Atch 2 - Polar Plunge Technical Items.pdf
PDF 5 MB Posted
- Attached to
- Plunge Pool Installation Services Federal contract opportunity
- Solicitation number
- FA445220Q0025
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA445220Q0025 - QnR.pdf | ||
| Amendment 02 - Revised.pdf | ||
| Amendment 02.pdf | ||
| Amendment 01.pdf | ||
| Atch 3 - Thermal Plunge Technical Items.pdf | ||
| Atch 1 - HydroWorx Plunge Pool Series Design and Installation Guide.pdf | ||
| Atch 4 - HPTC Electrical.pdf | ||
| Combined Synopsis Solicitation-PP Install.pdf | ||
| Atch 6 - HPTC Hydrotherapy Power Panel.pdf | ||
| Atch 8 - HPTC Waste and Vent.pdf | ||
| Atch 7 - HPTC Supply.pdf | ||
| Atch 5 - HPTC Hydrotherapy Area.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Component Manufacturer Model
Maintenance Pump Speck S90-1 Chemical Feeder- Brominator Pentair Rainbow Automatic Feeder 320
200 SF Cartridge Pool Filter Sta-Rite PLM200 Top Access Skimmer Hayward SP1084
Drain & Suction Cover CMP 25200 Return Fittings Waterway 400-9151
Chemical Testing Kit Taylor K-2005 Split Air-Cooled Chiller Aqualogic MT-1
2 HP Spa Jet Pump Speck 433-V
Control Pack Speck MC-761
Tile Border Selections HydroWorx
Handrail HydroWorx Figure 4
Secondary Pool Water Sanitation System Clear Comfort HWX100 Optional Water Chemistry
Handrail
Plunge Series Equipment Schedule
Maintenance System
Jet & Pump Systems
Controls
Tile Border Selections
The efficient, easy way to sanitize your pool or spa
Rainbow™ Model 300/320 Automatic Chlorine/Bromine Feeders By Pentair Water Pool and Spa®
The Rainbow™ Models 300 and 320 automatic chlorine/bromine feeders not only save time, but also reduce manual handling of chemicals.
They use large or small Trichlor or Bromine slow-dissolving tablets to make sanitizing your new or existing pool or spa easy and automatic.
Both install easily on the pressure side of the pump, downstream of the filter and heater.
The freestanding Model 300 and the in-line Model 320 both feature an external fine control valve that lets you adjust the feed rate to meet specific pool or spa requirements. The 300 is ideal for retrofitting existing pools for automatic sanitization. The 320 is designed for permanent installation in the return line of new or existing systems, and dispenses sanitizer directly into your pool or spa, downstream of all equipment.
Completely enclosed systems—no escaping fumes.
Simple, trouble-free designs—no special venting required.
Top-loading makes it easy to add chemicals. Also available in clear amber for easy tablet viewing.
Feeder extensions increase tablet or stick capacity so you can vacation without worrying about running out of chlorine.
Whether you choose the free-standing Model 300 or the in-line Model 320, Rainbow™ automatic chlorine/bromine feeders will take the work and worry out of keeping your pool sparkling clean and ready to use.
Save time, reduce manual handling of chemicals
Chamber Capacity–1" Tablet Bottom Feed Top Feed
Quantity ........................................................................98
Weight ...................................................................3.5 lbs ......................................3.5 lbs.
Chamber Capacity–3" Tablet
Quantity ........................................................................11
Weight ...................................................................4.8 lbs ......................................4.8 lbs.
Maximum Erosion in 24 Hours 0.67 lbs ..................................1.75 lbs.
Treats Pool/Spa Size in Gallons per 24 Hours*
@ 10 ppm .............................................................6,700 ..................................... 17,500
@ 5 ppm .............................................................13,400 ..................................... 35,000
@ 2½ ppm ........................................................26,800 ..................................... 70,000
Dimensions .....................17¾" H x 5" W x 10" D .......17¾" H x 5" W x 10" D
Service Clearance for Lid Removal .... 19" ..............................................19"
*using 1" Trichlor tabs
Model 320
©2009 Pentair Water Pool and Spa, Inc. All rights reserved.10/09 Part #R5-1015 pumps / filters / heaters / heat pumps / automation / lighting / cleaners / sanitizers / water features / maintenance products
Pentair Pool Products® Sta-Rite®
800.831.7133 800.831.7133 www.pentairpool.com www.staritepool.com
Available from:
Chamber Capacity Quantity Weight
1" Tablet ..................................................98 ...............................................3.5 lbs.
3" Tablet ..................................................11 ...............................................4.8 lbs.
Maximum Erosion in 24 Hours ....................................... 1.19 lbs.
Treats Pool/Spa Size in Gallons per 24 Hours*
@ 10 ppm ..................................................................................................11,900
@ 5 ppm .....................................................................................................23,800
@ 2½ ppm ................................................................................................47,600
21" H .............................................. 7" W .................................................12" D
Service Clearance for Lid Removal ..................................22¼"
*using 1" Trichlor tabs
Model 300
Flow indicator allows a quick visual read of water flow
Check valve protects pump and heater against damage from back-up of highly chlorinated water
Rainbow™ Model 300/320 Automatic Chlorine/Bromine Feeders
System 2™
Modular Media Filters
O W N E R ’ S M A N U A L
INSTALLATION, OPERATION & PARTS
MODELS
PLM100 PLM125 PLM150 PLM175 PLM200
PLM300
Sta-Rite Pool/Spa Group U.S. PATENT NO. 5190651 (Other patents pending)
293 Wright Street, Delavan, WI 53115 International: 262-728-5551, FAX: 262-728-7550 www.starite.com Union City, TN • Delavan, WI • Mississauga, Ont. • Murrieta, CA
© 2003, Sta-Rite Industries, Inc. Printed in U.S.A. S338 (Rev. 10/30/03)
This manual should be furnished to the end user of this filter; its use will reduce service calls and chance of injury and will lengthen filter life.
OUTLET
OUTLET
RELEASE
RELEASE
OUTLET
OUTLET
RELEASE
RELEASE
E N G L I S H
F R A N Ç A I S
E S P A Ñ O L
PLM200
READ AND FOLLOW SAFETY
INSTRUCTIONS!
This is the safety alert symbol. When you see this symbol on your filter or in this manual, look for one of the following signal words and be alert to the potential for personal injury.
warns about hazards that will cause death, serious personal injury, or major property damage if ignored.
warns about hazards that can cause death, serious personal injury, or major property damage if ignored.
warns about hazards that will or can cause minor personal injury or property damage if ignored.
NOTICE indicates special instructions not related to hazards.
Carefully read and follow all safety instructions in this manual and on equipment.
Keep safety labels in good condition; replace if missing or damaged.
