ATANE RFP 0041_Oct_7_24_solicitation_doc.pdf

PDF 18 KB Posted

Attached to
RFP for Automated Crack Mapping of Pearl Harbor Memorial Bridges (00174A&B)
Solicitation number
ATANE RFP 0041
Issued by
Hartford County, Connecticut

About this file

This document is a Request for Proposals (RFP) issued by ATANE Engineers, P.C. on behalf of the Connecticut Department of Transportation for the purpose of furnishing professional services in connection with State Project 170-3413. The RFP solicits proposals from qualified vendors that specialize in providing comprehensive scanning of concrete structures, specifically the Pearl Harbor Memorial Bridges (00174A&B), with automatic deficiency mapping sensors. The data collected by the sensors is to be processed by automated or semi-automated software, generating imagery, CADD and spreadsheet outputs, and quantifying crack length and width changes from previous inspection data. The RFP includes seven line items, including deficiency mapping of the bridge overlay, extradosed box girder interior and exterior, anchor and tower piers, and optional 3D modeling of the extradosed box girder and anchor/tower piers. The RFP has a start date of May 21, 2021, and an end date of June 21, 2021, with a vendor Q&A period from May 21 to June 1, 2021.

The RFP does not provide explicit information on pricing terms, set asides, incumbents, or funding requirements. It does state that the estimated total value is not specified and that payment terms are detailed in the RFP. The RFP is open to all vendors, and the Connecticut Department of Transportation will have discretion in awarding the optional 3D modeling line items.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation Number: ATANE RFP 0041

RFP for Automated Crack Mapping of Pearl Harbor Memorial

Bridges (00174A&B)

Request for Proposal (RFP)

Transportation, Dept. of

May 21, 2021 - June 21, 2021

Page:2

General Header Information

This bid has no questions defined.

ATANE RFP 0041

No. ATANE RFP 0041 Title: RFP for Automated Crack Mapping of Pearl Harbor Memorial Bridges

(00174A&B) Start Date: May 21, 2021 at 4:00:00 PM EDT End Date: June 21, 2021 at 1:00:00 PM EDT Vendor Q&A Start Date: May 21, 2021 at 4:15:00 PM EDT Vendor Q&A End Date: June 01, 2021 at 1:00:00 PM EDT Estimated Total Value:

Who can respond to this bid? : All Vendors Description: ATANE Engineers, P.C. has entered into a contract with Connecticut

Department of Transportation for the purpose of furnishing professional services in connection with State Project 170-3413 and is issuing this Request for Proposals (RFP) to solicit proposals from qualified vendors that specialize in providing comprehensive scanning of concrete structures with automatic deficiency mapping sensors. The data taken by the sensors shall be processed by automated or semi-automated software which generates imagery, CADD and spreadsheet outputs and quantifies crack length and width changes from previous inspection data.

Delivery Terms: N/A: Not Applicable Payment Terms: See Payment Notes Payment Notes: See RFP.

Contact Information: Transportation, Dept. of

Mahmood Mohammed, P.E.

Erik Laakso, P.E.

100 Great Meadow Road, Suite 400 Wethersfield, CT 06109 mmohammed@ataneconsulting.com elaakso@ataneconsulting.com

Contact Details: If you have any questions, please contact:

Mahmood Mohammed, P.E.

Erik Laakso, P.E.

100 Great Meadow Road, Suite 400 Wethersfield, CT 06109 mmohammed@ataneconsulting.com elaakso@ataneconsulting.com

Selected Categories:

Page:3

Documents:

2021 Q Bridge Deficiency Mapping_RFP_FINAL.pdf

Page:4

Item Specifications

No. Item Alternative Supplier Part No Mfr.

Name

Mfr. No Del

Date

Unit Unit Bid Qty. Total

1 Deficiency mapping Bridge

00174A&B Overlay lump sum 1.00

Item Specification for Deficiency mapping Bridge 00174A&B Overlay

Description:

Allow Vendor to Enter Negative Value : No

Exclude Line Item from Bid Total : No

2 Deficiency mapping

Extradosed Box Girder

Interior of Bridge

00174A&B lump sum 1.00

Item Specification for Deficiency mapping Extradosed Box Girder Interior of Bridge 00174A&B

3 Deficiency mapping

Extradosed Box Girder

Exterior of Bridge

00174A&B lump sum 1.00

Item Specification for Deficiency mapping Extradosed Box Girder Exterior of Bridge 00174A&B

4 Deficiency mapping

Anchor Piers (6 total for both structures) and Tower

Piers (6 total for both structures) Interiors lump sum 1.00

Item Specification for Deficiency mapping Anchor Piers (6 total for both structures) and Tower Piers (6 total for both structures) Interiors

5 Deficiency mapping

Anchor Piers (6 total for both structures) and Tower

Piers (6 total for both structures) Exteriors lump sum 1.00

Item Specification for Deficiency mapping Anchor Piers (6 total for both structures) and Tower Piers (6 total for both structures) Exteriors

6 3D Model of Extradosed

Box Girder of Bridge

00174A&B lump sum 1.00

Page:5

No. Item Alternative Supplier Part No Mfr.

Name

Mfr. No Del

Date

Unit Unit Bid Qty. Total

Item Specification for 3D Model of Extradosed Box Girder of Bridge 00174A&B

Description: Optional Item – may be awarded at CTDOT’s discretion

Buyer allows multiple proposals to be submitted for this item.

Buyer allows alternatives to be submitted for this item

Allow Vendor to Enter Negative Value : No

Exclude Line Item from Bid Total : No

7 3D Model of Anchor Piers

(6 total for both structures) and Tower Piers (6 total for both structures) Bridge

00174A&B lump sum 1.00

Item Specification for 3D Model of Anchor Piers (6 total for both structures) and Tower Piers (6 total for both structures) Bridge 00174A&B

Description: Optional Items – may be awarded at CTDOT’s discretion

Buyer allows multiple proposals to be submitted for this item.

Buyer allows alternatives to be submitted for this item

Allow Vendor to Enter Negative Value : No