This geotechnical report details soil investigation findings for a soccer field construction project at the U.S. Embassy in Asunción, Paraguay. The study was conducted on October 29, 2024, involving two boreholes drilled to a depth of 10 meters using Standard Penetration Tests (SPT) to evaluate soil conditions. The soil was consistently classified as sandy clay (CL) with varying stiffness, ranging from stiff to very stiff across different depths, and no groundwater was detected during the investigation.
The report provides foundation recommendations based on the soil analysis, suggesting two primary options: 1) direct foundation using footings at 1.50 meters depth with a soil bearing capacity of 1.1 Kg/cm², or 2) deep foundation using caissons at 6.00 meters depth with a soil bearing capacity of 1.5 Kg/cm². Additionally, the study includes a table of allowable soil stress at different depths and potential pile bearing capacity calculations, noting that deep foundations using reinforced concrete piles are also viable, with estimated bearing capacities ranging from 30 to 53 tons depending on pile diameter.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Annex 2- Structure.pdf | ||
| Annex 3 - Plumbing.pdf | ||
| Annex 4 - Electrical.pdf | ||
| Annex 1 - Architecture.pdf | ||
| 19PA1025Q0006 - Solicitation Soccer Sport field Project.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Architectural and Engineering (A/E) Design Services for the construction of a soccer field at the U.S. Embassy in Asuncion, Paraguay.
Geotechnical Report
Location:
Embassy of the United States of America, Asunción, Paraguay
Asuncion, Paraguay
TABLE OF CONTENTS
1. INTRODUCTION
2. SOIL EXPLORATION PROGRAM
3. SUBSOIL CONDITIONS
1. INTRODUCTION.
This study summarizes the results of the geotechnical investigation conducted to evaluate the soil conditions of a site located on Juscelino Kubitschek Avenue, near Mariscal López Avenue, within the premises of the United States Embassy in the city of Asunción. A sports field will be constructed at this location.
The geotechnical study consisted of performing two boreholes with SPT testing. The location of these boreholes can be seen in ANNEX 1.
2. SOIL EXPLORATION PROGRAM
The subsoil exploration program was carried out on October 29, 2024, to gather information about the soil. The program consisted of performing approximately 20.00 meters of drilling across two boreholes, with Standard Penetration Tests (SPT) conducted at each meter of each borehole. A split spoon sampler of the Raymond- Terzaghi type was used, complying with ASTM D-1586, with external and internal diameters of 2” and 1 3/8” respectively, driven by a 64.5-kilogram hammer falling from a height of 76 centimeters. Drilling in the soil was done manually using an auger.
Soil samples were taken at each meter of depth and were classified through tactilevisual methods in the field. Individual data sheets for each borehole were prepared based on the SPT results, which can be seen in ANNEX 2. These sheets indicate the values of the Standard Penetration Test (SPT) indices obtained from the test.
3. SUBSOIL CONDITIONS
According to tactile-visual description, the soil found in borehole S1 consists of sandy clay (CL), with a very stiff consistency at the last meter, stiff at nine meters, very stiff between eight and six meters, stiff at five meters, very stiff at four and three meters, stiff at two meters, and very stiff at the first meter of exploration. In borehole S2, the soil explored consists of sandy clay (CL), with a hard consistency at ten meters, very stiff from nine to six meters, and stiff from five meters to the first meter of exploration.
4. GROUNDWATER
During the execution of the boreholes, no presence of water was detected. This situation could vary with precipitation conditions, season, temperature, changes in topography, and other factors.
5. LEVELING
The mouth of the respective boreholes was taken as the reference level.
6. ANÁLISIS DE CARGA DE FUNDACIÓN.
Based on the soil conditions from this exploration and the type of project, a sports field, if structures are to be constructed, a feasible foundation alternative is direct foundations for the project, which could involve footings with a shaft beneath the pillars. Another foundation option is deep foundations, which could be achieved using foundation piles or caissons. Deep foundations using reinforced concrete piles are also a viable option.
7. CONCLUSIONS
Based on the SPT results, the following table of allowable soil stress is presented according to depth, in line with the SPT test results.
Depth (m) Allowable Soil Stress (Kg/ cm²) 1,00 1,1 2,00 1,1 3,00 1,2
4,00 1,2 5,00 1,3 6,00 1,5 7,00 1,6 8,00 1,6 9,00 1,6 10,00 2,00
In the case of constructing structures in the project area, considering the type of project and the SPT results, the following foundation alternative is proposed, subject to verification once the final load map is available:
● Direct foundation using footings, with the foundation seating level at 1.50 meters depth from the mouth of the respective boreholes, with a soil bearing capacity of 1.1 Kg/cm².
● Deep foundation using caissons, with the foundation seating level at 6.00 meters depth from the mouth of the respective boreholes, with a soil bearing capacity of 1.5 Kg/cm².
● Deep foundation using reinforced concrete piles. The final length, quantity, type, and section of the piles will be determined by the structural or design engineer based on the load map.
Bearing capacity of reinforced concrete piles - Compression stresses
Below is the load capacity calculation for drilled piles, based on the empirical Decourt– Quaresma formula, taking into account the SPT blow count, with a length of 10.00 meters. These values must be verified by load testing.
PILE BEARING CAPACITY (Ton) -
COMPRESSION
Diameter Length
D= 0,40m D= 0,50m D= 0,60m
10,00 m 30 ton 40 ton 53 ton
Observations: These values are for reference only and must be evaluated by the design engineer.
The results of this report are based on data obtained from discrete points within the soil profile;
variations in soil characteristics may occur.
All loads, no matter how minimal, should be transferred to foundation levels through beams.
The analysis of the final structural load state will allow the structural engineer to assess which type of foundation is most suitable in terms of cost-effectiveness and safety.
S1
S2
1.
m
1.
m
1.50 m.
1.50 m.
.0 m
20.00 m.
Roc 2,5"
10 20 30 40 50 10 20 30 40 50 60 70 80 90 ##
10,00-10,45 10
9,00-9,45 9
208,00-8,45 8
7,00-7,45 7
6,00-6,45 6
Idem
145,00-5,45 5
4,00-4,45 4
3,00-3,45 3
92,00-2,45 2
181,00-1,45 1
(S.P.T.)
0,00 m.
10 20 30 40 50 10 20 30 40 50 60 70 80 90 ##
10,00-10,45 10
9,00-9,45 9
218,00-8,45 8
7,00-7,45 7
6,00-6,45 6
135,00-5,45 5
4,00-4,45 4
3,00-3,45 3
152,00-2,45 2
121,00-1,45 1
2,5"
0,00 m.
Roc
(S.P.T.)
N N
1 12 1 18
2 15 2 9
3 14 3 17
4 12 4 18
5 13 5 14
6 23 6 17
7 28 7 19
8 21 8 20
9 23 9 14
10 33 10 28
S1S2
CLCL CL
<2 2 … 4 4 … 8 8 … 15 15 … 30
>30
SP - SC -SM
0 … 4 4 … 10 10 … 30 30 … 50
>50
N S
E W
RED PLUVIAL EXISTENTE
GA
RD
EN
ST
RIP
EX
IST
ING
CO
NS
TR
UC
TIO
N
EX
IST
ING
RA
IN D
RA
INA
GE
NE
TW
OR
K
EX
IST
ING
SE
WE
R
EXISTING RAIN DRAINAGE NETWORK
EX
IST
ING
RA
IN
DR
AIN
AG
E N
ET
WO
RK
EX
IST
ING
RA
IN
DR
AIN
AG
E N
ET
WOR
K
EXISTING RAIN DRAINAGE NETWORK
EXI
STI
NG RAIN
DRAIN
AG
E N
ETW
ORK
EXISTING RAIN DRAINAGE NETWORK
EXISTING ELECTRICAL NETWORK
JU
NC
TIO
N B
OXSOCCER FIELD
EXISTING RAIN DRAINAGE NETWORK
EXISTING RAIN DRAINAGE NETWORK
MUNICIPAL BOUNDARIES LIMIT
W or k:
Ar ea do cu m en t n am e:
Es c:
Pl an
AR
Q U
IT
EC
TU
R
E
EX
IS
TE
N
T
SE
R
VI
C
ES
SO
C
C
ER
F
IE
LD
U
S
EM
BA
SS
Y
1:
So cc er fi el d
Em ba ss y
File details come from the government source that posted it. Updated .