Incorrectly installed or tested equipment may fail, causing severe injury or property damage. Read and follow instructions in owner's manual when installing and operating equipment. Have a trained pool professional perform all pressure tests.
1. Do not connect system to a city water system or other external source of pressurized water.
2. Use equipment only in a pool or spa installation.
3. Trapped air in system can cause explosion. BE SURE all air is out of system be-fore operating or testing equipment.
Before pressure testing, make the following safety checks:
• Check all clamps, bolts, lids, lock rings and system accessories before testing.
• Release all air in system before testing.
• Tighten Sta-Rite pump trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing.
• Water pressure for test must be less than 25 PSI (172 kPa).
• Water Temperature for test must be less than 100o F. (38o C).
• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation. Remove pump trap lid and retighten hand tight only.
NOTICE: These parameters apply to Sta-Rite equipment only. For non-Sta-Rite equipment, consult equipment manufacturer.
Table of Contents Safety Instructions
General Information
Specifications
Installation
Initial Startup
Filter Disassembly / Assembly .........................................................................6-7
Module Cleaning Procedure............................................................................7-8
Special Cleaning Instruction
System Inspection/Winterizing
Troubleshooting Guide
Repair Parts List
Warranty
WARNING
Hazardous Pressure!
Can cause tank explosion.
Do not connect filter to compressed air under any circumstances.
GENERAL INFORMATION
• Clean a new pool as well as possible before filling pool and operating filter.
Excess dirt and large particles of foreign matter in the system can cause seri-ous damage to the filter and pump.
• With a permanent media filter in place and operating correctly, clean water is returned to the pool faster than pool water is being contaminated. A typi-cal pool installation will require approximately one week to obtain and maintain the sparkle that your filter is capable of giving you.
• Maximum pressure is 50 PSI (345 kPa). DO NOT connect the filter to a city water system or to an individual water well system.
Hazardous pressure. Open air release valve to vent all air from system before operating system. NEVER operate filter with air trapped inside.
• The Sta-Rite modular media filter is designed to filter water for swimming pools and spas. On a new installation, we recommend:
1. Disassemble the filter after the initial cleanup.
Hazardous pressure. To prevent severe injury or major prop-erty damage, exactly follow "Filter Disassembly/Assembly Procedure" on Pages 6 and 7.
2. Remove and hose down the element assembly to remove contaminants.
• Maintain pool water pH between 7.2 and 7.6.
• Make sure that internal air bleed tube and filter are clean and installed prop-erly at top of module before operating filter.
• Make sure that Posi-Lok™ Ring is securely locked in place before operating filter.
• Maintain pressure gauge in good working order. Replace a damaged gauge immediately.
• Cleaning interval is based on pressure rise, not on length of time filter is oper-ated. Different water conditions will have different normal cleaning intervals.
• Check local codes for restrictions on waste water disposal requirements.
NOTICE: Some pool disinfectants may clog filter module. To maximize module life and filter cycle time, closely follow disinfectant manufacturer’s instructions when cleaning pool or filter. Failure to follow these instructions may affect warranty coverage of the module.
Owner’s Information
Serial Number ____________________________________________________
Dealer ___________________________________________________________
Dealer’s Telephone #_______________________________________________
Purchase Date ____________________________________________________
Installation Date ___________________________________________________
Pressure Gauge Reading at Startup ___________________________________
When to Clean the Filter The filter module should normally be cleaned when the pressure gauge reading increases 10 PSI over the start-up pressure (record the start-up pressure under “Owner’s Information”, below, right).
In some pools, accessories such as foun-tains or pool cleaners may be noticeably affected by the normal decrease in flow as the filter becomes dirty. If so, clean the fil-ter more frequently (that is, at a pressure increase of less than 10 PSI) in order to maintain the required flow.
H ead
Body
F o re A rm
U pp er A rm
Leg Joint
Leg Joint
L eg
Jo in t
H ead
Body
WARNING
Risk of drowning and falls. Place equipment at least 4 feet from pool so that children cannot climb over it into pool.
sss
Do not allow children to stand or play on filter or pump.
Dim B Minimum
Service Height
Dim A
18.58" Dia.
(472 mm)
15" Dia.
(381 mm) 2.25"
(57 mm)
Outlet
2" NPT
Drain Plug
Lower Tank Shell
Safety Latch
Posi-Lok™ Ring
Upper Tank Shell
Air Release Valve (Pressure Gauge Behind)
4310 0203
Inlet or Drain
2" NPT
2" NPT
Inlet or Drain
INLET
INLET
RELEASE
RELEASE
To Pool
From Pool
Outlet
Inlet
Pump
Filter
4085 1001
SPECIFICATIONS
FIGURE 1A – Dimensions in inches (mm)
Table 1 - Filter Specifications
Model No.
PLM100 PLM125 PLM150 PLM175 PLM200 PLM300
Filter Area sq. ft. (m2) 100(9.3) 125(11.6) 150(14) 175(16.3) 200(18.6) 300(27.9)
Max. Rated Flow GPM (LPM) Commercial 37(140) 47(178) 56(212) 66(249) 75(284) 113(428)
Max. Operating Pressure PSI (kPa) 50(345) 50(345) 50(345) 50(345) 50(345) 50(345)
Max. Continuous Water Temperature F(C) 104°(40°) 104°(40°) 104°(40°) 104°(40°) 104°(40°) 104°(40°)
Dimension A – Height (mm) 27-3/4(705) 27-3/4(705) 27-3/4(705) 27-3/4(705) 27-3/4(705) 37-5/8(956)
Dimension B – Minimum Serivce
Height (mm) 38-1/2(978) 38-1/2(978) 38-1/2(978) 38-1/2(978) 38-1/2(978) 57(1,448)
FIGURE 1B – Piping Connections
4 (28)
2 (14)
6 (41)
8 (55)
10 (69)
12 (88)
14 (97)
16 (110)
18 (124) P re ss ur e
D ro p in
P ou nd s pe r
S qu ar e
In ch kP a)
(38)
(76)
(151)
(227)
(303)
(378)
(454)
(529)
(606)
Flow in Gallons Per Minute (LPM)
20 (138)
(568)
FIGURE 2 – Pressure Drop Curve
PLM200
Air Release Valve (Pressure Gauge Behind)
INSTALLATION
Installation of filter should only be done by qualified, licensed personnel.
Filter mount must:
• Provide weather and freezing protection.
• Provide space and lighting for easy access for routine maintenance. (See Figure 1 for space requirements.)
• Provide ventilation and drainage for pump.
• Be on a reasonably level surface and provide adequate drainage.
Piping (See Figure 1B for correct connections):
• Piping must conform to local/state plumbing and sanitary codes.
• Use teflon tape, Plasto-Joint Stik®1, or Silastic RTV #732® on all male connec-tions of plastic pipe and fittings. DO NOT use pipe compounds on plastic pipe;
it will cause the pipe to crack. Do not use sealant on unions – assemble them dry and hand tight.
