Appendix A Switzerland Park Project Tables.pdf

PDF 119 KB Posted

Attached to
PKAA, Switzerland Park Project
Solicitation number
DQ1 PKAA 2027000077 1
Issued by
Colorado

About this file

This document is Appendix A of the Switzerland Park Project, containing detailed project tables for mine closure work. The project involves the closure of 34 mine features (adits, shafts, and stopes) at Switzerland Park through various closure methods including machine backfill, grated closures, bulkhead installation, and exclusion fencing. The work encompasses features with varying dimensions, depths ranging from 7 to 100+ feet, and rock lining throughout. Closure methods are categorized into several types: machine backfill closures (the majority of features), grated adit closures with bat ladder alternatives, steel grated shaft closures, corrugated steel pipe closures, rock bulkhead closures, and chain-link exclusion fencing. Key specifications include the installation of excelsior wattles for stormwater sediment control on 25 to 50 linear feet of downgradient sides for most features, and the removal of existing structures such as headframes, timbers, and fencing at specified locations. Three features (SP04, SP16, and SP23) require bat exclusion protocols prior to closure, involving three-day chicken wire coverings with specific measurements to allow bat escape while preventing re-entry.

The document provides detailed work descriptions for each feature identified by ID numbers (SP01 through SP34), including UTM coordinates in NAD83 format for site location, descriptions of mine openings by dimensions and depth, references to relevant specification sections and standard drawings, and site-specific notes regarding drainage, lining conditions, and additional work requirements. Special considerations include one feature (SP30) requiring CDOT permits as a contractor responsibility, and two features (SP33 and SP34) designated as needing bat reports prior to work commencement. The project prioritizes environmental protection through bat habitat preservation where applicable, using grated closures with bat ladder alternatives for features identified as potential bat habitat. Pricing terms, funding sources, contract timeline, and award information are not included in this appendix document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Appendix A

Switzerland Park Project Table

Table 1 – Item 4.0 - Install Mine Closures

*Bat Exclusion Protocol:

The mine opening shall be covered for a minimum of three (3) days prior to the closure work starting with one-inch chicken wire. The chicken wire should cover the portal from the top to about 5-6” from the floor or bottom of the portal/entry. This will help prevent bats from entering the mine and allow any bats inside the mine prior to the exclusion effort, to escape from the mine before the closure operations.

If reclamation work is delayed after an exclusion was conducted, use a tarp to cover the opening until work can be re-started and completed. This will help prevent re-use by bats during the stopping of closure work.

Switzerland Park – Feature Work List

Table 1 – Item 4.0 - Install Mine Closures - New Features

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP01 Adit Potential

Habitat, Bat

Grate

Present:5ft by 6ft

Depth:50 ft Lining:Rock Drainage:No

Grate with Bat Grate Alternative

Section 11.0 - Grated Adit

Closure

Section 13.0 - Bat Grate Alternative

Std. Drawings #6 & 6.2

461743, 4427443

INSTALL a grated adit closure with a minimum two (2) foot by four (4) foot bat ladder in accordance with Grated Adit

Closure Specifications.

Access door and drainpipe are NOT required.

Stormwater sediment control measures are

NOT required.

SP02 Adit Bat

Grate Present:4ft by 4ft Depth:50 ft Lining:Rock Drainage:No

Grate with Bat Grate Alternative

Section 11.0 - Grated Adit

Closure Section 13.0 -

Bat Grate Alternative

Std. Drawings #6 & 6.2

461862, 4427315

INSTALL a grated adit closure with a minimum two (2) foot by four (4) foot bat ladder in accordance with Grated Adit

Closure Specifications.

Access door and drainpipe are NOT required.

Stormwater sediment control measures are

NOT required.

SP03 Adit Potential

Habitat, Bat

Grate

Excavated:6f t by 6ft

Eroded:4ft by 3ft

Present:5ft by 6ft

Depth:50 ft Lining:Rock Drainage:No

Grate with Bat Grate Alternative

Section 11.0 - Grated Adit

Closure

Section 13.0 - Bat Grate Alternative

Std. Drawings #6 & 6.2

461846, 4427302

INSTALL a grated adit closure with a minimum two (2) foot by four (4) foot bat ladder in accordance with Grated Adit

Closure Specifications.

Access door and drainpipe are NOT required.

Stormwater sediment control measures are NOT required.

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP04 Stope Exclude and Close

Present:8ft by 10ft

Depth:50 ft Lining:Rock Drainage:No

Shaft Grate Section 8.0 - Steel Grated Shaft Closure

461817, 4427229

*EXCLUDE bats prior to closing.

