These are technical engineering design drawings for the Alaska Railroad Corporation (ARRC) detailing an Under Car HVAC Support system for Passenger Coaches, specifically for ARR 551-554 rail cars. The drawings provide a comprehensive general arrangement and installation specifications for a new HVAC subframe support structure, with detailed schematics showing the integration of contractor-supplied and ARRC-provided components. The design includes precise measurements and installation instructions for inboard and outboard sidesill supports, centersill supports, and the interface with existing undercar structural elements.

The technical drawings specify fabrication requirements for supports, including using 4"x4"x0.375" ASTM A36 angle steel, with notching and fitting instructions for precise alignment with existing rail car structures. The design emphasizes contractor verification of fit and placement prior to final installation, with multiple views (top, front, left, right) and detailed scale sections showing connection points and structural modifications. The drawings are dated 8/22/2025, drawn by CDL, and approved by ARRC engineering services, indicating a forward-looking infrastructure upgrade project for the Alaska Railroad's passenger coach fleet.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT

TITLE

DRAWN

CHECKED

APPROVED SCALE

DATE

SHEET

MOTIVE POWER AND EQUIPMENT

PASSENGER COACHES

ALASKA RAILROAD

CORPORATION

ENGINEERING SERVICES

1/3 1:20

8/22/2025CDL

ARRC

ARRC

GENERAL ARRANGEMENT

ARR 551-554 UNDER CAR HVAC SUPPORT

EXISTING UNDERCAR

BOW AND VERTICAL

SUPPORTS

ARRC PROVIDED HVAC SUBFRAME

CONTRACTOR SUPPLIED

INBOARD CENTERSILL

SUPPORT

CONTRACTOR SUPPLIED

OUTBOARD SIDESILL

SUPPORT

EXISTING CAR SIDESILL

EXISTING CAR CENTERSILL

DRAWN

CHECKED

APPROVED SCALE

DATE

SHEET

MOTIVE POWER AND EQUIPMENT

PASSENGER COACHES

ALASKA RAILROAD

CORPORATION

ENGINEERING SERVICES

2/3 1:20

8/22/2025CDL

ARRC

ARRC

ARRC PROVIDED HVAC SUBFRAME

ARR 551-554 UNDER CAR HVAC SUPPORT

FIELD NOTCH ARRC PROVIDED

HVAC SUBFRAME RAILS TO

EXISTING UNDERCAR BOW AND

VERTICAL SUPPORTS, TYP OF 3 E

DETAIL E

SCALE 1:5

1.5

F

DETAIL F

SCALE 1:5

1.5

TRIM FRONT EDGE OF

TUBING 0.5" BACK FROM

FRONT OF EXISTING BOW

2"x4"x0.25" HORIZONTAL RAILS, 2 PLCS

1"x2" & 1"x3" SUBFRAM CAGE

WITH PNEUMA SEAL PLATES

TOP VIEW

FRONT VIEWLEFT VIEW RIGHT VIEW

NOTES:

1. CONTRACTOR TO VERIFY FIT AND PLACEMENT OF ARRC

PROVIDED HVAC SUBFRAME PRIOR TO FINAL INSTALLATION.

DRAWN

CHECKED

APPROVED SCALE

DATE

SHEET

MOTIVE POWER AND EQUIPMENT

PASSENGER COACHES

ALASKA RAILROAD

CORPORATION

ENGINEERING SERVICES

3/3 1:20

8/22/2025CDL

ARRC

ARRC

CONTRACTOR SUPPLIED SUPPORTS & INSTALL

ARR 551-554 UNDER CAR HVAC SUPPORT

AA

SECTION A-A

B B

SECTION B-B (ROTATED)

SCALE 1:40

C

DETAIL C

SCALE 1:5

D

DETAIL D

SCALE 1:5

TOP VIEW

SCALE 1:40

EXISTING CENTERSILL

EXISTING SIDESILL

1/8

45°

INBOARD CENTERSILL SUPPORT

FABRICATE FROM 4"x4"x0.375"

ASTM A36 ANGLE

L PER FIELD MEASUREMENTS

NOTCH FOR TIGHT

FIT TO LOWER

CENTERSILL

FLANGE

1.75

L OUTBOARD SIDESILL SUPPORT

FABRICATE FROM 4"x4"x0.375"

ASTM A36 ANGLE

L PER FIELD MEASUREMENTS

L

1.75

1/8

45°

1/8

45°

TYP

5/16

NOTCH FOR

HORIZONTAL

HVAC RAIL, TYP

NOTE:

UPPER HVAC SUBFRAME

AND SEAL PLATES OMITTED

FOR CLARITY.

G

DETAIL G

TYPICAL SUBFRAME TO

EXISTING STRUCTURE

CONNECTION

1/8

45°

TYP

ARRC SUPPLIED HVAC

SUBFRAME RAIL

Sheets and Views
Sheet1
Sheet2
Sheet3

File details come from the government source that posted it. Updated .