• Support pipe independently to prevent strains on filter.
• Fittings restrict flow; for best efficiency use fewest possible fittings.
NOTICE: Run outlet (return) piping to the filter port marked ‘outlet’ (see Figure 1A). Run inlet and drain piping to the other two 2” NPT ports which are not marked. These two ports (inlet and drain) are interchangeable to allow for the most convenient piping run. After you have piped the inlet and drain, apply the ‘inlet’ decal to the port to which you have run the inlet piping.
• For ease of maintenance, use Sta-Rite union couplings to connect the piping to the filter inlet and outlet ports.
• Keep piping tight and free of leaks: pump suction line leaks may cause trapped air in filter tank or loss of prime at pump; pump discharge line leaks may show up as dampness or jets of water.
• NOTICE: Overtightening can crack filter ports.
Valves:
• Install valves on both sides of the filter to isolate filter for easy servicing.
NOTICE: Install heater downstream of filter. If heater does not incorporate a check valve, install one at the heater inlet to prevent hot water from backing up into the filter. Filter modules damaged by excessive heat will void the warranty.
• A check valve installed ahead of filter inlet will prevent contaminants from draining back into pool.
Electrical:
• BE SURE filter grounding and bonding meets local and National Electrical Code standards. All wiring, grounding and bonding of associated equipment must meet local and National Electrical Code Standards.
1 Lake Chemical Co., Chicago, IL
NOTICE
Make sure that the filter and all pip-ing can be drained for winterizing.
See “Winterizing”, Page 9.
Hazardous pressure.
Can cause severe injury or major property damage from tank blow up.
Release all pressure and read instructions before working on filter.
INITIAL START-UP
Be sure pump is OFF before starting procedure.
Do not operate these filters at more than 50 PSI (345 kPa) under any circumstances!
1. Securely lock Posi-Lok™ ring in place by rotating ring CLOCKWISE until it “clicks” past the safety latch (see Figure 3). Stop turning as soon as the ring clicks past the latch. The ring may feel slightly loose, but it will tighten up when pump is on and filter is under pressure.
2. Fill trap on pump with water.
3. Open air release valve on top of filter.
4. Open isolation valves.
5. Start pump to purge air from system.
6. When steady stream of water comes from air release valve, close the valve.
NOTICE: Leaking around the Posi-Lok™ ring may indicate that the ring is not fully locked. In this case, proceed as follows:
A. Stop the pump, close the isolation valves, and open the air release valve to release any pressure within the filter.
B. Remove the drain plug and drain all water from the filter.
C. Push down on the top of the filter to fully seat the upper tank shell.
D. Rotate the Posi-Lok™ clockwise until it locks behind the safety latch (see Figure 3).
E. If the ring was already locked, remove it and the upper tank shell.
Inspect and clean the O-ring and all sealing surfaces. Relubricate the O-ring.
NOTICE: Lubricate O-ring only with the silicone grease provided or equiva-lent, as other lubricants may cause the ring to swell. DO NOT lubricate Posi-Lok™ ring or threads on lower tank shell as this may collect grit and make removal difficult.
After filter is operating, record filter pressure gauge reading in owner's manual for future use.
NOTICE: When installed on a new pool, after approximately 48 hours of op-eration disassemble filter and clean out plaster dust , construction debris, etc.
(see “Module Cleaning Procedure", Pages 7 and 8).
FILTER DISASSEMBLY/
ASSEMBLY PROCEDURE
Hazardous pressure. Before disassembling filter:
1. STOP PUMP.
2. CLOSE isolation valves.
3. OPEN air release valve and drain fitting.
4. WAIT until all pressure is released and water drained from filter tank and system before loosening Posi-Lok™ Ring.
Disassembly:
1. Stop the pump.
2. Close isolation valves to prevent flooding.
3. Open air release valve on top of filter tank to release all pressure from inside of tank.Depress Safety Latch to unscrew Posi-Lok™
RELEASE
RELEASE
Figure 4 – Depress safety latch to unscrew Posi-Lok™ Ring.
2149 1195
Latch
Tab
Figure 3 – Rotate Posi-Lok™ Ring until tab locks behind the safety latch.
NOTICE: Make sure that waste water disposal complies with local codes and ordinances.
4. Remove drain plug and drain all water from tank.
5. Remove Posi-Lok™ ring as follows:
a. Press safety latch (below the ring) toward the tank to release it (see Figure 4).
b. Hold latch in the release position and rotate ring COUNTERCLOCKWISE to remove. If ring is difficult to turn, tap gently with a rubber mallet to overcome initial resistance.
NOTICE: DO NOT use screwdriver or bladed instrument that may damage shell surfaces to pry tank shells apart.
6. Separate upper and lower tank shell halves using tabs on bottom of Posi-
Lok™ ring. Insert tab into slot located at tank joint and twist ring to pry shell halves apart. See Figures 5 and 6.
7. Remove O-ring from upper tank shell. Inspect for cuts, cracking, deforma-tion or signs of wear; replace if necessary.
NOTICE: To avoid strain or damage, allow filter module to drain before lift-ing it out of the tank.
SAFETY LATCH (See Figure 7) The purpose of the safety latch is to hold the Posi-Lok™ ring in the locked po-sition. If the latch is damaged, replace it as follows:
1. Press down on the small catch behind the safety latch and press or tap the latch out of the “Tee” slot in the tank (see Figure 7).
2. Snap the new latch into position.
NOTICE: DO NOT operate the filter if the safety latch is damaged or will not hold the Posi-Lok™ ring in the locked position.
Assembly:
1. Inspect and clean the tank, ring threads and O-ring groove. Replace dam-aged parts as necessary.
2. Install the filter by placing the port in the bottom of the filter cartridge over the tank outlet port. Push down firmly to seal.
3. Ensure that the air bleed assembly on top of the module is clean and prop-erly mounted.
NOTICE: Lubricate O-ring only with the silicone grease provided or equiv-alent, as other lubricants may cause the ring to swell. DO NOT lubricate Posi-Lok™ ring or threads on lower tank shell as this may collect grit and make removal difficult.
4. Install the O-ring in the upper tank shell O-ring groove. Be sure that the O-ring is clean and not twisted.
5. Push the upper tank shell into the lower tank shell to compress the O-ring.
6. Place the Posi-Lok™ ring squarely over the tank shell threads and rotate
COUNTERCLOCKWISE until the ring falls into the slots; then rotate CLOCKWISE until securely latched.
7. Follow instructions in the “Initial Startup” section of this manual.
MODULE CLEANING PROCEDURE
Follow all steps in the “Disassembly” section of this manual.
The filter module should be removed and cleaned when pressure rises more than 10 psi (69 kPa) above startup pressure. See also “When to Clean the Filter,” at left.
