 (e)
4' - 8"
5'
0" 2'
6"
4' - 8"
5'
0" 2'
6"
C4
AE501
EXISTING WALL
CONSTRUCTION
EXISTING EXHUAST DUCT
OPENING, DEMOLISH
DUCT AND VENT PER
MECHANICAL
STUD BLOCKING AS
REQUIRED TO SUPPORT
GYPSUM BOARD
5/8" TYPE 'X' GYP BOARD
TO COVER INTERIOR
SIDE OF OPENING.
FINISH TO MATCH
ADJACENT
RIGID INSULATION
TO INFILL OPENING,
ATTACHED TO CMU
EIFS, FINISH TO
MATCH ADJACENT
WALL
OPEN OFFICE
10 11 1312
I
J
K
L
PREDICTIVE
SERVICES
203C
PREDICTIVE
SERVICES
203B
ELEV.
VEST.
HALL
STAIR
#1
D1
AE402
EXISTING STEEL
STRUCTURAL COLUMN
CORNER BEAD AT ALL
CORNERS
5/8" TYPE 'X' GYPSUM
BOARD - ALL SIDES.
FINISH PER FINISH
PLANS
7/8" METAL HAT
CHANNELS - ALL SIDES
DRYWALL FRAMING
ANGLES AT CORNERS
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:2
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R P
LA
N
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AE402
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
15 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
# SHEET KEYNOTES
KEY PLAN
0 2' 4' 8'
N
1 NEW SOLID SURFACE WINDOW SILL, SEE DETAIL
A1/AE501.
D2 COLUMN WRAP
A1 ADD ALTERNATE FLOOR PLAN A3 SECOND FLOOR RESTROOM PLAN
D1 EIFS PATCH AT EXHAUST
0 4' 8' 16'
N
NOTE: ALL WORK IN THIS VIEW TO BE PART OF ADD ALTERNATE
0 0.5' 1' 2' 0 0.5' 1' 2'
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
OFFICE
222C
OFFICE
222D
OFFICE
222E
COMM
222A
ELEC
222B
BREAKROOM
AC1
8' - 6"
AC1
8' - 6"
AC1
8' - 6"
AC1
8' - 6"
AC1
8' - 6"
WOMEN
MEN
Q
3 4 5 6 7 8 9 10 11 1312
A
B
C
D
E
F
G
I
EX
8' - 4"
EX
8' - 4"
HALL
HALL
PREDICTIVE
SERVICES
203B
ELEV.
VEST.
OFFICE
222F
OFFICE
222G
AC1
8' - 6"
AC1
8' - 6"
HALL
AC1
8' - 6"
OPEN OFFICE
AC1
8' - 6"
FOCUS
AE421
A3
CEILING MATERIAL
CEILING HEIGHT
ADDITIONAL NOTES
ACT
2X4 ACOUSTICAL
LAY-IN CEILING
NOTES
ACT
0'-0 0/0"
REFLECTED CEILING LEGEND
LIGHTING -
SEE ELECTRICAL
HVAC
REGISTERS -
SEE
MECHANICAL
CEILING HEIGHT
VAR VARIES
ADDITIONAL NOTES
1. EXISTING CEILING. CUT AND PATCH AS NEEDED TO
ACCOMODATE NEW WORK. PROVIDE SUPPORT
WHERE CEILING IS CUT AS NEEDED.
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:3
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R R
EF
LE
C
TE
D C
EI
LI
N G
P
LA
N
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AE420
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
16 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
A1 SECOND FLOOR REFLECTED CEILING PLAN
0 4' 8' 16'
N
KEY PLAN
1 EXISTING CEILING TO REMAIN. REINSTALL ALL
CEILING GRID AND TILES REMOVED FOR DEMOLITION
OR CONSTRUCTION. REPLACE ANY CEILING GRID OR
TILES DAMAGED BY CONSTRUCTION ACTIVITIES.
2 TUBULAR DAYLIGHTING DEVICE. SEE DETAIL C3 FOR
MOUNTING TO EXISTING ROOF.
3 PROVIDE NEW CEILING GRID AND TILE IN THIS AREA,
CONTINUOUS WITH SURROUNDING EXISTING
CEILING. MATCH EXISTING CEILING HEIGHT.