INSTALL a grated shaft closure in accordance with Grated Shaft Closure Specifications.

Access door, drainpipe and bat access are NOT required.

Stormwater sediment control measures are NOT required.

SP05 Adit/ Incline

Close Present:3ft by 3ft

Depth:30 ft Lining:Rock Drainage:No

Grated Corrugated Steel Pipe

Section 10.0 - Corrugated

Steel Pipe Adit Closure

461812, 4427223

CLEAR loose debris.

INSTALL a thirty-six (36) inch diameter fifteen (15) foot length of twelve (12) gauge corrugated steel pipe (CSP) with grate in accordance with Corrugated Steel Pipe Adit Specifications.

Access door, drainpipe and bat access are NOT required.

Bulkhead or PUF around the CSP and hand backfilled with on-site material. The front three (3) feet of backfill shall consist of concreted durable rock.

Stormwater sediment control measures are

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP06 Prospec t Adit Close Present:4ft by 4ft Depth:15 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461793, 4427209

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

SP07 Shaft Close Eroded:20ft by 14ft

Present:10ft by 6ft

Depth:18 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461732, 4427171

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Machine BACKFILL in accordance with

Backfill Closure Specifications with on-site material.

Stormwater sediment control measures shall be implemented prior to work on the closure.

Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP08 Stope Close Eroded:24ft by 12ft Present:20ft by 6ft Depth:25 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461733, 4427185

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required. .

Stormwater sediment control measures shall be implemented prior to work on the closure.

Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

SP09 Shaft Close Present:5ft by 5ft Depth:7 ft

Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

442722, 4427170

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Remove all vegetation and woody debris. Rock fill NOT required.

Mine dump located 25' to east at 39.993964, -105.448751

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP10 Stope Close Present:16ft by 7ft Depth:20 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461675, 4427160

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Use mine dump above highwall and rock from stope highwall for backfill.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

SP11 Stope Close Present:200ft by 25ft

Depth:30 ft Lining:Rock Drainage:No

Exclusion Fence

Section 17.0 - Chain-LInk

Fencing (Modified)

461792, 4427278

INSTALL five-hundred (500) linear feet (LF) of exclusion fence around the perimeter of the stope with steel posts as described in

Appendix B - Exclusion Fencing Specifications

Stormwater sediment control measures are

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP12 Shaft Close Present:10ft by 6ft Depth:10 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461746, 4427341

REMOVE headframe and set aside neatly.

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

SP13 Adit Close Present:3ft by 3ft

Depth:10 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461557, 4427302

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Standing water in adit observed.

Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP14 Adit Bat

Grate Present:5ft by 6ft Depth:40 ft Lining:Rock Drainage:No

Grate with Bat Grate Alternative

Section 11.0 - Grated Adit

Closure

Section 13.0 - Bat Grate Alternative

Std. Drawings #6 & 6.2

461373, 4427346

INSTALL a grated adit closure with a minimum two (2) foot by four (4) foot bat ladder in accordance with Grated Adit

Closure Specifications.

Access door and drainpipe are NOT required.

Stormwater sediment control measures are NOT required.

SP15 Prospec t Shaft

Close Present:13ft by 16ft

Depth:12 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461615, 4427372

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure.

Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP16 Shaft Exclude and Close

Present:10ft by 12ft

Depth:22 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461494, 4427326

*EXCLUDE bats prior to closing.

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

SP17 Prospec t Shaft

Close Present:11ft by 14ft

Depth:15 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461488, 4427326

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP18 Stope Close Present:11ft by 32ft Depth:25 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461452, 4427327

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

SP19 Adit Close Present:10ft by 8ft

Depth:18 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461270, 4427235

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

SP20 Prospec t Adit

Close Present:13ft by 12ft

Depth:20 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461254, 4427220

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP21 Adit Exclude and Close

Present:10ft by 8ft

Depth:20 ft Lining:Rock Drainage:No

Bulkhead Section 14.0 - Rock Bulkhead

Closure

461244, 4427205

SP21 connects with SP20.

REMOVE mining debris and set aside neatly.

*EXCLUDE bats prior to closing.

EXCAVATE to solid ground and INSTALL a rock bulkhead closure with on-site rock. A drain pipe is NOT required.

Stormwater sediment control measures are NOT required.

SP22 Stope Potential Habitat, Bat Grate

Present:12ft by 6ft

Depth:18.5 ft Lining:Rock Drainage:No

Grate with Bat Grate Alternative

Section 11.0 - Grated Adit

Closure

Section 13.0 - Bat Grate Alternative

Std. Drawings #6 & 6.2

461241, 4427206

INSTALL a grated adit closure with a minimum two (2) foot by four (4) foot bat ladder in accordance with Grated Adit

Closure Specifications.

Access door and drainpipe are NOT required.

Stormwater sediment control measures are

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP23 Stope Exclude and Close

Present:6ft by 4ft

Depth:15 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461322, 4427253

*EXCLUDE bats prior to closing.

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

SP24 Stope Close Present:4ft by 2ft

Depth:10 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461347, 4427288

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP25 Stope Close Present:10ft by 12ft Depth:10 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461338, 4427285

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

SP26 Stope Close Present:13.5f t by 100ft

Depth:40 ft Lining:Rock Drainage:No

Exclusion Fence

Section 17.0 - Chain-LInk

Fencing (Modified)

461374, 4427304

INSTALL two-hundred fifty (250) linear feet (LF) of exclusion fence around the perimeter of the stope with steel posts as described in Appendix B - Exclusion

Fencing Specifications.

Stormwater sediment control measures are

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP27 Shaft Close Present:10ft by 22ft Depth:25 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461530, 4427305

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the downgradient side of the working area.

SP28 Adit Potential Habitat, Bat Grate

Present:6ft by 6ft

Depth:40 ft Lining:Rock Drainage:No

Grate with Bat Grate Alternative

Section 11.0 - Grated Adit

Closure

Section 13.0 - Bat Grate Alternative

Std. Drawings #6 & 6.2

462828, 4428092

INSTALL a grated adit closure with a minimum two (2) foot by four (4) foot bat ladder in accordance with Grated Adit

Closure Specifications.

Access door and drainpipe are NOT required.

Stormwater sediment control measures are

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP29 Shaft Close Present:10ft by 12ft Depth:15 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461411, 4430059

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Fifty (50) feet of excelsior wattles shall be installed on the downgradient side of the working area.

SP30 Adit Potential

Habitat, Bat

Grate

Present:7ft by 5ft

Depth:100+ ft Lining:Rock Drainage:No

Grate with Bat Grate Alternative

Section 11.0 - Grated Adit

Closure

Section 13.0 - Bat Grate Alternative

Std. Drawings #6 & 6.2

4603648, 4425147

CDOT permits are REQUIRED and are the CONTRACTOR’S responsibility to obtain and comply with.

INSTALL a grated adit closure with a minimum two (2) foot by four (4) foot bat ladder in accordance with Grated Adit

Closure Specifications.

An access door is NOT required.

Stormwater sediment control measures are

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP31 Shaft Close Present:12ft by 4ft Depth:10 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

463436, 4429090

REMOVE timbers and debris and dispose at an approved landfill facility.

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. The depression (8’L x 6’W x 3’D) adjacent to the feature shall be backfilled to provide an excavator work area. Rock fill

NOT required.

REMOVE and DISPOSE of existing barbed-wire fence.

Stormwater sediment control measures shall be implemented prior to work on the closure. Fifty (50) feet of excelsior wattles shall be installed on the downgradient side of the working area.

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP32 Shaft Close Present:13ft by 9ft Depth:10 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461712, 4427175

REMOVE timbers and set aside neatly.

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rock fill NOT required.

Stormwater sediment control measures shall be implemented prior to work on the closure. Fifty (50) feet of excelsior wattles shall be installed on the downgradient side of the working area.

SP33 Stope Close - Need Bat

Report

Present:26ft by 19ft

Depth:8 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461666, 4427119

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material. Rockfill is NOT required.

The feature is partially backfilled with sediment from hillside / road erosion.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the

Featur e ID Type

Bat Report

Description of Mine Opening

Closure Method

General Bid Specifications and Drawings

UTM

(X,Y)

NAD83 Work Description / Notes SP34 Stope Close -

Need Bat

Report

Present:34ft by 19ft

Depth:10 ft Lining:Rock Drainage:No

Machine Backfill

Section 2.0 - Backfill Closure

461688, 4427133

INSTALL ten (10) cubic yards (CY) of imported riprap. The imported riprap material shall consist of hard, durable and well-graded material with a median diameter of approximately eighteen (18) inches and sufficient finer particles to minimize the presence of voids.

The feature is partially backfilled with sediment from hillside / road erosion.

The stope connects two adits. The west adit - 4'W x 6'H x 4" plug depth, east adit

8'W x 4'H x 4' plug depth.

Machine BACKFILL in accordance with Backfill Closure Specifications with on-site material.

Stormwater sediment control measures shall be implemented prior to work on the closure. Twenty-five (25) feet of excelsior wattles shall be installed on the