2152 1195 Figure 5 – Insert ring tab in slot in filter body.
Figure 6 – Roll ring to one side to loosen upper tank half.
Small Catch
Figure 7 – Safety Latch
When to Clean the Filter The filter module should normally be cleaned when the pressure gauge reading increases 10 PSI over the start-up pressure (record the start-up pressure under “Owner’s Information”, Page 3).
In some pools, accessories such as foun-tains or pool cleaners may be noticeably affected by the normal decrease in flow as the filter becomes dirty. If so, clean the fil-ter more frequently (that is, at a pressure increase of less than 10 PSI) in order to maintain the required flow.
Risk of chemical burns. Do not attempt to acid clean the filter or module. If the filter requires acid cleaning, have a trained pool professional do the job.
NOTICE: When sanitizing your pool using PHMB (polyhexamethylene bi-quanide based) cleaners, use only PHMB cleaners to clean the module. When using PHMB sanitizers, the filter module MUST be cleaned more thoroughly and frequently than for a pool using chlorine. Follow manufacturer’s instruc-tions carefully. Use of any other type of cleansers with PHMB pool sanitizers will void the filter’s warranty.
NOTICE: Avoid washing filter debris into the outlet port. Remove drain plug and flush foreign material from inside of tank before removing filter module.
1. With a hose equipped with a soft flow nozzle, wash as much dirt as possible off of the filter module while it is still inside the tank. Allow tank to drain completely.
2. Make sure that the inside of the tank is clean. Lift out the module and hose it down thoroughly. Spray the entire module surface. Allow module to drain.
3. Inspect the module. If necessary, repeat the washing operation. If the mod-ule is damaged, replace it.
NOTICE: If this cleaning method does not remove all deposits, see “Special Cleaning Instructions” section in this manual.
4. Inspect and clean air bleed filter at top of module.
5. Follow all steps in the “Assembly” and “Initial Startup” sections of this manual.
Special Cleaning Instructions:
Use this procedure to clean scale or oils which are not removed by hosing down module. Be sure to dispose of spent chemicals according to all applica-ble codes and waste disposal ordinances. Use a soft stream nozzle to minimize flying water and spray.
Risk of fire or explosion. Isolate filter from system before chemi-cal cleaning; rinse filter and elements completely before returning to service.
If filter cannot be isolated, remove media and clean at another location. Follow chemical manufacturer’s instructions for use. Do not mix chemicals except as directed by manufacturer. Do not allow cleaning chemicals to mix with or to come in contact with chlorine, bromines, other chemicals, or chemical feed devices.
1. Sponge or spray the module according to chemical manufacturer’s directions.
2. If soaking is required, remove the module from the filter tank and submerge it in a separate tank. Follow cleaner manufacturer’s instructions carefully.
3. After completing chemical manufacturer’s instructions, drain and rinse the module completely. Dispose of cleaners in accordance with local codes and disposal ordinances.
4. Rinse the inside of the filter tank. Drain it completely.
5. Follow instructions in the “Assembly” and “Initial Startup” sections of this manual.
Recommended Specialty Filter Cleaners
Filter Cleanse™, Great Lakes Biochemical
BIOGUARD Strip Kwik™, BIOGUARD KleenIt™, Softswim® Filter Cleaner,** BIOLABS, Inc.
Filter Kleen™, Haviland Products Co.
BAQUA CLEAN™, **
Zeneca, Inc.
** MUST be used when using any PHMB based sanitizer.
SYSTEM INSPECTION
General:
Wash the outside of the filter with a mild detergent and water. Rinse off with a hose.
NOTICE: DO NOT use solvents to clean the filter; solvents may damage plas-tic components in the system.
NOTICE: Open the air bleed valve and bleed all air from the filter each time the pump is stopped and restarted.
Weekly Inspection:
1. Remove debris from the pool skimmer basket.
2. Stop the pump; open the air release valve to release all pressure.
3. Remove the trap cover and basket; remove debris.
4. Check the pump for leaks. If found, see the pump owner's manual.
5. Replace the trap basket and the cover. Tighten the cover securely hand tight. DO NOT use a lid wrench to tighten it.
6. Start the pump. When the filter air release valve runs a solid stream of water, close the valve.
7. When the system has returned to normal operation, check the filter pres-sure. If the filter pressure is 10 PSI (69kPa) or more higher than the initial startup pressure, the filter needs cleaning. See “Module Cleaning Procedure”, Pages 7 and 8.
WINTERIZING
Explosion hazard. Purging the system with compressed air can cause components to explode, with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), high volume blower when air purging the pump, filter, or piping.
NOTICE: Protect the filter from freezing. Allowing the filter to freeze will dam-age it and will void the warranty.
1. Clean the filter according to instructions (Pages 7 and 8) before winterizing.
2. Stop the pump.
3. Open the air release valve; open all the system valves.
4. Remove the drain plugs from the trap, pump, and filter.
5. Drain the system piping.
A. Gravity drain system as far as possible.
B. Protect areas which retain water with non-toxic propylene glycol antifreeze (“RV antifreeze”).
6. Loosen the union nuts (if used) to drain all water from the filter interior.
Leave these nuts loose until the system is restarted.
7. Disassemble the filter (follow instructions under “Filter Disassembly”, Pages 6 and 7). Remove the filter module and store it in a warm, dry area.
8. If the filter is equipped with an optional internal spring check valve (in the tank outlet), manually open the check valve to allow any water trapped in the tank to drain.
9. Cover the filter with plastic or tarpaulin to prevent water entrance and freezing.
NOTICE
The filter outlet piping will not empty through the filter drain. Make sure that the outlet piping has a separate drain for winterizing.
1. Short Cycle Time:
NOTICE: CycleTime will vary with each installation and between different areas of the country. The follow-ing causes and remedies are for cycle times shorter than normal for your area.
A. Chlorine residual too low; maintain proper residual (consult pool professional for recommendation).
B. Flow rate too high; restrict flow to rated capacity of filter (see instruction plate on filter or specifica-tions on Page 4).
C. Filter is too small; install an additional filter.
D. Filter module is dirty or plugged; thoroughly clean the filter (see No. 4, “Plugged Module Cloth”, and “Module Cleaning Procedure", Pages 7 and 8).
E. Water is chemically out of balance; consult pool professional.
F. Algae in the pool. Apply heavy dose of chlorine or algicide as recommended by the pool manufacturer.
2. Low Flow/High Pressure:
A. Elements plugged; clean filter thoroughly (see Pages 7 and 8).
B. Pipe blocked downstream from filter; remove ob-struction.
C. Piping too small; use larger pipe (consult dealer for sizing).
D. Filter area too small; install an auxiliary filter (con-sult dealer for recommendation).
E. Outlet port check valve obstructed (if applicable);
remove obstruction to allow valve to open.
