Atch 4_Phase 2 Final Const Dwgs.pdf
PDF 1 MB Posted
- Attached to
- Roof replacement with heat trace, Pocatello
- Solicitation number
- 12639525R0021
About this file
These are design and contract documents for a roof replacement project for the U.S. Department of Agriculture (USDA) Animal and Plant Health Inspection Service (APHIS) located at 238 East Dillon St. in Pocatello, Idaho. The project involves replacing roofing in Roof Areas A, D, and E, with a base bid that includes removing existing roofing materials (including some asbestos-containing materials), installing new roofing systems, and adding new components such as gutters, downspouts, heat trace, and flashing. Roof Area A will receive a single-ply membrane system, while Roof Areas D and E will get new asphalt shingles, underlayment, ice and water shield, and two new Kalwall systems. The project also includes electrical work for heat trace installation with thermostat control, and is designed to meet specific wind uplift and building code requirements. The documents are dated November 22, 2024, and were prepared by Cushing Terrell architectural firm, with the project using standard roofing best practices and following national roofing and building code standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| PSD Roof Phase 2 Site Visit Sign In Sheet.pdf | ||
| Atch 2_Federal Construction Wage Rates_Bannock County.pdf | ||
| Atch 3_Project Manual.pdf | ||
| Atch 1_SOW_PSD roof replacement phase 2.doc | DOC document | |
| 12639525R0021.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWN BY |
REVISIONS
© | ALL RIGHTS RESERVED
CHECKED BY |
PROJECT #|
R oo f R ep la ce m en t P ha se
(A re as A
,D
E
P oc at el lo , I
D
EA
ST
D
IL
LO
N S
T.
U
.S . D
EP
AR
TM
EN
T O
F
AG
R
IC
U
LT
U R
E
AP
H
IS
CONTRACT DOCUMENTS
11.22.2024
USDA_REROOF1
November 22, 2024
VICINITY MAP: Locator
OWNER SHEET INDEX
GENERAL
G001 COVER SHEET
A101 EXISTING/NEW ROOF CONSTRUCTION, GENERAL NOTES, WIND UPLIFT DIAGRAM, & PARTIAL ROOF PLANS
A102 ROOFING DETAILS
A103 ROOFING DETAILS
A104 ROOFING DETAILS
ELECTRICAL
E101 ELECTRICAL ROOF PLAN - PHASE 2
06.29.17 11:09 PM | L:\USDAPSD_REROOF1\Phase 2 re-roof dwgs\Arch\USSD_G001.dwg G001
COVER SHEET
KEELER
ROBERTS
PROJECT ADDRESS
U.S. Department of Agriculture (USDA), Animal and Plant Health Inspection Service ( APHIS) Pocatello Supply Depot 238 E. Dillon Street, Pocatello, Idaho 83201.
U.S. DEPARTMENT OF AGRICULTURE APHIS
Roof Replacement Phase 2 (Areas A, D, & E) - Pocatello, ID
PROJECT SUMMARY
USDA, APHIS, MRPBS, AAMD
250 Marquette Avenue, Suit 410 Minneapolis, MN 55401 - 2329 Email: James.G.Roloff@usda.gov
ARCHITECT/ENGINEER
CUSHING TERRELL
800 W Main St, Suite 800 Boise, ID 83702 208.577.5629 Email: ScottRoberts@cushingterrell.com
The Facility was constructed in the early 1930's. The original roof was replaced over 20 years ago. The facility underwent a small section of roofing alterations and patching during the replacement of the rooftop HVAC equipment in 2017.
USDA is seeking to remove and replace the existing roof which is comprised of a combination of asphalt shingles, modified bitumen and single-ply membrane.
NORTH
REF.
NAME:
DATE:
ARCHITECTURAL/ROOFING
Scott Roberts 11/22/2024
6" RP
RD
RH
99"
33"
RP 12"Ø
RP 18"Ø
RP 20"Ø
RP 48"Ø
RP 48"Ø RP 10"Ø
RP 12"Ø
V 4"Ø
RP 29"Ø
RP 29"Ø
RP 29"Ø
METAL ROOF
5" DS
RTU UNIT
ABOVE 27"
60"
10" RP
10" RP
10" RP
10" RP
EC
EC
60"
27"
ABANDONED PIPES
6"X6" GUTTER
STEPPED
PARAPET6" BV
6" BV
6" RV6" RV
6" RV6" RV
6" BV
RL
HIGHLOW
HIGH
LOW
HIGH LOW
5" DS
17" 19"
4"X4" GUTTER
6"X6" GUTTER
GUTTER
WOOD POLE
4" RV
4" RV
4" RV4" RV
GNV
2" VTR
4" VTR
6" RV
VTR
VTR
4"X4" GUTTER
3" DS
DS DS
VTR
EF
EF
CU
SLOPESLOPE
SL
O
PE
SL
O
PE
HIGH
LOW
HIGH LOW
(4)WH
EF
VTR
6" RV
6" RV
2" GP
24"X
24"X
10" RP
6" RV
4" RV
4" RV
1" EC
8" RV
6" RV
TYPICAL OF (8) EA SIDE OF SKYLIGHTS
WOOD POLE
MV
MV
MV
6"X6" GUTTER
A102
A102
ROOF AREA D
5886 SQ FT +-
ROOF AREA A
812 SQ FT +-
A101
A102
VENTED RIDGE
VE
N
TE
D
R
ID
G E
A102
A102
EXISTING BUILDING
A102
A103
TYPICAL
A104
TYPICAL
A103
A
A103
ROOF AREA E
12,552 SQ FT +-
A102
A102
A102
A103
A103
A102 SIM
A104
5 B
5 B
NIC
NIC
ROOF AREA F
A102
RD
RH
99"
33"
RP 12"Ø
RP 18"Ø
RP 20"Ø
RP 48"Ø
RP 48"Ø
RP 10"Ø
RP 12"Ø
V 4"Ø
RP 29"Ø
RP 29"Ø
RP 29"Ø
6" BV
6" BV
HIGHLOW
HIGH
LOW
HIGH LOW
4"X4" GUTTER
4"X4" GUTTER
A102
HIGH
TYPICAL ALL (4)
SIDES
A103
A103
A103
SLOPE
A102
AT EXISTING
CHIMNEY
A103
P1C
NO SCALE
KEYPLAN
ROOF AREA A
ROOF AREA E
ROOF AREA D
NIC
ROOF AREA F
GENERAL ROOFING NOTES
1. THE FOLLOWING REFERENCES HAVE BEEN USE AS A BASIS FOR DESIGN OF
THE ROOFING RELATED WORK OF THE PROJECT AND SHALL BE USED BY THE
CONTRACTOR TO DETERMINE REQUIREMENTS FOR FABRICATION AND/OR
INSTALLATION WHEN NOT SPECIFICALLY INDICATED IN THE CONTRACT
DOCUMENTS.
A. NATIONAL ROOFING CONTRACTORS ASSOCIATION (NRCA) "ROOFING AND
WATER PROOFING MANUAL, FIFTH EDITION".
B. SHEET METAL AND AIR CONDITIONING NATIONAL CONTRACTORS
ASSOCIATION (SMACNA) - "ARCHITECTURAL SHEET METAL MANUAL, FIFTH
EDITION".
C. 2021 INTERNATIONAL BUILDING CODE.
D. 2021 UNIFORM PLUMBING CODE.
E. AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) - SEI/ASCE 7-16:
"MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES"
(REVISION OF SEI/ ASCE 7-10).
F. MATERIAL MANUFACTURERS MOST RECENT PRINTED SPECIFICATIONS
AND INSTALLATION DETAILS.
2. PRIOR TO THE START OF WORK THE CONTRACTOR SHALL PROVIDE AND
INSTALL PROTECTION OVER, UNDER AND/OR AROUND ALL EXISTING SERVICES
LINES, BUILDING COMPONENTS, SIDEWALKS, PAVEMENT AND LANDSCAPING
WHICH COULD BE DAMAGED OR SOILED WHILE PERFORMING WORK OF THE
CONTRACT.
3. DETAILS IN THE PROJECT DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS
AND ARE INTENDED TO SHOW GENERAL REQUIREMENTS THROUGHOUT:
A. DETAILS NOTED ARE "TYPICAL" AND IMPLY ALL SIMILAR CONDITIONS
TREATED SIMILARLY. MODIFICATIONS TO MADE BY THE CONTRACTOR TO
ACCOMMODATE MINOR VARIATIONS WITHOUT ADDITIONAL COST TO THE
OWNER.
4. IN NO CASE SHALL CONSTRUCTION RELATED WORK BE DONE, OVER, OR
CONSTRUCTION RELATED TRAFFIC BE ROUTED OVER FINISHED ROOF AREAS
WITHOUT PROTECTION BEING PLACED OVER ROOF MEMBRANE. PROTECTION
SHALL CONSIST OF THE FOLLOWING (BOTTOM TO TOP).
A. 1-INCH EXPANDED POLYSTYRENE
B. 10-MIL POLYETHYLENE
C. 1/2" PLYWOOD
D. WEIGH DOWN ALL PROTECTION MATERIALS TO PREVENT DISPLACEMENT
BY WIND.
NOTE: ROOF AREAS THAT HAVE NOT BEEN PROTECTED FROM CONSTRUCTION
RELATED TRAFFIC AS SPECIFIED ABOVE SHALL BE REMOVED AND REPLACED
AT NO ADDITIONAL COST TO THE OWNER.
5. PROVIDE CRICKETS ON THE UP SLOPE SIDE OF ALL ROOF CURBS AS
REQUIRED FOR DRAINAGE.
6. FIELD VERIFY ALL DIMENSIONS.
RD NEW ROOF DRAIN AT EXISTING LOCATION W/ 8'-0"x8'-0"
SUMP - REFER TO DETAIL 10/A103
VTR PLUMBING VENT THRU ROOF - CONTRACTOR TO FIELD VERIFY
QUANTITIES & SIZES. FLASH PER DETAILS 4/A103, & 5/A103
EXHAUST FAN (ELEC. OR SERVICEABLE) - REFER TO DETAILS 2/A104
RH ROOF HATCH(NOT TO SCALE) - FLASH PER DETAIL 9/A103
RTU
EC ELECTRICAL CONDUIT - REFER TO DETAILS 4/A103, 5/A103, & 8/A103
ROOFTOP UNIT ON RAILS ABOVE ROOF (NOT TO SCALE)
ROOF ACCESS LADDER (EXISTING)
SLOPE
P#
ROOF PLAN NOTE
ROOF PLAN PLUMBING NOTE
EF
B VENT THRU ROOF - FLASH PER DETAIL 1/A103
SP EQUIPMENT SERVICE LINE PENETRATION - REFER TO DETAILS 4/A103,
5/A103, & 8/A103
MASONRY CHIMNEY - REFER TO DETAIL 8/A102
DIRECTION OF FINISHED ROOF SLOPE FROM TAPERED INSULATION /
CRICKETS
DIRECTION OF FINISHED ROOF SLOPE FROM SLOPING STRUCTURE
ROOF SLOPE VALLEY LINE
GOOSE NECK VENT - REFER TO DETAIL 2/A104 FOR SIMILIARGNV
ROOF AREA "_"
### SF ROOF AREA DESIGNATION TAG: SQUARE FOOTAGE IS APPROXIMATE -
CONTRACTOR TO FIELD VERIFY
RP ROUND PIPE OR ROOF VENT THRU ROOF - SIZES VARY, FIELD VERIFY.
REFER TO DETAILS 4/A103, 5/A103, & 8/A103
TAPERED INSULATION/CRICKET
(light shade)
PARAPET/ROOF TO WALL (NOTE)
ROOF EDGE
RL
GUTTER
GUTTER W/ DOWNSPOUT - REFER TO ROOF PLAN FOR LOCATIONS &
SIZES. REFER TO DETAILS 4/A104 & 5/A104
WH WEATHERHEAD (EXISTING)
RV or
MV METAL VENT - REFER TO DETAIL 1/A104
BV
8'-0"
8' -0
SYMBOL LEGEND
GP GAS PIPE THRU ROOF - REFER TO DETAILS 4/A103, 5/A103, & 8/A103
DS
? ROOF PLAN DEMOLITION NOTE
A101
ROOF AREAS D & E
EXISTING ROOF CONSTRUCTION
SCALE: 1-1/2"=1'-0"
EXISTING WOOD ROOF DECK:
STRUCTURALLY SLOPED - TO
REMAIN
VAPOR RETARDER: TO REMAIN
INSULATION: TO REMAIN
3/4" SHEATHING: TO REMAIN
3-1/2" AIR GAP
5/8" SHEATHING: TO REMAIN
30# BUILDING PAPER: REMOVE
ASPHALT SHINGLES: REMOVE
A101
ROOF AREA A
EXISTING ROOF CONSTRUCTION -
SCALE: 1-1/2"=1'-0"
A101
ROOF AREA(S): D & E
NEW ROOF CONSTRUCTION
SCALE: 1-1/2"=1'-0"
EXISTING WOOD ROOF DECK:
STRUCTURALLY SLOPED - TO
REMAIN
VAPOR RETARDER: TO REMAIN
INSULATION: TO REMAIN
3/4" SHEATHING: TO REMAIN
3-1/2" AIR GAP
5/8" SHEATHING: TO REMAIN
UNDERLAYMENT
ASPHALT SHINGLES
COVER BOARD: 1" WOOD FIBER BOARD -
REMOVE
B.U.R. (BUILT-UP ROOFING): REMOVE
EXISTING T&G WOOD ROOF
DECK: STRUCTURALLY SLOPED -
TO REMAIN
MEMBRANE: HYPALON - REMOVE
NOTE: THERE IS ICE & WATER SHIELD AT THE
VALLEYS, RIDGES, EAVES, & RISING WALLS.
COVER BOARD: 1/2" HD BOARD OR
APPROVED EQUAL - FULLY ADHERE
A101
ROOF AREA A
NEW ROOF CONSTRUCTION
SCALE: 1-1/2"=1'-0"
MEMBRANE: THERMOPLASTIC -
FULLY ADHERED
TEMPORARY ROOF/AIR BARRIER: 10 MIL
POLYETHYLENE, LOOSE LAID - SEAL ALL
LAPS, PENETRATIONS, & TERMINATIONS
AIR/VAPOR TIGHT
INSULATION: (1) LAYER 3"
POLYISOCYANUATE - MECHANICALLY
ATTACHED
INSULATION: (1) LAYER 2-1/2"
POLYISOCYANUATE - FULLY ADHERE
ASBESTOS CONTAINING MATERIAL (ACM): 3% CHRYSOTILE IN
THE SILVER COATING & 15% CHRYSOTILE IN THE FELTS
EXISTING T&G WOOD ROOF
DECK: STRUCTURALLY SLOPED
ROOFING - WINDUPLIFT FORCES
FIELD UPLIFT FORCE:
DESIGN REQUIREMENTS PER SEI/ASCE 7-16
BASIC WIND SPEED:
BUILDING EXPOSURE:
RISK CATEGORY:
115 MPH (3-SEC. GUST)
B
IV
NOTE(S):
1. CALCULATED UPLIFT FORCES ARE FOR DESIGN OF ATTACHMENT OF
ROOFING COMPONENTS TO STRUCTURAL SUBSTRATES.
2. DIMENSIONS SHOWN ON WIND UPLIFT DIAGRAM ARE ROUNDED UP TO
NEAREST WHOLE FOOT.
3. UPLIFT FORCES INDICATED ARE FACTORED PER ALLOWABLE STRESS
DESIGN ASCE/SEI 7-16.
ROOF SECTION
A
NOT APPLICABLE
CORNER UPLIFT FORCE:
PERIMETER UPLIFT FORCE: NOT APPLICABLE
107 (LBF/SF)
EXTEND DOWNSPOUT SO WATER EXITS OUT
PAST THE CORNER OF THE BUILDING.
PROVIDE COVER BOARD AND MEMBRANE
OVER EXISTING ROOF DECK IN VALLEY AREA.
FIELD VERIFY DIMENSIONS & COVER INSIDE
FACE OF EXISTING PARAPET WITH
PREFINISHED 24 GAUGE GALVANIZED STEEL.
COLOR TO MATCH METAL COPING CAPS.
PATCH/REPAIR AND/OR REDECK EXISTING
ROOF DECK AT ABANDONED PIPE LOCATIONS.
REPLACE EXISTING ROOF DRAIN. REFER TO
DETAIL 10/A103.
P1
ROOF PLAN NOTE(S)
ROOF PLAN PLUMBING NOTE(S)
PROVIDE AND INSTALL NEW KALWALL
ASSEMBLY.
6 PROVIDE AND INSTALL NEW 4" GUTTER AND
DOWNSPOUT.
WIND UPLIFT DIAGRAM
NO SCALE
ROOF AREA A
A DEMOLISH EXISTING ABANDONED PIPES (CAPPED
OFF) & ASSOCIATE PARTS. TYPICAL OF (6).
B
C COORDINATE W/ PLUMBING CONTRACTOR AND
REMOVE/REPLACE EXISTING ROOF DRAIN.
ROOF PLAN DEMOLITION NOTE(S)
DEMOLISH EXISTING KALWALL ASSEMBLY.
ABBREVIATED SUMMARY OF WORK:
WITHOUT FORCE OR EFFECT ON THE CONTRACT DOCUMENTS, THE
FOLLOWING ABBREVIATED SUMMARY OF WORK OUTLINES THE WORK
INDICATED IN THE CONTRACT DOCUMENTS.
BASE BID: ROOF AREA A
1. REMOVE AND DISPOSE OF EXISTING ROOF MEMBRANE ASSEMBLIES
AND ASSOCIATED FLASHING(S) DOWN TO STRUCTURAL ROOF DECK
AND PERIMETER SUBSTRATES.
a. ASBESTOS CONTAINING MATERIAL (ACM): 3%
CHRYSOTILE IN THE SILVER COATING & 15% CHRYSOTILE
IN THE FELTS AT ROOF AREA A.
2. REMOVE AND DISPOSE OF EXISTING ROOFING RELATED SHEET
METAL FLASHING AND TRIM.
3. PROVIDE NEW INSERT DRAIN AT EXISTING ROOF DRAIN LOCATION.
4. PROVIDE WOOD BLOCKING/SHIMS AS INDICATED IN DRAWINGS.
5. PROVIDE AIR BARRIER, FLAT STOCK INSULATION, COVER BOARD,
SINGLE-PLY MEMBRANE AND ASSOCIATED FLASHINGS AS
INDICATED.
6. PROVIDE SHEET METAL FLASHINGS AS INDICATED TO FORM
COMPLETE SYSTEM.
7. PROVIDE EDGE METAL WHERE INDICATED IN THE DRAWINGS.
8. PROVIDE AND INSTALL NEW GUTTERS, DOWNSPOUTS, AND HEAT
TRACE.
BASE BID: ROOF AREAS D & E
1. REMOVE EXISTING ASPHALT SHINGLE ROOFING SYSTEM DOWN TO
EXISTING PLYWOOD SUBSTRATE.
a. ASBESTOS CONTAINING MATERIAL (ACM): 3%
CHRYSOTILE HAS BEEN FOUND IN THE SKYLIGHT GREY
CAULKING.
2. REMOVE AND DISPOSE OF EXISTING ROOFING RELATED SHEET
METAL FLASHING AND TRIM.
3. PROVIDE AND INSTALL NEW COVER BOARD AND MEMBRANE AT ALL
VALLEYS.
4. PROVIDE AND INSTALL NEW UNDERLAYMENT.
5. PROVIDE AND INSTALL NEW ICE AND WATER SHIELD AT RIDGES, HIP,
VALLEYS AND EAVES.
6. PROVIDE AND INSTALL NEW ASPHALT SHINGLES PER THE
SPECIFICATIONS.
7. PROVIDE AND INSTALL NEW EDGE METAL, METAL COPINGS AND
FLASHINGS WHERE INDICATED.
8. PROVIDE AND INSTALL NEW GUTTERS, DOWNSPOUTS, AND HEAT
TRACE.
9. PROVIDE AND INSTALL (2) NEW KALWALL SYSTEMS IN ROOF AREA D.
BASE BID: ROOF AREA F (NO ROOFING WORK)
1. PROVIDE AND INSTALL NEW 4" GUTTER, 3" DOWNSPOUT, AND HEAT
TRACE. REFER TO ELECTRICAL SHEET
DRAWN BY |
REVISIONS
© | ALL RIGHTS RESERVED
CHECKED BY |
PROJECT #|
R oo f R ep la ce m en t P ha se
(A re as A
,D
E
P oc at el lo , I
D
EA
ST
D
IL
LO
N S
T.
U
.S . D
EP
AR
TM
EN
T O
F
AG
R
IC
U
LT
U R
E
AP
H
IS
CONTRACT DOCUMENTS
11.22.2024
USDA_REROOF1
A101
ROOF PLAN
SCALE: 1/16"=1'-0"
A101
ROOF AREA A
PARTIAL ROOF PLAN -
SCALE: 1/8"=1'-0"
06.29.17 11:09 PM | L:\USDAPSD_REROOF1\Phase 2 re-roof dwgs\Arch\USSD_A101.dwg A101
EXISTING/NEW ROOF
CONSTRUCTION, GENERAL
NOTES, WINDUPLIFT
DIAGRAM, OVERALL ROOF
PLAN, & PARTIAL ROOF
PLANS
KEELER
ROBERTS
patt Text Box 11/ A103 patt Line patt Cloud patt Text Box 11/A103 patt Line patt Cloud
EDGE METAL - SECURE 8" O.C. W/
#8 GALVANIZED STEEL THREADED
FASTENERS (TYPICAL)
FASCIA METAL - SECURE 8" O.C.
W/ #8 GALVANIZED STEEL
THREADED FASTENERS (TYPICAL)
CONTINUOUS CLEAT -
SECURE 8" O.C. W/ #8 "WAFER HEAD"
GALVANIZED STEEL THREADED
FASTENERS (TYPICAL)
CONTINUOUS CLEAT
SET IN FULL BED OF NON CURING
SEALANT (TYPICAL)
5/8" HEM (TYPICAL)
AT DETAIL 5/A102
A102
METAL DETAILS
SCALE: 3"=1'-0"
PRE MANUFACTURED
RIDGE VENT - REFER TO
SPECIFICATIONS FOR TYPE
SHINGLE OVER
ASPHALT SHINGLE W/ ICE &
WATER SHIELD AND
UNDERLAYMENT UNDEREXISTING 2X BLOCKING
ICE & WATER SHIELD OVER FULL
FACE OF BLOCKING
METAL CLOSURE - REFER TO
DETAIL 2/A102
EXISTING SOFFIT ASSEMBLY
EDGE METAL - STRIP IN W/
ICE & WATER SHIELD. REFER
TO DETAIL 2/A102
A102
EAVE DETAIL
ROOF AREAS D & E SCALE: 3"=1'-0"
6"
1 2" 15 8"
A102
EDGE METAL AND METAL CLOSURE DETAIL
ROOF AREAS D & E SCALE: 3"=1'-0"
4" TYPICAL
A102
PREMANUFACTURED RIDGE VENT - TYPICAL
ROOF AREAS D & E SCALE: 3"=1'-0"
EXISTING WOOD ROOF DECK
UNDERLAYMENT
ASHPALT SHINGLES
ICE & WATER SHIELD AT ALL EAVES
ICE & WATER SHIELD AT ALL
RIDGES (TYPICAL)
A101
1" HEM
5/8" HEM3"
4"
METAL CLOSURE -
PREFINISHED 24 GAUGE
GALVANIZED STEEL. SECURE 8"
O.C. W/ #8 GALVANIZED
THREADED FASTENERS
EDGE METAL - PREFINISHED 24
GAUGE GALVANIZED STEEL.
SECURE 8" O.C. W/ #8
GALVANIZED THREADED
FASTENERS
SET IN FULL BED OF NON
CURING SEALANT - TYPICAL
NOTE(S):
1. VERIFY ALL DIMENSIONS IN THE
FIELD.
2. SUBMIT STANDARD
MANUFACTURER'S COLOR
CHART TO ARCHITECT PRIOR TO
FABRICATION/INSTALLATION.
1"
WALL SUBSTRATE BOARD: (2) LAYERS
OF 1/2" PLYWOOD - SECURE
TO EXISTING W/ SPRAY ADHESIVE &
THREADED FASTENERS
2X BLOCKING - TYPICAL @ TOP &
BOTTOM OF INFILL
EXISTING CONCRETE
COPING TO REMAIN
EXISTING MASONRY
CONSTRUCTION
(TYPICAL) - VERIFY IN
FIELD
A102
PARAPET AT ROOF AREA D & E
SCALE: 3"=1'-0"
A101
2"
STIFFENER AT MID SPAN - REFER TO
NOTE BELOW
NOTE(S):
1. AT RIDGE LOCATIONS W/ LONG METAL
SPANS PROVIDE A METAL STIFFENER
AT MID POINT OF THE METAL
CLADDING.
PREFINISHED 24 GAUGE CONTINUOUS
METAL OVER INSIDE FACE OF PARAPET.
COLOR AS SELECTED BY
OWNER/ARCHITECT
1" HEM @ BOTTOM OF METAL COVERING
W/ CONTINUOUS 22 GAUGE CLEAT
METAL COUNTERFLASHING OVER STEP
FLASHING - REFER TO DETAIL 9/A102
FOR SIMILIAR
METAL COPING - REFER TO
DETAIL 10/A102
CONTINUOUS CLEAT -
REFER TO DETAIL 10/A102
5/8" PLYWOOD
1/2" OR 5/8" PLYWOOD SHIM
FOR SLOPE
SECURE METAL COPING 12"
O.C. W/ EPDM GASKETED
THREADED FASTENERS
OVERLAP METAL SIDING
W/ MEMBRANE
ASSUMED EXISTING 2X
BLOCKING
A101
EDGE METAL & CONTINUOUS
CLEAT - REFER TO DETAIL 9/A102
A102
ROOF EDGE AT ROOF AREA A
SCALE: 3"=1'-0"
EXISTING METAL SIDING -
TYPICAL
1- 1/
2" M
IN
IM
U M
EXISTING WOOD ROOF
DECK - VERIFY IN FIELD
FASCIA METAL & CONTINUOUS
CLEAT - REFER TO DETAIL 9/A102
2X BLOCKING & (1) 1/4" SHIM -
SECURE 8" O.C. (STAGGERED) WITH
GALVANIZED STEEL THREADED
FASTENERS
NOTE(S):
1. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONSTRUCTION.
2. PROVIDE METAL CLOSURES AT EDGE BLOCKING TRANSITIONS.
EQ
U
AL
EQ
U
AL
A102
RISING WALL AT EIFS
SCALE: 3"=1'-0"
A102
RISING WALL AT METAL SIDING
SCALE: 3"=1'-0"
EXISTING METAL SIDING
EXISTING AIR/VAPOR BARRIER
OVER SLIP FLASHING (TYPICAL)
METAL "SLIP" FLASHING - REFER
TO DETAIL9/A102
CONTINUOUS TERMINATION "LIP" BAR -
SECURE 8" O.C. W/ #8 GALVANIZED STEEL
THREADED MASONRY FASTENERS. NON
CURING SEALANT UNDER MEMBRANE PRIOR
TO SECUREMENT
EXISTING WOOD ROOF DECK -
TYPICALEXISTING WOOD ROOF DECK -
TYPICAL
EXISTING EIFS CLADDING
NON CURING SEALANT TOOLED
TO DRAIN - TYPICAL
COUNTER FLASHING - REFER TO
DETAIL 9/A102 FOR SIMILIAR
CONTINUOUS TERMINATION "LIP" BAR -
SECURE 8" O.C. W/ #8 GALVANIZED STEEL
THREADED MASONRY FASTENERS. NON
CURING SEALANT UNDER MEMBRANE PRIOR
TO SECUREMENT
WALL SUBSTRATE BOARD: 1/2"
PLYWOOD - CHAMFER @ TOP, SECURE
TO EXISTING W/ SPRAY ADHESIVE &
THREADED FASTENERS
A102
AT RISING MASONRY WALL
TYPICAL COUNTERFLASHING
SCALE: 3"=1'-0"
COUNTER FLASHING - REFER TO
DETAIL 9/A102
EXISTING MASONRY
CONSTRUCTION - VERIFY IN FIELD
CONTINUOUS TERMINATION "LIP" BAR -
SECURE 8" O.C. W/ #8 GALVANIZED STEEL
THREADED MASONRY FASTENERS. NON
CURING SEALANT UNDER MEMBRANE PRIOR
TO SECUREMENT
EXISTING WOOD ROOF DECK -
TYPICAL
NON CURING SEALANT - TOOL TO
DRAIN
A102
METAL COPING
SCALE: 3"=1'-0"
11 8"
3 1 4 "
21 4"
8"
13 8"
2 3 8 "
METAL NOTE(S):
1. EDGE METAL, FASCIA METAL, METAL CLOSURES, & COUNTER FLASHINGS TO BE PREFINISHED 24 GAUGE
GALVANIZED STEEL UNLESS NOTED OTHERWISE. CONTINUOUS CLEATS ARE TO BE 22 GAUGE
GALVANIZED STEEL.
2. VERIFY ALL DIMENSIONS IN THE FIELD.
3. SUBMIT STANDARD MANUFACTURER'S COLOR CHART TO ARCHITECT PRIOR TO
FABRICATION/INSTALLATION.
COUNTER "SLIP" FLASHING -
SECURE 8" O.C. W/ #8
GALVANIZED STEEL THREADED
FASTENERS (TYPICAL)
SET IN FULL BED OF NON CURING
SEALANT (TYPICAL)
NON CURING SEALANT - TOOL TO
DRAIN
COUNTER FLASHING - SECURE 8"
O.C. W/ #8 GALVANIZED STEEL
THREADED FASTENERS (TYPICAL)
5/8" HEM (TYPICAL)
AT DETAIL 7/A102AT DETAIL 6/A102
METAL COPING -
PREFINISHED 24 GAUGE
GALVANIZED STEEL. COLOR
AS SELECTED BY
OWNER/ARCHITECT
CONTINUOUS CLEAT - 22
GAUGE GALVANIZED STEEL.
SECURE 8" O.C. W/ #8
GALVANIZED STEEL
THREADED FASTENERS
2"
4"
1'-05
8" FIELD VERIFY
5/8" HEM (TYPICAL)
1/2" RETURN
PROVIDE 1/2" COVER BOARD AT
CRICKETS
PROVIDE 1/2" COVER BOARD AT
CRICKETS
PROVIDE 1/2" COVER BOARD AT
CRICKETS
AT DETAIL 4/A102
TAPERED INSULATION
CRICKET - TYPICAL
FIELD VERIFY
EQ
U
AL
FASCIA METAL
CONTINUOUS CLEAT
3"
4"
51 2"
51 2"
DRAWN BY |
REVISIONS
© | ALL RIGHTS RESERVED
CHECKED BY |
PROJECT #|
R oo f R ep la ce m en t P ha se
(A re as A
,D
E
P oc at el lo , I
D
EA
ST
D
IL
LO
N S
T.
U
.S . D
EP
AR
TM
EN
T O
F
AG
R
IC
U
LT
U R
E
AP
H
IS
CONTRACT DOCUMENTS
11.22.2024
USDA_REROOF1
06.29.17 11:09 PM | L:\USDAPSD_REROOF1\Phase 2 re-roof dwgs\Arch\USSD_A102.dwg A102
ROOFING DETAILS
KEELER
ROBERTS
BASE FLASHING - FULLY
ADHERED
DEPRESS TABS
A103
EXISTING ROOF HATCH
SCALE : 3"=1'-0"
SECURE AS REQUIRED
BY MANUFACTURER
PREMANUFACTURED
PIPE BOOT
S.S. CLAMPING BAND
NON CURING SEALANT
UNDER (TYP.)
NO-HUB CONNECTION
WITH S.S. CLAMPS
EXTEND PLUMBING VENT AS
NECESSARY FOR TOP OF
PIPE TO BE 12" INCHES
ABOVE FINISHED ROOF
EXISTING PIPE THRU
ROOF
FLASHING MEMBRANE - TYPICAL
S.S. CLAMPING BAND
PREMANUFACTURED PIPE BOOT FIELD FABRICATED
A103
PIPE BOOT/ FIELD FABRICATED PENETRATION
SCALE: 3"=1'-0"
EXISTING WOOD ROOF
DECK
A101
ROOF DRAIN: SMITH MODEL 1015 ROOF
DRAIN WITH ADJUSTABLE EXTENSION AND
CAST IRON DOME AS MANUFACTURED BY
J.R. SMITH
L OF DRAINC
31 2"
IN
SU
L
METAL SUMP RECEIVER PAN -
TYPICAL
SLOPE
1/2":12"
A103
W/ ADJUSTABLE EXTENSION
JR SMITH 1015 - ROOF DRAIN
SCALE = 3"=1'-0"
4'-0" TO EDGE OF
TAPERED AREA
4'-0" TO
L OF DRAINC
EDGE OF SUMP
FILL ALL VOIDS/CAVITIES W/ SPRAY
POLYURETHANE FOAM
NON-CURING SEALANT-
ALL SIDES
CHAMFER
EXISTING WOOD ROOF
DECK - TYPICAL
TEMPORARY ROOF/AIR
BARRIER
NOTES:
1. LAYOUT TAPERED INSULATION PACKAGE SO MINIMUM INSULATION
THICKNESS (POLYISOCYANURATE) MEASURED AT THE DRAIN CENTER LINE
(℄) IS 3-1/2"
UNDER DECK CLAMP - TYPICAL
KALWALL SKYLIGHT
EXISTING STRUCTURAL
FRAMING MEMBER - TYPICAL
EXISTING WOOD
ROOF DECK -
TYPICAL
UNDERLAYMENT
A103
B VENT THRU ROOF - TYPICAL
ROOF AREAS D & E SCALE: 3"=1'-0"
STORM COLLAR - TYPICAL
B VENT- TYPICAL
SHINGLE OVER METAL
FLANGE - TYPICAL
SHINGLE UNDER METAL
FLANGE - TYPICAL
FLUE CAP
HIGH TEMP. URETHANE SEALANT
24 GA. GALV. STL. B VENT
FLASHING - ALL SEAMS SOLDERED
A103
KALWALL DETAIL
ROOF AREA D SCALE: 3"=1'-0"
METAL APRON - REFER TO
DETAIL 3/A103
ICE & WATER SHIELD - UP &
OVER RISING WALL
ASPHALT SHINGLES
EXISTING CONSTRUCTION -
FIELD VERIFY
UNDERLAYMENT
EXISTING PIPE
THRU ROOF
A103
PREMANUFACTURED PIPE BOOT - SHINGLES
SCALE: 3"=1'-0"
EPDM PIPE BOOT
SHINGLES
EXISTING WOOD
ROOF DECK
UNDERLAYMENT
ASPHALT CEMENT EACH
LAYER - TOP & SIDES
A103
METAL APRON DETAIL
ROOF AREAS D&C SCALE: 3"=1'-0"
A101
A101
A101 4" VARIES
8"
NOTE(S):
1. VERIFY ALL DIMENSIONS IN THE
FIELD.
2. SUBMIT STANDARD
MANUFACTURER'S COLOR
CHART TO ARCHITECT PRIOR TO
FABRICATION/INSTALLATION.
METAL APRON - PREFINISHED
24 GAUGE GALVANIZED STEEL.
SECURE 8" O.C. W/ #8
GALVANIZED THREADED
FASTENERS. STRIP IN W/ ICE &
WATER SHIELD
3/4" HEM
2-1/2# LEAD FLASHING (JACK) -
(TYPICAL), SOLDER ALL SEAMS
EXISTING PIPE THROUGH ROOF
BEND/FIELD FORM LEAD
1" MINIMUM INTO PIPE
1"
6" MIN.
ROOF CEMENT
UNDER
LEAVE 1/4" GAP AT TOP
FOR PIPE MOVEMENT
ASPHALT SHINGLES
A103
LEAD PIPE FLASHING - TYPICAL
ROOF AREAS D & E SCALE: 3"=1'-0"
MEMBRANE TO SHINGLE TIE-IN
ROOF AREAS D & E NO SCALE
HOT AIR WELD - 1-1/2"
WIDE MIN. (TYPICAL)
CUT EDGE SEALANT (REQUIRED IF
THERMOPLASTIC MEMBRANE IS USED)
OVERLAP MEMBRANE @ THE
TOP W/ SELF ADHERING
MEMBRANE 6" MIN
BONDING ADHESIVE - TYPICAL
WOOD ROOF DECK
SINGLE PLY MEMBRANE -
EXTEND UNDER 3 SHINGLE
COARSES
EXISTING/NEW ASPHALT
SHINGLES - TYPICAL
A103
FASTENER & PLATE -
TYPICAL
LOW SLOPE ROOF
SYSTEM - TYPICAL
EXISTING CONSTRUCTION - FIELD VERIFY
ICE AND WATER SHIELD - TURN UP WALL
EXISTING SUBSTRATE MAY VARY - FIELD VERIFY
METAL COUNTERFLASHING - REFER TO DETAIL
9/A102 FOR SIMILIAR
UNDERLAYMENT
EXISTING WOOD ROOF DECK - TYPICAL
A103
ROOF TO WALL FLASHING -TYPICAL
ROOF AREAS D & E SCALE: 3"=1'-0"
A101
A101
APRON FLASHING OVER STEP FLASHINGS AS
REQUIRED - PREFINISHED 24 GAUGE
GALVANIZED STEEL, EXTEND BEHIND WALL
FLASHING & STRIP IN W/ ICE AND WATER SHIELD
A101
EXISTING ROOF HATCH
BACKER ROD IN ENVELOPE
OF MEMBRANE
NOTES:
1. PROVIDE CRICKET ON UP-SLOPE SIDE OF CURB.
EXISTING PARAPET/RISING
WALL, & CURB - TYPICAL
WALL SUBSTRATE BOARD -
VARIES
EXISTING WOOD ROOF DECK -
TYPICAL
INSULATION - TYPICAL
FULL BED OF NON CURING
SEALANT UNDER MEMBRANE -
TYPICAL
TEMPORARY ROOF/AIR
BARRIER
SECURE 6" O.C. W/ CONT.
TERMINATION BAR & #8
THREADED FASTENERS
A103
RISING WALL/EQUIPMENT CURB
VAPOR RETARDER TIE-IN AT
NO SCALE
TEMPORARY ROOF/AIR BARRIER
SEALED UNDER BLOCKING OR
REFER TO DETAIL 10/A103
2x BLOCKING AS REQUIRED FOR
MINIMUM 8" HEIGHT
EXISTING WOOD ROOF DECK -
TYPICAL
8" M
IN
IM
U M
SEAL TEMPORARY ROOF/AIR BARRIER
AIR/VAPOR TIGHT TO DRAIN BOWL
DRAWN BY |
REVISIONS
© | ALL RIGHTS RESERVED
CHECKED BY |
PROJECT #|
R oo f R ep la ce m en t P ha se
(A re as A
,D
E
P oc at el lo , I
D
EA
ST
D
IL
LO
N S
T.
U
.S . D
EP
AR
TM
EN
T O
F
AG
R
IC
U
LT
U R
E
AP
H
IS
CONTRACT DOCUMENTS
11.22.2024
USDA_REROOF1
06.29.17 11:09 PM | L:\USDAPSD_REROOF1\Phase 2 re-roof dwgs\Arch\USSD_A102.dwg A103
ROOFING DETAILS
KEELER
ROBERTS
patt Text Box 11/A103 patt Cloud patt Line patt Line patt Text Box X patt Text Box X patt Text Box X patt Callout
SINGLE PLY MEMBRANE TO EXTEND UNDER 3 SHINGLE COURSES
patt Text Box
LETS ELIMINATE THIS DETAIL TO
SIMPLIFY WHAT WE ARE LOOKING
FOR. AND JUST COMMENT LIKE I HAVE SHOWN.
61 4"
GUTTER DIMENSIONS DOWNSPOUT DIMENSIONS
HEX HEAD STAINLESS
STL THREADED FASTENER
2 PER BRACKET
STAINLESS STEEL
THREADED FASTENER -
COLOR TO MATCH
METAL
A104
6" GUTTER & DOWNSPOUT
SCALE: 3"=1'-0"
GUTTER NOTE(S):
1. GUTTER JOINTS - JOIN ADJACENT PIECES OF GUTTER USING "BUTT JOINTS"
WITH CONCEALED PRE FINISHED 24 GA. GALV. STL SPLICE PLATE. SET SPLICE
PLATE IN BED OF NON CURING SEALANT AND SECURE WITH RIVETS. COLOR
OF RIVETS TO MATCH METAL. CLEAN SEALANT OVER RUN FROM EXPOSED
SURFACE OF GUTTER.
2. GUTTER INSIDE/OUTSIDE CORNERS - PRE FABRICATE CORNERS W/ 2" LEGS,
NEATLY MITER, SEAL LAP AND RIVET CORNER JOINTS, COLOR OF RIVETS TO
MATCH METAL. CLEAN SEALANT OVER RUN FROM EXPOSED SURFACE OF
GUTTER.
3. GUTTER EXPANSION JOINTS - CONSTRUCT USING "BUTT TYPE" JOINT AT
LOCATIONS INDICATED. REFER TO SMACNA ARCHITECTURAL SHEET METAL
MANUAL FOR APPROVED DESIGN.
4. DOWNSPOUTS - FORM USING CONTINUOUS LOCK SEAM, JOIN USING OVER LAP
JOINTS IN THE DIRECTION OF WATER FLOW, SECURE JOINT USING STAINLESS
STL THREADED FASTENERS W/ HEAD COLOR MATCHING METAL. NEATLY
MITER ALL ELLS TO RETURN DOWNSPOUT UNDER SOFFIT FROM ROOF EAVES
TO EXTERIOR WALL(S), SLOPE DOWNSPOUT AT 1/2" UNDER SOFFIT.
5. DOWNSPOUT BRACKETS - HEM ALL CUT EDGES WHERE EXPOSED ALONG
DOWNSPOUTS. PROVIDE BRACKETS AT 4' O.C. (3 MIN. PER DOWNSPOUT).
6"
5"
5"
8"
1 4"
PRE FINISHED 24 GA. GALV. STL
DOWNSPOUT (3"X3")
DROP TUBE
FULL BED OF NON CURING
SEALANT IN JOINT (TYPICAL ALL AROUND)
RIVETS AT 1" O.C. ALL SIDES -
COLOR TO MATCH METAL
STAINLESS STEEL THREADED
FASTENER
GUTTER STRAP - PRE FINISHED 24
GAUGE GALVANIZED STEEL
1" WIDE AT 24" O.C.HEX HEAD STAINLESS STEEL
THREADED FASTENER HEAD -
COLOR TO MATCH METAL
GUTTER - PRE FINISHED 24 GAUGE
GALVANIZED STEEL
4"
GUTTER DIMENSIONS
3"
3"
8"
DOWNSPOUT DIMENSIONS
1 8"
HEX HEAD STAINLESS
STL THREADED FASTENER
2 PER BRACKET
STAINLESS STEEL
THREADED FASTENER -
COLOR TO MATCH
METAL
A104
4" GUTTER & DOWNSPOUT
SCALE: 3"=1'-0"
4"
3"
3"
3"
PRE FINISHED 24 GA. GALV. STL
DOWNSPOUT (5"X5")
DROP TUBE
FULL BED OF NON CURING
SEALANT IN JOINT (TYPICAL ALL AROUND)
RIVETS AT 1" O.C. ALL SIDES -
COLOR TO MATCH METAL
STAINLESS STEEL THREADED
FASTENER
GUTTER STRAP - PRE FINISHED 24
GAUGE GALVANIZED STEEL
1" WIDE AT 24" O.C.
GUTTER - PRE FINISHED 24 GAUGE
GALVANIZED STEEL
HEX HEAD STAINLESS STEEL
THREADED FASTENER HEAD -
COLOR TO MATCH METAL
HEM EXPOSED
EDGE
"ICE & WATER SHIELD"
AROUND ENTIRE EQUIPMENT
AND CRICKET PERIMETER,
EXTEND 18" UP SIDES
FRONT BASE FLASHING -
EXTEND 4" OVER
SHINGLES AND SET IN
ASPHALT CEMENT, EXTEND
12" UP WALL SHEATHING,
ALL JOINTS LOCKED AND
SOLDERED
EXPOSED 22 GA CRICKET
COVER - EXTEND 6" ONTO ROOF
DECK AND UP WALL,LAP 6" OVER
STEP FLASHING,ALL JOINTS LOCKED
AND SOLDERED
INSTALL SLIPSHEET (TYVEC)
BETWEEN METAL FLASHING
AND "ICE AND WATER SHIELD"CUT ASPHALT SHINGLES
AROUND CURB AND
CRICKET
METAL STEP FLASHING
18"
1- 1/
2"
TYPICAL EQUIPMENT
CURB
SLOPEMIN. 3":12"
A104
TYPICAL CRICKET AT CURBS - TYPICAL
NO SCALE
A104
METAL ROOF VENT AT RIDGE
SCALE: 1-1/2"=1'-0"
EXISTING METAL ROOF VENT
ASPHALT SHINGLES
UNDERLAYMENT
COUNTER FLASHING
ASPHALT SHINGLES
STEP FLASHING -
TYPICAL
EXISTING WOOD ROOF DECKEXISTING RISING
WALL CONSTRUCTION
EXTEND COUNTER FLASHING
BEHIND EXTERIOR CLADDING AS INDICATED
TYPICAL STEP FLASHING
PRE FINISHED
24 GAUGE GALV. STEEL
METAL FLASHING (TYP)
A104
TYPICAL STEP FLASHING
SCALE: 1 1/2"=1'-0"
AIR/VAPOR BARRIER -
OVERLAP COUNTER
FLASHING (TYPICAL)
ICE & WATER SHIELD @ RISING WALL
(TYPICAL) - EXTEND UP WALL AS
INDICATED
8" @ RISING
WALL
EXISTING EXTERIOR CLADDING
UNDERLAYMENT
ICE & WATER SHIELD AT ALL
RIDGES (TYPICAL)
A101
A101
DRAWN BY |
REVISIONS
© | ALL RIGHTS RESERVED
CHECKED BY |
PROJECT #|
R oo f R ep la ce m en t P ha se
(A re as A
,D
E
P oc at el lo , I
D
EA
ST
D
IL
LO
N S
T.
U
.S . D
EP
AR
TM
EN
T O
F
AG
R
IC
U
LT
U R
E
AP
H
IS
CONTRACT DOCUMENTS
11.22.2024
USDA_REROOF1
06.29.17 11:09 PM | L:\USDAPSD_REROOF1\Phase 2 re-roof dwgs\Arch\USSD_A102.dwg A104
ROOFING DETAILS
KEELER
ROBERTS
4" RV
8" RV
ROOF AREA A
ROOF AREA E
ROOF AREA B
ROOF AREA C
ROOF AREA D
DRAWN BY |
REVISIONS
© | ALL RIGHTS RESERVED
CHECKED BY |
PROJECT #|
Po ca te llo
S up pl y
D ep ot R er oo f - P oc at el lo
, I D
EA
ST
D
IL
LO
N
S T.
U .S
. D
EP
AR
TM
EN
T
O F
AG
R
IC
U
LT
U
R E
AP
H
IS
CONTRACT DOCUMENTS
11.08.2024
0%
S U
BM
IT
TA
L
USDA_REROOF1
E101
ELECTRICAL ROOF PLAN
SCALE: 1/16"=1'-0"
10.31.24 09:04 AM | L:\USDAPSD_REROOF1\BIMCAD\Elec\USSD_E101 elec heat trace phase 2.dwg E101
ELECTRICAL ROOF PLAN -
PHASE 2
GRAGG
VICTORINO
ROOF PLAN ELECTRICAL NOTES
1. FURNISH AND INSTALL HEAT TRACE ALONG ENTIRE GUTTER AND DOWN ENTIRE LENGTH OF DOWNSPOUT. HEAT TRACE SHALL BE nVENT RAYCHEM ICESTOP OR EQUAL SELF-REGULATING HEAT CABLE. PROVIDE WITH ALL REQUIRED POWER CONNECTION KITS, END SEAL KITS, MOUNTING PLATES, AND ALL OTHER PARTS AND PIECES REQUIRED FOR A COMPLETE SYSTEM. PROVIDE NEW NEMA 3R JUNCTION BOX AND CONNECT TO EXISTING HEAT TRACE CIRCUIT AT EACH RESPECTIVE LOCATION. VERIFY RATINGS OF EXISTING CIRCUITS AND COORDINATE WITH HEAT TRACE MANUFACTURER INSTALLATION INSTRUCTIONS. PROVIDE ADDITIONAL 20A/1P CIRCUITS FED FROM NEAREST AVAILABLE PANEL AS NECESSARY. ROUTE CIRCUITS THROUGH RELAY WITH THERMOSTATIC
CONTROL PER NOTE #2.
2. EXISTING HEAT TRACE AND THERMOSTAT INSTALLED DURING PREVIOUS PROJECT PHASE. ROUTE NEW HEAT TRACE CIRCUIT(S) THROUGH RELAY AS REQUIRED TO PROVIDE AUTOMATIC CONTROL BY EXISTING THERMOSTAT. PROVIDE RELAYS, NEMA 3R ENCLOSURES, AND ALL CONNECTIONS NECESSARY TO PROVIDE AUTOMATIC CONTROL OF ALL HEAT TRACE SHOWN, AS DIRECTED BY HEAT TRACE MANUFACTURER. VERIFY THERMOSTAT PROGRAMMING TO TURN HEAT TRACE ON WHEN OUTSIDE AIR IS BELOW 40 DEGREES.
22284
L I
CENSED
P R
R O
F
ES
SIO
NAL ENG
IN
E E
S
OT
A T E
OF ID
A
H
T
Y L E
W H ES
T A
R
N D
| USSD_G001 |
| 24x36 |
| USSD_A101 |
| 24x36 |
| USSD_A102 |
| A102 |
| USSD_A103 |
| A103 |
| USSD_A104 |
| A104 |
| USSD_E101_STAMPED |
| 24x36 |
File details come from the government source that posted it. Updated .