# SHEET KEYNOTES
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
CEILING MATERIAL
CEILING HEIGHT
ADDITIONAL NOTES
ACT
2X4 ACOUSTICAL
LAY-IN CEILING
NOTES
ACT
0'-0 0/0"
REFLECTED CEILING LEGEND
LIGHTING -
SEE ELECTRICAL
HVAC
REGISTERS -
SEE
MECHANICAL
CEILING HEIGHT
VAR VARIES
ADDITIONAL NOTES
1. EXISTING CEILING. CUT AND PATCH AS NEEDED TO
ACCOMODATE NEW WORK. PROVIDE SUPPORT
WHERE CEILING IS CUT AS NEEDED.
WOMEN
MEN
EX
7' - 10"
EX
7' - 10"
4 5
D
F
1 1
OPEN OFFICE
9 10 11 12
I
J
K
AC1
9' - 0"
HALL
ELEV.
VEST.
201PREDICTIVE
SERVICES
203B
PREDICTIVE
SERVICES
203C
24 GAUGE
PREFINISHED
METAL DRIP EDGE
W/
FLUOROPOLYMER
FINISH
PREFABRICATED INSULATED
CURB. SECURE/FASTEN PER
MANUFACTURERS
RECOMMENDATIONS
FULLY ADHERED SINGLE-PLY
ROOF MEMBRANE EXTENDED
OVER ENTIRE CURB AND
DOWN INSIDE FACE 1"
NEOPRENE GASKET
(S
ET
L
EV
EL
8" M
IN
3" MIN. WIDE
SEAM TAPE
SEAM PLATE AND
FASTENER
SINGLE PLY ROOF
MEMBRANE TO
MATCH EXISTING
BONDING ADHESIVE
TUBULAR DAYLIGHTING
DEVICE - MOUNT AND
FLASH TO CURB
EXISTING ROOF
ASSEMBLY
ROOF WARRANTY NOTE:
EXISTING ROOFING SYSTEM WAS
INSTALLED IN 2020 AND IS UNDER AN
EXISTING MANUFACTURER WARRANTY.
CONTRACTOR TO COORDINATE WORK
WITH EXISTING ROOFING SYSTEM
MANUFACTURER AND PROVIDE A
CERTIFIED STATEMENT FROM THE
EXISTING ROOFING SYSTEM
MANUFACTURER STATING THAT
EXISTING ROOF WARRANTY HAS NOT
BEEN AFFECTED BY THIS WORK.
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:4
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
SE
C
O N
D F
LO
O
R R
EF
LE
C
TE
D C
EI
LI
N G
P
LA
N
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AE421
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
17 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
KEY PLAN
1 EXISTING CEILING TO REMAIN. REINSTALL ALL
CEILING GRID AND TILES REMOVED FOR DEMOLITION
OR CONSTRUCTION. REPLACE ANY CEILING GRID OR
TILES DAMAGED BY CONSTRUCTION ACTIVITIES.
2 PROVIDE NEW CEILING GRID AND TILE IN THIS AREA,
CONTINUOUS WITH SURROUNDING EXISTING
CEILING. MATCH EXISTING CEILING HEIGHT.
0 2' 4' 8'
N
C1 ROOF CURB AT TUBULAR DAYLIGHTING DEVICE
A1 ADD ALTERNATE REFLECTED CEILING PLAN A3 SECOND FLOOR REFLECTED CEILING PLAN
# SHEET KEYNOTES
0 4' 8' 16'
N
NOTE: ALL WORK IN THIS VIEW TO BE PART OF ADD ALTERNATE
0 0.125' 0.25' 0.5' 0.75'
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
TYP DIMENSION FROM
PERPENDICULAR WALL,
UNLESS DIMENSIONED
OTHERWISE
DOOR PER SCHEDULE
SILENCER OR GASKET
AS SCHEDULED
HM DOOR FRAME
METAL STUDS
SEALANT @ PERIMETER
BOTH SIDES TYP
0' - 4" 0' - 2"
INTERIOR FINISH PER
SCHEDULE
HM FRAME, FINISHED
AS SCHEDULED
SCHEDULED DOOR
SEALANT
PERIMETER
BOTH SIDES - TYP
SILENCER OR SOUND
GASKET PER
HARDWARE SCHEDULE
PROVIDE BOX HEADER
OR NESTED STUDS AT
DOOR HEADER
INTERIOR FINISH PER
