S O

L

IC

IT

A T

IO

N

F

IL

E

A

M E

D W

B Y

C K

D

D E

S

IG

N

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

NUMBER

IDENTIFICATION

SHEET

OF ENGINEERS

US ARMY CORPS

D A

T E

F

U

M B

E R

S

IZ

E

S U

B M

IT

T

P L

T

C

A L

E

P L

T E

D A

T E

C O

R P

F

E

N G

IN

E E

R S

U .S .A

R M

Y

E

N G

IN

E

R

IS

T R

IC

T

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

C O

N T

R A

C

Sheet of

S E

O U L ,K

O R E

FAR EAST DISTRICT

O

U L a u t o d e s ig n a u t o u s e r n a m e a u t o s y t im e a u t o s h o r t d e s ig n a u t o s c a le

R O

D R

IG

U

Z

L F

C

Y O

N G

P Y

O N

G

K O

R E

A

F Y

M

N G

P

O J E

C T

S

J

U L

W

U M

C

A N

S I

H

O M

A S

J .D

A V

IS

IN

C

J U

N G

S

O C

IA

T E

D A

R C

H

IT

E C

G

IN

E E

NOT TO SCALE

6 7 8 9 22

11 14

DISPENSER

HOSE REEL

80mm DRYBREAK FILL POINT

MONITORING SYSTEM

INTERNAL FIRE VALVE

80mm OVERFILL PREVENTION VALVE

100mm EXTRA PORT

100mm PROBE PORT

200mm EMERGENCY VENT

50mm UPDRAFT VENT

250mm INSPECTION PORT

600mm MANWAY

50mm GAUGE STICK PORT

25mm FROST PROOF DRAIN

TANK LADDER

CONTAINMENT DRAIN

DISPENSER SHEAR VALVE

LEVEL GAUGE (WIRED TO PANEL INDICATOR)

OVERFILL PREVENTION ALARM & LIQUID

DISPENSER LEAK DETECTOR UNIT

P L A N

CONCRETE MOUNTING PAD (REFER TO CIVIL)

18925 Liters (5,000 GAL)

ELEVATION

I

A

B

C

D

E

F

G

H

J

N

K

L

M

O

P

Q

FUEL DISPENSER (FACTORY INSTALLED)

BURIED CONDUIT BY ELECTRICAL

FT

FT

NTS

NTS

DIESEL x 2 TANKS

DIESEL VEHICLE FUEL STORAGE/DISPENSING SYSTEMS SCHEMATIC DIAGRAM

KEY CARD DISPLAY & CONTROL PANEL + ATG

1R

DISPENSER LEAK DETECTION SENSOR/SYSTEM (FACTORY INSTALLED)

EMERGENCY ALARM HORN (FACTORY INSTALLED)

DISPENSER LEAK DETECTION PANEL (FACTORY INSTALLED)

DISPENSER AND PUMP CONTROL PANEL (FACTORY INSTALLED)

EMERGENCY SHUT DOWN SYSTEM (FACTORY INSTALLED)

EMERGENCY SHUT DOWN BUTTON (FACTORY INSTALLED)

MASTER LEVEL INDICATOR AND ALARM PANEL (FACTORY INSTALLED)

MONITORING AND ALARM PANEL (FACTORY INSTALLED)

FUEL ELECTRONIC LEVEL INDICATOR (FACTORY INSTALLED)

IN BURIED CONDUIT

CONDUIT FROM FUEL DISPENSING SYSTEM TO REMOTE MOUNTED MODEM

FIELD ROUTED COMMUNICATION WIRING (PHONE LINE) TO BE RUN IN

KEY CARD CONTROL PANEL (REFER TO SPECIFICATION FOR DETAILS)

AND WIRING REQUIREMENTS.

TO EXISTING TELEPHONE PEDESTAL, SEE ELECTRICAL FOR LOCATION

AREA LIGHT(2@ 400 WATTS METAL HALIDE)

SINGLE POINT POWER CONNECTION (120 V, 1 PH, 20A, 60 Hz)

1S

AND INSTALLATION DETAILS.

BUILDING, REFER TO ELECTRICAL DRAWINGS FOR INSTALLTION LOCATION

WIRING FROM PEDESTAL CONNECTION TO WORK STATION IN RANGE CONTROL

STORAGE TANK

K

BUILDING

RANGE CONTROL

R

Q

S

MONITORING AND KEY CARD SYSTEM PANEL

NTS

1L

1L

S C

H E

M A

T

IC

D

IA

G R

A M

V E

H

IC

L E F

U E

L S

T O

R A

G E D

IS

P E

N S

IN

G S

Y S

T E

M S

N Z -4 J F

U E

L D

IS

T R

IB

U T

IO

N T

R A

N S

F E

R P

O

IN

T C

W V

C W

V

C M

G

R S

F

PP602L

S E

T

ID

NAMEQTYITEMNAMEQTYITEM

SCHEMATIC KEY NOTESPARTS LIST

NOTES:

22.

1.

THE PILOT.

AND DIRECTED TOWARDS THE GROUND TO AVOID BLINDING

AREA LIGHTS SHALL BE PROVIDED WITH SHIELD

VEHICLES ONLY.

FOR GOVERNMENT OWNED AND GOVERNMENT OPERATED

THIS FUEL STORAGE/DISPENSING SYSTEM SHALL BE USED

AND WIRING TYPE.

COMMUNICATION SYSTEM. REFER TO ELECTRICAL DRAWINGS FOR ROUTING

COMMUNICATION WIRING SHALL BE INSTALLED BY ELECTRICAL TO EXISTING

SHALL BE HAVE LOADED THE INTERFACE SOFTWARE FROM THE ATG SUPPLIER.

MONITOR NOT LESS THAN 17", A PRINTER AND DVD WRITER. SYSTEM

USE MICROSOFT WINDOWS 2000 OR XP. COMPUTER SHALL INCLUDE AN LCD

OFFICER FOR LOCATION AND COMMUNICATION WIRE ROUTING. COMPUTER SHALL

COMMUNICATION SYSTEM. CONTRACTOR TO COORDINATE WITH CONTRACTING

AND FURNISHED BY THE CONTRACTOR TO BE COMPATIBLE WITH THE ATG

WORK STATION LOCATED IN THE RANGE CONTROL BUILDING TO BE PROVIDED

J

D

E

B

C

A

FG

H

I

O

L

N

P

COMMUNICATE VIA TELEPHONE LINE TO A CENTRAL COMMUNICATION SYSTEM.

AND CONTRACTOR INSTALLED) ATG SYSTEM TO HAVE THE CAPABILITY TO

ATG (AUTOMATIC TANK GAUGING SYSTEM) TO BE GFCI (GOVERMENT FURNISHED