This document is a Government Minimum Characteristics Item Information (GMCII) for a telecommunications console system upgrade at Yokota Air Base in Japan. The solicitation (FA520925Q0076) requires the delivery and installation of a Unify OpenScape Xpert terminal (HiPath) for Buildings 315 and 1296 at the 374th Airlift Wing. The system features include dual Ethernet ports, USB connectivity, audio inputs/outputs, IP-based SIP support, 600+ line capacity, disaster recovery capabilities, and extensive customization options like 12,000 user-definable soft buttons and 200 customizable interface pages.
Critical requirements include the contractor delivering Unify HiPath system components, removing the existing system, and installing the new system at the specified locations. The contractor must possess valid Japanese business licenses and permits for industrial waste disposal, with a warning that vendors failing to provide proper documentation will be disqualified. The system operates on 230V AC power, has a maximum power consumption of 65W, and weighs approximately 2.6 kg. The delivery address is the 374th Airlift Wing Command Post at Yokota Air Base in Fussa-shi, Tokyo.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1_PolicyLetter.pdf | ||
| 2_NoticeToOfferor.pdf | ||
| Solicitation - FA520925Q0076.pdf | ||
| Brand Name JA_CP_Redacted.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1 to Solicitation# FA520925Q0076
GOVERNMENT MINIMUM CHARACTERISTICS ITEM INFORMATION
(GMCII)
Command Post Unify HiPath Upgrade, Bldg 315, 1296 374th Airlift Wing, Yokota Air Base Japan
15 August 25
WOC Telecommunications Console System – Building 315 & 1296
Equipment Name Unify OpenScape Xpert terminal (HiPath)
Products / Features
Dual 10/100BT Ethernet ports for redundancy
6 x USB 2.0 ports (480 Mbps, max 500mA)
2 x Audio Input Mono, 3 x Audio Output Mono
4 x Handset connections
VESA 75mm mounting support
Supports 600+ lines per workplace
Up to 12,000 user-definable soft buttons
200 customizable user interface pages
20 free customizable cabinet buttons
IP-based with SIP support
Standard telecommunication lines (IP & TDM)
Direct lines (ARD's & MRD's)
Intercom & Broadcast (Hoots & Hollers)
Radio and IPTV support
Central configuration storage for global free seating
Disaster recovery capabilities
High availability and redundancy options
Prioritized call queue with 1-button access
Automatic redial for missed calls
Inbound call logging
Speaker Module
Push-to-Talk/Mute handsets
Handsets with volume control
Universal handset cradle with auto-connect/disconnect
Gooseneck microphone with handsfree/Push-to-Talk modes
Attachment 1 to Solicitation# FA520925Q0076
Electrical
Primary Side
Rated Voltage 230 V AC
Voltage Range
90 - 264 V
AC,
47 - 63 Hz, 1.5 A
Power Consumption
Max 65 W
Bridging of power failures 10 ms
Secondary Side
Output Voltage
12 VDC
Max Output current 5 A
Fuse protection
5 A surge-proof
Dimensions 338 x 60 x 193 mm (13.5" x 7.5" x 2.3")
Approx. 2.6 kg
NOTES:
The Contractor will be required to deliver Unify HiPath system components (network and hardware) to Yokota and perform the required removal of existing Unify HiPath system and install new Unify HiPath at Building 315 and 1296 on Yokota Air Base.
Bldg 315 & 1296, Yokota Air Base
Fussa-shi Tokyo 197-0001
Industrial Waste Disposal Outside of the Installation: The Contractor shall possess business license or business permits to ensure compliance of disposal of Industrial Waste outside of the installation while ensuring compliance with Japanese Environmental Government Standards and Japanese Laws. Joint Venture may be considered; however, vendor shall submit proof of Joint Venture agreement and authorized Japanese Business License or Japanese Permits.
Business License or Business Permits: The contractor shall possess any and all applicable business permits, certifications, and licenses to complete industrial waste disposal in accordance with the subject Minimum Characteristics. The contractor shall ensure all documents are current with submission of the quotes.
*Vendors who fails to present the business licenses or permit for the disposal industrial waste will not be considered for award.
Delivery Address: 374th Airlift Wing/CP (Command Post)
| Unify OpenScape Xpert terminal (HiPath) |
| Equipment Name |
| Dual 10/100BT Ethernet ports for redundancy |
| 6 x USB 2.0 ports (480 Mbps, max 500mA) |
| 2 x Audio Input Mono, 3 x Audio Output Mono |
| 4 x Handset connections |
| VESA 75mm mounting support |
| Supports 600+ lines per workplace |
| Up to 12,000 user-definable soft buttons |
| 200 customizable user interface pages |
| 20 free customizable cabinet buttons |
| IP-based with SIP support |
| Standard telecommunication lines (IP & TDM) |
| Direct lines (ARD's & MRD's) |
| Intercom & Broadcast (Hoots & Hollers) |
| Radio and IPTV support |
| Products / Features |
| Central configuration storage for global free seating |
| Disaster recovery capabilities |
| High availability and redundancy options |
| Prioritized call queue with 1-button access |
| Automatic redial for missed calls |
| Inbound call logging |
| Speaker Module |
| Push-to-Talk/Mute handsets |
| Handsets with volume control |
| Universal handset cradle with auto-connect/disconnect |
| Gooseneck microphone with handsfree/Push-to-Talk modes |
| Rated Voltage |
| 230 V AC |
| 90 - 264 V AC, |
| Voltage Range |
| 47 - 63 Hz, 1.5 A |
| Primary Side |
| Power Consumption Max |
| 65 W |
| Electrical |
| Bridging of power failures |
| 10 ms |
| 12 VDC |
| Output Voltage |
| Max Output current |
| Secondary Side |
| 5 A |
| 5 A surge-proof |
| Fuse protection |
| 338 x 60 x 193 mm (13.5" x 7.5" x 2.3") |
| Dimensions |
| Approx. 2.6 kg |
| The Contractor will be required to deliver Unify HiPath system components (network and hardware) to Yokota and perform the required removal of existing Unify HiPath system and install new Unify HiPath at Building 315 and 1296 on Yokota Air Base. |
| NOTES: |
| Delivery Address: 374th Airlift Wing/CP (Command Post) |
| Bldg 315 & 1296, Yokota Air Base |
| Fussa-shi Tokyo 197-0001 |
File details come from the government source that posted it. Updated .