SCHEDULE
0'
2"
INTERIOR
SEALANT
EXISTING
EXTERIOR
WALL
EXISTING ALUMINUM
FRAMED WINDOW
PROVIDE LAYER GLASS-
MAT FACED GYPSUM
SHEATHING EXTERIOR
1/2" SOLID SURFACE SS-2
WINDOW SILL W/ 1/16 R
EASED EDGES
1/
2"
MIN. 1/8" GAP
1/2"
HM FRAME, FINISHED
AS SCHEDULED
GLAZING BEAD
SEALANT
PERIMETER
BOTH SIDES - TYP
GLAZING
PROVIDE BOX HEADER
OR NESTED STUDS AT
DOOR HEADER
INTERIOR FINISH PER
SCHEDULE
0'
2"
GLAZING BEAD
GLAZING
HM DOOR FRAME
METAL STUDS
SEALANT @ PERIMETER
BOTH SIDES TYP
0' - 2"
INTERIOR FINISH PER
SCHEDULE
GLAZING BEAD
GLAZING
HM DOOR FRAME
EXISTING CONCRETE
FLOOR SLAB
SEALANT AT
PERIMETER - BOTH
SIDES TYP
INTERIOR FLOOR FINISH
PER SCHEDULE - BOTH
SIDES
REFERENCE ELEVATIONS AND
MATERIALS LIST FOR FINISHES
SCHEDULED BASE
SOLID SURFACE
COUNTER WITH
APRON
UNO
1' - 9"
" M
AX
" M
IN
UNDERLAVATORY
GUARD AT EXPOSED
PIPES
FINISH WALL WHERE
EXPOSED
6" MAX
0'
7"
0'
4"
HEAVY DUTY STEEL
COUNTERTOP
BRACKET
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:4
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
D O
O R
D
ET
AI
LS
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AE501
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
18 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
D1 TYP. INTERIOR HM DOOR JAMB D2 TYP. INTERIOR HM DOOR HEAD
A1 SOLID SURFACE WINDOW SILL
0 0.125' 0.25' 0.5' 0.75' 0 0.125' 0.25' 0.5' 0.75'
0 0.125' 0.25' 0.5' 0.75'
B2 TYP. INTERIOR HM TRANSOM/SIDELITE HEADB1 TYP. INTERIOR HM TRANSOM/SIDELITE JAMB 0 0.125' 0.25' 0.5' 0.75' 0 0.125' 0.25' 0.5' 0.75'
A2 TYP. INTERIOR HM SIDELITE SILL
0 0.125' 0.25' 0.5' 0.75'
C4 SINK W/ SOLID SURFACE APRON
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
DOOR TYPES
F.F.
F
HOLLOW METAL FRAME TYPES
AS
S
C H
ED
U
LE
D
0'
2"
VL
2'
0'
6"
0' - 8" 0' - 4"
AS SCHED. 0' - 2" 0' - 2"
SCHED.
AS
AT MTL
STUD
AS
S
C H
ED
U
LE
D
AS SCHED.
AS
S
C H
ED
U
LE
D
0'
2"
0' - 2" 0' - 2"
SCHED.
AS
AT MTL
STUD
1' - 2" 0' - 2"
AS
S
C H
ED
U
LE
D
0'
2"
0' - 2" 0' - 2"
SCHED.
AS
1'
0"
AT MTL
STUD
T T
T
T
FF FACTORY FINISH
HM HOLLOW METAL
PT PAINT
ST STEEL
T 1/4" TEMPERED GLAZING (MONOLITHIC)
WD SOLID CORE WOOD
VL VISION LITE
ABBREVIATIONS
DOOR NOTES
FRAME NOTES
T TEMPERED GLAZING
GLAZING TYPES
1. PAINT EXISTING FRAME 'P2'.
1. INSTALL DOOR STOP 6" MINIMUM FROM LATCH SIDE OF
DOOR FOR GOVERNMENT INSTALLATION OF
ANCHORMAN DOOR BARRICADE DEVICE.
A.
B.
C.
D.
E.
SEE FLOOR PLANS FOR DOOR AND FRAME LOCATIONS.
FIELD VERIFY ALL ROUGH OPENING DIMENSIONS PRIOR
TO FABRICATION/ INSTALLATION.
PROVIDE ONE ELECTRICAL CONDUIT RUN FROM DOOR
STRIKE TO ABOVE ADJACENT CEILING SPACE AS NEEDED
FOR DOORS TO RECEIVE ELECTRIC HARDWARE.
SEAL ALL PENETRATIONS IN ALL STC RATED WALLS WITH
ACOUSTICAL SEALANT. SEE AE001 FOR STC WALLS.
PAINT ALL NEW HOLLOW METAL FRAMES 'P2'.