3. Low Flow/Low Pressure:
A. Pump too small; consult dealer for recommendations.
B. Plugged pump or plugged hair and lint trap; clean thoroughly.
4. Plugged Module Cloth:
A. Insufficient cleaning; follow cleaning instructions closely and clean thoroughly (see Pages 7 and 8).
B. Water is chemically out of balance; consult pool professional.
C. Excessive air in filter. Vent air from tank and check for pump suction pipe leaks. Clean air bleed filter in module assembly with a hose and soft flow nozzle.
D. Filter is too small. Install an additional filter.
E. Pool water contains iron. See “Special Cleaning Instructions”, Page 8.
F. Heavy or improper application of powdered chlo-rine tablets using a binder. See “Special Cleaning Instructions”, Page 8.
G. Algae in the pool. Apply heavy dose of chlorine or algicide as recommended by the pool manufacturer.
H. Use of incorrect chemicals with PHMB sanitizers.
Replace filter module.
5. Pool Water Not Clean:
A. Chlorine residual too low; maintain adequate chlorine residual (consult pool service technician for recommendation).
B. Filter module cloth torn, plugged, or punctured;
replace module.
C. Inadequate turnover rate; consult dealer to verify that equipment is properly sized for your pool.
D. Pump is too large and is overpumping. Reduce the flow rate.
E. The filter is installed backwards. Reinstall it correctly.
F. Pool water contains iron. See “Special Cleaning Instructions”, Page 8.
G. Heavy or improper application of powdered chlo-rine tablets using a binder. See “Special Cleaning Instructions”, Page 8.
H. Algae in the pool. Apply heavy dose of chlorine or algicide as recommended by the pool manufacturer.
6. Pool Accessories Stop Working:
A. Clean filter and observe performance of accessories.
B. If accessories perform better after filter has been cleaned, use a shorter cleaning cycle for the filter (that is, clean the filter after a pressure rise of less than 10 PSI).
TROUBLESHOOTING GUIDE
OUTLETOUTLET
RELEASERELEASE
Base rotated 90 to show check valve installed.
2A
3A
3B
2B
7A
7B 8
Key Part No. Description Qty. Number
1 Posi-Lok™ ring* 1 27001-0054 2A Air release valve assembly 1 25010-0200 2B Air release valve assembly (PLM300) 1 24206-0103S 3A Tank shell upper half* 1 27001-0020S 3B Tank shell upper half (PLM300)* 1 27001-0030S 4 Tank O-ring 1 27001-0061S 5 Tank shell lower half 1 27001-0009S 6 Safety latch for ring 1 27001-0051
7A 1-1/2” NPT plug*** 1 11201-0005B 7B Adapter fitting*** 1 24900-0510 8 O-ring*** 1 35505-1424 9 2” x 1-1/2” Pipe reducer** 2 U78-820P 10 Pressure gauge*** 1 15060-0000T 11 Air bleed assembly 1 24800-0121 12 Filter module (PLM100) 1 27002-0100S 12 Filter module (PLM125) 1 27002-0125S 12 Filter module (PLM150) 1 27002-0150S 12 Filter module (PLM175) 1 27002-0175S 12 Filter module (PLM200) 1 27002-0200S 12 Filter module (PLM300) 1 27002-0300S 13 Spring check valve** 1 27001-0130S
• Accessory package 1 27001-0140
• Decal, logo 1 27001-0041
• Decal, warning 1 27001-0042
• Decal, operating instr. 1 27002-0043
• Decal, nameplate (PLM100) 1 27002-0042
• Decal, nameplate (PLM125) 1 27002-0048
• Decal, nameplate (PLM150) 1 27002-0045
• Decal, nameplate (PLM175) 1 27002-0049
• Decal, nameplate (PLM200) 1 27002-0050
• Decal, nameplate (PLM300) 1 32155-4164
• Decal, inlet*** 1 32165-4010
• Owner’s manual 1 S338
• Teflon tape*** 1 U97-58
• O-ring grease*** 1 34725-0013
• Not illustrated.
* Includes all decals and labels.
** Optional equipment.
*** Shipped in accessory package.
REPAIR PARTS
▲ Retain Warranty Certificate (upper portion) in a safe and convenient location for your records.
DETACH HERE: Fill out bottom portion completely and mail within 10 days of purchase/installation to:
▼ Sta-Rite, Attn: Warranty Dept., 293 Wright St., Delavan, WI 53115
Pumps, filters, skimmers, underwater lights (except bulbs), accessories and fittings manufactured by Sta-Rite are war-ranted to be free of defects in material and workmanship for one (1) year from date of installation.
Product specific warranties:
Year from date of installation
HRPB, DEPB, System 3, System 2 and Posi-Clear Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 years Internal filter components and valves . . . . . . . . . 1 year
Max-E-Therm – Pool/Spa Heaters . . . . . . . . . . . . . 2 years Heater Enclosure only (Upper RH & LH;
lower enclosure; and control board enclosure)… 10 years
Automatic Pool Cleaners including Hose . . . . . . . 2 years
Cristal-Flo filters – Tanks . . . . . . . . . . . .10 years pro-rated* Valve and internal components. . . . . . . . . . . . . . . . 1 year
Posi-Flo II – Tanks . . . . . . . . . . . . . . . . . . . . . . . . . .10 years Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year
PRC Cartridge – Filter Tanks . . . . . . . . . .5 years pro-rated (1st 2 years full) Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year
System 2 Above Ground Systems – Tanks . . . . . . .10 years Pumps / Platform and Internals . . . . . . . . . . . . . . . 1 year
Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year When equipped with A.O. Smith 2-compartment motors (Does not include pumps sold as part of a systems package) . . . . . . 2 years
Traps / In-Line Strainers . . . . . . . . . . . . . . . . . . . . . 1 year
Vertical Commercial Filter – Tanks . . . . . . . . . . . .10 years Internals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year
Horizontal Commercial Filter Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 years (Years 6-9, Prorated declining 20%/year, Yr. 10 - 10%) Internals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year
* Full warranty coverage is in effect for one year after instal-lation. The pro-rated warranty covers the tank only during the 2nd through 10th year after installation. The amount cov-ered decreases by 10% each year. (ie., 2nd year 90% covered, 3rd year 80% covered, etc.).
The foregoing warranties relate to the original consumer pur-chaser (“Purchaser”) only. Sta-Rite shall have the option to re-pair or replace the defective product, at its sole discre-tion. Purchasers must pay all labor and shipping charges nec-essary to replace the product covered by this warranty.
Requests for warranty service must be made through the in-stalling dealer. This warranty shall not apply to any product that has been subject to negligence, misapplication, improper installation or maintenance, or other circumstances which are not in Sta-Rite’s direct control.
This warranty sets forth Sta-Rite’s sole obligation and Purchaser’s exclusive remedy for defective products.
STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN
LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WAR-
RANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE
DURATION OF THE APPLICABLE EXPRESS WARRANTIES
PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of inci-dental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclu-sion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Supersedes all previous publications.
Sta-Rite Industries, Inc., 293 Wright St., Delavan, WI 53115
Warranty Registration Card
Name
Address
City State Zip
Purchase Date
Product Purchased
■ New installation ■ Replacement
Type of Pool ■ Inground ■ Vinyl ■ Fiberglass ■ Gunite
Size of Pool
Years pool has been in service ■ less than 1 ■ 1-3 ■ 3-5 ■ 5-10
Purchased from:
Company name
Address
City State Zip
Please send me more information on these other products from Sta-Rite.
■ Pumps ■ Filters ■ Automatic Pool Cleaners
■ Maintenance Equipment ■ Test Strips
■ Heaters
S4877PS (Rev. 2/4/03)
STA-RITE LIMITED WARRANTY
@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@e?@@@@@@@@?e@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@@@@@@@@@?@@@@@@@@@@@@@@@@@@e@@@@@@@@@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@@@@@@?@@@@@@@@@@@@@@@@@@@@@@@@?W@@@@@@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@@@@?@@@@@@@@@@@@@@@@@@@@@@@@@@@@Y?@@@@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@W@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@Y@@@@@@@@@@@ @@@@@@@@@@@?@@@@@@@(M?h?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@Hhe?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@?@@@@@@@@@ @@@@@@@@@?@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@@@@?@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@?@@@@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@?@@@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@@?@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@?@@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@?@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@?e?O26K?fO@K?fO26KfO2@6K?e@@@@@@@@@@@@@?@@@@ @@@@@@@@@@@@@@@@@@@@@@@@@@@@6?2@@@@@6?2@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ @@@@?@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@0?4@@@@@@0?4@@@@@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@@@@0M ?I40M?fI'@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@? ?N@@@@@@@@@@@@@@@@@@ @@@@@?@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@@?@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@?@@@@@ @@@@@@?@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@?@@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@@@?@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@?@@@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@?@@@@@@ @@@@@@@@?@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@X@@@@@@@ @@@@@@@@@?@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@V@@@@@@@@ @@@@@@@@@@@@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@@@@@@@@@@@ @@@@@@@@@@W@@@@@@@@?he?@@@@@@@@@@@@@hf@@@@@@@@X@@@@@@@@@ @@@@@@@@@@@Y@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@V@@@@@@@@@@ @@@@@@@@@@@@@@@@W@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@Y@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@X@@@@@@@@@@@@@@@@
@@@@@@@@@@@@@@@@@@@@?@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@XV@@@@@@@@@?@@@@@@@@
@@@@@@@@@@@@@@@@@@@@@@?@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@V@@@@@@@@@@@@@@?@@@@@ @@@@@@@@@@@@@@@@@@@@@@@@?@@@@@@@@@@@@@@@@@@@@@@@@@X?@@@@@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@@@@@@@@e@@@@@@@@@@@@@@@@@@@@?V@@@@@@@@@@@@@@@@@@@@@@@@ @@@@@@@@@@@@@@@@@@@@@@@@@@@@@?e@@@@@@@@@@@?e@@@@@@@@@@@@@@@@@@@@@@?@@@@@ @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@g?@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
IS1084-00
HAYWARD MODEL SP1084 AUTO-SKIM
AUTOMATIC SURFACE SKIMMER
INSTALLATION AND OPERATING INSTRUCTIONS
The Auto-Skim is a rugged, versatile automatic skimmer for residential or commercial installations. The illustrations below show the standard SP1084 (#1); the SP1082GV Skimmer-Main Drain Valve Assembly installed (#2); and the SP1084 with SP1078 Equalizer Valve and SP1082FV Float Valve Assembly (#3). Consult inside pages for specific installation details and dimensions.
BASIC UNIT
A. FLOW ADJUSTMENT—For full flow, move Flo-Control Slide Plate to full open.
To adjust flow, move Slide Plate to desired position over pump outlet.
A. FULL SKIM—Place Valve Lever in straight-up position. Open Slide Plate.
B. FULL MAIN DRAIN (SWEEP)—Place Valve Lever down. Close Slide Plate.
A. EQUALIZER—Model SP1078 Equalizer Check Valve Assembly installs over front port, and is used in conjunction with the SP1082FV Float Valve Assembly. If water level drops below skimmer opening, or if skimmer flow is obstructed, the float will automatically snap shut and the equalizer valve will open. This diverts all flow to the pump from the equalizer line and prevents airlock in the pump. When the pump is shut off, and the water level condition is corrected, the float will rise and the equalizer valve will close, allowing normal skimming operation when the pump is restarted.
C. 1/2 SKIM - 1/2 MAIN DRAIN—Place Valve Lever at 45° (half-down). Open Slide Plate 1/2.
D. TO VACUUM—Remove cover and basket. Place Valve Lever straight up.
Fill vacuum hose with water, and insert into opening in Valve Chamber. Or use optional Skim-Vac over basket vacuum plate.
B.TO VACUUM—Select one convenient skimmer and remove cover, basket and float valve assembly. Screw hose adapter into pump outlet. Fill vacuum hose with water and insert over hose adapter. Throttle down flow from other skimmer(s) until desired suction is obtained through vacuum.
B. TO VACUUM—Remove cover and basket. Screw hose adapter into pump outlet. Fill vacuum hose with water and insert over hose adapter. Or use optional Skim-Vac over basket vacuum plate.
1.
SKIMMER WITH MAIN DRAIN CONNECTION
SP1084FVE–SKIMMER WITH EQUALIZER VALVE AND FLOAT VALVE ASSEMBLY
2.
3.
NOTE: When two or more skimmers are plumbed into a common suction line, the flow is balanced through the skimmers by adjusting the Flo-Control Slide Plate at each unit.
O2@@@@@@@@@@@@6K O2@@@@@@@0?4@@@@@@6Khg
W2@@@@0Mh?I4@@@6Xhf ?W&@@0M?hf?I4@@)K?he O&@(M? ?I'@@6X?h
?@@@(Y V'@@)Xh J@@(Y? ?V'@@1h
?W&@(Y V'@@L?g ?7@(Y? ?V'@)Xg J@@H N@@1g 7@5? ?3@@L?f
?J@@H?e@@@@?@@@@?W2@@6Ke@@@6K?e?V'@1?f ?7@5f@@@@?@@@@W&@@@@@@?@@@@@@@@eN@@?f ?@@Hf@@@@?@@@@@@@@@@@@?@@@@@@@@e?@@Lf ?@@?f@@@@@@@@@@@@@@@@@?@@@@@@@@e?3@1f ?@@?f@@@@@@@@@@@@@@@@@?@@@@V4@@e?N@@f J@5?e?J@@@@@@@@@@@@@?@@@?@@@@h@@f 7@H?e?7@@@@@@@@@@@@@@@Xe@@@@@@@@f@@f 3@f?@@@@@@@@@@@@@@@@)X?@@@@@@@@f@@f ?@L?e?@@@@@@@@@(?4@@@@@1?@@@@@@@5f@@f @@1?e?@@@@@@@@@Y??W@@@@@?@@@@@@0Yf@@f N@@?e?@@@@@@@@@@@@@Y@@@@?@@@@h@@f ?@@?e?@@@@@@@@@@@@@?@@@@?@@@@g?J@@f ?@@Le?@@@@?@@@@@@@@@@@@@?@@@@@@@@e?7@5f ?3@1e?@@@@?@@@@?@@@@@@@5?@@@@@@@@eJ@@Hf ?N@@L??@@@@?3@@@?3@@@@@@H?@@@@@@@5e7@@?f @@1??@@@@?V4@@?V4@@@@@e@@@@@@0Y?J@@5?f 3@@L ?7@(Y?f V'@)X? J@@Hg ?N@@1? ?W&@5?g 3@@? W&@(Y?g V'@@6X ?W&@(Yh ?V'@@)X? O&@(Y?h V4@@)K O2@@(Yhe I'@@6KhfO2@@@0Y?he ?V4@@@@@6Kf?O2@@@@0M?hf ?I4@@@@@@@@@@@@@@0M?hg
?I4@@@@@@@0M
SP1082GV
VALVE CHAMBER
ASSEMBLY
SP1082FV
FLOAT VALVE
ASSEMBLY
SP1078
EQUALIZER VALVE
(OPEN)
HP_Owner
SP1084FVE
SP1084
AUTO-SKIM
INSTALLATION INSTRUCTIONS
EQUALIZER VALVE ASSEMBLY
SP1078
Place gasket over equalizer line port. Line up gasket over holes in body.
Place Equalizer Assembly over equalizer port, solid side up.
Insert retaining screws thru ear tabs and gasket and tighten retaining screws.
1.
2.
3.
SKIM/MAIN DRAIN VALVE ASSEMBLY
SP1082GV
SKIM/MAIN DRAIN FLOAT/
BY-PASS ASSEMBLY
SP1082FV
Remove screws, pipe plug (if installed) and original slide plate from bottom of SP1082 skimmer.
Insert “O” Ring in SP1082GV Valve Housing and place in bottom of skimmer; Port “A” over MAIN DRAIN line port (front); Port “B” over PUMP PORT (rear connection).
Insert front Retaining Screw, with washer, into Valve Housing and screw down lightly into insert in skimmer body.
Insert rear Retaining Screw, with washer, through SP1082H Flo-Control Slide Plate and into Valve Housing. Screw down firmly into insert in skimmer body. Tighten front retaining screw.
1.
2.
3.
4.
Remove screw, pipe plug (if installed) and Flo- Control Slide Plate (if installed) from bottom of basic skimmer.
Attach Flo-Control Trimmer Plate to float assembly, using screw provided.
Place Float Valve Assembly, with O-ring into skimmer. Adjust Flo-Control Trimmer Plate as required.
1.
2.
3.
The SP1084 Auto-Skim is furnished with two 2” FPT outlets. One 2” x 1-1/2” reducing bushing is furnished for use in the pump suction outlet where 1-1/2” piping is desired. A 2” pipe plug is furnished for closing off the main drain (or equalizer) line opening when these lines are not used. SP1084(1) is furnished with 2” front and 1-1/2” rear outlet and one 2” pipe plug.
LOCATION OF SKIMMERS
To obtain the most effective skimming action over the entire pool surface, locate the skimmers relative to the prevailing wind and drift, shape of pool and water circulation pattern. The use of directional inlet fittings will ensure the proper circulation pattern.
INSTRUCTIONS FOR OTHER THAN
WOOD PANEL
Drill and cut out wall panel section per dimensions.
Place gasket on skimmer face, making sure holes in gasket align with holes in skimmer face. (A very light application of adhesive cement will assist in holding gasket in place).
Align skimmer face and gasket with drilled panel holes and fasten to wall panel at top center and bottom center with the two pan head securing screws.
If vinyl liner pool, install liner before proceeding with Step 5.
Align second gasket and face plate and fasten tightly to skimmer face with twelve (12) 1” screws. If vinyl liner pool, pierce liner through face plate holes one at a time prior to inserting screws. Screws secure through 1. Face Plate; 2.
Gasket; 3. Liner; 4. Wall Panel; 5. Gasket; 6. Into Skimmer Face.
If vinyl liner pool, cut out liner along inside edges of face plate.
1.
2.
3.
4.
5.
6.
INSTRUCTIONS FOR WOOD PANEL WITH
VINYL LINER
Cut out wall panel approximately 1/8” larger than outside dimensions of skimmer face (NOT face plate).
Insert skimmer into panel cut out from the rear, and butt the mounting flange against the rear of the panel. Use “U” shims, if necessary, to make face of skimmer flush with inside of the pool. Fasten the skimmer to the rear of the wood panel by screwing the proper length round head brass wood screws through the mounting flange holes.
Place gasket on skimmer face, making sure holes in gasket align with holes in skimmer face. (A very light application of adhesive cement will assist in holding gasket in place.)
Install vinyl liner.
Align second gasket and face plate and fasten tightly to skimmer face with twelve (12) 1” screws. Pierce liner through face plate holes one at a time prior to inserting screws.
Cut out vinyl liner along inside edges of face plate.
1.
2.
3.
4.
5.
6.
INSTALLATION INSTRUCTIONS
©2000 Hayward Printed in U.S.A.Rev. 7/00 A
10a 10b
SPX1082Z1
SPX1082E
SPX1082F
SPX1082K
SPX1082CA
SPX1082Z3
SPX1082H1A
SPX1084L
SPX1084B
SPX1084Z4(A)
SPX1084Z4AM
SPX1082Z5B
SPX1082H1A
SPX1082Z6
SP1078
SP1082FV
SPX1070Z2
SPX1070FA
SPX1070Z6
O-Ring Flo-Control Slide Plate w/Screw Retaining Screw Equalizer Valve Assembly Float Valve Assembly Float Valve O-Ring Flo-Control Plate Retaining Screw
Cover Retaining Screw Cover Adjusting Collar Weir Assembly Basket Vacuum Adapter Flo-Control Slide Plate w/Screw Face Plate Gasket Screw (Short) Screw (Long)
PARTS AND ACCESSORIES
REPAIR PARTS ARE AVAILABLE THROUGH YOUR LOCAL AUTHORIZED HAYWARD DISTRIBUTOR
a b
KEY PART NUMBER DESCRIPTION NO. REQ’D.
0813sb CUSTOM MOLDED PRODUCTS | 36 HERRING ROAD, NEWNAN, GA 30265 | WWW.C-M-P.COM
VGB
CERTIFICATE OF COMPLIANCE
DATE OF MANUFACTURE:
25200-2XX (UL)
25201-XXX (UL & IAPMO)
25207-7XX (IAPMO)
25207-8XX (IAPMO)
25215-0XX (UL)
25506-32X-XXX (IAPMO)
25507-0XX-010 (IAPMO)
25507-1XX-010 (IAPMO)
25508-09XL (IAPMO)
25508-12XL (IAPMO)
25508-18XL (IAPMO)
25513-0XX (IAPMO)
25513-1XX (IAPMO)
25513-25X (IAPMO)
25513-26X (IAPMO)
25513-3XX (IAPMO)
25513-4XX (IAPMO)
25513-5XX (IAPMO)
25513-6XX (IAPMO)
25513-7XX (IAPMO)
25513-8XX (IAPMO)
25514-0XX (IAPMO)
25515-0XX (IAPMO)
25515-5XX (IAPMO)
25515-7XX (IAPMO)
25516-0XX (IAPMO)
25516-25X (IAPMO)
25516-26X (IAPMO)
25516-3XX (IAPMO)
25516-4XX (IAPMO)
25516-5XX (IAPMO)
25516-7XX (IAPMO)
25517-5XX (IAPMO)
25517-7XX (IAPMO)
25519-0XX (IAPMO)
25531-0XX (IAPMO)
25537-0XX (IAPMO)
25539-0XX (IAPMO)
25539-1XX (IAPMO)
25539-5XX (IAPMO)
25539-6XX (IAPMO)
25539-7XX (IAPMO)
25539-7XX-011 (IAPMO)
25539-8XX (IAPMO)
25548-00X (IAPMO)
25548-5XX (IAPMO)
25548-70X (IAPMO)
The following products have been tested to ANSI/APSP-16 2011 per Section 1404 of the Virginia Graeme Baker Pool and Safety Act (VGB-2008) and safety regulations set forth by the CPSC.
These products are manufactured by Custom Molded Products, Inc. in Shanghai, China and certified by Underwriters Laboratories, Inc., at 2929 E. Imperial Highway, Suite 100, Brea, CA 92821 (ph: 714-223-3600) or IAPMO R&T Lab at 5001 E. Philadelphia Street, Ontario, CA 91761 (ph: 909-472-4100). A copy of the test results may be found at www.ul.com or www.pld.iapmo.org.
nlaeder Highlight
CI
RC
UL
AT
IO
N
F
ILT
RA
TI
O
N
40 80 120 170
HEAD LOSS ( Pa × 10³ )
FLOW( GPM )
Results may vary; reference data only
VGB CERTIFIED SUCTIONS
• Plastic or Stainless Steel Covers
• Tested to ANSI/APSP-16 2011
• Compliant to ANSI/APSP - 16 2011 & CPSC
Requirements
• UL Listed
REF CMP P/N DESCRIPTION BOX /
BAG
170 GPM SUCTION
A 25201-007-000 170 GPM SUCTION, 2.5" SLIP WITH GRAPHITE COVER 50
A 25201-207-100 170 GPM SUCTION, 2" SLIP WITH GRAPHITE COVER & EPDM GASKET 50
A 25201-204-100 170 GPM SUCTION, 2" SLIP WITH BLACK COVER & EPDM GASKET 50
A 25201-209-100 170 GPM SUCTION, 2" SLIP WITH CLASSIC GRAY COVER & EPDM GASKET 50
A 25201-037-000 170 GPM GRAPHITE GRAY COVER ONLY 150
A 25201-034-000 170 GPM BLACK COVER ONLY 150
A 25201-039-000 170 GPM CLASSIC GRAY COVER ONLY 150
A 25200-000-250 2.5" SLIP WALL FITTING ONLY WITH NUT & SCREW 50
A 25200-000-450 2" SLIP WALL FITTING ONLY WITH NUT & SCREW 50
172 GPM SUCTION
B 25200-202-000 172 GPM SUCTION, 2" SOCKET WITH STAINLESS STEEL COVER 50
B 25200-202-010 172 GPM STAINLESS STEEL COVER ONLY 100
SUCTION ACCESSORIES
–– 25200-060-000 COMPENSATOR RING 1000/50
–– 26210-307-935 FLAT GASKET 1000/50
–– 26210-886-040 L-GASKET 1000/50
–– 26200-252-001 COMPRESSION SEAL 1000/50
–– 25200-040-010 SUCTION NUT 1000/50
–– 61000-050-012 REPLACEMENT SCREW FOR SUCTION COVER ––
–– 25200-000-450 2" WHITE WALL FITTING 50
–– 25200-001-450 2" GRAY WALL FITTING 50
–– 25201-999-999 METAL WRENCH ––
ORDERING GUIDE
A B
PRODUCT FEATURES
ALSO AVAILABLE
See SQR Products on page 18
TECHNICAL GUIDE
• Open Area is 12.36in2
• 3-5/16" Hole Size
• Single or Multiple Suction Use
• 170 GPM (Plastic)
• 172 GPM (Stainless Steel)
DWeirich Highlight
DWeirich
Return Wall Fittings Part No. Description Color Case Weight Case Quantity List (US$)
215-91708 Return Wall Fitting 1 lh'' FPTThru White Sibs. 50 (indiv.) 4.47
215-9170 Return Wall Fitting 1 W' FPTThru White 281bs. 200 (bulk) 3.93
215-9171 Return Wall Fitting 1 W' FPTThru Black 2Sibs. 200 (bulk) 4.35
215-9177 Return Wall Fitting 1 W' FPT Thru Gray 281bs. 200 (bulk) 4.35
215-9179-DKG Return Wall Fitting 1 lh'' FPTThru Dark Gray 2Sibs. 200 (bulk) 4.35
215-9179-8EI Return Wall Fitting 1 ¥2" FPTThru Beige 281bs. ZOO(bulk) 4.35
215-9880 Return Wall Fitting 1 W' FPT x 1" S White 40 lbs. 200 (bulk) 4.61
215-9881 Return Wall Fitting 1 ¥2" FPTx1" S Black 40 lbs. 200(bulk) 5.01
215-9887 Return Wall Fitting 1 W' FPT x 1" S Gray 40ibs. 200 (bulk) 5.01
215-9889-DKG Return Wall Fitting 1 W' FPT x 1" S Dark Gray 40 lbs. 200 (bulk) 5.01
215-91508 Return Wall Fitting 1 W' FPT x 1 W' S White Sibs. 50 (indiv.) 4.35
215-9150 Return Wall Fitting 1 W' FPT x 1 W' S…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .