This Statement of Work (SOW) details a construction project for the USDA Animal and Plant Health Inspection Service (APHIS) at the Mexican Fruit Fly Rearing Facility located at Moore Air Base in Edinburg, Texas. The project involves removing existing metal corrugated sheeting from building 6418's exterior walls and installing Hebel wall panels or equivalent insulation to improve temperature control for larval rooms. The facility produces 160 million sterile flies weekly to support Mexican Fruit Fly eradication efforts in the Lower Rio Grande Valley.
The solicitation is set aside exclusively for service-disabled veteran-owned small businesses under NAICS code 238170 with a small business size standard of $19 million. The estimated project value ranges from $500,000 to $1 million. Work must be performed by EPA-certified technicians during normal business hours (Monday-Friday, 7:00 AM to 3:30 PM), with special approval required for work outside these times. Contractors must comply with facility security requirements, including having valid identification, proper vehicle documentation, and remaining within designated construction areas. The project aims to enhance the facility's environmental control and maintain its critical fruit fly eradication program.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFIs and Responses 2.docx | DOCX document | |
| RFIs and Responses.docx | DOCX document | |
| Project site visit attendance.pdf | ||
| Atch 2_Federal Construction Wage Rates_Hidalgo County.pdf | ||
| 12639525Q0169.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work For 6418 Larval Rooms Exterior Insulation Installation April 2025
1.0 Contract Project: 6418 Larval Rooms Exterior Insulation Installation
| 2.0 Location: | USDA APHIS PPQ FO MFFRF | |
| (Mexican Fruit Fly Rearing Facility) | ||
| Bldg. 6418 | ||
| 22675 N. Moorefield Rd. | ||
| Moore Air Base | ||
| Edinburg, TX 78541 |
3.0 Project Background: The goal of the Mexican Fruit Fly Rearing Facility (MFFRF), Program is the eradication of Mexican Fruit Flies, (Anastrepha ludens) from the Lower Rio Grande Valley in Texas and the northern municipalities of Tamaulipas, Mexico. Eradication will be followed by the establishment and long-term maintenance of a functional barrier to keep these areas free of Mexican fruit fly. The Mexican Fruit Fly Rearing Facility can produce 160 million sterile flies a week to service the entire Rio Grande Valley’s citrus Mexican Fruit Fly eradication program.
The building 6418 larval rooms existing roof and exterior walls are skinned with metal corrugated sheeting that retains high amounts of heat and cold ambient temperatures affecting target environmental temperatures inside. The larval rooms must maintain a specific target temperature in the inside larval room for the growth of Mexican Fruit Fly Larvae. Hebel wall panels will afford better insulation, making the rooms more environmentally friendly to maintain target temperatures.
4.0 Project Description:
4.1 Larval Rooms – Exterior Roof and Walls Measurements: The building 6418 larval room walls measure 60’ (L – NW wall) X 65’ (S wall) X 50’ (SE wall). The roof measures 60’L X 65’W – Sq.
4.2 Insulation Installation: Install Hebel (or equal) wall insulation to the exterior of building 6418 larval rooms.
4.2.1 Demolition: Remove the existing exterior metal corrugated sheeting from the walls of the 6418 larval rooms. Clean and prepare the structure for the new siding insulation.
The roof corrugated sheeting will not be removed. The roof must be washed and prepared to receive insulation that is installed on the existing roof in spray form or corrugated panel friendly.
4.2.2 New Construction: Install new Hebel (or equal) insulation on building 6418 larval room walls. Insulation connections must be tight to prevent critters, bugs, or ambient weather from entering the building.
Install spray foam or corrugated panel friendly roof insulation, maintaining a barrier that prevents critters, bugs, or ambient weather from entering the building. The roof insulation must be chemical and high traffic resistant.
Contractor must comply with applicable codes, environmental regulations in the State of Texas and local ordinances.
· All work shall be performed in accordance with all applicable State and Local codes and standards.
· All work to be performed by EPA-certified technicians and executed in a professional, workman like manner.
· All equipment and material installed on this project shall be new and unused unless otherwise noted.
· All work to be performed during normal business hours, Monday through Friday unless otherwise noted.
5.0 Project Contacts:
5.1 APHIS PPQ Facilities Manager
Gabriel Lopez
USDA, APHIS, PPQ FO – FMS
Moore Air Base 22675 North Moore Field Building 6407 Edinburg, TX 78541 Tel. No.: (956) 205-7608 Cell No.: (956) 207-9594 Email: Gabriel.Lopez@usda.gov
5.2 APHIS PPQ Supervisory Maintenance Mechanic
Javier Caltzontzint
USDA, APHIS, PPQ FO – FMS
22675 North Moore Field Building 6415 Edinburg, TX 78541 Tel. No.: (956) 205-7734 Cell No.: (956) 330-1145 Email: Javier.caltzontzint@usda.gov
6.0 Facility Security and Safety Requirements:
Moore Air Base is a restricted facility.
· Work hours are Monday through Friday from 07:00 AM to 15:30 PM. All work outside of the mentioned days and hours shall be approved by the facilities maintenance manager in writing, prior to entering the facility. This includes work during Federal holidays.
· Some of this work will be required after 3:30 and must be coordinated with the Maintenance Mechanic Supervisor.
· All Contractors must have a valid picture identification such as a driver’s license or a State identification card.
· All vehicles must have proper insurance and registration for entering the facility.
· All Contractors working at the facility will remain at the project site under the supervision of a qualified job site superintendent. Anyone found outside of the determined construction area will be removed from the facility and not allowed to return.
· All Contractors shall provide temporary and portable restroom facilities for their employees if the project has a duration of over three working days.