GENERAL NOTES
DOOR HARDWARE
GROUP 1 - OFFICES
GROUP 3 - CONFERENCE/SHARED USE SPACES
OFFICE LOCKSET W/ INTERIOR TURN-BUTTON
HINGES
DOOR STOP/ HOLD-OPEN
DOOR SILENCERS
OFFICE LOCKSET W/ INTERIOR TURN-BUTTON
HINGES
DOOR STOP/ HOLD-OPEN
DOOR SILENCERS
GROUP 2 - OFFICES W/ SECURITY
ELECTROMECHANICAL MORTISE LOCKSET
HINGES
ELECTRIFIED HINGE
CLOSER HOLDER RELEASE DEVICE
DOOR STOP
DOOR POSITION SWITCH
CARD READER
DOOR SILENCERS
GASKETING
DOOR SWEEP
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:5
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
D O
O R
S C
H
ED
U
LE
A N
D
EL
EV
AT
IO
N
S
M O
R
TE
N
SO
N
M
AC
KE
N
ZI
E
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-J
W H
S U
IT
E
2/
R
EN
O
VA
TI
O
N S
D ev el op m en t A ve
, B oi se , I
D
8)
-5
140L062F0116
070117.029
05/08/2026
AE601
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
19 86
0%
IS
SU
ED
F O
R C
O N
ST
R
U C
TI
O
N
DOOR, FRAME AND HARDWARE SCHEDULE
DOOR
NUMBER
ROOM
NUMBER ROOM NAME
DOOR FRAME
FIRE
RATING HARDWARE
GROUP
SIZE
MTL TYPE GLAZE NOTES MTL TYPE
DETAIL
NOTES
W H T HEAD JAMB SILL
220 220 FOCUS 3' - 0" 7' - 0" 0' - 1 3/4" WD VL T 1 HM 1 D2/AE501 D1/AE501 - - -- 3
222-1 222 OPEN OFFICE 3' - 0" 7' - 0" 0' - 1 3/4" WD VL T 1 HM 2 B2&D2/AE501 B1&D1/AE501 A2/AE501 - - 2 222-2 222 OPEN OFFICE 3' - 0" 7' - 0" 0' - 1 3/4" WD VL T 1 HM 2 B2&D2/AE501 B1&D1/AE501 A2/AE501 - - 2 222C 222C OFFICE 3' - 0" 7' - 0" 0' - 1 3/4" WD VL T - HM 3 B2&D2/AE501 B1&D1/AE501 - - - 1 222D 222D OFFICE 3' - 0" 7' - 0" 0' - 1 3/4" WD VL T - HM 3 B2&D2/AE501 B1&D1/AE501 - - - 1 222E 222E OFFICE 3' - 0" 7' - 0" 0' - 1 3/4" WD VL T - HM 3 B2&D2/AE501 B1&D1/AE501 - - - 1 222F 222F OFFICE 3' - 0" 7' - 0" 0' - 1 3/4" WD VL T - HM 3 B2&D2/AE501 B1&D1/AE501 - - - 1 222G 222G OFFICE 3' - 0" 7' - 0" 0' - 1 3/4" WD VL T - HM 3 B2&D2/AE501 B1&D1/AE501 - - - 1 224 224 BREAKROOM 3' - 0" 7' - 0" 0' - 1 3/4" WD VL T - HM 2 B2&D2/AE501 B1&D1/AE501 A2/AE501 - - 3
DOOR, FRAME AND HARDWARE SCHEDULE - EXISTING
DOOR
NUMBER
ROOM
NUMBER ROOM NAME
DOOR FRAME
FIRE
RATING HARDWARE
GROUP
SIZE
MTL TYPE GLAZE NOTES MTL TYPE
DETAIL
NOTES
W H T HEAD JAMB SILL
222A 222A COMM 3' - 0" 7' - 0" 0' - 1 3/4" WD EX - - HM EX - - - 1 -- -
222B 222B ELEC 3' - 0" 7' - 0" 0' - 1 3/4" WD EX - - HM EX - - - 1 -- -
De sc rip tio n
Da te
0%
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
XX###
XX###
XX###
XX###
OFFICE
222C
OFFICE
222D
OFFICE
222E
OPEN OFFICE
COMM
222A
ELEC
222B
BREAKROOM
CG1
CG1
CG1
HALL
HALL
HALL
OPEN OFFICE
OFFICE
222F
OFFICE
222G
FOCUS
MEN
WOMEN
HALL
HALL
STAIR
#2
STAIR
#1
PREDICTIVE SERVICES
203C
OPEN OFFICE
VEST.
ELEV.
PREDICTIVE SERVICES
203B
DISPATCH
IN401
A1
IN402
A1
IN402
A3
GENERAL FINISH NOTES
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION.
ALL PRODUCTS ARE TO BE INSTALLED PER MANUFACTURER'S
INSTRUCTIONS, USING MANUFACTURER'S ADHESIVES, TOOLS, AND
METHODS.
COORDINATE ALL OWNER FURNISHED EQUIPMENT, ACCESSORIES, AND
FURNITURE WITH OWNER AND/OR OWNER ’S VENDOR.
ALL FLOOR TRANSITIONS ARE TO OCCUR DIRECTLY BENEATH DOORS,
ALIGNED WITH CORNERS OR CENTERED IN OPENING UNLESS NOTED
OTHERWISE.
ALL FLOOR TRANSITIONS ARE TO BE ABA COMPLIANT.
PREP FLOOR AS REQUIRED FOR NEW FLOOR FINISHES PRIOR TO
INSTALLATION, INCLUDING FLOOR LEVELER.
PROVIDE STAINLESS STEEL TRANSITION STRIPS/REDUCERS AT ALL
LOCATIONS WHERE CERAMIC TILE MEETS A DIFFERENT FLOOR
MATERIAL. PROVIDE RUBBER TRANSITION STRIPS/REDUCERS AT ALL
OTHER LOCATIONS BETWEEN DIFFERING FLOOR MATERIALS.
WALL TILE TO HAVE SCHLUTER TRIM AT EXPOSED EDGES. REFER TO
ELEVATIONS FOR TILE PATTERNS.
REFER TO FINISH PLAN FOR LOCATION OF CORNER GUARDS. ALL
CORNER GUARDS ARE TO BE INSTALLED WITH BOTTOM OF
CORNERGUARD AT TOP OF WALL BASE.
ALL GYPSUM WALLS TO BE PAINTED ‘P1’ UNLESS OTHERWISE NOTED.
ALL NEW GYPSUM WALLS TO BE FINISHED AND TEXTURED TO MATCH
EXISTING. SEE SPECS. REFERENCE FINISH PLAN FOR OTHER FINISHES.
EXISTING WALLS IN AREAS NOTED OUTSIDE OF SCOPE TO REMAIN AS-
IS. EXISTING WALLS IN SCOPE TO BE FINISHED SIMILAR TO NEW
WALLS.
ALL GYPSUM CEILINGS AND SOFFITS TO BE PAINTED 'PC1' UNLESS
OTHERWISE NOTED ON REFLECTED CEILING PLAN.
ALL CEILINGS OPEN TO STRUCTURE (OTS) TO BE PAINTED 'PT1' UNLESS
OTHERWISE NOTED ON REFLECTED CEILING PLAN. INCLUDE ALL
EXPOSED STRUCTURAL AND MECHANICAL COMPONENTS, ELECTRICAL
CONDUIT, ETC.
ALL HOLLOW METAL FRAMES TO BE PAINTED 'P2' UNLESS OTHERWISE
NOTED.
ALL METAL ACCESS PANELS, COVER PLATES, VENTS, AND GRILLES TO
BE PAINTED TO MATCH THE SURFACE IT IS LOCATED ON.
ALL SOLID SURFACE COUNTERTOPS ARE TO BE ‘SS1’ AND HAVE EASED
EDGES. ADJACENT SOLID SURFACE BACKSPLASHES TO MATCH.
ALL WINDOW TREATMENTS ARE TO BE FIELD MEASURED, INSTALLED
WITH ALL COMPONENTS, AND INSIDE MOUNTED AND WITH VALANCES
UNO. CONTRACTOR TO PROVIDE BLOCKING.
EXTENT OF ACCENT PAINT OR WALL FINISHES
LOCATION AND TYPE OF CORNER GUARDS#
FINISH PLAN LEGEND
ROOM NAME AND NUMBER
FINISH TAG
A8## # INTERIOR ELEVATION CALLOUT AND
DIRECTION OF ELEVATION VIEW
NAME
FINISH TAGS DISPLAYED IN GROUPING ON FINISH PLAN
REPRESENT MAJORITY ROOM FINISH SELECTIONS.
ORDER OF GROUPING DEFINED IN EXAMPLE BELOW:
MAJORITY WALL FINISH
MAJORITY BASE FINISH
MAJORITY FLOOR FINISH
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
5/ 8/
1:
:5
AM
U :\t yl er m or te ns on \D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ ty le rm or te ns on
.rv t
FI
N
IS
H
F
LO
O R
O
VE
R
AL
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .